1.Experimental study on injection completion rate and performance for needle-free insulin injection.
Yang ZHU ; Can KANG ; Wei CAI ; Chao HUANG
Journal of Biomedical Engineering 2025;42(1):181-188
As a relatively novel technique for drug delivery, the needle-free injection technique is characterized by transporting the drug liquid to the designated subcutaneous position through a high-speed micro-jet. Although this technique has been applied in many fields, the research on its drug dispersion mechanism and injection performance is insufficient. The presented study aims to identify critical parameters during the injection process and describe their influence on the injection effect. The injection completion rate and performance of a needle-free injector under various operating conditions were compared based on mouse experiments. The results show that the nozzle diameter imposes a more significant influence on jet characteristics than other injection parameters. Moreover, the injection completion rate increases with the nozzle diameter. The nozzle diameters of 0.14 mm and 0.25 mm correspond to injection completion rates of 89.7% and 95.8%, respectively. Furthermore, by analyzing the rate of blood glucose change in the tested mice, it is found that insulin administration through the needle-free injection can achieve a drug effect duration longer than 120 min, which is better than that obtained using conventional needle-syringe technique. In summary, the obtained conclusions can provide an important reference for the optimal design and extending application of the air-powered needle-free injector.
Animals
;
Mice
;
Insulin/administration & dosage*
;
Needles
;
Injections, Subcutaneous/methods*
;
Injections, Jet/instrumentation*
;
Drug Delivery Systems/instrumentation*
;
Blood Glucose/analysis*
;
Equipment Design
2.Research progress on the manufacturing technology of hollow microneedles.
Shengshuo ZHOU ; Huajian ZHOU ; Xiaoyu DU ; Ziye YU ; Tongle XU ; Shun ZHAO ; Peiqiang SU ; Leian ZHANG ; Guangyang FU ; Xuelei LIU
Journal of Biomedical Engineering 2025;42(2):423-430
Drug administration via hollow microneedles (HMN) have the advantages of painlessness, avoidance of first-pass effect, capability of sustained infusion, and no need for professional personnel operation. In addition, HMN can also be applied in the fields of body fluid extraction and biosensors, showing broad application prospects. However, traditional manufacturing technologies cannot meet the demand for low-cost mass production of HMN, limiting its widespread application. This paper reviews the main manufacturing technologies used for HMN in recent years, which include photolithography and etching, laser etching, sputtering and electroplating, micro-molding, three-dimensional (3D) printing and drawing lithography. It further analyzes the characteristics and limitations of existing manufacturing technologies and points out that the combination of various manufacturing technologies can improve production efficiency to a certain extent. In addition, this paper looks forward to the future trends of HMN manufacturing technology and proposes possible directions for its development. In conclusion, it is expected that this review can provide new ideas and references for follow-up research.
Printing, Three-Dimensional
;
Needles
;
Humans
;
Drug Delivery Systems/methods*
;
Equipment Design
;
Microinjections/methods*
3.Effects of acupuncture needle modification on acupuncture analgesia.
Ming-Zhu SUN ; Xin WANG ; Ying-Chen LI ; Yu-Hang LIU ; Yi YU ; Liu-Jie REN ; Wei GU ; Wei YAO
Journal of Integrative Medicine 2025;23(1):66-78
OBJECTIVE:
The analgesic effect of acupuncture has been widely accepted. Nevertheless, the mechanism behind its analgesic effect remains elusive, thus impeding the progress of research geared toward enhancing the analgesic effect of acupuncture. This paper investigated the role of acupuncture needle surface textures on acupuncture's analgesic effect by creating four experimental acupuncture needles with different patterns of surface augmentation.
METHODS:
Four types of acupuncture needles with different surface textures (the lined needle, circle needle, sandpaper needle, and threaded needle) were designed. Additionally, the force/torque measurement system used a robot arm and mechanical sensor to measure the force on the needle during insertion and manipulation. To perform acupuncture analgesia experiments, four experimental acupuncture needles and a normal needle were inserted into the Zusanli (ST36) acupoint of rats with inflammatory pain. By comparing the force and torque and the analgesic efficacy of the different acupuncture needles, these experiments tested the role of acupuncture needle body texture on acupuncture analgesia.
RESULTS:
The analgesic effects of different acupuncture needle body textures varied. Specifically, the force required to penetrate the skin with the lined needle was not greater than that for the normal needle; however, the needle with inscribed circles and the sandpaper-roughened needle both required greater force for insertion. Additionally, the torque of the lined needle reached 2 × 10-4 N·m under twisting manipulation, which was four times greater the torque of a normal needle (5 × 10-5 N·m). Furthermore, the lined needle improved pain threshold and mast cell degranulation rate compared to the normal needle.
CONCLUSION
Optimizing the texture of acupuncture needles can enhance acupuncture analgesia. The texture of our experimental acupuncture needles had a significant impact on the force needed to penetrate the skin and the torque needed to manipulate the needle; it was also linked to variable analgesic effects. This study provides a theoretical basis for enhancing the analgesic efficacy of acupuncture through the modification of needles and promoting the development of acupuncture therapy. Please cite this article as: Sun MZ, Wang X, Li YC, Liu YH, Yu Y, Ren LJ, Gu W, Yao W. Effects of acupuncture needle modification on acupuncture analgesia. J Integr Med. 2025; 23(1): 66-78.
Needles
;
Acupuncture Analgesia/methods*
;
Animals
;
Rats
;
Male
;
Acupuncture Points
;
Rats, Sprague-Dawley
4.Fabrication and evaluation of dexmedetomidine hydrochloride microneedles based on 3D printing.
Yuanke YANG ; Xiaolu HAN ; Xianfu LI ; Xiaoxuan HONG ; Shanshan YANG ; Chunyan LIU ; Zengming WANG ; Aiping ZHENG
Chinese Journal of Biotechnology 2025;41(8):3214-3227
Compared with conventional transdermal drug delivery systems, dissolving microneedles significantly enhance drug bioavailability by penetrating the stratum corneum barrier and achieving intradermal drug delivery. In order to improve the transdermal bioavailability of dexmedetomidine hydrochloride, in this study, a novel microneedle delivery system was developed for dexmedetomidine hydrochloride based on 3D printing combined with micro-molding. By systematically optimizing the microneedle geometrical parameters, array arrangement, and preparation process parameters, we determined the optimal ratio of drug-carrying matrix as 15% PVP (polyvinyl pyrrolidone) K90. The microneedles exhibited significant drug loading gradients, with mean content of (209.99±27.56) μg/patch, (405.31±30.31) μg/patch, and (621.61±34.43) μg/patch. They showed a regular pyramidal structure under SEM and handheld electron microscopy, and their mechanical strength allowed effective penetration into the stratum corneum. The surface contact angles were all < 90°, indicating excellent hydrophilicity. The microneedles dissolved completely within 10 min after skin insertion, achieving a cumulative release rate of 90% (Higuchi model, r=0.996) during 2 hours of in vitro transdermal permeation. The cytotoxicity test and hemolysis test verified good biocompatibility. Pharmacodynamic evaluation showed that the microneedle group demonstrated pain-relieving effect within 15 min, with the pain threshold at the time point of 60 min being 3 times that in the transdermal cream group. The microneedle system developed in this study not only offers an efficient drug delivery option for patients but also establishes an innovative platform for rapid percutaneous delivery of hydrophilic drugs, demonstrating significant potential in perioperative pain management.
Dexmedetomidine/pharmacokinetics*
;
Printing, Three-Dimensional
;
Needles
;
Drug Delivery Systems/methods*
;
Administration, Cutaneous
;
Animals
;
Microinjections/instrumentation*
;
Skin Absorption
;
Skin/metabolism*
5.Effectiveness of three-needle and two-cable structure in treatment of inferior patellar pole avulsion fractures.
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):686-691
OBJECTIVE:
To investigate the effectiveness of three-needle and two-cable structure in the treatment of inferior patellar pole avulsion fractures.
METHODS:
A clinical data of 62 patients with inferior patellar pole avulsion fractures who were admitted between January 2023 and December 2023 and met the selection criteria was retrospectively analyzed. Among them, the fractures were fixed with three-needle and two-cable structure in 32 patients (observation group) and traditional steel wire tension band in 30 cases (control group). There was no significant difference in the baseline data of age, gender, side of the affected limb, cause of injury, and disease duration between the two groups ( P>0.05). The operation time, fracture healing and healing time, patellar height (Insall-Salvati index), occurrence of complications, knee range of motion, and Böstman score at last follow-up were compared between the two groups.
RESULTS:
The operation time of the observation group was significantly shorter than that of the control group ( P<0.05). Patients in both groups were followed up 6-12 months (mean, 10.4 months). X-ray films re-examination showed that all fractures healed, and the fracture healing time was significantly shorter in observation group than in control group ( P<0.05); no significant difference was found in Insall-Salvati index between the two groups ( P>0.05). During follow-up, the complications occurred in 2 cases (6.25%) of observation group and in 9 cases (30.00%) of control group, and the difference in the incidences between the two groups was significant ( P<0.05). At last follow-up, the range of motion and Böstman score of the knee joint in observation group were significantly superior to control group ( P<0.05).
CONCLUSION
Compared with the traditional steel wire tension band fixation, the three-needle and two-cable structure fixation of the inferior patellar pole avulsion fractures is firm, which allows the knee joint to move early after operation and is conducive to the recovery of knee joint function.
Humans
;
Male
;
Patella/surgery*
;
Female
;
Fracture Fixation, Internal/instrumentation*
;
Retrospective Studies
;
Adult
;
Bone Wires
;
Fractures, Avulsion/surgery*
;
Middle Aged
;
Young Adult
;
Range of Motion, Articular
;
Treatment Outcome
;
Fracture Healing
;
Needles
;
Adolescent
;
Operative Time
6.Clinical study on Ilizarov technique combined with steel needle internal fixation for 12 patients with Charcot neuroarthropathy of foot and ankle.
Pu CHEN ; Hua GUAN ; Enhui FENG ; Jiachang LIANG ; Yiyin XU ; Jianbo HE ; Weiming HUANG ; Jiewei XIE
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(8):1008-1013
OBJECTIVE:
To evaluate the short-term effectiveness of Ilizarov technique combined with steel needle internal fixation in treating Charcot neuroarthropathy (CN) of the foot and ankle.
METHODS:
Between June 2020 and December 2023, 12 patients with Eichenholtz stage Ⅲ CN of the foot and ankle were treated with Ilizarov technique and steel needle internal fixation. There were 9 males and 3 females with an average age of 48.6 years (range, 19-66 years). The disease duration ranged from 1 to 16 months (mean, 6.8 months). Ankle joint involvement predominated in 7 cases, while midfoot involvement occurred in 5 cases; 3 cases presented with skin ulceration and soft tissue infection. Preoperative American Orthopedic Foot and Ankle Society (AOFAS) score was 31.2±9.0, 36-Item Short-Form Health Survey (SF-36)-Physical Component Summary (PCS) score was 32.6±6.8, and Mental Component Summary (MCS) score was 47.8±8.4. Postoperative assessments included wound healing, regular X-ray film/CT evaluations of fusion status, and effectiveness via AOFAS and SF-36-PCS, MCS scores.
RESULTS:
All operations were successfully completed without neurovascular complication. Two patients experienced delayed wound healing requiring intervention, and the others achieved primary healing. All patients were followed up 15-43 months (mean, 23.3 months). Imaging confirmed successful joint fusion within 13-21 weeks (mean, 16.8 weeks). At last follow-up, the AOFAS score was 72.5±6.4, and the SF-36-PCS and MCS scores were 63.2±8.4 and 76.7±5.3, respectively, all of which improved compared to preoperative levels, with significant differences ( P<0.05).
CONCLUSION
Ilizarov technique combined with steel needle internal fixation effectively restores walking function and achieves satisfactory short-term effectiveness in CN of the foot and ankle.
Humans
;
Middle Aged
;
Male
;
Female
;
Adult
;
Ilizarov Technique
;
Arthropathy, Neurogenic/surgery*
;
Aged
;
Ankle Joint/surgery*
;
Treatment Outcome
;
Needles
;
Fracture Fixation, Internal/instrumentation*
;
Steel
;
Young Adult
;
Foot Joints/surgery*
7.Meta-analysis of Kirschner's needle and elastic intramedullary nail fixation for the treatment of proximal humeral fractures in children.
Tao SHI ; Zi-Hang XU ; Xin ZHANG ; Yu-Wang QIAN ; Lei ZHU ; Lai-Fa KONG
China Journal of Orthopaedics and Traumatology 2025;38(6):633-640
OBJECTIVE:
To systematically evaluated clinical efficacy of Kirschner's needle and elastic intramedullary nail fixation in treating proximal humeral fractures in children by Meta-analysis.
METHODS:
Literature on the treatment of proximal humeral fractures in children with Kirschler needles and elastic intramedullary nails published on Wanfang, VIP, CNKI and China biology medicine (CBM), PubMed, Embase, and Web of Science databases were searched from the establishment of databases to October, 2023. Literature extraction, management and data entry were performed by Endnote X9 and Excel 2019, and Meta-analysis was conducted by RevMan 5.3 software. The operation time, hospital stay, fracture healing time, shoulder joint extension range of motion, disabilities of arm, shoulder and hand(DASH) questionnaire score, Neer score or Constant-Murley score and complications were compared between two groups.
RESULTS:
A total of 7 literatures were included, 1 was prospective study, 6 were retrospective cohort study. There were 521 children, 264 children in Kirschner wire group and 257 children in elastic intramedullary nail fixation group. The results of Meta analysis showed operation time[WMD=-12.61, 95%CI(-24.89, -0.33), P=0.04], fracture healing time[WMD=-0.26, 95%CI(-0.49, -0.02), P=0.03], total complication rate [OR=6.83, 95%CI(3.33, 14.01), P<0.001], nail tract infection rate[OR=6.77, 95%CI(1.72, 26.69), P=0.006] and displacement fracture rate[OR=3.57, 95%CI(1.35, 9.44), P=0.01] between two groups had statistically differences(P>0.05), while there were no statistically significant difference in comparison of hospital stay, shoulder joint extension range of motion, DASH, Neer score, Constant-Murley score, and incidence of skin irritation between two groups (P>0.05).
CONCLUSION
Kirschner's needle internal fixation has a short operation time and simple operation, but it has a higher incidence of complications compared with elastic nail internal fixation technique. In terms of efficacy and safety, elastic intramedullary nail fixation is one of the options for the treatment of proximal humeral fractures in children.
Humans
;
Fracture Fixation, Intramedullary/instrumentation*
;
Child
;
Shoulder Fractures/physiopathology*
;
Bone Nails
;
Bone Wires
;
Male
;
Needles
;
Female
8.Thyroid tuberculosis with papillary thyroid carcinoma in a 19 year-old female.
Ji-ilhan L. Banawol ; Ronaldo G. Soriano
Philippine Journal of Otolaryngology Head and Neck Surgery 2025;40(Supplement):33-35
OBJECTIVES
To discuss a case of papillary thyroid carcinoma with concomitant thyroid tuberculosisin terms of clinical presentation and treatment.
METHODSDesign:Case Report
Setting:Tertiary Government Training Hospital
Patient:One
RESULTSA 19-year-old Filipina consulted with a four-year history of a left thyroid nodule. She was clinically euthyroid with unremarkable systemic examination. Fine needle aspiration cytology (FNAC) was suspicious for malignancy and she underwent total thyroidectomy. Histopathology revealed papillary thyroid carcinoma of the left lobe, microcarcinoma of the isthmus and incidental note of tuberculosis (TB) of the right lobe. Management included oral anti-TB medications and surveillance.
CONCLUSIONA 19-year-old Filipina consulted with a four-year history of a left thyroid nodule. She was clinically euthyroid with unremarkable systemic examination. Fine needle aspiration cytology (FNAC) was suspicious for malignancy and she underwent total thyroidectomy. Histopathology revealed papillary thyroid carcinoma of the left lobe, microcarcinoma of the isthmus and incidental note of tuberculosis (TB) of the right lobe. Management included oral anti-TB medications and surveillance.
Human ; Female ; Young Adult: 19-24 Yrs Old ; Carcinoma ; Thyroid Cancer, Papillary ; Thyroid Neoplasms ; Thyroid Gland ; Thyroidectomy ; Thyroid Nodule ; Government ; Needles ; Hospitals ; Research Report
9.Giant pleomorphic adenoma in a 64-Year-old woman: A case report.
Mark Laurence B. Barrios ; Neil Aldrine I. Penaflor
Philippine Journal of Otolaryngology Head and Neck Surgery 2025;40(Supplement):41-44
OBJECTIVES
To report a case of a giant pleomorphic adenoma in a 64-year-old Filipino woman, its management and surgical outcome.
METHODSDesign:Case Report
Setting:Tertiary Government Training Hospital
Patient: One
RESULTSA 64-year-old woman presented with a 50-year history of a slow growing, painless, left infra-auricular mass, not associated with facial weakness, xerostomia, or hearing loss. Computed tomography revealed a 14 x 15 x 19 cm large lobulated complex enhancing mass with calcifications and septations, with no enlarged lymph nodes identified in the neck. Fine needle aspiration cytomorphology was consistent with pleomorphic adenoma. The patient underwent superficial parotidectomy with facial nerve preservation. The facial nerve was identified using standard landmarks. Final histopathological findings were consistent with pleomorphic adenoma measuring 23.5 cm x 11.5 cm x 15 cm and weighing 2177 grams
CONCLUSIONPleomorphic adenoma can grow to a gigantic size if left untreated. It often presents as a chronic, slow growing and painless swelling. The approach to its diagnosis is mainly clinical and can be confirmed by fine needle aspiration biopsy and computed tomography scan. In our case, the standard landmarks for facial nerve identification were still reliable despite the size of the mass, producing good post-surgical outcomes.
Human ; Female ; Middle Aged: 45-64 Yrs Old ; Adenoma ; Lymph ; Needles ; Diagnosis ; Xerostomia ; Hearing Loss ; Neck ; Research Report ; Tomography ; Facial Nerve
10.Qihuang needle therapy for autism spectrum disorder with sleep disorder: a multi-center randomized controlled trial.
Bingxu JIN ; Qizhen LIU ; Jiahao TANG ; Yong ZHAO ; Jing XIN ; Yuan ZHOU ; Haiyan CAI ; Zhanxin HUO ; Xiaohong CHEN ; Yan BAI
Chinese Acupuncture & Moxibustion 2025;45(3):322-326
OBJECTIVE:
To observe the clinical efficacy of Qihuang needle therapy for autism spectrum disorder (ASD) children with sleep disorder.
METHODS:
A total of 60 ASD children with sleep disorder were randomly divided into an observation group and a control group, 30 cases in each group. Both groups were treated with structured education intervention, 60 min each time, once a day, 6 times a week. Qihuang needle therapy was applied at Yintang (GV24+), Baihui (GV20) and bilateral Jueyinshu (BL14), Xinshu (BL15) in the observation group, multi-direction needling was delivered and without needle retaining. The treatment was given 2 times a week, each treatment was delivered at interval of 2 days at least. Behavioral intervention was adopted in the control group. Treatment for consecutive 12 weeks was required in both groups. Before and after treatment, the scores of children's sleep habits questionnaire (CSHQ), the autism behavior checklist (ABC), the childhood autism rating scale (CARS), and the childhood autism behavior scale (CABS) were observed in the two groups.
RESULTS:
After treatment, the scores of CSHQ, ABC, CARS and CABS were decreased compared with those before treatment (P<0.01), and the above scores in the observation group were lower than those in the control group (P<0.05).
CONCLUSION
Qihuang needle therapy can effectively treat ASD with sleep disorder, improve the core symptoms of ASD and the sleep quality.
Humans
;
Autism Spectrum Disorder/physiopathology*
;
Male
;
Female
;
Child
;
Sleep Wake Disorders/physiopathology*
;
Child, Preschool
;
Acupuncture Therapy
;
Acupuncture Points
;
Treatment Outcome
;
Sleep
;
Needles


Result Analysis
Print
Save
E-mail