1.Research progress of technology in femtosecond laser assisted cataract surgery
Daosen ZHANG ; Haifeng CAO ; Mingxing WU ; Yuehong WANG ; Gangping ZHAO ; Hui ZHOU
International Eye Science 2025;25(9):1436-1440
Cataract is the world's leading cause of blindness, and surgery is the most effective treatment for cataract. With the development of femtosecond laser technology and ophthalmic surgical equipment, the application of femtosecond laser systems in cataract surgery is becoming increasingly widespread. It can be used in cataract surgery for corneal incisions, anterior capsulotomy, lens fragmentation, arcuate incisions and other key operations. Compared to traditional surgery, femtosecond laser assisted cataract surgery(FLACS)offers significant advantages in precision, safety and postoperative visual outcomes. Its clinical benefits have garnered growing recognition among ophthalmologists. However, the key technologies and high-precision equipment for FLACS remain predominantly controlled by Western countries. In China, the research in this field began later. This article reviews the technological advancements in FLACS, with a focus on femtosecond laser technology, optical coherence tomography(OCT), artificial intelligence, and clinical application progress. The objective is to provide theoretical foundations and practical insights for the development of ophthalmic medical technology in China.
2.Literature research on acupoint prescriptions for acupuncture and moxibustion in the prevention of aerospace depression syndrome
Kaiyuan DENG ; Yawen TAO ; Yingdong WANG ; Yidan XU ; Qiang XI ; Jiwen QIU ; Xinju LI ; Ruonan LIANG ; Yi YU ; Hao LIU ; Peng ZHOU ; Mingxing ZHANG ; Yi GUO
Space Medicine & Medical Engineering 2025;36(4):305-311
Under the influence of long-term space flights and the confined space environment,it is very easy to induce space depression syndrome,mainly manifested as decreased emotional stability,sleep disorders,mental fatigue,etc.,which seriously affect the living conditions and working abilities of astronauts.The current treatment methods mainly focus on psychological support and drug intervention.Acupuncture has a good effect in treating depression.Therefore,starting from the TCM pathogenesis and modern medical pathogenesis of aerospace depression syndrome,we conducted literature retrieval from databases such as the Chinese Medical Classic,China National Knowledge Infrastructure(CNKI),Wanfang,VIP,PubMed,and Web of science.For the included literature,we adopted the stratified evidence scoring method and combined the TCM mechanism and modern medical mechanism of the effect of acupuncture.A prescription for acupuncture points was constructed to provide a basis for selecting acupuncture points for the prevention of aerospace depression syndrome through acupuncture.
3.The research on effects of transcutaneous electrical acupoint stimulation on muscle strength reserve of calf muscles
Guoning HAN ; Yawen TAO ; Zheng ZHU ; Yingdong WANG ; Mingxing ZHANG ; Qiang XI ; Dan ZHOU ; Yi GUO ; Peng ZHOU ; Xin NIU ; Lin ZHANG ; Jiwen QIU
Space Medicine & Medical Engineering 2025;36(4):356-361
Objective To investigate whether transcutaneous electrical acupoint stimulation(TEAS)can improve the muscle strength,endurance and work efficiency of calf muscles in healthy young men,aiming to explore a new method for preventing and combating microgravity-induced muscle atrophy in space environments.Methods 40 healthy young men aged 18-35 years were randomly divided into a Control group(Pseudo Transcutaneous Electrical Acupoint Stimulation)and a Experimental group(Transcutaneous Electrical Acupoint Stimulation)in a 1∶1 ratio,with 20 participants in each group.In the Control group,the indicator light of the stimulator was covered,and the device was turned on,but the electrodes did not contact the skin,The device automatically turned offafter 3 seconds.In the Experimental group,the TEAS device was connected to the current and TEAS intervention was performed.The electrical stimulation waveform was a sperse-dense wave with a frequency of 4/20 Hz,and the intensity was determined by patient tolerance.The acupoints selected for electrical stimulation in both groups were bilateral Zusanli(ST36)、Liangqiu(ST34),Taixi(KI3),and Fuliu(KI7).Zusanli and Liangqiu were paired,and Taixi and Fuliu were paired.The intervention frequency was 30 min/time,1 time/day,6 days/week,for 2 weeks.The relative peak torque at 60°/s,relative peak torque at 180°/s,and average power at 180°/s of the bilateral calf muscles were measured using an isokinetic dynamometer at 0th,7th,and 14d day of the experiment.Results After 1 week of TEAS,compared with Control group,there were no significant changes in the relative peak torque at 60°/s,relative peak torque at 180°/s and average power at 180°/s of the bilateral anterior calf muscles in the Experimental group(all P>0.05);however,compared with Control group,the relative peak torque at 60°/s and the relative peak torque at 180°/s of the bilateral posterior calf muscles in the Experimental group were significantly increased(all P<0.05).After 2 weeks TEAS;compared with the Control group,there were no significant changes in the relative peak torque at 60°/s,relative peak torque at 180°/s and average power at 180°/s of the bilateral anterior calf muscles in the Experimental group(all P>0.05);however,the relative peak torque at 60°/s,relative peak torque at 180°/s,and average power at 180°/s of the bilateral posterior calf muscles were significantly increased in the Experimental group(all P<0.05).Conclusion TEAS of Zusanli,Liangqiu,Fuliu and Taixi acupoints on the lower limbs for 2 weeks can effectively improve the maximum muscle strength,endurance and work efficiency of the posterior calf muscles in healthy young men.
4.Reference values of carotid intima-media thickness and arterial stiffness in Chinese adults based on ultrasound radio frequency signal: A nationwide, multicenter study
Changyang XING ; Xiujing XIE ; Yu WU ; Lei XU ; Xiangping GUAN ; Fan LI ; Xiaojun ZHAN ; Hengli YANG ; Jinsong LI ; Qi ZHOU ; Yuming MU ; Qing ZHOU ; Yunchuan DING ; Yingli WANG ; Xiangzhu WANG ; Yu ZHENG ; Xiaofeng SUN ; Hua LI ; Chaoxue ZHANG ; Cheng ZHAO ; Shaodong QIU ; Guozhen YAN ; Hong YANG ; Yinjuan MAO ; Weiwei ZHAN ; Chunyan MA ; Ying GU ; Wu CHEN ; Mingxing XIE ; Tianan JIANG ; Lijun YUAN
Chinese Medical Journal 2024;137(15):1802-1810
Background::Carotid intima-media thickness (IMT) and diameter, stiffness, and wave reflections, are independent and important clinical biomarkers and risk predictors for cardiovascular diseases. The purpose of the present study was to establish nationwide reference values of carotid properties for healthy Chinese adults and to explore potential clinical determinants.Methods::A total of 3053 healthy Han Chinese adults (1922 women) aged 18-79 years were enrolled at 28 collaborating tertiary centers throughout China between April 2021 and July 2022. The real-time tracking of common carotid artery walls was achieved by the radio frequency (RF) ultrasound system. The IMT, diameter, compliance coefficient, β stiffness, local pulse wave velocity (PWV), local systolic blood pressure, augmented pressure (AP), and augmentation index (AIx) were then automatically measured and reported. Data were stratified by age groups and sex. The relationships between age and carotid property parameters were analyzed by Jonckheere-Terpstra test and simple linear regressions. The major clinical determinants of carotid properties were identified by Pearson’s correlation, multiple linear regression, and analyses of covariance.Results::All the parameters of carotid properties demonstrated significantly age-related trajectories. Women showed thinner IMT, smaller carotid diameter, larger AP, and AIx than men. The β stiffness and PWV were significantly higher in men than women before forties, but the differences reversed after that. The increase rate of carotid IMT (5.5 μm/year in women and 5.8 μm/year in men) and diameter (0.03 mm/year in both men and women) were similar between men and women. For the stiffness and wave reflections, women showed significantly larger age-related variations than men as demonstrated by steeper regression slopes (all P for age by sex interaction <0.05). The blood pressures, body mass index (BMI), and triglyceride levels were identified as major clinical determinants of carotid properties with adjustment of age and sex. Conclusions::The age- and sex-specific reference values of carotid properties measured by RF ultrasound for healthy Chinese adults were established. The blood pressures, BMI, and triglyceride levels should be considered for clinical application of corresponding reference values.
5.Prediction Model for Unfavorable Outcome in Spontaneous Intracerebral Hemorrhage Based on Machine Learning
Shengli LI ; Jianan ZHANG ; Xiaoqun HOU ; Yongyi WANG ; Tong LI ; Zhiming XU ; Feng CHEN ; Yong ZHOU ; Weimin WANG ; Mingxing LIU
Journal of Korean Neurosurgical Society 2024;67(1):94-102
Objective:
: The spontaneous intracerebral hemorrhage (ICH) remains a significant cause of mortality and morbidity throughout the world. The purpose of this retrospective study is to develop multiple models for predicting ICH outcomes using machine learning (ML).
Methods:
: Between January 2014 and October 2021, we included ICH patients identified by computed tomography or magnetic resonance imaging and treated with surgery. At the 6-month check-up, outcomes were assessed using the modified Rankin Scale. In this study, four ML models, including Support Vector Machine (SVM), Decision Tree C5.0, Artificial Neural Network, Logistic Regression were used to build ICH prediction models. In order to evaluate the reliability and the ML models, we calculated the area under the receiver operating characteristic curve (AUC), specificity, sensitivity, accuracy, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR).
Results:
: We identified 71 patients who had favorable outcomes and 156 who had unfavorable outcomes. The results showed that the SVM model achieved the best comprehensive prediction efficiency. For the SVM model, the AUC, accuracy, specificity, sensitivity, PLR, NLR, and DOR were 0.91, 0.92, 0.92, 0.93, 11.63, 0.076, and 153.03, respectively. For the SVM model, we found the importance value of time to operating room (TOR) was higher significantly than other variables.
Conclusion
: The analysis of clinical reliability showed that the SVM model achieved the best comprehensive prediction efficiency and the importance value of TOR was higher significantly than other variables.
6.Contrast-Enhanced Ultrasound in the Differential Diagnosis of Gallbladder Polypoid Lesions:A Multicenter Study
Ligang JIA ; Xiang FEI ; Xiang JING ; Mingxing LI ; Fang NIE ; Dong JIANG ; Shaoshan TANG ; Wei ZHANG ; Hong DING ; Tao SONG ; Qi ZHOU ; Bei ZHANG ; Zhixia SUN ; Xiaojuan MA ; Nianan HE ; Fang LI ; Yingqiao ZHU ; Wen CHENG ; Yukun LUO
Chinese Journal of Medical Imaging 2024;32(11):1147-1154
Purpose To explore the value of contrast-enhanced ultrasound(CEUS)in the differential diagnosis of gallbladder polypoid lesions(GPLs)(diameter≥10 mm).Materials and Methods A prospective enrollment of 229 patients with GPLs who underwent cholecystectomy in 17 hospitals from December 1 2021 to June 30 2024 was conducted to analyze the relationship between general data,conventional ultrasound,CEUS characteristics and the nature of GPLs.Multivariate Logistic regression was employed to identify independent risk factors for neoplastic polyps,the differential diagnostic value of different indicators was compared.Results Among 229 patients with GPLs,there were 108 cases of cholesterol polyps,102 cases of adenoma and 19 cases of gallbladder cancer.Age(Z=-4.476,P<0.001),polyp number(χ2=15.561,P<0.001),diameter(Z=-8.149,P<0.001),echogenicity(χ2=9.241,P=0.010),vascularity(χ2=23.107,P<0.001),enhancement intensity(χ2=47.610,P<0.001),enhancement pattern(χ2=6.468,P=0.011),vascular type(χ2=84.470,P<0.001),integrity of gallbladder wall(χ2=7.662,P=0.006)and stalk width(Z=-9.831,P<0.001)between cholesterol polyps and neoplastic polyps were statistically significant.Age,location,diameter,echogenicity,enhancement pattern,vascular type and stalk width between adenoma and gallbladder cancer were statistically significant(Z=-4.333,-3.902,-5.042,all P<0.05).Multivariate Logistic regression analysis showed that hyper-enhancement,branched vascular type and stalk width were independent risk factors for neoplastic polyps(OR=4.563,5.770,3.075,all P<0.001).The combination of independent risk factors was better than single factor and diameter in the differential diagnosis of cholesterol polyps and neoplastic polyps(all P<0.01).Conclusion CEUS can effectively identify the nature of GPLs and provide a valuable imaging reference for the selection of treatment methods.
7.Human 8-cell embryos enable efficient induction of disease-preventive mutations without off-target effect by cytosine base editor.
Yinghui WEI ; Meiling ZHANG ; Jing HU ; Yingsi ZHOU ; Mingxing XUE ; Jianhang YIN ; Yuanhua LIU ; Hu FENG ; Ling ZHOU ; Zhifang LI ; Dongshuang WANG ; Zhiguo ZHANG ; Yin ZHOU ; Hongbin LIU ; Ning YAO ; Erwei ZUO ; Jiazhi HU ; Yanzhi DU ; Wen LI ; Chunlong XU ; Hui YANG
Protein & Cell 2023;14(6):416-432
Approximately 140 million people worldwide are homozygous carriers of APOE4 (ε4), a strong genetic risk factor for late onset familial and sporadic Alzheimer's disease (AD), 91% of whom will develop AD at earlier age than heterozygous carriers and noncarriers. Susceptibility to AD could be reduced by targeted editing of APOE4, but a technical basis for controlling the off-target effects of base editors is necessary to develop low-risk personalized gene therapies. Here, we first screened eight cytosine base editor variants at four injection stages (from 1- to 8-cell stage), and found that FNLS-YE1 variant in 8-cell embryos achieved the comparable base conversion rate (up to 100%) with the lowest bystander effects. In particular, 80% of AD-susceptible ε4 allele copies were converted to the AD-neutral ε3 allele in human ε4-carrying embryos. Stringent control measures combined with targeted deep sequencing, whole genome sequencing, and RNA sequencing showed no DNA or RNA off-target events in FNLS-YE1-treated human embryos or their derived stem cells. Furthermore, base editing with FNLS-YE1 showed no effects on embryo development to the blastocyst stage. Finally, we also demonstrated FNLS-YE1 could introduce known protective variants in human embryos to potentially reduce human susceptivity to systemic lupus erythematosus and familial hypercholesterolemia. Our study therefore suggests that base editing with FNLS-YE1 can efficiently and safely introduce known preventive variants in 8-cell human embryos, a potential approach for reducing human susceptibility to AD or other genetic diseases.
Humans
;
Apolipoprotein E4/genetics*
;
Cytosine
;
Mutation
;
Blastocyst
;
Heterozygote
;
Gene Editing
;
CRISPR-Cas Systems
8.An engineered xCas12i with high activity, high specificity, and broad PAM range.
Hainan ZHANG ; Xiangfeng KONG ; Mingxing XUE ; Jing HU ; Zikang WANG ; Yinghui WEI ; Haoqiang WANG ; Jingxing ZHOU ; Weihong ZHANG ; Mengqiu XU ; Xiaowen SHEN ; Fengcai YIN ; Zhiyuan AI ; Guangyan HUANG ; Junhui XIA ; Xueqiong SONG ; Hengbin LI ; Yuan YUAN ; Jinhui LI ; Na ZHONG ; Meiling ZHANG ; Yingsi ZHOU ; Hui YANG
Protein & Cell 2023;14(7):538-543
9.Application of Linear Accelerator on Boarding Kilovolt Fan Beam CT and Megavolt Cone Beam CT System on Set-up Errors During Radiation Treatment
Yong ZHOU ; Zeying JIANG ; Baofeng SU ; Jianfeng ZHOU ; Qian WANG ; Anting WANG ; Jingxian LIU ; Yan XUE ; Huiyi FENG ; Xiaoliang WU ; Mingxing XIAO ; Wenyong TAN
Cancer Research on Prevention and Treatment 2023;50(11):1097-1102
Objective To quantify the setup errors for the different anatomical sites of patients who received intensity-modulated radiotherapy (IMRT) with linear accelerator on-board kilovolt fan beam CT(kV-FBCT) as non-isocenter IGRT and megavolt cone beam CT (MV-CBCT) as isocenter IGRT. Methods A retrospective analysis was performedon 70 patients who underwent radiotherapy, kV-FBCT, and/or MV-CBCT scans after each routine setup prior to IMRT. The average displacement (M), systematic error (Σ), and random error (б) at different treatment sites in the left-right, anterior-posterior, and cranial-caudal directions were calculated according to the individual displacements. The formula 2.5Σ+0.7б was used to estimate the PTV margin in respective direction. For each single patient, the root mean square in three directions was used as 3D displacement. Results A total of 1130 displacements were recorded in the 70 patients. The PTV margin was estimated to be 1.9-3.1 mm in head and neck cancer, 2.8-5.1 mm in thoracic cancer, 4.6-5.1 mm in breast cancer, 3.0-5.5 mm in upper abdominal cancer, and 3.5-6.8 mm in pelvic tumor. For the 3D mean displacements, the head and neck, thoracic, breast, upper abdominal, and pelvic cancer were 2.4±1.0, 4.0±1.6, 4.1±2.0, 4.6±2.1, and 4.6±2.1 mm, respectively. The average 3D displacement obtained by kV-FBCT and MV-CBCT were 4.1 and 3.4 mm, respectively (
10.Short-term clinical and echocardiographic outcomes of the novel domestic transcatheter edge-to-edge repair Neonova? system in patients with mitral regurgitation
Yun YANG ; He LI ; Wenqian WU ; Xiaoke SHANG ; Shu CHEN ; Yucheng ZHONG ; Manwei LIU ; Lin HE ; Zhenxing SUN ; Ziming ZHANG ; Yi ZHOU ; Xin ZHANG ; Nianguo DONG ; Lingyun FANG ; Mingxing XIE
Chinese Journal of Ultrasonography 2023;32(1):51-59
Objective:To investigate short-term safety, efficacy and the learning curve of this self-developed novel transcatheter valve repair system (Neonova?) in patients with mitral regurgitation, and explore the role of perioperative echocardiography.Methods:Ten patients who visited the Union Hospital of Tongji Medical College, Huazhong University of Science and Technology from June 2021 to March 2022 and met the inclusive criteria were prospectively enrolled. All the patients were at high risk of surgery with moderate to severe or severe mitral regurgitation (MR). Clamps of Neonova? were implanted under guidance of transesophageal echocardiography and digital subtraction angiography. Clinical outcomes, echocardiography indexes and learning curves of this technique were evaluated immediately after intervention, 7 d, 1 month and 3 months post-intervention.Results:The technical success rate was 100% with MR relieved in all patients immediately after intervention. The device and procedural success rates were both 90.0% with 1 patient received surgical replacement at 37 days post-intervention while the others′ reduced to mild (8/9) and moderate (1/9) MR. New York Heart Association class and the Kansas City Cardiomyopathy Questionnaire improved significantly (all P<0.001). Mean mitral valve pressure gradient didn′t increase significantly after intervention when compared with that before intervention( P=0.324), and no mitral stenosis was observed. Left ventricular end-diastolic diameter decreased significantly ( P=0.008) during follow up.Procedure duration ranged from 60 to 300 (175.8±75.2)minutes. The simple linear regression model between procedure volume and duration showed that procedure duration decreased significantly with the increase of procedure volume ( F=15.857, P=0.004). Conclusions:Neonova? implantation can improve MR severity and clinical symptoms safely and effectively. Transthoracic echocardiography and transesophageal echocardiography are essential for perioperative management of transcatheter mitral valve repair.

Result Analysis
Print
Save