1.Effect of icariin-containing serum on lipopolysaccharide-induced inflammatory damage in human chondrocytes
Linzhen LI ; Hongzhuo JIAO ; Weinan CHEN ; Mingzhe ZHANG ; Jianlong WANG ; Juntao ZHANG
Chinese Journal of Tissue Engineering Research 2026;30(6):1368-1374
BACKGROUND:Previous studies of the research group have found that icariin-containing serum can delay the progression of knee osteoarthritis,promote chondrocyte proliferation and stem cell cartilage differentiation in rats,but there is still a lack of sufficient basis for clinical application.OBJECTIVE:To investigate the repair effect of icariin-containing serum on lipopolysaccharide-induced inflammatory damage of human chondrocytes.METHODS:The effect of icariin-containing serum on chondrocyte viability was detected by cell counting kit-8 method,and the optimal volume fraction and time of icariin-containing serum were screened.The cells were then divided into blank group,lipopolysaccharide group,icariin-containing serum group and lipopolysaccharide+icariin-containing serum group.After grouping,immunofluorescence was used to detect the secretion of type Ⅱ collagen in chondrocytes in each group.Real-time PCR was used to detect the expression of related genes.RESULTS AND CONCLUSION:(1)Icariin-containing serum showed good biosafety characteristics for human chondrocytes,and the cell viability reached the highest level after 48 hours of intervention when the icariin-containing serum volume fraction was 15%,and the follow-up experiments were carried out according to the conditions.(2)Compared with the blank group,lipopolysaccharide significantly inhibited the expression of type Ⅱ collagen in chondrocytes,while icariin-containing serum showed a positive mobilization effect,which could effectively promote the secretion of type Ⅱ collagen in chondrocytes under normal and inflammatory conditions.(3)The mRNA expression of type Ⅱ collagen and Aggrecan in chondrocytes decreased significantly under lipopolysaccharide stimulation,and the mRNA expression levels of matrix metalloproteinase 13 and a disintegrin-like and metalloproteinase with thrombospondin motifs-5 increased significantly.Icariin-containing serum promoted the mRNA expression of type Ⅱ collagen in human chondrocytes under inflammatory conditions and reduced the mRNA expression of matrix metalloproteinase 13 and a disintegrin-like and metalloproteinase with thrombospondin motifs-5 in chondrocytes after lipopolysaccharide intervention.Therefore,these findings indicate that the icariin-containing serum has good safety for human chondrocytes and plays an important role in maintaining the normal physiological functions of chondrocytes,promoting the synthesis of extracellular matrix,and inhibiting the secretion of inflammatory factors.
2.Effect of icariin-containing serum on lipopolysaccharide-induced inflammatory damage in human chondrocytes
Linzhen LI ; Hongzhuo JIAO ; Weinan CHEN ; Mingzhe ZHANG ; Jianlong WANG ; Juntao ZHANG
Chinese Journal of Tissue Engineering Research 2026;30(6):1368-1374
BACKGROUND:Previous studies of the research group have found that icariin-containing serum can delay the progression of knee osteoarthritis,promote chondrocyte proliferation and stem cell cartilage differentiation in rats,but there is still a lack of sufficient basis for clinical application.OBJECTIVE:To investigate the repair effect of icariin-containing serum on lipopolysaccharide-induced inflammatory damage of human chondrocytes.METHODS:The effect of icariin-containing serum on chondrocyte viability was detected by cell counting kit-8 method,and the optimal volume fraction and time of icariin-containing serum were screened.The cells were then divided into blank group,lipopolysaccharide group,icariin-containing serum group and lipopolysaccharide+icariin-containing serum group.After grouping,immunofluorescence was used to detect the secretion of type Ⅱ collagen in chondrocytes in each group.Real-time PCR was used to detect the expression of related genes.RESULTS AND CONCLUSION:(1)Icariin-containing serum showed good biosafety characteristics for human chondrocytes,and the cell viability reached the highest level after 48 hours of intervention when the icariin-containing serum volume fraction was 15%,and the follow-up experiments were carried out according to the conditions.(2)Compared with the blank group,lipopolysaccharide significantly inhibited the expression of type Ⅱ collagen in chondrocytes,while icariin-containing serum showed a positive mobilization effect,which could effectively promote the secretion of type Ⅱ collagen in chondrocytes under normal and inflammatory conditions.(3)The mRNA expression of type Ⅱ collagen and Aggrecan in chondrocytes decreased significantly under lipopolysaccharide stimulation,and the mRNA expression levels of matrix metalloproteinase 13 and a disintegrin-like and metalloproteinase with thrombospondin motifs-5 increased significantly.Icariin-containing serum promoted the mRNA expression of type Ⅱ collagen in human chondrocytes under inflammatory conditions and reduced the mRNA expression of matrix metalloproteinase 13 and a disintegrin-like and metalloproteinase with thrombospondin motifs-5 in chondrocytes after lipopolysaccharide intervention.Therefore,these findings indicate that the icariin-containing serum has good safety for human chondrocytes and plays an important role in maintaining the normal physiological functions of chondrocytes,promoting the synthesis of extracellular matrix,and inhibiting the secretion of inflammatory factors.
3.Preparation and osteogenic properties of liquid crystal display light-cured polylactic acid scaffold loaded with nano-tantalum
Mingzhe LI ; Xiangling YE ; Bing WANG ; Xiang YU
Chinese Journal of Tissue Engineering Research 2025;29(4):670-677
BACKGROUND:Polylactic acid(PLA)has good biocompatibility and a controllable degradation rate and is currently widely used in biomedical engineering.However,PLA has shortcomings such as low mechanical strength and insufficient biological activity,which limits its further application in bone tissue engineering. OBJECTIVE:To construct polylactic acid/polydopamine/tantalum(PLA/PDA/Ta)bone tissue engineering scaffolds,and explore their biosafety and in vitro osteogenesis. METHODS:A PLA scaffold with a porous structure was prepared through liquid crystal display light-curing technology.PLA/PDA scaffolds and PLA/PDA/Ta scaffolds were prepared by soaking PLA scaffolds in dopamine solution and dopamine-tantalum nanoparticle solution,respectively.The microstructure and water contact angle of scaffolds were characterized.MC3T3-E1 cells were co-cultured with PLA,PLA/PDA,and PLA/PDA/Ta scaffolds,respectively,and CCK-8 assay and live/dead cell staining were performed.After osteogenic differentiation,alkaline phosphatase,alizarin red staining,and osteogenic gene detection were performed. RESULTS AND CONCLUSION:(1)The scanning electron microscope results exhibited that the three kinds of prepared scaffolds had an interconnected porous three-dimensional structure,and the average pore diameter was 200 μm.The water contact angle of PLA/PDA/Ta scaffolds was lower than that of PLA and PLA/PDA scaffolds(P<0.05).(2)CCK-8 assay showed that compared with PLA and PLA/PDA scaffolds,PLA/PDA/Ta scaffolds could promote cell proliferation(P<0.05).Live/dead cell staining showed good cell proliferation in the three groups.(3)Alkaline phosphatase and alizarin red staining showed that compared with PLA and PLA/PDA scaffolds,PLA/PDA/Ta scaffolds could promote the expression of alkaline phosphatase and the formation of mineralized nodules.RT-qPCR showed that compared with PLA and PLA/PDA scaffolds,PLA/PDA/Ta scaffolds could enhance the mRNA expression of cell bone morphogenetic protein,Runx-2,and type I collagen(P<0.05,P<0.01).(4)The results showed that the PLA/PDA/Ta scaffold had excellent osteogenic activity and the ability to promote cell proliferation.
4.Exploration on the Protective Effects and Mechanisms of Modified Shenqi Dihuang Decoction on Podocytes in db/db Mice Based on ROS/NLRP3/GSDMD Signaling Pathway
Guiyan SUN ; Mingzhe LI ; Yan SHI ; Xiaoyan ZHUANG ; Xiaonan DUAN ; Moyan ZHANG ; Zhihan LEI ; Chunhui ZHANG ; Guanqi YANG ; Yufeng YANG ; Jing LYU
Chinese Journal of Information on Traditional Chinese Medicine 2025;32(11):123-132
Objective To explore the protective effect and possible mechanism of modified Shenqi Dihuang Decoction on podocytes in db/db mice based on ROS/NLRP3/GSDMD signaling pathway.Methods Fifty 8-week-old male db/db mice(SPF grade)were randomly divided into the model group,losartan group and TCM low-,medium-and high-dosage groups,with 10 mice in each group.Ten heterozygous db/m mice served as the blank group.Interventions were administered respectively for 12 weeks.The body mass,random blood glucose,serum creatinine,blood urea nitrogen and 24 h urinary protein content were detected,HE,PAS,PASM,Masson and Sirius red staining was used to observe the morphology of renal tissue,transmission electron microscopy was used to observe the ultrastructure of renal tissue,fluorescent probes were used to observe the release of ROS in renal tissue,immunofluorescence staining was used to detect the expression of Nephrin,NLRP3,Cleaved Caspase-1 and GSDMD-N in renal tissue,and Western blot was used to detect the expression of NLRP3,Cleaved Caspase-1,GSDMD-N,IL-1β,IL-18,Nephrin,Podocin,PODXL,WT-1 and Desmin proteins.Results Compared with the blank group,the body mass and random blood glucose of the model group mice significantly increased(P<0.05),and the contents of serum creatinine,blood urea nitrogen and 24 h urinary protein were significantly increased(P<0.05);glomerular hypertrophy,dilation of renal glomeruli and tubules,thickening of basement membrane,matrix proliferation in mesangial area,abnormal deposition of collagen fibers in renal interstitium,accompanied by damage to renal tubular epithelial structure and focal glomerulosclerosis,significant increase in type Ⅰ collagen deposition,extensive fusion of podocyte processes,and scattered electron dense material in the basement membrane or subepithelial layer;the ROS content in renal tissue significantly increased(P<0.05),and the protein expression of NLRP3,Cleaved Caspase-1,GSDMD-N,IL-1β,IL-18 and Desmin significantly increased(P<0.05),the protein expression of Nephrin,Podocin,PODXL and WT1 significantly decreased(P<0.05).Compared with the model group,the body mass and random blood glucose of mice in each dosage of TCM group were relatively stable,the contents of serum creatinine,blood urea nitrogen and 24 h urinary protein decreased;the pathological damage to renal tissue was reduced,the ultrastructure of podocytes was improved,and the density of podocytes increased;the ROS content decreased,and the protein expression of NLRP3,Cleaved Caspase-1,GSDMD-N,IL-1β,IL-18 and Desmin decreased,while the protein expression of Nephrin,Podocin,WT1 and PODXL increased.With the dosage of modified Shenqi Dihuang Decoction increased,the improvement effect gradually strengthened,and the differences in TCM high-dose group was statistically significant(P<0.05).Conclusion Modified Shenqi Dihuang Decoction can protects podocytes in db/db mice,potentially by modulating the ROS/NLRP3/GSDMD signaling pathway.
5.Robot system-assisted versus freehand screw revision for ankylosing spondylitis with lower cervical fractures: a multicenter retrospective study
Shuai LI ; Jiaojiao BAI ; Baorong HE ; Yanzheng GAO ; Wei MEI ; Xinyu LIU ; Yue ZHU ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhigang ZHAO ; Yunfei HUANG ; Jinpeng DU ; Mingzhe FENG ; Ningbo CHEN ; Yansheng HUANG ; Xuefang ZHANG ; Zhen CHANG
Chinese Journal of Trauma 2025;41(5):440-448
Objective:To compare the efficacy of robot system-assisted versus freehand screw revision for ankylosing spondylitis (AS) with lower cervical fractures.Methods:A multicenter retrospective cohort study was conducted to analyze the clinical data of 57 patients with AS combined with lower cervical fractures admitted to Honghui Hospital Affiliated to Xi'an Jiaotong University School of Medicine, Henan Provincial People's Hospital, Zhengzhou Orthopedic Hospital, and Qilu Hospital of Shandong University, including 46 males and 11 females, aged 38-77 years [(65.4±9.5)years]. Injury segments involved C 3 in 7 patients, C 4 in 13, C 5 in 25, C 6 in 10, and C 7 in 2. All the patients underwent revision surgery, among whom, 22 patients were treated with robot system-assisted cervical pedicle screw placement (robot nailing group, with 190 screws), and 35 with freehand cervical pedicle screw placement (freehand nailing group, with 300 screws). The operative duration, intraoperative bleeding volume, frequency of intraoperative fluoroscopy, incision length, and length of hospital stay of the two groups were compared; the time of single nscrew insertion, the number of single nail revisions, the distance between screws and the anterior cortex, the accuracy of screw placement of grade 0 and grade 0+1 were recorded in the two groups. The visual analogue scale (VAS), Japanese Orthopedic Society (JOA) score, neck dysfunction index (NDI), American Spine Injury Association (ASIA) classification before operation, at 3 days, 3 months after operation and at the last follow-up were compared between the two groups. The complication rate was also noted. Results:All the patients were followed up for 12-16 months [(14.3±2.1)months]. The operative duration, intraoperative bleeding volume, and frequency of intraoperative fluoroscopy were (186.4±12.9)minutes, (486.1±68.6)ml, and (3.4±1.3)times in the robot nailing group, which were shorter or less than (206.7±14.4)minutes, (660.3±45.2)ml, and (13.5±3.6)times in the freehand nailing group ( P<0.01). The incision length was (9.4±2.4)cm in the robot nailing group, longer than (5.6±1.2)cm in the freehand nailing group ( P<0.01), and the length of hospital stay was (3.7±0.4)days, shorter than (4.4±1.4)days in the freehand nailing group ( P<0.01). The length of single nail insertion, the number of single nail revision, and the distance between the screws and the front cortex were (6.5±0.4)minutes, (1.1±0.1)times, and (3.5±1.3)mm in the robot nailing group, which were shorter or less than (11.6±0.2)minutes, (1.5±0.2)times, and (12.4±4.7)mm in the freehand nailing group ( P<0.01). The accuracy of the screw placement in the robot nailing group was 90.0% (171/190) and 95.8% (182/190) with level 0 and 0+1 screws, better than 80.0% (240/300) and 89.0% (267/300) in the freehand nailing group ( P<0.05). There was no significant difference in VAS, JOA score, NDI, or ASIA grading between the two groups before operation ( P>0.05). The VAS, JOA, and NDI scores at 3 days after operation were (3.1±0.6)points, (12.1±1.2)points, and (15.6±2.9)points, respectively in the robot nailing group, which were better than (5.0±1.4)points, (11.3±1.1)points and (22.5±3.7)points, respectively in the freehand nailing group ( P<0.05). No statistically significant difference was observed in the ASIA grade between the two groups at 3 days after operation ( P>0.05). There were no significant differences in VAS, JOA, NDI scores, or ASIA grading between the two groups at 3 months after operation and at the last follow-up ( P>0.05). Compared with those before operation, the VAS, JOA, NDI scores, and ASIA grading were significantly improved at 3 days, 3 months after operation and at the last follow-up in the two groups, which were further improved with the passage of time. Two patients in the robot nailing group had pneumonia, with a complication rate of 9% (2/22), while 2 patients in the freehand nailing group had dural sac rupture and cerebrospinal fluid leakage and 3 had lung infection after operation, with a complication rate of 14% (5/35) ( P<0.05). Conclusion:Compared with freehand nailing, the robot system-assisted nailing revision for AS with lower cervical fracture has more advantages in terms of the operative duration, length of hospital stay, intraoperative bleeding volume, frequency of intraoperative fluoroscopy nailing speed and accuracy, screw holding force, early pain relief, function restoration, and complication rate, despite longer surgical incision.
6.Comparative efficacy of navigation system and orthopedic robot-assisted nail placement in the treatment of lower cervical fracture and dislocation
Xinnan CHENG ; Shuai LI ; Jiaojiao BAI ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhen CHANG ; Zhigang ZHAO ; Yunfei HUANG ; Mingzhe FENG ; Liang YAN ; Hua HUI ; Lingbo KONG ; Baorong HE
Chinese Journal of Trauma 2025;41(2):148-156
Objective:To compare the clinical efficacy of navigation system and orthopedic robot-assisted nail placement in the treatment of lower cervical fracture and dislocation.Methods:A retrospective cohort study was conducted to analyze the clinical data of 49 patients with fracture and dislocation of the lower cervical spine who were admitted to Honghui Hospital, Xi′an Jiaotong University School of Medicine from May 2021 to October 2022, including 38 males and 11 females, aged 29-61 years [(39.3±7.3)years]. Injury segments involved C 3 in 12 patients, C 4 in 11, C 5 in 8, C 6 in 9 and C 7 in 9. Twenty-one patients were treated with S8 navigation system (navigation group, 84 screws), and 28 with TINAVI orthopedic robot (robot group, 112 screws). The two groups were compared in terms of the total surgical duration, single screw placement time, total screw placement time, distance between the screw and the anterior cortex, incision length, intraoperative radiation dose, intraoperative blood loss and length of hospital stay. The height of intervertebral space, Cobb angle, sliding distance between vertebral bodies and American Spinal Injury Association (ASIA) grade were assessed before surgery and at 3 days after surgery. Visual analogue scale (VAS), Japanese Orthopedic Association (JOA) score and neck dysfunction index (NDI) before surgery, at 3 days, 3 months after surgery and at the last follow-up were compared. The accuracy of screw placement, intraoperative invasion rate of adjacent facet joints and rate of postoperative complications (infection, screw loosening, etc.) were evaluated. Results:All the patients were followed up for 12-16 months [(13.6±1.9)months]. In the navigation group, the total surgical duration, distance from the screw to the anterior cortex and the intraoperative radiation dose were (236.2±30.6)minutes, (2.0±0.2)mm and (374.3±90.3)mGy respectively, which were significantly shorter or less than those in the robot group [(278.4±20.7)minutes, (10.6±2.9)mm and (448.4±77.9)mGy] ( P<0.01). The single screw placement time, total screw placement time, incision length and intraoperative blood loss were (3.5±0.4)minutes, (23.9±0.5)minutes, (9.1±2.4)cm and (422.2±30.4)ml respectively, which were significantly longer or more than those in the robot group [(2.6±0.2)minutes, (17.9±0.7)minutes, (6.6±2.6)cm and (360.3±56.3)ml] ( P<0.01). There was no significant difference in the length of hospital stay between the two groups ( P>0.05). No significant differences were observed in the height of the intervertebral space, Cobb angle, sliding distance between the vertebral bodies and ASIA grade between the two groups ( P>0.05). At 3 days after surgery, the height of intervertebral space, Cobb angle, sliding distance between vertebral bodies and ASIA grade in both groups were significantly improved when compared with those before surgery ( P<0.05 or 0.01). There were no significant differences in VAS, JOA scores or NDI between the two groups before surgery, at 3 days, 3 months after surgery and at the last follow-up ( P>0.05). The VAS, JOA scores and NDI in both groups were gradually improved at 3 days, 3 months and at the last follow-up after surgery when compared with those before surgery ( P<0.05). There was no significant difference in the accuracy of screw placement of levels 0 and 0+1 between the two groups ( P>0.05). No significant difference in the intraoperative invasion rate of adjacent facet joints between the two groups was found ( P>0.05). There were no serious complications such as infection or screw loosening after surgery in both groups. Conclusions:For lower cervical fracture and dislocation, although there are more advantages in total surgical duration, screw holding force and radiation control regarding the navigation system, and more outstanding performance in screw placement efficiency, incision length and intraoperative blood loss regarding the orthopedic robot, both of them can effectively rebuild the cervical structure, improve neurological function, relieve postoperative pain, improve screw placement accuracy and reduce facet joint injury and serious complications. Selection of the best auxiliary screw placement system should comprehensively consider patients′ conditions and the experience of the surgical team.
7.Integrating explainable deep learning with multi-omics for screening progressive diagnostic biomarkers of hepatocellular carcinoma covering the "inflammation-cancer" transformation.
Saiyu LI ; Yiwen ZHANG ; Lifang GUAN ; Yijing DONG ; Mingzhe ZHANG ; Qian ZHANG ; Huarong XU ; Wei XIAO ; Zhenzhong WANG ; Yan CUI ; Qing LI
Journal of Pharmaceutical Analysis 2025;15(9):101253-101253
Image 1.
8.Probucol combined with tirofiban for angina pectoris in patients with coronary heart disease after interventional surgery
Alatenqimuge ; Wangliang ZHU ; Bo YU ; Jianfei LI ; Xin QIAO ; Mingzhe SONG ; Dongye YUN
Journal of Interventional Radiology 2025;34(6):579-583
Objective To discuss the effect of probucol combined with tirofiban treatment on serum lipid peroxide levels and vascular endothelial function in patients with angina pectoris after interventional surgery of coronary heart disease(CHD).Methods A total of 120 patients with angina pectoris occurring after interventional surgery from January 2018 to December 2022 at the People's Hospital of Inner Mongolia Autonomous Region of China were enrolled in this study.Using random digital table method,the patients were divided into observation group(n=60)and control group(n=60).The patients of the control group received tirofiban,while the patients of the observation group received tirofiban plus probucol.All the preoperative and postoperative 7-day relevant indicators were recorded.The main observation indicator was the overall effective rate,and the secondary observation indicators included the frequency and duration of angina attacks,Seattle Angina Questionnaire(SAQ)score,cardiac function,myocardial injury markers,serum lipid peroxide levels,endothelial function and adverse reactions.Results The total effective rate in the observation group was 91.67%(55/60),which was higher than 78.33%(47/60)in the control group,the difference was statistically significant(P<0.05).After treatment,the improvement degree of angina pectoris,SAQ score,LVEF,serum superoxide dismutase(SOD),nitric oxide(NO)in the observation group were higher than those in the control group,while the LVESD,LVEDD,serum creatine kinase isozyme(CK-MB),lactate dehydrogenase(LDH),creatine kinase(CK),malondialdehyde(MDA),endothelin-1(ET-1)in the observation group were lower than those in the control group,the differences in the above indexes were statistically significant(all P<0.05).Conclusion For patients with angina pectoris occurring after interventional surgery of CHD,probucol combined with tirofiban has exact efficacy,which can promote the recovery of cardiac function,reduce myocardial injury,regulate serum lipid peroxide levels,and improve vascular endothelial function.
9.Study on the short- and mid-term clinical efficacy of covered stents in the treatment of transplanted renal artery stenosis
Danghui LU ; Kun LI ; Dongbin ZHANG ; Kewei ZHANG ; Mingzhe CUI ; Shuiting ZHAI ; Guoquan WANG
Chinese Journal of Radiology 2025;59(8):937-941
Objective:To explore the short- and medium-term clinical outcomes of covered stent implantation in the treatment of transplant renal artery stenosis (TRAS).Methods:A retrospective analysis was conducted on the clinical data of 12 consecutive patients with TRAS (transplant renal artery stenosis) who underwent covered stent implantation in Henan Provincial People′s Hospital from January 2021 to December 2024. The changes in indicators such as serum creatinine (Cr), blood urea nitrogen (BUN), mean arterial pressure (MAP), peak systolic velocity (PSV), intrarenal resistance index (RI), and the diameter of the stenotic site were analyzed before the operation, one week after the operation, six months after the operation, and 12 months after the operation. Repeated measures analysis of variance was used to investigate the changes of each observation index over time.Results:The surgery was successfully performed on all 12 patients, with a technical success rate of 100%. Among them, 8 cases used self-expanding covered stents, and 4 cases used balloon-expandable covered stents. One week, six months and twelve months after the surgery, the levels of Cr, BUN, PSV and MAP were all lower than those before the surgery. The RI and the diameter of the stenotic site were significantly increased compared with those before the surgery, the difference was statistically significant ( P<0.05). During the perioperative period and the postoperative follow-up period, no surgery-related complications were found. Conclusion:The implantation of the covered stent can effectively relieve the stenosis of the transplant renal artery, significantly improve renal function, and reduce blood pressure levels in TRAS patients, while maintaining excellent short-to medium-term clinical outcomes.
10.Study on the correlation factors of autologous hematopoietic stem cell mobilization and the predictive value of platelet counts in patients with hematologic tumors
Li CHEN ; Mingzhe ZHAO ; Tingjun ZHU ; Bingtian XIA ; Lulu LI
China Modern Doctor 2025;63(13):33-36
Objective To analyze the factors influencing the mobilization and collection of peripheral blood hematopoietic stem cells in patients with hematologic tumors,and to explore the predictive value of platelet counts in the process of autologous stem cell collection.Methods A total of 52 patients with hematologic tumors who underwent autologous hematopoietic stem cell transplantation in Affiliated Jinhua Hospital,Zhejiang University School of Medicine from September 2018 to March 2024 were selected.Binary Logistic regression analysis was used to explore the influencing factors of peripheral blood stem cell collection,and receiver operating characteristic(ROC)curve was used to determine the optimal cut-off value of platelet counts before collection.Results Among the 52 patients,36 patients had high-quality mobilization and 16 patients had non-high-quality mobilization.The number of chemotherapy cycles before collection and mobilization plan had significant effects on the number of CD34+cells collected,while age,gender,collection machine,and bone marrow involvement had no significant effects on the number of CD34+cells collected.The platelet counts in high-quality mobilization group were significantly higher than those in non-high-quality mobilization group(P<0.05).Binary Logistic regression analysis showed that platelet counts before collection had a significant effect on the collection of peripheral blood stem cells(OR=0.975,95%CI:0.954-0.997,P=0.025).ROC curve results showed that the area under the curve of platelet counts prediction of stem cell quality collection was 0.732,the optimal cut-off value was 86×109/L,the sensitivity was 72.2%,and the specificity was 81.2%.Subgroup analysis showed that platelet transfusion had no significant effect on the number of CD34+cells.Conclusion The number of chemotherapy cycles before collection and mobilization plan can affect the number of autologous hematopoietic stem cells.The platelet counts before collection can help determine the best time for collection and improve the success rate of collection.

Result Analysis
Print
Save
E-mail