1.Difference of Parental Level of Concerns on Surgery according to the Perspectives and Characteristic among Pediatrics with Intermittent Exotropia
Seongyong JEONG ; So Young HAN ; Sunghyuk MOON ; Donghun LEE ; Sook Young KIM ; Mirae KIM ; Jihyun PARK ; Myung Mi KIM ; Won Jae KIM
Korean Journal of Ophthalmology 2025;39(1):41-47
Purpose:
To evaluate the differences in the level of concerns regarding exotropia surgery according to the perspectives regarding surgery and basic characteristics of parents of pediatric patients with intermittent exotropia in South Korea.
Methods:
This study included the parents of pediatric patients with intermittent exotropia who underwent surgery at five hospitals, between June 2022 and February 2023. Parental perspectives, basic characteristics, and levels of concern regarding surgery were assessed using a questionnaire. We investigated the differences in concern levels according to perspectives regarding surgery and basic characteristics among parents, such as sex, age, residential area, and the most influential factors in the decision-making for surgery.
Results:
A total of 266 parents were included (228 mothers; age, 40.0±4.7 years). Parents who chose surgery for subjective symptoms had higher levels of concern about hemorrhage, conjunctival redness, and persistent overcorrection than did those who chose surgery for cosmetic reasons (all p < 0.05). Fathers were more concerned about postoperative pain, compared to mothers (p = 0.039). Parents in their 40s and 50s had higher levels of concern about the hospital environment compared with those in their 20s and 30s (p = 0.003). Concern did not significantly differ by residential area.
Conclusions
The level of concern regarding surgery differed according to the perspectives and characteristics of the parents of pediatric patients with intermittent exotropia. Parents who chose surgery for subjective symptoms of exotropia had a higher level of concern than did those who chose surgery for cosmetic reasons. The concern level differed according to the parents’ sex and age but not their residential area.
2.Effect of 50-Hz Filters on Pattern Electroretinogram
Dong Hee HA ; Nam Ju MOON ; Ungsoo Samuel KIM
Korean Journal of Ophthalmology 2025;39(3):241-245
Purpose:
Pattern electroretinogram (PERG) is used to evaluate the function of retinal ganglion cells. However, the amplitude of PERG is quite small, making the examination challenging to perform. Waveform noise may be minimized by applying various filters. We aimed to investigate the effect of 50-Hz filters on PERG test results.
Methods:
This is the retrospective observational study. PERG tests were performed using the RETI-scan system according to the International Society for Clinical Electrophysiology of Vision guidelines. Three types of 50-Hz filters (soft, middle, and hard) were applied. The differences in parameters (N35 peak time, P50 peak time, N95 peak time, P50 amplitude, N95 amplitude, and N95 to P50 ratio) were analyzed. Based on the provided normal range, the changes from normal to abnormal range or vice versa were investigated.
Results:
A total of 24 waveforms were analyzed. After filtering, the P50 and N95 amplitudes showed a significant reduction of 8% to 15% (P50 amplitude: 5.1 ± 2.7 μV without filter, 4.6 ± 2.3 μV with 50-Hz soft filter, 4.3 ± 2.1 μV with 50-Hz middle filter, 4.3 ± 2.1 μV with 50-Hz hard filter; N95 amplitude: 7.2 ± 4.2 μV without filter, 6.6 ± 3.8 μV with 50-Hz soft filter, 6.3 ± 3.6 μV with 50-Hz middle filter, 6.1 ± 3.6 μV with 50-Hz hard filter). This pattern was more prominent in normal subjects. All latencies except the N35 peak time exhibited no differences between the tests. The N95 to P50 ratio decreased after 50-Hz middle and hard filtering. Considering the normative data, switching between normal and abnormal results was rare.
Conclusions
Although peak time was not significantly affected, amplitude was significantly reduced after using 50-Hz filters. Thus, 50-Hz filters can smoothen the waveform. Nevertheless, caution must be exercised while taking readings.
3.Evaluation of the Popper Test as an Alternative to the Valsalva Maneuver for Assessing Eustachian Tube Function
Dae Hyun KIM ; Moon Su KWAK ; Ju Ha PARK ; Seong Hoon BAE
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(2):58-61
Background and Objectives:
The Valsalva test, although commonly utilized to assess the Eustachian tube function, is limited by drawbacks such as inconsistent pressure increases in the nasal cavity. Thus we introduced the “Popper test,” a tympanic membrane inflation test using the automatic middle ear inflation device known as middle ear inflation device (MEID), to explore its viability as an alternative to the Valsalva test.Subjects and Method We sampled 80 ears from patients between June 1, 2023, and August 1, 2023. Each patient underwent both the Valsalva and Popper tests using the MEID. Participants were divided into three categories: the “unable” group (patients who could not follow the Valsalva maneuver) and the “successful” and “unsuccessful” groups (patients whose attempts at the Valsalva or Popper tests either successed or failed). Success or failure was determined using an otoscope to assess the bulging of the tympanic membrane.
Results:
Of the 68 ears with normal middle ear pressure, 30.9% (21 ears) showed an inability to perform the Valsalva test, 45.6% (31 ears) successfully inflated the tympanic membrane via the Valsalva test, and 23.5% (16 ears) failed. Conversely, the Popper test resulted in an 88.2% (60 ears) success rate for inflating the tympanic membrane, with only 11.8% (8 ears) failing.
Conclusion
Variability observed in the Valsalva test outcomes may be attributed to individual differences and the instructor’s technique. MEID, as utilized in the Popper test, offers a promising alternative to the Valsalva test, potentially enhancing the reliability by minimizing individual variation. However, the diagnostic performance may be dependent on the properties of the MEID.
4.Deep Learning-Accelerated Non-Contrast Abbreviated Liver MRI for Detecting Malignant Focal Hepatic Lesions: Dual-Center Validation
So Hyun PARK ; Moon Hyung CHOI ; Bohyun KIM ; Hyun-Soo LEE ; Sungjin YOON ; Young Joon LEE ; Dominik NICKEL ; Thomas BENKERT
Korean Journal of Radiology 2025;26(4):333-345
Objective:
To compare a deep learning (DL)-accelerated non-enhanced abbreviated MRI (AMRI DL) protocol with standard AMRI (AMRI STD) of the liver in terms of image quality and malignant focal lesion detection.
Materials and Methods:
This retrospective study included 155 consecutive patients (110 male; mean age 62.4 ± 11 years) from two sites who underwent standard liver MRI and additional AMRIDL sequences, specifically DL-accelerated single-shot fast-spin echo (SSFSE DL) and DL-accelerated diffusion-weighted imaging (DWIDL). Additional MRI phantom experiments assessed signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) values. Three reviewers evaluated AMRIDL and AMRI STD protocols for image quality using a five-point Likert scale and identified malignant hepatic lesions. Image quality scores and per-lesion sensitivities were compared between AMRIDL and AMRI STD using the Wilcoxon signed-rank test and logistic regression with generalized estimating equations, respectively.
Results:
Phantom experiments demonstrated comparable SNR and higher CNR for SSFSE DL compared to SSFSE STD, with similar ADC values for DWIDL and DWI STD. Among the 155 patients, 130 (83.9%) had chronic liver disease or a history of intra- or extrahepatic malignancy. Of 104 malignant focal lesions in 64 patients, 58 (55.8%) were hepatocellular carcinomas (HCCs), 38 (36.5%) were metastases, four (3.8%) were cholangiocarcinomas, and four (3.8%) were lymphomas. The pooled per-lesion sensitivity across three readers was 97.6% for AMRIDL, comparable to 97.6% for AMRI STD. Compared with AMRI STD, AMRIDL demonstrated superior image quality regarding structural sharpness, artifacts, and noise (all P < 0.001) and reduced the average scan time by approximately 50% (2 min 29 sec vs. 4 min 11 sec). In patients with chronic liver disease, AMRIDL achieved a 96.6% per-lesion sensitivity for HCC detection, similar to 96.5% for AMRI STD (P > 0.05).
Conclusion
The AMRIDL protocol offers comparable sensitivity for detecting malignant focal lesions, including HCC while significantly enhancing image quality and reducing scan time by approximately 50% compared to AMRI STD.
5.Evaluation of Image Quality and Scan Time Efficiency in Accelerated 3D T1-Weighted Pediatric Brain MRI Using Deep Learning-Based Reconstruction
Hyunsuk YOO ; Hee Eun MOON ; Soojin KIM ; Da Hee KIM ; Young Hun CHOI ; Jeong-Eun CHEON ; Joon Sung LEE ; Seunghyun LEE
Korean Journal of Radiology 2025;26(2):180-192
Objective:
This study evaluated the effect of an accelerated three-dimensional (3D) T1-weighted pediatric brain MRI protocol using a deep learning (DL)-based reconstruction algorithm on scan time and image quality.
Materials and Methods:
This retrospective study included 46 pediatric patients who underwent conventional and accelerated, pre- and post-contrast, 3D T1-weighted brain MRI using a 3T scanner (SIGNA Premier; GE HealthCare) at a single tertiary referral center between March 1, 2023, and April 30, 2023. Conventional scans were reconstructed using intensity Filter A (Conv), whereas accelerated scans were reconstructed using intensity Filter A (Fast_A) and a DL-based algorithm (Fast_DL).Image quality was assessed quantitatively based on the coefficient of variation, relative contrast, apparent signal-to-noise ratio (aSNR), and apparent contrast-to-noise ratio (aCNR) and qualitatively according to radiologists’ ratings of overall image quality, artifacts, noisiness, gray-white matter differentiation, and lesion conspicuity.
Results:
The acquisition times for the pre- and post-contrast scans were 191 and 135 seconds, respectively, for the conventional scan. With the accelerated protocol, these were reduced to 135 and 80 seconds, achieving time reductions of 29.3% and 40.7%, respectively. DL-based reconstruction significantly reduced the coefficient of variation, improved the aSNR, aCNR, and overall image quality, and reduced the number of artifacts compared with the conventional acquisition method (all P < 0.05). However, the lesion conspicuity remained similar between the two protocols.
Conclusion
Utilizing a DL-based reconstruction algorithm in accelerated 3D T1-weighted pediatric brain MRI can significantly shorten the acquisition time, enhance image quality, and reduce artifacts, making it a viable option for pediatric imaging.
6.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
7.Structural and Functional Brain Changes Following Electroconvulsive Therapy in Patients With Schizophrenia: A Literature Review
Korean Journal of Schizophrenia Research 2025;28(1):11-18
This review synthesizes research findings on the structural and functional brain changes observed after electroconvulsive therapy (ECT) in patients with schizophrenia. Structural neuroimaging studies suggest that the hippocampus, amygdala, and right insular cortex are the most critical areas implicated in ECT-related changes for these patients. Functional neuroimaging studies also highlight the involvement of the hippocampus, amygdala, and insular cortex, along with the prefrontal cortex, default mode network, and thalamostriatal system. We examine and discuss the potential implications of these incorporated findings. Given the relative scarcity of related studies, further research is needed to elucidate the mechanisms underlying the effects of ECT in patients with schizophrenia.
8.Method-Based Proficiency Test Program for Assessing Quality of Sanger Sequencing-Based Molecular Tests
Moon-Woo SEONG ; Ho-bin SUNG ; Jee-Soo LEE
Journal of Laboratory Medicine and Quality Assurance 2025;47(1):28-31
Background:
Sanger sequencing is a technology used to identify the gene sequence variants causing rare genetic disorders. However, designing and implementing a proficiency scheme for Sanger sequencing-based genetic testing is challenging because many molecular diagnostic laboratories are running sequencing tests for tens to hundreds of target genes. As such, we aimed to design and implement a method-based proficiency testing (PT) method for Sanger sequencing and to assess its feasibility in Korea.
Methods:
A pathogenic low density lipoprotein receptor (LDLR) variant was chosen as the positive PT material, and material without an LDLR variant was used as the negative PT material. We distributed the two PT materials with primer pair sets to 17 molecular diagnostic laboratories nationwide.We calculated the correct results (%) for variation type, zygosity, nucleotide change, amino acid change, variant classification, and clinical interpretation.
Results:
Fourteen laboratories responded to the survey. The results for the two PT materials were 100% correct for all evaluation points including variant type, zygosity, nucleotide change, amino acid change, variant classification, and clinical interpretation.
Conclusions
This pilot PT survey demonstrates a feasibility of using method-based PT for assessing the Sanger sequencing performance of molecular diagnostic laboratories in Korea.
9.Factors Associated with Suicide Risk among the Elderly Living Alone in Jeju, Korea
Hae-Joo AHN ; Moon-Doo KIM ; Hyun-Ju YANG
Mood and Emotion 2025;23(1):1-10
Background:
The growing number of elderly individuals living alone presents a major social issue, encompassing loneliness, isolation, economic and health challenges, and increased risk of suicide. This study aimed to identify factors associated with suicide risk among elderly individuals living alone in Jeju.
Methods:
A total of 4,742 participants completed questionnaires to assess their sociodemographic characteristics. Depressive symptoms were evaluated using the Short Form Geriatric Depression Scale-Korean version (sGDS-K), with a cutoff score of eight indicating the presence of depressive symptoms. Suicide risk was assessed using the MiniInternational Neuropsychiatric Interview-Plus. Multivariate logistic regression analysis was performed to identify significant correlates of suicide risk.
Results:
Multivariate logistic regression analysis identified the following factors as significantly associated with suicide risk: poor subjective health status (odds ratio [OR]=1.590, 95% confidence interval [CI]: 1.137-2.224), current drinking (OR=1.511, 95% CI: 1.119-2.042), hypertension (OR=1.419, 95% CI: 1.133-1.778), and sGDS scores ≥8 (OR=4.318, 95% CI: 3.408-5.469).
Conclusion
This study highlights the importance of intensive mental health services and socioeconomic support in preventing suicide among elderly individuals living alone. Targeted interventions should focus on those who have poor subjective health status, are current drinkers, have hypertension, or exhibit depressive symptoms.
10.Nuclear Medicine Imaging in Differentiated Thyroid Cancer: Summary of the Korean Thyroid Association Guidelines 2024 from Nuclear Medicine Perspective, Part‑I
So Won OH ; Sohyun PARK ; Ari CHONG ; Keunyoung KIM ; Ji‑In BANG ; Youngduk SEO ; Chae Moon HONG ; Sang‑Woo LEE
Nuclear Medicine and Molecular Imaging 2025;59(1):1-7
Thyroid cancer, one of the most common endocrine tumors, generally has a favorable prognosis but remains a significant medical and societal concern due to its high incidence. Early diagnosis and treatment of differentiated thyroid cancer (DTC) significantly affect long-term outcomes, requiring the selection and application of appropriate initial treatments to improve prognosis and quality of life. Recent advances in technology and health information systems have enhanced our understanding of the molecular genetics of thyroid cancer, facilitating the identification of aggressive subgroups and enabling the accumulation of research on risk factors through big data. The Korean Thyroid Association (KTA) has revised the “KTA Guidelines on the Management of Differentiated Thyroid Cancers 2024” to incorporate these advances, which were developed by a multidisciplinary team and underwent extensive review and approval processes by various academic societies. This article summarizes the 2024 KTA guidelines for nuclear medicine imaging in patients with DTC, written by the Nuclear Medicine members of the KTA Guideline Committee, and covers 18 F-FDG PET/CT and radioiodine imaging with SPECT/CT in the management of DTC.

Result Analysis
Print
Save
E-mail