1.Utilization of in silico-designed primers for SARS-CoV-2 molecular surveillance using Direct PCR Product Sequencing Surveillance (DPPSS) method.
Sarah Jane DATAY-LIM ; Flyndon Mark DAGALEA ; Michael Reigh GUEVARRA ; Kristine AVILA ; Kim Claudette FERNANDEZ ; Francisco HERALDE III
Philippine Journal of Pathology 2026;11(1):12-19
BACKGROUND
The COVID-19 pandemic caused by SARS-CoV-2 significantly strained healthcare systems in the Philippines, highlighting the critical importance of reliable molecular diagnostics and genomic surveillance. Although vaccination efforts and public health measures mitigated disease impact, the continued emergence of viral variants underscores the need for sustainable local surveillance strategies. Strengthening in-country capacity through the development of in silico–designed primers and cost-effective sequencing approaches can enhance rapid variant detection and improve preparedness for future emerging infectious diseases.
OBJECTIVEThis paper offers a method in detecting the SARS-CoV-2 virus and its variants. A direct PCR product sequencing surveillance or DPPSS offers a new possibility of detecting emerging disease by using PCR products and using it as templates in determining the base sequence.
METHODOLOGYA total of 20 random positive samples for SARS-COV-2 from March 2022 sample pool in Metro Manila, Philippines was used in this study. The RNA was extracted using Purelink™ RNA Mini Kit, quantified with NanoDrop, and subjected to one-step RT-PCR. An in-house designed in silico primers were used in this study by using thermodynamic parameters to optimize specificity and amplification efficiency, considering GC contents, balanced Tm, minimal secondary structures and cross-dimers and in silico validation via Basic Local Alignment Search Tool (BLAST) against reference databases.
Amplicons were analyzed through gel electrophoresis, sequenced, and analyzed using BioEdit software. A nucleotide BLAST search identified COVID-19 variants, confirmed using Cov-Lineages website.
RESULTSIn silico designed primers (S1, S2, E/M, Orf1ab) collectively exhibited 100% sensitivity in detecting SARS-CoV2 in nasopharyngeal swab samples. Individual primer sensitivities varied, with Orf1ab at 58.82% and E/M at 90.91%. Our analysis revealed the prevalence of Omicron sublineage BA.2 in the Philippines, aligning with local data showing more BA.2 cases than the global predominance of BA.1.
CONCLUSIONCombined in silico primers (S1, S2, E/M, ORF1ab) accurately detect SARS-COV-2 and its variants. This method provides a valuable diagnostic and surveillance tool for public health management.
Covid-19 ; Polymerase Chain Reaction ; Molecular Diagnostic Techniques
2.Cytology Smears of Rapid On-site Evaluation as Supplemental Material for Molecular Testing of Non-small Cell Lung Cancer.
Shiqi TANG ; Chunli TANG ; Zeyun LIN ; Juhong JIANG
Chinese Journal of Lung Cancer 2024;26(12):910-918
BACKGROUND:
The thoracic small biopsy sampling procedure including transbronchial forceps lung biopsy (TBLB) and endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) can be accompanied by rapid on-site evaluation (ROSE) of sample material to provide immediate feedback for the proceduralist. The present study aims to investigate the supplemental effect of ROSE smear samples for lung cancer molecular test.
METHODS:
In a retrospective study, 308 patients admitted to our hospital from August 2020 to December 2022 undergoing diagnostic TBLB and EBUS-TBNA with ROSE and subsequently diagnosed as non-small cell lung cancer (NSCLC) were analyzed. The matched formalin-fixed paraffin-embedding (FFPE) tissue section and ROSE smears for tumor cellularity were compared. DNA yields of smears were determined. Real-time polymerase chain reaction (PCR) and next-generation sequencing (NGS) were performed on adequate smear samples.
RESULTS:
ROSE smear samples were enriched in tumor cells. Among 308 biopsy samples, 78 cases (25.3%) exhibited inadequate FFPE tissue sections, whereas 44 cases (14.3%) yielded adequate smear samples. Somatic mutations detected in the FFPE tissue section samples were also detected in the matching adequate smear sample.
CONCLUSIONS
ROSE smear samples of the thoracic small biopsies are beneficial supplemental materials for ancillary testing of lung cancer. Combined use of cytology smear samples with traditional FFPE section samples can enhance the detection rate of informative mutations in patients with advanced NSCLC. We recommend that the laboratory could further evaluate the ROSE cell smears of the patient when FFPE tissue sections are inadequate, and that adequate cell smears can be used as a supplemental source for the molecular testing of NSCLC.
Humans
;
Carcinoma, Non-Small-Cell Lung/pathology*
;
Lung Neoplasms/pathology*
;
Rapid On-site Evaluation
;
Retrospective Studies
;
Molecular Diagnostic Techniques
;
Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods*
3.Molecular diagnostics of prostate cancer: impact of molecular tests.
Asian Journal of Andrology 2024;26(6):562-566
Prostate cancer (PCa) is the second leading cause of cancer-related death among men. Prostate-specific antigen (PSA) testing is used in screening programs for early detection with a consequent reduction of PCa-specific mortality at the cost of overdiagnosis and overtreatment of the nonaggressive PCa. Recently, several assays have been commercially developed to implement PCa diagnosis, but they have not been included in both screening and diagnosis of PCa. This review aims to describe the actual and novel commercially available molecular biomarkers that can be used in PCa management to implement and tailor the screening and diagnosis of PCa.
Humans
;
Prostatic Neoplasms/genetics*
;
Male
;
Biomarkers, Tumor/genetics*
;
Early Detection of Cancer/methods*
;
Prostate-Specific Antigen/blood*
;
Molecular Diagnostic Techniques/methods*
;
Glutamate Carboxypeptidase II/metabolism*
6.Diagnostic values of cyclin D1 immunocytochemistry and molecular testing in preoperative fine needle aspiration of undeterminate thyroid nodules.
Shu Rong HE ; Jing Xin ZHANG ; Rong Ming CHEN ; Song Tao HU ; Li YANG ; Lan CHEN ; Zheng ZHANG ; Dong Ge LIU
Chinese Journal of Pathology 2022;51(12):1210-1216
Objective: To assess the value of cyclin D1 immunocytochemistry combined with a small panel molecular analysis in indeterminate cytological diagnosis of Bethesda category Ⅲ-Ⅴ. Methods: A consecutive cohort of 96 thyroid FNA specimens with indeterminate diagnosis (TBSRTC category Ⅲ-Ⅴ) and available histopathologic follow-up data were collected between December 2018 and December 2021 in Department of Pathology, Beijing Hospital. The cases were evaluated by cyclin D1 immunocytochemistry and molecular testing of BRAFV600E or a small panel of markers (BRAF, N-RAS, H-RAS, K-RAS and TERT) in the FNA specimens. The identification of the optimal cut-off point of cyclin D1 for the diagnosis of malignancy was evaluated using the receiver operating characteristic (ROC) curves and the assessment of the area under the ROC curve (AUC). The specificity, sensitivity, positive predictive value (PPV) and negative predictive value (NPV) of all these markers were evaluated with the crosstabs and significance was calculated. Results: Ninty-six patients with 96 thyroid nodules were enrolled, including 42 cases of TBSRTC-III, 10 cases of TBSRTC-IV and 44 cases of TBSRTC-V. There were 79 females and 17 males with a median age of 47 years (range, 25 to 75 years). A 7.5% cut-off value for positive cyclin D1 nuclear immunostaining in thyroid cells demonstrated 100% PPV, 57.1% NPV, 81.0% sensitivity and 100% specificity for thyroid malignancy diagnosis. The sensitivity of the BRAFV600E mutation test or combined with a small panel test alone for thyroid malignancy diagnosis were 65.5% and 69.0% respectively. The sensitivity for thyroid malignancy diagnosis increased to 94.0% and 95.2% respectively when combining the cyclin D1 immunocytochemistry with the molecular test, and the specificities remained 100% and 91.7% respectively.The accuracy of cyclin D1 immunocytochemistry combined with a small panel of molecular test in detecting thyroid malignancy increased to 94.8% compared to using these markers alone. Conclusions: The addition of cyclin D1 immunocytochemistry and a small panel of molecular testing to FNA cytology can increase the sensitivity and NPV of cytology in indeterminate categories, and this supplementary approach provides a simple, accurate and convenient diagnostic method for reducing unnecessary thyroidectomies.
Adult
;
Aged
;
Humans
;
Middle Aged
;
Biopsy, Fine-Needle
;
Cyclin D1/genetics*
;
Molecular Diagnostic Techniques
;
Thyroid Nodule/genetics*
;
Male
;
Female
7.Evaluation of Multidrug Resistant Loop-mediated Isothermal Amplification Assay for Detecting the Drug Resistance of
Chun Fa LIU ; Yi Meng SONG ; Ping HE ; Dong Xin LIU ; Wen Cong HE ; Yan Ming LI ; Yan Lin ZHAO
Biomedical and Environmental Sciences 2021;34(8):616-622
Objective:
To evaluate multidrug resistant loop-mediated isothermal amplification (MDR-LAMP) assay for the early diagnosis of multidrug-resistant tuberculosis and to compare the mutation patterns associated with the
Methods:
MDR-LAMP assay was evaluated using 100
Results:
The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDR-LAMP were 85.5%, 93.6%, 96.7%, and 74.4% for the detection of resistance to isoniazid and rifampicin, respectively, and 80.5%, 92.3%, 98.6%, and 41.4% for the detection of
Conclusion
MDR-LAMP is a rapid and accessible assay for the laboratory identification of rifampicin and isoniazid resistance of
Antitubercular Agents
;
Bacterial Proteins/genetics*
;
Catalase/genetics*
;
DNA, Bacterial/analysis*
;
DNA-Directed RNA Polymerases/genetics*
;
Drug Resistance, Multiple, Bacterial/genetics*
;
Isoniazid
;
Molecular Diagnostic Techniques/methods*
;
Mutation
;
Mycobacterium tuberculosis/isolation & purification*
;
Nucleic Acid Amplification Techniques/methods*
;
Oxidoreductases/genetics*
;
Phenotype
;
Rifampin
;
Whole Genome Sequencing
8.Disseminated double-hit lymphoma in a young adult
Karen Damian ; Jonathan Emmanuel Cancio
Philippine Journal of Pathology 2021;6(1):56-61
High-grade B-cell lymphoma with MYC and BCL2 and-or BCL6 rearrangements, also called double-hit lymphoma, is an aggressive mature B-cell lymphoma that carries both MYC and BCL2 and/or BCL6 translocations. This can present as a diagnostic challenge since clinical characteristics, morphology and immunophenotype are not accurate indicators of underlying genetic aberrations in this type of lymphoma. We report a case of a 25-year-old male who presented with a one-year history of cough, gradually increasing abdominal girth and jaundice. Definitive diagnosis was made post-mortem with additional ancillary studies using immunohistochemistry staining and fluorescent in-situ hybridization studies.
Lymphoma
;
Lymphoma, B-Cell
;
Molecular Diagnostic Techniques
9.Establishment of fluorescence immunochromatography detection for cytoskeleton-associated protein 4.
Lu ZHANG ; Yunlong WANG ; Yulin LI ; Jichuang WANG ; Yinyin YU ; Heng ZHANG ; Yiqing ZHANG ; Lei CHENG ; Shoutao ZHANG
Chinese Journal of Biotechnology 2020;36(6):1216-1222
A rapid and simple method to detect tumor markers in liver cancer was established by combining immunochromatography technique with fluorescent microsphere labeling. According to the principle of double antibody sandwich, the cytoskeleton-associated protein 4 (CKAP4) paired antibody was used as the labeled and coated antibody, and the goat anti-rabbit polyclonal antibody was used as the quality control line coated antibody in the preparation of the CKAP4 fluorescent immunochromatographic test strips. After the preparation, the test strips were evaluated on various performance indicators, such as linearity, precision and stability. The CKAP4 immunochromatographic strip prepared by time-resolved fluorescent microspheres had high sensitivity, and good specificity. Its precision was within 15%, recovery between 85% and 115%, and linear range between 25 and 1 000 pg/mL. The test strip could be kept stable at 37 °C for 20 days, and it correlated well with commercial ELISA kits. The CKAP4 fluorescence immunochromatography method can quantitatively detect the content of CKAP4 in serum. Furthermore, it is rapid, sensitive, simple, economical and single-person operation. This method has the potential of becoming a new method for the diagnosis and treatment of liver cancer.
Animals
;
Antibodies
;
metabolism
;
Chromatography, Affinity
;
Fluorescence
;
Humans
;
Liver Neoplasms
;
diagnosis
;
Membrane Proteins
;
isolation & purification
;
Molecular Diagnostic Techniques
;
instrumentation
;
methods
;
Sensitivity and Specificity
10.Application of Microfluidics in Molecular Diagnostics.
Chao WANG ; Dongfeng ZHANG ; Liuqing YANG ; Yaoji LIU ; Yue WU
Chinese Journal of Medical Instrumentation 2020;44(6):520-524
In recent years, molecular diagnostics has been the most promising branch of
Humans
;
Microfluidics
;
Molecular Diagnostic Techniques/instrumentation*
;
Pathology, Molecular/instrumentation*


Result Analysis
Print
Save
E-mail