1.Application of nickel-titanium shape memory staples in treatment of multiple metatarsal fractures.
Jie CHEN ; Zhen YIN ; Weibo ZHOU ; Wen TAN ; Fulin ZHOU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):146-150
OBJECTIVE:
To investigate the effectiveness of nickel-titanium shape memory staples in treating multiple metatarsal fractures.
METHODS:
The clinical data of 27 patients with multiple metatarsal fractures who were treated between January 2022 and June 2023 and met the selection criteria were retrospectively analysed. The cohort consisted of 16 males and 11 females, aged 33-65 years (mean, 47.44 years). The causes of injury included heavy object impact in 11 cases, traffic accidents in 9 cases, and crush in 7 cases. Simultaneous fractures of 2, 3, 4, and 5 bones occurred in 6, 6, 4, and 8 cases, respectively, with tarsometatarsal joint injury in 3 cases. Fixation was performed using staples for 16, 22, and 9 fractures in the metatarsal neck, shaft, and the base, respectively, and 5 tarsometatarsal joint injuries. Preoperative soft tissue injuries were identified in 8 cases and classified according to the Tscherne-Oestern closed soft tissue injury classification as type Ⅰ in 5 cases and type Ⅱ in 3 cases. One case of type Ⅱexhibited preoperative skin necrosis. The patients were treated with fixation using nickel-titanium shape memory staples. Complications and fracture healing were documented. At last follow-up, the American Orthopaedic Foot and Ankle Society (AOFAS) forefoot score was used to evaluate the function, and the visual analogue scale (VAS) score was used to evaluate the pain.
RESULTS:
The 27 patients were followed up 9-19 months (mean, 12.4 months). Postoperative X-ray films revealed no loss of fracture reduction, and all fractures achieved bony union. No internal fixator loosening, breakage, or other mechanical failures was observed. The mean fracture healing time was 3.13 months (range, 3-4 months). Postoperatively, 4 cases (2 of Tscherne-Oestern type Ⅰ, 2 of type Ⅱ) developed superficial skin necrosis, which resolved with dressing changes. No infection was observed in the remaining patients, and all wounds healed. At last follow-up, the AOFAS forefoot score ranged from 70 to 95, with an average of 86.6, of which 19 cases were excellent, 6 cases were good, and 2 cases were fair, with an excellent and good rate of 92.6%; the VAS score ranged from 0 to 3, with an average of 0.9, of which 24 cases were excellent, and 3 cases were good, with an excellent and good rate of 100%.
CONCLUSION
The use of nickel-titanium shape memory staples in the treatment of multiple metatarsal fractures can effectively protect local skin and soft tissues and minimize secondary damage associated with internal fixator insertion. It is a viable surgical option for management of multiple metatarsal fractures.
Humans
;
Male
;
Female
;
Middle Aged
;
Adult
;
Titanium
;
Nickel
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Aged
;
Metatarsal Bones/surgery*
;
Fractures, Bone/surgery*
;
Treatment Outcome
;
Sutures
;
Fractures, Multiple/surgery*
2.Cyclic fatigue resistance of nickel-titanium files made by Gold heat treatment in simulated S-shaped root canals at different temperatures.
Journal of Peking University(Health Sciences) 2025;57(1):136-141
OBJECTIVE:
To compare the cyclic fatigue resistance of nickel-titanium files made by 3 new heat treatment in simulated S-shaped root canals at different temperatures.
METHODS:
Gold heat-treated nickel-titanium files TruNatomy (25 mm, tip size 26#/0.04) and ProTaper Gold (25 mm, tip size 25#/0.08) were selected as the experimental group, M wire technique nickel-titanium file ProTaper Next (25 mm, tip size 25#/0.06) was selected as the control group. It was speculated that the Gold technique used in TruNatomy nickel-titanium file was R phase separation technique, which included a complete intermediate R-phase, increasing its flexibility. ProTaper Gold was a CM wire nickel-titanium file and the increased phase transformation temperature by heat treatment introduced martensite at room temperature, while it underwent gold heat treatment on the surface, generating an intermediate R phase during phase transformation, providing hyperelastic. ProTaper Next used M wire technique, M wire included austenite at room temperature, where heat mechanical processing introduced hardened martensite, which was incapable of participating phase transformation. Because of the lower elastic modulus of hardened martensite than austenite, the flexibility of the file was increased. Twenty instruments of each nickel-titanium file were submitted to the cyclic fatigue test by using a simulated canal with double curvatures at room tem-perature (24 ℃) and 65 ℃, 10 instruments of each nickel-titanium file were selected at each temperature (n=10). At the same temperature, the number of cyclic fatigue (NCF) and fragment length were analyzed by using One-Way analysis of variance at a significance level of P < 0.05. NCF and fragment length of the same nickel-titanium file at room temperature and 65 ℃ were compared by paired sample t test and the significance level was α=0.05. Fractured surfaces were analyzed by using scanning electron microscope.
RESULTS:
In double-curved canals, all the failure of the files due to cyclic fatigue was first seen in the apical curvature before the coronal curvature. At room temperature, in the apical curvature, NCF of TruNatomy was 344.4±96.6, ProTaper Gold was 175.0±56.1, ProTaper Next was 133.3±39.7, NCF of Tru Natomy was the highest (P < 0.05). In the coronal curvature, NCF of TruNatomy was 618.3± 75.3, ProTaper Gold was 327.5±111.8, ProTaper Next was 376.6±67.9, NCF of TruNatomy was also the highest (P < 0.05). There was no significant difference among the apical and coronal fragment length of the 3 nickel-titanium files (P>0.05). At 65 ℃, in the apical curvature, NCF of TruNatomy was 289.6±65.8, ProTaper Gold was 187.5±75.4, ProTaper Next was 103.0±38.5, NCF of TruNatomy was the highest (P < 0.05). In the coronal curvature, NCF of TruNatomy was 454.2±45.4, ProTaper Gold was 268.3±31.4, ProTaper Next was 283.8±31.7, NCF of TruNatomy was also the highest (P < 0.05). The apical fragment length of ProTaper Next was the highest (P < 0.05), and there was no significant difference among coronal fragment length of the 3 nickel-titanium files (P>0.05). Compared with room temperature, at 65 ℃, in the coronal curvature, NCF of TruNatomy decreased significantly (P < 0.05). The fractured surfaces of the three nickel-titanium files demonstrated typical cyclic fatigue.
CONCLUSION
Gold heat-treated nickel-titanium file had better cyclic fatigue resistance than M wire nickel-titanium file in S-shaped root canals.
Nickel/chemistry*
;
Titanium/chemistry*
;
Hot Temperature
;
Root Canal Preparation/methods*
;
Humans
;
Materials Testing
;
Gold/chemistry*
;
Dental Alloys/chemistry*
;
Stress, Mechanical
3.Finite Element Simulation Analysis of a Nickel-Titanium Alloy Patent Foramen Ovale Occluder.
Chinese Journal of Medical Instrumentation 2025;49(2):119-124
In this paper, a preliminary stress/strain analysis of the design structure of a nickel-titanium alloy patent foramen ovale occluder is conducted with the finite element simulation analysis method. In the analysis, solid structure modeling is carried out on three different specifications of domestic patent foramen ovale occluders. Referring to the test method of fatigue performance in inspection standard YY/T 1553-2017, an initial installation deformation is applied to the model, and then the fatigue displacement of 2 mm is applied to the sample to make the model fatigue deformation. The fatigue safety factors of each type of occluder are obtained by strain simulation analysis. The results indicate that the minimum fatigue safety factors of the three specifications of domestic patent foramen ovale occluders are 2.09, 2.35 and 2.06 respectively, which all meet the design of fatigue safety factor greater than 1. Among them, 1818 and 3030 specifications of patent foramen ovale occluders have close values in minimum fatigue safety factors, and both are lower than that of 1825 model. Therefore, it is recommended to carry out physical fatigue tests on both 1818 and 3030 specifications to further verify the fatigue performance of the products.
Finite Element Analysis
;
Titanium
;
Nickel
;
Alloys
;
Foramen Ovale, Patent
;
Materials Testing
;
Septal Occluder Device
;
Stress, Mechanical
4.Research progress on metal pollutants inducing neurotoxicity through ferroptosis.
Ziyu QIN ; Yuqing CHEN ; Xinyuan ZHAO ; Shali YU
Journal of Zhejiang University. Medical sciences 2024;53(6):699-707
It has been confirmed that exposure to various metal pollutants can induce neurotoxicity, which is closely associated with the occurrence and development of neurological disorders. Ferroptosis is a form of cell death in response to metal pollutant exposure and it is closely related to oxidative stress, iron metabolism and lipid peroxidation. Recent studies have revealed that ferroptosis plays a significant role in the neurotoxicity induced by metals such as lead, cadmium, manganese, nickel, and antimony. Lead exposure triggers ferroptosis through oxidative stress, iron metabolism disorder and inflammation. Cadmium can induce ferroptosis through iron metabolism, oxidative stress and ferroptosis related signaling pathways. Manganese can promote ferroptosis through mitochondrial dysfunction, iron metabolism disorder and oxidative stress. Nickel can promote ferroptosis by influencing mitochondrial function, disrupting iron homeostasis and facilitating lipid peroxidation in the central nervous system. Antimony exposure can induce glutathione depletion by activating iron autophagy, resulting in excessive intracellular iron deposition and ultimately causing ferroptosis. This article reviews the effects of metal pollutants on ferroptosis-related indicators and discusses the specific mechanisms by which each metal triggers ferroptosis. It provides a reference for identifying targets for preventing neurotoxicity and for developing treatment strategies for neurological disorders.
Ferroptosis/drug effects*
;
Humans
;
Iron/metabolism*
;
Oxidative Stress/drug effects*
;
Neurotoxicity Syndromes/metabolism*
;
Cadmium/adverse effects*
;
Animals
;
Lipid Peroxidation/drug effects*
;
Metals/metabolism*
;
Lead/adverse effects*
;
Environmental Pollutants/toxicity*
;
Manganese/adverse effects*
;
Nickel/adverse effects*
;
Mitochondria/drug effects*
;
Signal Transduction/drug effects*
5.Application of mixture analysis methods in association between metals mixture exposure and DNA oxidative damage.
Yan Hua WANG ; Hui Ge YUAN ; Li Ya ZHANG ; Yang LIN ; Ting WANG ; Huan XU ; Xing ZHAO ; Hua Wei DUAN
Chinese Journal of Preventive Medicine 2023;57(7):1026-1031
Objectives: To study the association between metals mixture exposure and DNA oxidative damage using mixture analysis methods, and to explore the most significant exposure factors that cause DNA oxidative damage. Methods: Workers from steel enterprises were recruited in Shandong Province. Urinary metals were measured by using the inductively coupled plasma mass spectrometry method. The level of urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG) was determined by using the ultra-high performance liquid chromatography-mass spectrometry method. Bayesian kernel machine regression (BKMR), elastic net regression and quantile g-computation regression were used to analyze the association between urinary metals and urinary 8-OHdG. Results: A total of 768 subjects aged (36.15±7.40) years old were included in the study. BKMR, elastic net regression and quantile g-computation all revealed an overall positive association between the mixture concentration and increased urinary 8-OHdG. The quantile g-computation results showed that with a 25% increase in metal mixtures, the urinary 8-OHdG level increased by 77.60%. The elastic net regression showed that with a 25% increase in exposure risk score, the urinary 8-OHdG level increased by 26%. The BKMR summarized the contribution of individual exposures to the response, and selenium, zinc, and nickel were significant contributors to the urinary 8-OHdG elevation. Conclusion: Exposure to mixed metals causes elevated levels of DNA oxidative damage, and selenium, zinc, and nickel are significant exposure factors.
Humans
;
Adult
;
Nickel/toxicity*
;
Selenium
;
Bayes Theorem
;
Metals/toxicity*
;
8-Hydroxy-2'-Deoxyguanosine
;
Oxidative Stress/physiology*
;
Zinc
;
DNA Damage
6.Role of selenoprotein M knockdown in the melatonin antagonism of nickel-induced apoptosis and endoplasmic reticulum stress in mouse heart.
Xintong ZHANG ; Xiaoxue GAI ; Lihua XU ; Wenxue MA ; Qiaohan LIU ; Bendong SHI ; Cheng FANG ; Jingzeng CAI ; Ziwei ZHANG
Journal of Zhejiang University. Science. B 2023;24(5):406-417
The aim of this study was to investigate the role of selenoprotein M (SelM) in endoplasmic reticulum stress and apoptosis in nickel-exposed mouse hearts and to explore the detoxifying effects of melatonin. At 21 d after intraperitoneal injection of nickel chloride (NiCl2) and/or melatonin into male wild-type (WT) and SelM knockout (KO) C57BL/6J mice, NiCl2 was found to induce changes in the microstructure and ultrastructure of the hearts of both WT and SelM KO mice, which were caused by oxidative stress, endoplasmic reticulum stress, and apoptosis, as evidenced by decreases in malondialdehyde (MDA) content and total antioxidant capacity (T-AOC) activity. Changes in the messenger RNA (mRNA) and protein expression of genes related to endoplasmic reticulum stress (activating transcription factor 4 (ATF4), inositol-requiring protein 1 (IRE1), c-Jun N-terminal kinase (JNK), and C/EBP homologous protein (CHOP)) and apoptosis (B-cell lymphoma-2 (Bcl-2), Bcl-2-associated X protein (Bax), Caspase-3, Caspase-9, and Caspase-12) were also observed. Notably, the observed damage was worse in SelM KO mice. Furthermore, melatonin alleviated the heart injury caused by NiCl2 in WT mice but could not exert a good protective effect in the heart of SelM KO mice. Overall, the findings suggested that the antioxidant capacity of SelM, as well as its modulation of endoplasmic reticulum stress and apoptosis, plays important roles in nickel-induced heart injury.
Animals
;
Male
;
Mice
;
Antioxidants/pharmacology*
;
Apoptosis
;
Endoplasmic Reticulum Stress
;
Melatonin/pharmacology*
;
Mice, Inbred C57BL
;
Nickel/adverse effects*
;
Selenoproteins/genetics*
;
Heart/drug effects*
7.Evolution and development: engine-driven endodontic rotary nickel-titanium instruments.
International Journal of Oral Science 2022;14(1):12-12
Various engine-driven NiTi endodontic files have been indispensable and efficient tools in cleaning and shaping of root canals for practitioners. In this review, we introduce the relative terms and conceptions of NiTi file, including crystal phase composition, the design of the cutting part, types of separation. This review also analysis the main improvement and evolution of different generations of engine-driven nickel-titanium instruments in the past 20 years in the geometric design, manufacturing surface treatment such as electropolishing, thermal treatment, metallurgy. And the variety of motion modes of NiTi files to improve resistance to torsional failure were also discussed. Continuous advancements by the designers, provide better balance between shaping efficiency and resistance to of NiTi systems. In clinical practice an appropriate system should be selected based on the anatomy of the root canal, instrument characteristics, and operators' experience.
Dental Alloys/chemistry*
;
Dental Instruments
;
Equipment Design
;
Nickel/chemistry*
;
Root Canal Preparation
;
Titanium/chemistry*
8.Effect evaluation of different methods for removal of root canal filling materials.
Wenjun YANG ; Jiajia HAN ; Yichen WANG ; Fengxiang LI ; Qitao DU
West China Journal of Stomatology 2022;40(6):685-689
OBJECTIVES:
This study aimed to evaluate the efficacy of three methods in root canal retreatment to remove the filling material in the root canals.
METHODS:
Ninety tooth roots filled by gutta percha or plasticized material (n=45, each) were randomly divided into three groups (n=15). WaveOne (WaveOne group), 1#P drill+WaveOne (1#P+WaveOne group), and ultrasound P5 working end ET25+ProTaper Universal (P5+ProTaper Universal group) were used to remove the root canal filling material and prepare for root canal. The operating time of each canal was recorded and the percentage of residual filling material area was measured on the root canal wall of the mesial and distal dissected root section. The degree of deviation of the root canal after operation was measured for the root samples filled by gutta percha.
RESULTS:
The type of root filling material and the method of root canal retreatment had no significant effect on the percentage of residual area of the filling material (P>0.05). However, the remaining filling material area of apical 1/3 of the root canal was significantly higher than that of cervical 1/3 of the root canal (P<0.05). The average operating times for removing gutta-percha or plasticized material in the W and 1#P+WaveOne groups were significantly less than that in the P5+ProTaper Universal group (P=0.000). The root canal retreatment methods had no significant effect on the curvature of the root canal (P=0.650).
CONCLUSIONS
WaveOne single file's cleaning ability and center positioning ability were similar to those of ProTaper Universal. Moreover, WaveOne can be independently used for most root canals without a pathway when removing the root canal fillings, thereby simplifying the process of root canal retreatment.
Equipment Design
;
Gutta-Percha
;
Nickel
;
Root Canal Filling Materials
;
Root Canal Preparation/methods*
;
Titanium
9.Study of No Observed Adverse Effect Level of Nickel and Its Preliminary Evaluation Biocompatibility.
Xueying HE ; Juli TANG ; Xiantao WEN ; Bo GUAN ; Rui WANG ; Hui WANG ; Hua LI ; Jianfeng SHI ; Yali ZENG ; Yongjian MAO
Chinese Journal of Medical Instrumentation 2020;44(5):448-452
The purpose of this study was to investigate the NOAEL of the nickel ion and provide with basic data for the biological evaluation of those medical devices containing nickel. Five groups SD rats were repeatedly exposed during 14 d respectively to nickel at first stage doses of 4.9, 3.7, 2.5 mg/(kg.d), and the second stage doses of 1.2, 0.25 mg/(kg.d) by the intravenous route. The results showed that the NOAEL of nickel ion is 0.25 mg/(kg.d) for SD rats, and the result was verified by subchronic systemic toxicity test of nickel alloy. The threshold of toxicological concern (TTC) of nickel is 150 μg/d (based on application of 100-fold uncertainty factor and a body weight of 60 kg)deduced by these data.
Animals
;
Equipment and Supplies/adverse effects*
;
Nickel/toxicity*
;
No-Observed-Adverse-Effect Level
;
Rats
;
Rats, Sprague-Dawley
;
Risk Assessment
10.Safety performance of self-expandable NiTi alloy stent.
Zhiguo LI ; Wengang YAN ; Haiquan FENG
Journal of Biomedical Engineering 2020;37(2):334-339
In order to evaluate the safety performance of self-expandable NiTi alloy stents systematically, the dynamic safety factor drawn up by International Organization for Standardization, was used to quantitatively reflect the safety performance of stents. Based on the constitutive model of super-elastic memory alloy material in Abaqus and uniaxial tensile test data of NiTi alloy tube, finite element method and experiments on accelerated fatigue life were carried out to simulate the self-expansion process and the shape change process under the action of high and low blood pressure for three -type stents of 8×30 mm, 10×30 mm, 12×30 mm. By analyzing the changes of stress and strain of self-expanding NiTi alloy stent, the maximum stress and strain, stress concentration position, fatigue strength and possible failure modes were studied, thus the dynamic safety factor of stent was calculated. The results showed that the maximum stress and plastic strain of the stent increased with the increase of grip pressure, but the maximum stress and strain distribution area of the stent had no significant change, which were all concentrated in the inner arc between the support and the connector. The dynamic safety factors of the three stents were 1.31, 1.23 and 1.14, respectively, which indicates that the three stents have better safety and reliability, and can meet the fatigue life requirements of more than 10 years, and safety performance of the three stents decreases with the increase of stent's original diameter.
Alloys
;
Finite Element Analysis
;
Nickel
;
Reproducibility of Results
;
Self Expandable Metallic Stents
;
Stress, Mechanical
;
Titanium

Result Analysis
Print
Save
E-mail