1.Assessing the relationship between pregabalin’s analgesic effect on neuropathic pain and patient’s quality of life and sleep quality
Oigonchimeg B ; Maralmaa T ; Sarnai S ; Enkhtsetseg E ; Narantungalag D
Mongolian Journal of Health Sciences 2026;92(2):78-81
Background:
Pregabalin significantly reduces pain intensity and improves sleep quality and health-related quality of life in patients with neuropathic pain. Since it remains uncertain whether the improvements in sleep quality and quality of life associated with Pregabalin are related to its analgesic properties. Therefore, this study aimed to evaluate whether these clinical outcomes are correlated.
Aim:
Assessing the Correlation Between patient’s analgesia and sleep quality, health-related quality of life outcomes after pregabalin treatment
Materials and Methods:
This study was conducted at the Geriatric Hospital of Bayangol District from February, 2026. Patients diagnosed seventy eight with neuropathic pain of any origin who attended the neurology outpatient clinic during the study period were enrolled. Pain intensity, sleep quality, and HRQoL outcomes were evaluated at baseline and at week 8 by means of an 11-point (0-10) numerical rating scale (NRS), the Pittsburgh Sleep Quality Index (PSQI), and the EuroQol EQ-5D-5L score, respectively. The study was designed as an uncontrolled observational analytic study, and statistical analyses were performed using SPSS version 27.0.
Result:
The mean age of the study participants was 59.5±15.7 years (n=78). Of the participants, 53.8% (n=42) were female and 46.2% (n=36) male. The relationships among pain intensity, sleep quality, and health related quality of life were evaluated using correlation analysis. A strong positive and statistically significant correlation was observed between sleep quality and quality of life (p<0.05), whereas no statistically significant associations were identified among the other variables.
Conclusion
It was observed that in patients with neuropathic pain, pregabalin reduced pain intensity and that a one-unit improvement in sleep quality was associated with a 0.7-unit increase in quality of life.
2.Comparative study of outdoor and indoor air pollution in Ulaanbaatar and Darkhan cities
Davaalkham D ; ; Ulziikhutag B ; Batzorig B ; ; Ser-Od Kh ; ; Nyamsuren B ; ; Yerkebulan M ; ; Enkhjargal G ; ; Shatar Sh ; ; Myagmarchuluun S ; ; Gantuya D ; ; Ulziimaa D ; ; Buyantushig B ; ; Jargalsaikhan G ; ; Anujin M ; Maralmaa E ; Khurelbaatar N ; ; Damdindorj B ;
Mongolian Journal of Health Sciences 2026;93(3):107-113
Background:
Ambient and household air pollution remain leading risk factors for global morbidity and mortality. Exposure to fine particulate matter (PM₂.₅) is associated with increased risks of cardiovascular and respiratory diseases, as well as lung cancer, metabolic and neurological disorders, and immune dysfunction. In urban areas of Mongolia, air pollution reaches critical levels during the winter season. Although improved solid fuels have been introduced in recent years, their impact on both outdoor and indoor air quality remains insufficiently characterized.
Aim:
To compare outdoor and household air pollution levels in Ulaanbaatar and Darkhan cities.
Materials and Methods:
Outdoor air pollution data for Ulaanbaatar were obtained from fixed monitoring stations of the National Agency for Meteorology and Environmental Monitoring for the period 2014–2026, with seasonal comparisons performed. For indoor air quality assessment, a longitudinal study was conducted among 240 households (apartments, houses, and traditional gers) in Ulaanbaatar and Darkhan from 2023 to 2026. PM₂.₅ concentrations were measured using real-time sensors (PurpleAir sensor), deployed for 14–21 days per season (winter and summer) in each household, recording data at 10-minute intervals over 24-hour periods.
Result:
Between 2014 and 2026, the 24-hour mean concentrations in Ulaanbaatar were 60.5 µg/m for PM₂.₅, 117.3 µg/m for PM₁₀, 37.3 µg/m for NO₂, 41.8 µg/m for SO₂, and 27.5 µg/m for O₃. While particulate matter levels showed a decreasing trend following the introduction of improved fuels, SO₂ concentrations increased, and overall pollution levels remained higher than those observed in Darkhan. Indoor PM₂.₅ concentrations were higher in Ulaanbaatar compared to Darkhan (60.7±86.1 vs 48.4±96.7 µg/m). Significant differences were observed by housing type (p<0.0001), with higher concentrations in households using solid fuels (houses and gers) and lower levels in apartments. These findings indicate substantial variability in indoor air pollution by city, housing type, and season, with persistently elevated exposure levels.
Conclusion
Outdoor air pollutant concentrations in Ulaanbaatar, including particulate matter, NO₂, and SO₂, exceed national standards and WHO guideline values by 1–4 times. Indoor PM₂.₅ pollution is higher in Ulaanbaatar than in Darkhan and varies significantly by housing type and season, indicating a high and heterogeneous exposure burden among urban populations.
3.Study on microcapsule preparation technology
Baatarbolat J ; Buyankhishig E ; Ichinkhorloo D ; Odonchimeg M ; Purevdolgor B ; Maralmaa Ts ; Shinezaya D ; Jambaninj D ; Davaadagva D ; Otgonsuren D
Mongolian Journal of Health Sciences 2026;93(3):203-210
Background:
Maintaining the concentration of a drug in the blood at a therapeutic level is crucial for enhancing treatment efficacy and reducing adverse effects. Conventional dosage forms are rapidly absorbed, causing a quick rise in the drug concentration in the blood, but it soon declines. As a result, frequent dosing is required in chronic or acute conditions. This can lead to drug concentrations exceeding therapeutic levels, increasing toxicity, or failing to reach the required level. To address these limitations, drug delivery systems (DDS) have been intensively developed over the past few decades. Among these systems, microencapsulation technology enables targeted delivery of the drug within the body, maintains stability, controls release, improves bioavailability, reduces side effects, and protects the active pharmaceutical ingredient from degradation or elimination, delivering it specifically to the necessary tissues. These characteristics provided the rationale for conducting this study.
Aim:
Select a suitable polymer for microcapsule formation, develop a production technology using the emulsion solvent evaporation method, and evaluate certain morphological characteristics of the resulting microcapsules.
Materials and Methods:
The microcapsules were prepared using an O/W emulsion solvent evaporation method. Dichloromethane (DCM) was used as the solvent, and the wall materials were solutions of chitosan (2% w/v) and gelatin (5% w/v), which are polymers combining biodegradability and biocompatibility. These solutions were mixed in a total of eight different ratios and emulsified into an aqueous phase containing polyvinyl alcohol (PVA, 1% w/v) using a high-speed homogenizer at 8000–10000 rpm to form the emulsion, followed by solvent evaporation. The resulting microcapsules were freeze-dried to obtain dry microcapsule forms. The morphology and surface structure of the microcapsules were characterized using light microscopy and scanning electron microscopy (SEM), while their size and distribution were analyzed using the ImageJ software.
Result:
To determine the optimal wall material for the microcapsules, a total of eight formulation ratios were prepared, and the emulsion stability and viscosity were evaluated. Chitosan-dominant formulations (F1, F7, F8) exhibited excessively high viscosity and a tendency for the system to thicken, which reduced the uniformity and stability of the emulsion. In contrast, formulations with low or imbalanced gelatin content (F2, F3) failed to achieve complete emulsion stabilization and showed significant phase separation. The F5 formulation demonstrated the best stability, minimal phase separation, and appropriate viscosity, making it the optimal choice for microcapsule wall preparation. The chitosan-to-gelatin ratio of 1:2 (F5 formulation) was found to be the most suitable in terms of complete microcapsule formation, spherical shape, uniform surface, and proper viscosity. Microcapsules of the F5 formulation had an average diameter of 290±30 µm, were spherical, and maintained shape stability even after freeze-drying. A microcapsule preparation technology based on the emulsion method was developed experimentally, and the most suitable conditions were established.
Conclusion
1. The results of the study indicated that a chitosan-to-gelatin ratio of 1:2 was the most suitable formulation for microcapsules in terms of complete formation, spherical shape, and uniform surface characteristics.
2. When the gelatin content increased, microcapsule morphology deteriorated and aggregation tendencies were observed, whereas higher chitosan content increased the viscosity of the solution, which affected the stability of the emulsion and resulted in non-uniform microcapsule sizes.
3. The 1:2 chitosan-gelatin ratio is therefore crucial for microcapsule preparation, and this wall composition can be applied in further studies involving drug-loaded microcapsules.
4.Indoor Particulate Matter Concentration in Households of Darkhan City
Nyamdorj J ; Bolor M ; Maralmaa E ; Yerkyebulan M ; Ser-Od Kh ; Myagmarchuluun S ; Shatar Sh ; Gantuya D ; Gregory C. Gray ; Junfeng Zhang ; Ulziimaa D ; Damdindorj B ; Khurelbaatar N ; Davaalkham D
Mongolian Journal of Health Sciences 2025;85(1):25-29
Background:
A 2018 study on the global burden of disease, accidents, and risk factors reported that 1.6 million peo
ple died in 2017 due to household air pollution. Poor indoor air quality has been highlighted as a contributing factor to
respiratory diseases, cardiovascular conditions, and exacerbation of asthma and allergies. A 2019 study estimated that
long-term exposure to fine particulate matter (PM2.5) with a diameter of 2.5 micrometers or less reduces average life
expectancy by 1.8 years, with more severe effects in highly polluted regions. Additionally, a study by Miller et al. (2007)
found that prolonged exposure to PM2.5 increases the risk of cardiovascular diseases, particularly among women. Direct
measurement devices are highly effective in determining indoor PM2.5 concentrations, identifying sources of pollution,
tracking pollutant dispersion, and monitoring temporal variations. Studies suggest that direct measurement is an accurate,
cost-effective method that provides detailed data suitable for local conditions.
Aim:
To investigate the indoor air quality of houses and apartments in Darkhan city during the winter season using the
Purple Air monitoring device.
Materials and Methods:
A cross-sectional study was conducted with a targeted sample of 128 households in Darkhan
city. The study examined factors such as stove type, type of coal used, annual and daily coal consumption, frequency of
heating, and chimney sealing conditions. To collect data, the Purple Air monitoring device was installed in each house
hold for a month, after which it was retrieved. During retrieval, participants completed a questionnaire. The questionnaire
consisted of 55 questions across 7 pages at the time of device installation and 25 questions across 3 pages at the time of
device retrieval. The collected data was analyzed using SPSS 25.0.
Results:
A total of 128 households in Darkhan city participated in the study. The average duration of residence in the
current home was 9.5 years, with no statistically significant variation. The distribution of housing types was as follows:
traditional Mongolian gers (40.6%), houses (39.1%), and apartments (20.3%). The 24-hour average PM2.5 concentration
was highest in gers (70.9 μg/m³), followed by houses (46.8 μg/m³) and apartments (22.8 μg/m³), with a statistically significant difference (p=0.0001). PM2.5 levels were most variable in gers, followed by houses and then apartments. House
holds using central heating (apartments) had an average 24-hour PM2.5 concentration of 22.8 μg/m³, whereas households
using stoves (gers and houses) had a significantly higher concentration of 59.4 μg/m³ (p=0.0001). However, there was
no statistically significant difference between traditional and improved stoves. Among study participants, 21.4% reported
that someone in their household smoked indoors. Additionally, 86.5% regularly burned incense, candles, or herbs, while
99.2% did not use an air purifier.
Conclusion
The indoor particulate matter concentration in houses and gers in Darkhan was 59.4μг/m3. Variations in
stove types, poor chimney sealing limited space, and frequent gaps and cracks contribute to increased spread of indoor
air pollutants.
5.Comparative Analysis of Outdoor Particulate Matter Concentrations in Ulaanbaatar Using Direct Measurements and Fixed Monitoring Station Data
Maralmaa E ; ; Yerkyebulan M ; Ser-Od Kh ; Shatar Sh ; Gantuya D ; Munkh-Erdene L ; Enkhjargal G ; Myagmarchuluun S ; Gregory Gray ; Junfeng Zhang ; Ulziimaa D ; Damdindorj B ; Davaalkham D ; ; Darambazar G
Mongolian Journal of Health Sciences 2025;89(5):105-111
Background:
Particulate matter with an aerodynamic diameter of 2.5 micrometers or smaller (PM2.5) penetrates
deep into the alveoli through the respiratory tract and is characterized by its ability to induce oxidative stress, systemic
inflammation, and vascular inflammation. Mongolia ranks among the countries with the highest levels of air pollution. In
Ulaanbaatar, where more than half of the country’s population resides, wintertime PM2.5 concentrations often exceed 200
μg/m³, which is about eight times higher than the World Health Organization (WHO) guideline value. A study involving
1,200 adults in Ulaanbaatar showed that quality of life deteriorated sharply during periods of high air pollution, with
effects more pronounced among individuals who already had impaired respiratory function.
Aim:
To examine the relationship between indoor household PM2.5 concentrations and lung function indicators among
adults in Ulaanbaatar and Darkhan.
Materials and Methods:
This analytical cross-sectional study recruited adult participants from Ulaanbaatar and Darkhan
through targeted sampling. Household air quality was measured using PurpleAir sensors, which were installed in
participants’ homes for one month. After exposure measurement, lung function was assessed via spirometry. Statistical
analyses were conducted using SPSS version 25.0.
Results:
A total of 236 participants were included: 114 (48.3%) from Ulaanbaatar and 122 (51.7%) from Darkhan. The
sample consisted of 111 men (47.0%) and 125 women (53.0%). The mean indoor PM2.5 concentration was 66.24 μg/m³
(SD 44.87 μg/m³), ranging from a minimum of 7.79 μg/m³ to a maximum of 264.55 μg/m³. Stratification by housing type
showed the highest PM2.5 levels in gers (82.34 μg/m³), followed by detached houses (67.34 μg/m³), while apartments
had the lowest concentrations (32.24 μg/m³). Correlation analysis revealed statistically significant negative associations
between PM2.5 levels and measures of expiratory function, including the FEV1/FVC ratio, peak expiratory flow (PEF),
and mid-expiratory flow (FEF25–75). Reduced forced vital capacity (FVC) was observed in 9.4% of participants, reduced
forced expiratory volume in one second (FEV1) in 15.3%, and a decreased FEV1/FVC ratio in 3.8%.
Conclusion
Indoor household PM2.5 concentrations were highest in gers, and expiratory flow-related lung function
parameters showed significant negative associations with particulate exposure. This suggests that indoor PM2.5 primarily
affects airflow limitation rather than overall lung volumes in this population.
6.Interactions between herbs and conventional drugs
Narantungalag D ; Maralmaa T ; Oigonchimeg B ; Ser-Od B ; Tsetsegsuren E ; Gerelmaa B ; Sarnai S
Diagnosis 2024;110(3):5-13
This article provides an overview of the clinical evidence of interactions between herbal and conventional medicines. Herbs involved in drug interactions – or that have been evaluated in pharmacokinetic trials – are discussed in this review. While many of the interactions reported are of limited clinical significance and many herbal products (echinacea, valerian) seem to expose patients to minor risk
under conventional pharmacotherapy, a few herbs, notably St. John’s wort, may provoke adverse events sufficiently serious about endangering the patient’s health.
Healthcare professionals should remain vigilant for potential interactions between herbal medicines and prescribed drugs, especially when drugs with a narrow therapeutic index are used. Hypericum perforatum L. (St. John’s wort) extracts are widely used as a safe alternative to conventional antidepressant drugs for mild to moderate forms of depressive disorders.
St. John’s wort represents the herbal product that is most involved in herb-to drug interactions.
The aim of this article is to provide an overview of the clinical data regarding the E2 interactions between herbal remedies and prescribed drugs.
For patients on prescription medications, the concomitant use of herbal medications can cause serious and adverse effects. It is the responsibility of health professionals to be well informed about the clinical evidence of herb-drug interactions.
7.Comparison of umbilical cord blood gas parameters of newborns with the use of some labory induction drugs
Oigonchimeg B ; Sarnai S ; Maralmaa T ; Ser-Od B ; Tsetsegsuren E ; Gerelmaa B ; Narantungalag D
Diagnosis 2024;110(3):40-46
Background:
Induction of labor is a procedure performed to prevent maternal and perinatal morbidity and mortality. The effects of birth control pills on babies are still controversial. Therefore, we conducted this study to compare the effects of oxytocin and misoprostol on fetal blood gas parameters.
Aim:
To compare the effects of misoprostol and oxytocin used in labor induction on umbilical cord blood parameters
Materials and methods:
We conducted this study among mothers who gave birth in the NICU, according to the inclusion criteria, a control group (n=30), misoprostol alone vaginally (n=30) and oxytocin drip alone (n= 30) and oxytocin with misoprostol group (n=30) 4 groups used 100 mothers were selected respectively. Umbilical artery blood was sampled and umbilical artery blood pH, pCO2, pO2, HCO3, and VE (blood base excess) parameters were measured in the laboratory. The umbilical cord blood acid-alkaline parameters and lactate levels were analyzed and evaluated using COBAS C311 and COBAS B221 instruments. It was compared and determined using SPSS26 and EXCEL programs.
Results:
The average age of all mothers included in the study was 27.87±6.12, the average gestation period was 39.6±0.7 weeks, and the average weight of the newborn was 3466±323 gr. The average umbilical cord blood pH value was 7.34±0.04 in the control group, 7.25±0.07 in the oxytocin group, 7.27±0.04 in the misoprostol group, and 7.24±0.04 in the oxytocin and misoprostol group. And lactate valie was 5.8 in the control group, 7.5 in the oxytocin group, 9.87 in the misoprostol group, 8.7 in the combined group.
Conclusions
Compared to the group that did not use labor-inducing drugs, the mean pH of umbilical cord blood and lactate level were higher or statistically significant in the 3 groups that used labor-inducing drugs, indicating that birth-inducing drugs affect the umbilical cord blood parameters.
Result Analysis
Print
Save
E-mail