1.Study on surface microcirculation sensitization of acupuncture points related to cold coagulation and stasis syndrome in primary dysmenorrhea
Xuxin LI ; Xuesong WANG ; Miao LIN ; Mingjian ZHANG ; Yuanbo GAO ; Xifen ZHANG ; Hao CHEN ; Haiping LI ; Xiaojun ZHENG ; Xisheng FAN ; Jun LIU ; Juncha ZHANG ; Yanfen SHE
Journal of Beijing University of Traditional Chinese Medicine 2025;48(2):253-269
Objective:
To assess the dynamic changes of microcirculation at acupoints in patients with primary dysmenorrhea and cold congelation and blood stasis syndrome using laser speckle blood flow imaging.
Methods:
Patients with primary dysmenorrhea and cold coagulation and blood stasis syndrome (primary dysmenorrhea group, n=53) and healthy female college students(control group, n=57) who met the inclusion and exclusion criteria from October 2020 to July 2022 were enrolled at Hebei University of Chinese Medicine. On the premenstrual and first day of menstruation, a laser speckle blood flow imaging system was used to measure the microcirculation blood flow perfusion on the surface of acupoints related to the conception, thoroughfare, and governor vessels, and stomach, spleen, and bladder meridians in the abdomen and lumbosacral regions. The dynamic changes in microcirculation were calculated based on the difference in average blood flow perfusion at each acupoint before and after menstruation. Receiver operating curve (ROC) analysis was used to analyze the diagnostic efficacy of dynamic changes in microcirculation on the surface of each acupoint. The microcirculation sensitization rate of acupoints was calculated.
Results:
Compared with the control group, the dynamic changes in microcirculation at the following acupoints in the primary dysmenorrhea group were increased (P<0.05): conception vessel (Yinjiao[CV7], Qihai[CV6], Shimen[CV5], Guanyuan[CV4]); left thoroughfare vessel (left Huangshu[KI16], left Zhongzhu[KI15], left Siman[KI14], left Qixue[KI13], left Dahe[KI12], left Henggu[KI11]); left stomach meridian (left Tianshu[ST25], left Wailing[ST26], left Qichong[ST30]); left spleen meridian (left Daheng[SP15], left Fujie[SP14]); right thoroughfare vessel (right Huangshu[KI16], right Zhongzhu[KI15], right Siman[KI14], right Qixue[KI13], right Dahe[KI12], right Henggu[KI11]); right stomach meridian (right Wailing[ST26], right Daju[ST27], right Shuidao[ST28], right Guilai[ST29], right Qichong[ST30]); and right spleen meridian (right Fujie[SP14]). The area under the ROC curve of conception vessel (Yinjiao[CV7], Qihai[CV6], Shimen[CV5], Guanyuan[CV4]), thoroughfare vessel (right Siman[KI14], left Huangshu[KI16], right Qixue[KI13], right Zhongzhu[KI15], right Dahe[KI12], left Zhongzhu[KI15], left Siman[KI14], right Huangshu[KI16], left Qixue[KI13], right Henggu[KI11], left Henggu[KI11], left Dahe[KI12]); stomach meridian (left Tianshu[ST25], right Guilai[ST29], left Wailing[ST26], right Shuidao[ST28], right Daju[ST27], right Wailing[ST26], right Qichong[ST30], left Qichong[ST30]), and spleen meridian (left Daheng[SP15], left Fujie[SP14], right Fujie[SP14]) was 0.610-0.682 (P<0.05). Compared with the control group, the sensitization rate of some acupoints in the primary dysmenorrhea group increased (P<0.05).
Conclusion
With the onset of menstruation, the blood flow perfusion of some acupoints in the abdomen (thoroughfare, and conception vessels, and stomach and spleen meridians) of patients with primary dysmenorrhea and cold blood coagulation and blood stasis syndrome increased, and the status of acupoints changed from a resting state to an active state. These acupoints are sensitive in patients with primary dysmenorrhea and cold blood coagulation and blood stasis syndrome and have a certain diagnostic efficacy, providing a basis for further analyzing the efficacy and mechanism of acupuncture and moxibustion to treat primary dysmenorrhea with cold blood coagulation and blood stasis syndrome.
2.Establishment of a"#-shaped"method of radiotherapy marking of reflecting the range of respiratory motion in radiotherapy
Chenlei GUO ; Ying CAO ; Xin FENG ; Kaixuan ZHANG ; Zhen WANG ; Mingjian SUN ; Yongli SONG ; Xing LIU ; Wenyang LIU ; Jianrong DAI
China Medical Equipment 2025;22(8):52-56
Objective:To propose a novel radiotherapy marking method-the"#"-character method,which aimed at improving the accuracy and repeatability of positioning during radiotherapy.Methods:A specially"cross-shaped"stamp was designed by this study,which consisted of a handheld square base with a"cross-shaped"protrusion.Using this stamp,the extreme positions of end-expiration and end-inspiration were marked respectively at the laser-guided regions on the directly above and bilateral sides of the patient's body,and each position was printed a"+"character.Finally,a"#-shaped"signal was formed,which represented the full range of respiratory motion of patients.The study included two parts:surface displacement caused by respiration was simulated through a three-dimensional(3D)motion platform,which was used to conduct a phantom experiment for anthropomorphic dummy,A randomized controlled study involving 40 patients,who were treated between January and June 2024 at the Department of Radiotherapy,Cancer Hospital,Chinese Academy of Medical Sciences,were conducted.The cohort included 20 patients with breast tumor(Positioning the outer contour by exposing the chest)and 20 patients with thoracic tumor(fixed position of using thermoplastic film).These patients were divided into two groups for comparison,which received respectively the"#-shaped"method and the conventional"+-shaped"method.The cone-beam computed tomography(CBCT)images before treatment were used to compare the influences of the two kinds of marking methods on the positioning errors of patients with breast tumor and patients with thoracic tumor.Then,the statistical analysis was used to assess precision and accuracy of positioning.Results:The result of phantom experiment indicated that the positioning error of the"#-shaped"method was significantly better than that of the"+-shaped"method under various parameters of respiratory movement.Under three kinds of different respiratory cycles(3,4,and 5 seconds)and amplitudes(8,12,and 15 mm),the positioning errors of the"#-shaped"method were respectively(0.15±0.04)cm,(0.19±0.05)cm and(0.35±0.14)cm,while the"+-shaped"method were respectively(0.42±0.16)cm,(0.64±0.28)cm and(0.88±0.37)cm,and the differences were statistically significant(t=8.347,3.416,2.901,P<0.05).The results of actual patients indicated the positioning error[(0.97±0.32)cm]of the"#-shaped"method was significantly lower than[(1.62±0.47)cm]of the"+-shaped"method for patients with breast tumor(Positioning the outer contour by exposing the chest),and the difference was significant(t=3.615,P<0.05).On the other hand,the positioning error[(0.69±0.24)cm]of the"#-shaped"method was significantly lower than[(0.97±0.39)cm]of the"+-shaped"method for patients with thoracic tumor(fixed position of using thermoplastic film),and the difference also was significant(t=1.934,P<0.05).Conclusion:Compared to the conventional"+-shaped"method,the"#-shaped"method appears higher accuracy and repeatability during the positioning process of radiotherapy,which especially is suitable to the treatment for breast tumor and thoracic tumor that need accurately control the influences of respiratory motion.
3.Comparison of bladder volume measurement accuracy between two-dimensional ultrasound with three-dimensional reconstruction and conventional two-dimensional ultrasound
Kaixuan ZHANG ; Ying CAO ; Lijing ZUO ; Zhen WANG ; Wensheng NIE ; Yongli SONG ; Xing LIU ; Mingjian SUN ; Yuan TANG ; Yueping LIU
Chinese Journal of Radiation Oncology 2025;34(12):1238-1244
Objective:To compare the accuracy of two-dimensional (2D) ultrasound with three-dimensional (3D) reconstruction and conventional 2D ultrasound in measuring bladder volume in pelvic tumor patients, using computed tomography (CT) as the reference.Methods:A set of bladder phantoms were constructed to compare CT and ultrasound measurements with actual injected volumes. Clinical data of 104 pelvic tumor patients who received radiotherapy at the Cancer Hospital, Chinese Academy of Medical Sciences between August and December 2023 were retrospectively analyzed. Portable transabdominal ultrasound was used to obtain the largest bladder cross-section, and the maximum diameters in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions (D LR, D AP, D SI) were measured. The 2D ultrasound volume was calculated as V=0.523 × D LR × D AP × D SI. Full-bladder transverse videos were recorded and processed in Matlab R2016a through frame extraction(60 images), followed by contrast enhancement, edge detection segmentation, cubic spline interpolation, and image smoothing to achieve 3D reconstruction. Paired t-tests, intraclass correlation coefficients (ICC), and Bland-Altman analyses were performed to assess systematic bias and consistency between ultrasound methods and CT. Multivariate linear regression was applied to evaluate the effects of slice thickness, posture, age, and other factors on CT measurements. Results:In the phantom study, deviations of 2D ultrasound and CT from actual injected volumes were (0.73±3.05) ml ( t=-0.48, P=0.667) and (1.52±11.27) ml ( t=0.17, P=0.875), with ICC values>0.999. In the clinical study, mean bladder volumes measured by 3D-reconstructed ultrasound, conventional 2D ultrasound, and CT were (373.5±153.31), (314.89±135.28), (382.82±157.57) ml, respectively. The 3D-reconstructed method showed excellent agreement with CT (ICC=0.98; Bland-Altman mean bias=-9.32 ml, P=0.096), while 2D ultrasound also showed good consistency (ICC=0.91), but significantly underestimated bladder volume (mean bias=-67.93 ml, P<0.001). Subgroup analysis revealed that 2D ultrasound had the best agreement with CT in the medium-volume group (200-500 ml, ICC=0.902), whereas agreement decreased in the small-volume (<200 ml, ICC=0.884) and large-volume (>500 ml, ICC=0.840) groups (all P<0.001). The 3D-reconstructed ultrasound maintained excellent consistency with CT across all subgroups (all ICC>0.95), and the measured bladder volume was not statistically significant. Multivariate regression showed that slice thickness, posture, age, sex, and surgical status had no significant effects on CT measurements. Conclusions:Ultrasound with 3D reconstruction enables accurate bladder volume monitoring through true 3D contour reconstruction, while conventional 2D ultrasound systematically underestimates bladder volume and requires correction.
4.Establishment of a"#-shaped"method of radiotherapy marking of reflecting the range of respiratory motion in radiotherapy
Chenlei GUO ; Ying CAO ; Xin FENG ; Kaixuan ZHANG ; Zhen WANG ; Mingjian SUN ; Yongli SONG ; Xing LIU ; Wenyang LIU ; Jianrong DAI
China Medical Equipment 2025;22(8):52-56
Objective:To propose a novel radiotherapy marking method-the"#"-character method,which aimed at improving the accuracy and repeatability of positioning during radiotherapy.Methods:A specially"cross-shaped"stamp was designed by this study,which consisted of a handheld square base with a"cross-shaped"protrusion.Using this stamp,the extreme positions of end-expiration and end-inspiration were marked respectively at the laser-guided regions on the directly above and bilateral sides of the patient's body,and each position was printed a"+"character.Finally,a"#-shaped"signal was formed,which represented the full range of respiratory motion of patients.The study included two parts:surface displacement caused by respiration was simulated through a three-dimensional(3D)motion platform,which was used to conduct a phantom experiment for anthropomorphic dummy,A randomized controlled study involving 40 patients,who were treated between January and June 2024 at the Department of Radiotherapy,Cancer Hospital,Chinese Academy of Medical Sciences,were conducted.The cohort included 20 patients with breast tumor(Positioning the outer contour by exposing the chest)and 20 patients with thoracic tumor(fixed position of using thermoplastic film).These patients were divided into two groups for comparison,which received respectively the"#-shaped"method and the conventional"+-shaped"method.The cone-beam computed tomography(CBCT)images before treatment were used to compare the influences of the two kinds of marking methods on the positioning errors of patients with breast tumor and patients with thoracic tumor.Then,the statistical analysis was used to assess precision and accuracy of positioning.Results:The result of phantom experiment indicated that the positioning error of the"#-shaped"method was significantly better than that of the"+-shaped"method under various parameters of respiratory movement.Under three kinds of different respiratory cycles(3,4,and 5 seconds)and amplitudes(8,12,and 15 mm),the positioning errors of the"#-shaped"method were respectively(0.15±0.04)cm,(0.19±0.05)cm and(0.35±0.14)cm,while the"+-shaped"method were respectively(0.42±0.16)cm,(0.64±0.28)cm and(0.88±0.37)cm,and the differences were statistically significant(t=8.347,3.416,2.901,P<0.05).The results of actual patients indicated the positioning error[(0.97±0.32)cm]of the"#-shaped"method was significantly lower than[(1.62±0.47)cm]of the"+-shaped"method for patients with breast tumor(Positioning the outer contour by exposing the chest),and the difference was significant(t=3.615,P<0.05).On the other hand,the positioning error[(0.69±0.24)cm]of the"#-shaped"method was significantly lower than[(0.97±0.39)cm]of the"+-shaped"method for patients with thoracic tumor(fixed position of using thermoplastic film),and the difference also was significant(t=1.934,P<0.05).Conclusion:Compared to the conventional"+-shaped"method,the"#-shaped"method appears higher accuracy and repeatability during the positioning process of radiotherapy,which especially is suitable to the treatment for breast tumor and thoracic tumor that need accurately control the influences of respiratory motion.
5.Comparison of bladder volume measurement accuracy between two-dimensional ultrasound with three-dimensional reconstruction and conventional two-dimensional ultrasound
Kaixuan ZHANG ; Ying CAO ; Lijing ZUO ; Zhen WANG ; Wensheng NIE ; Yongli SONG ; Xing LIU ; Mingjian SUN ; Yuan TANG ; Yueping LIU
Chinese Journal of Radiation Oncology 2025;34(12):1238-1244
Objective:To compare the accuracy of two-dimensional (2D) ultrasound with three-dimensional (3D) reconstruction and conventional 2D ultrasound in measuring bladder volume in pelvic tumor patients, using computed tomography (CT) as the reference.Methods:A set of bladder phantoms were constructed to compare CT and ultrasound measurements with actual injected volumes. Clinical data of 104 pelvic tumor patients who received radiotherapy at the Cancer Hospital, Chinese Academy of Medical Sciences between August and December 2023 were retrospectively analyzed. Portable transabdominal ultrasound was used to obtain the largest bladder cross-section, and the maximum diameters in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions (D LR, D AP, D SI) were measured. The 2D ultrasound volume was calculated as V=0.523 × D LR × D AP × D SI. Full-bladder transverse videos were recorded and processed in Matlab R2016a through frame extraction(60 images), followed by contrast enhancement, edge detection segmentation, cubic spline interpolation, and image smoothing to achieve 3D reconstruction. Paired t-tests, intraclass correlation coefficients (ICC), and Bland-Altman analyses were performed to assess systematic bias and consistency between ultrasound methods and CT. Multivariate linear regression was applied to evaluate the effects of slice thickness, posture, age, and other factors on CT measurements. Results:In the phantom study, deviations of 2D ultrasound and CT from actual injected volumes were (0.73±3.05) ml ( t=-0.48, P=0.667) and (1.52±11.27) ml ( t=0.17, P=0.875), with ICC values>0.999. In the clinical study, mean bladder volumes measured by 3D-reconstructed ultrasound, conventional 2D ultrasound, and CT were (373.5±153.31), (314.89±135.28), (382.82±157.57) ml, respectively. The 3D-reconstructed method showed excellent agreement with CT (ICC=0.98; Bland-Altman mean bias=-9.32 ml, P=0.096), while 2D ultrasound also showed good consistency (ICC=0.91), but significantly underestimated bladder volume (mean bias=-67.93 ml, P<0.001). Subgroup analysis revealed that 2D ultrasound had the best agreement with CT in the medium-volume group (200-500 ml, ICC=0.902), whereas agreement decreased in the small-volume (<200 ml, ICC=0.884) and large-volume (>500 ml, ICC=0.840) groups (all P<0.001). The 3D-reconstructed ultrasound maintained excellent consistency with CT across all subgroups (all ICC>0.95), and the measured bladder volume was not statistically significant. Multivariate regression showed that slice thickness, posture, age, sex, and surgical status had no significant effects on CT measurements. Conclusions:Ultrasound with 3D reconstruction enables accurate bladder volume monitoring through true 3D contour reconstruction, while conventional 2D ultrasound systematically underestimates bladder volume and requires correction.
6.Comparison of the effects of remimazolam and dexmedetomidine on inhibiting cough during emergence from general anesthesia in patients undergoing thyroid surgery
Dan LI ; Shuai YI ; Xinlei ZHANG ; Fei TONG ; Mingjian KONG
Chinese Journal of Pharmacoepidemiology 2024;33(4):402-409
Objective To compare the inhibitory effects of remimazolam and dexmedetomidine on cough during emergence from general anesthesia after thyroid surgery.Methods Patients with 111 cases of thyroid surgery were randomly divided into 3 groups,37 in each group.Group A was given a bolus of 0.1 mg·kg-1 and 0.05 mg·kg-1·h-1 remimazolam intravenous infusion until extubation,group B was given 0.5 μg·kg-1 of the dexmedetomidine over 10 minutes,and group C was given same dose of normal saline.The incidence of cough during emergence from general anesthesia,the moderate and severe cough,the recovery time and extubation time,the Ramsay Sedation Scale(RSS)score,and the heart rate(HR),and mean arterial pressure(MAP)at different time points before and after intervention and before and after extubation were recorded and compared.Results There were significant differences in the incidence of coughing among group A,B and C(37.84%vs.67.57%vs.91.89%,adjusted P<0.016 7,respectively).The incidence of moderate and severe cough was also lower in group A than in group B and C(8.11%vs.35.14%vs.67.57%,adjusted P<0.001).The recovery time and extubation time were longer in group B than those of group A and C(adjusted P<0.001).The RSS scores at the time of extubation and after extubation were higher in group B than in group A and C(adjusted P=0.002 and P=0.007,respectively).After intervention,compared with group C,the HR of group A and B decreased to different degree,and different drugs interacted with time,and the HR of group B patients decreased to a greater extent.Conclusion Remimazolam suppresses the occurrence and reduces the severity coughing during emergence from general anesthesia,and reduce the severity in patients treated with thyroid surgeries.Compared with dexmedetomidine,remimazolam did not prolong recovery time and extubation time,remaining more stable haemodynamics.
7.Amelioration of dextran sulfate sodium-induced ulcerative colitis by fermented Lycium barbarum polysaccharides through modulation of intestinal microecology
Rong LI ; Ping YANG ; Mingjian LI ; Ziru YE ; Puyue ZHANG ; HUANG Yong
Journal of China Pharmaceutical University 2024;55(2):236-245
Abstract: To explore the mechanism of the intestinal microecology regulation by polysaccharide prebiotics, ELISA, histopathologic analysis, immunohistochemical analysis, 16S rRNA high-throughput sequencing, and gas chromatography-mass spectrometry were applied to investigate the effects of fermented polysaccharides on changes in the intestinal microbiota and short-chain fatty acids (SCFAs) in mice with dextran sulfate sodium (DSS)-induced colitis model and their relationship with the level of intestinal inflammation and barrier protein expression. It was found that fermented Lycium barbarum polysaccharides (FLBP) significantly reduced intestinal inflammation level, improved colonic tissue structure, up-regulated the expression of tight junction proteins Claudin-1 and ZO-1, and significantly increased the content of intestinal SCFAs in mice. Gut bacteria analyses showed that FLBP enriched intestinal Dubosiella and Akkermansia in mice and decreased the abundance of Turicibacter, Faecalibaculum, and Escherichia-Shigella. Results showed that remodeled Dubosiella activated by FLBP played a dominant role in ameliorating colitis by significantly increasing SCFAs content, improving intestinal barrier and reducing intestinal inflammation. The study aimed to provide a safer and better option for the amelioration of colitis and to provide a theoretical basis for the development of functional foods with FLBP.
8.Variation of right B2 downwards-shift: A special type of tracheal bronchus
Zhili LIU ; Min ZHANG ; Xingyuan LIU ; Mingjian GE
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(12):1759-1766
Objective To analyze and summarize the changes of the bronchus and vessels of right B2 downwards-shift. Methods The 5 280 patients who underwent three-dimensional computed tomography bronchography and angiography between January 2019 and January 2022 were screened. Based on the opening position of B1+3, we classified bronchial variations into a normal type, over type, and tracheal-bronchus type. Results Finally 6 patients were included with 1 male and 5 females, aged 29 to 71 years. According to our bronchial classification, there were 4 (66.7%) patients of the normal type in this group, 1 (16.7%) of over type, and 1 (16.7%) of tracheal-bronchus type. About arteries, 4 (66.7%) patients was the trunk superior (Tr.sup)+posterior artery (A.post) type and 2 (33.3%) Tr.sup+trunk inferior (Tr.inf)+A.post type. About veins, 2 (33.3%) patients were the Ⅰab+right upper lobe vein posterior to the bronchus intermedius (UVPBI) type, 1 (16.7%)Ⅰb+UVPBI type, 1 (16.7%) anterior+UVPBI type, 1 (16.7%) central+UVPBI type and 1 (16.7%) central type. Conclusion In the right B2 downwards-shift, A.post exists, and the posterior oblique fissure is poorly developed (RS2 and RS6 are interconnected). Therefore, it is easier for us to dissect and disconnect B2 intraoperatively, but it is necessary to be vigilant for vascular damage caused by opening the posterior oblique fissure.
9.Application of pulmonary circulation single-blocking method in intersegmental plane identification during segmentectomy
Weijie SUN ; Min ZHANG ; Xu CHEN ; Yuanlin DENG ; Mingjian GE
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2023;30(01):52-57
Objective To introduce a new method for identifying intersegmental planes during thoracoscopic segmentectomy using pulmonary circulation single-blocking in the target segment. Methods To retrospectively analyze the clinical data of 83 patients who underwent thoracoscopic pulmonary segmentectomy from January 2019 to March 2020 using the pulmonary circulation single-blocking method. There were 33 males and 50 females, with a median age of 54 (46-65) years, and they were divided into a single vein group (SVG, n=31) and a single artery group (SAG, n=52), and the clinical data of two groups were compared. Results The intersegmental planes were identified successfully in both groups and there were no statistically significant differences between the two groups in terms of intersegmental plane management (P=0.823), operating time (P=0.786), intraoperative blood loss (P=0.775), chest drainage time (P=0.659), postoperative hospital stay (P=0.824) or the incidence of postoperative complications (P=1.000). Conclusion The use of pulmonary circulation single-blocking for intersegmental plane identification during thoracoscopic segmentectomy is safe and feasible, and the intersegmental plane can be satisfactorily identified by the single-blocking of arteries or veins.
10.Management practice of the entire process of stem cells clinical research in medical institutions
Jigang ZHANG ; Mingjian ZHANG ; Yan ZHANG ; Shuyue ZHANG ; Huichen HE ; Yanhong ZHU ; Xueying DING ; Xingdong ZHENG
Chinese Journal of Medical Science Research Management 2023;36(3):189-193
Objective:The study aims to analyze the problems faced in the clinical research and management of stem cells, explore the construction of the entire process of stem cells clinical research, and promote the healthy and orderly development of the clinical research of stem cells.Methods:By consulting the literature and retrieval of relevant policies and regulations, this study analyzed the problems faced by the supervision and management department, medical institutions and researchers, this study and discussed the countermeasures for strengthening the management of the entire process of clinical research of stem cells in medical institutions.Results:There were imperfect internal system and poor management process, insufficient quality control of cell products, low quality of project management, and insufficient clinical research consciousness of stem cell clinical research management in medical institutions.Conclusions:Combined with the current management measures, guidance principles and medical institutions, we should improve the internal system of medical institutions, promote the centralized management and informatization construction of projects, strengthen cell quality control in the hospital, cultivate talent echelons and improve academic and ethical review capabilities, actively explore the management model that is suitable for the entire process of stem cell clinical research for medical institutions in China.