1.Key scientific issues and breakthrough paths to eliminate the harm of hepatitis B virus infection
Yixue WANG ; Bo PENG ; Lei WEI ; Quanxin LONG ; Yuchen XIA ; Yinyan SUN ; Wenhui LI
Journal of Clinical Hepatology 2026;42(1):2-6
Hepatitis B virus (HBV) exclusively infects liver parenchymal cells and forms covalently closed circular DNA (cccDNA) within their nuclei. HBV cccDNA serves as the essential template for viral gene transcription, the sole source of progeny virus production, and the key driver of viral antigen expression, and it is the molecular basis for the persistence of HBV infection. Therefore, elimination and/or functional silencing of cccDNA is the key to eradicate chronic HBV infection. This article discusses the critical scientific issues that need to be solved during elimination of the harm of HBV infection from the perspectives of the synthesis, transcription, and clearance of cccDNA, as well as the impact of nonparenchymal cells on cccDNA, in order to provide a reference for eradicating HBV infection in the future.
2.Progress in mechanistic research on traditional Chinese medicine interventions for irritable bowel syndrome with diarrhea based on omics technologies
Shanxue GAO ; Jiale MA ; Long PENG ; Jie CHEN
China Pharmacy 2026;37(3):401-406
Irritable bowel syndrome with diarrhea (IBS-D), as a prototypical disorder involving the microbiota-gut-brain axis, remains poorly understood in terms of its pathogenesis, posing ongoing challenges for clinical diagnosis. Omics technologies, leveraging their high-throughput detection and systematic analysis advantages, has emerged as a critical tool for deciphering the complex mechanisms underlying traditional Chinese medicine (TCM) treatment of IBS-D. This systematic review summarizes the research progress of transcriptomics, proteomics, metabolomics, microbiomics, and multi-omics integration techniques in TCM interventions for IBS-D. In single-omics studies, transcriptomics using techniques like RNA-seq, reveals the regulatory mechanisms of TCM on IBS-related signaling pathways. Proteomics, leveraging quantitative technologies such as 2D-difference gel electrophoresis and tandem mass tag, identifies differentially expressed proteins and elucidates the action targets of TCM in treating IBS-D. Metabolomics, employing methods like UPLC-Q-TOF-MS and LC-MS/MS, discovers metabolic pathways regulated by TCM to improve metabolic disturbances in IBS-D. Microbiomics, based on 16S rRNA sequencing, confirms that TCM can reshape the gut microbiota structure and restore the intestinal microecological balance, thereby improving IBS-D. Multi-omics integration further overcomes the limitations of single-omics approaches by synthesizing information from transcriptomics, proteomics, metabolomics, and microbiomics, enabling a more comprehensive and systematic elucidation of the complex mechanisms underlying TCM treatment for IBS-D. In the future, research related to IBS-D should be advanced from three aspects: stratified clinical research based on TCM syndrome types, multi-omics integration verification mechanisms, and emerging omics to explore new mechanisms, providing more innovative ideas for the precise diagnosis and treatment of this disease.
3.Effect of Runmu Xiaoyao Powder on TLR4/MyD88/NF-κB Signaling Pathway in Mice with Dry Eye and Liver Depression-heat Syndrome
Xin PENG ; Xi LONG ; Yuan ZHONG ; Jun PENG ; Qinghua PENG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(13):112-122
ObjectiveThis paper aims to investigate the effect and mechanism of Runmu Xiaoyao powder on mice with dry eye and the syndrome of liver depression-heat syndrome based on the toll-like receptor 4 (TLR4)/myeloid differentiation primary response protein 88 (MyD88)/nuclear factor-κB (NF-κB) signaling pathway. MethodsSixty-six C57BL/6J female mice were randomly divided into a normal group, a model group, a sodium hyaluronate group, and high-, medium-, and low-dose Runmu Xiaoyao powder groups, with 11 mice per group. Except for those in the normal group, mice in the other groups were subjected to mouse models with dry eye and liver depression-heat syndrome by instilling a benzalkonium chloride solution and applying chronic pain stimulation in a dry environment. After modeling, mice in the high-, medium-, and low-dose Runmu Xiaoyao powder groups were administered intragastrically with 29.7, 14.85, 7.43 g·kg-1, respectively, twice a day for 14 consecutive days. The mice in the sodium hyaluronate group received 5 μL of sodium hyaluronate eye drops in each eye twice daily. The mice in the normal and model groups were administered intragastrically with an equal volume of deionized water. Measurements were taken of tear secretion in mice, irritability scores, corneal fluorescein staining, and histopathological changes in the cornea, lacrimal glands, meibomian glands, and liver tissue. Enzyme-linked immunosorbent assay (ELISA) was used to detect the levels of interleukin-1β (IL-1β) and tumour necrosis factor-α (TNF-α) in serum. Immunohistochemistry (IHC) was used to detect the protein expression of IL-1β and TNF-α in corneal and lacrimal gland tissues. Real-time quantitative polymerase chain reaction(Real-time PCR) and Western blot were employed to detect the mRNA and protein expressions of TLR4, MyD88, and NF-κB p65 in corneal, lacrimal gland, and meibomian gland tissues. ResultsCompared with those in the normal group, mice in the model group exhibited significantly reduced tear secretion, significantly higher irritability scores, and more pronounced corneal fluorescence staining, with marked pathological damage observed in the cornea, lacrimal glands, meibomian glands, and liver tissue. IL-1β and TNF-α levels in serum were significantly elevated. The protein expressions of IL-1β and TNF-α in corneal and lacrimal gland tissues, as well as the mRNA and protein expressions of TLR4, MyD88, and NF-κB p65 in corneal, lacrimal gland, and meibomian gland tissues, were all significantly increased (P<0.01). Compared with the model group, the sodium hyaluronate group and Runmu Xiaoyao powder groups with different doses exhibited increased tear secretion to varying degrees, alleviated corneal fluorescence staining and histopathological damage, reduced IL-1β and TNF-α levels in serum, and downregulated protein expressions of IL-1β and TNF-α in corneal and lacrimal gland tissues, as well as the mRNA and protein expressions of TLR4, MyD88, and NF-κB p65 in corneal, lacrimal gland, and meibomian gland tissues. The high-dose Runmu Xiaoyao powder group demonstrated a more pronounced effect, with multiple indicators showing superior results compared to those in the sodium hyaluronate group (P<0.05, P<0.01). ConclusionRunmu Xiaoyao powder down-regulates the TLR4/MyD88/NF-κB signaling pathway activity in the cornea, lacrimal glands, and meibomian glands of model mice with dry eye and liver depression-heat syndrome, thereby suppressing inflammatory responses and mitigating ocular surface tissue damage. The therapeutic effect is dose-dependent, and the high-dose group exerts the most prominent effect.
4.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
5.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
6.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
7.A real-world study on the application of modified midline catheter and central venous catheter in medical intensive care unit.
Guo LONG ; Zixi WANG ; Huan PENG ; Xiaoyuan CAO ; Yuxin LIU ; Li TAN
Chinese Critical Care Medicine 2025;37(10):956-961
OBJECTIVE:
To investigate the differences in indwelling duration, clinical scenarios, and complications between the modified midline catheter (MMC) and the central venous catheter (CVC) in the treatment of patients in the medical intensive care unit (ICU) and the risk factors for complications based on real-world data.
METHODS:
A retrospective cohort study was conducted. The adult patients admitted to the medical ICU of the Third Xiangya Hospital of Central South University and had undergone placement of either a MMC or a CVC between January 1, 2023, and July 31, 2024, were consecutively enrolled by querying the hospital's electronic medical record system. Based on the type of catheter inserted, the patients were divided into the MMC group and the CVC group. The two groups were compared regarding the selection of catheters in the context of different underlying diseases, the actual clinical application after catheterization, catheter-related complications, the international normalized ratio (INR) and platelet count (PLT) during puncture and catheterization, the length of ICU stay, total length of hospital stay, catheter indwelling duration, and mortality during hospitalization. Multivariate Logistic regression analysis was employed to identify independent risk factors for catheter removal.
RESULTS:
Among the 274 patients, 52 received a MMC and 222 received a CVC. The utilization rate of MMC was significantly higher than that of CVC in patients with acute respiratory distress syndrome (ARDS), cardiovascular disease, and cancer [ARDS: 92.3% (48/52) vs. 70.3% (156/222), cardiovascular disease: 84.6% (44/52) vs. 54.5% (121/222), cancer: 30.8% (16/52) vs. 17.1% (38/222), all P < 0.05]. However, the use of MMC was significantly lower than CVC when vasoactive drug infusion was required [57.7% (30/52) vs. 79.7% (177/222), P < 0.05]. A significantly higher proportion of patients in the MMC group had a catheter indwelling time ≥ 12 days as compared with the CVC group [32.7% (17/52) vs. 13.5% (30/222), P < 0.05]. There were no statistically significant differences in other underlying diseases, venous access usage, INR and PLT during puncture and catheterization, length of ICU stay, total length of hospital stay, and in-hospital mortality of patients between the two groups. Regarding catheter-related complications, although the incidence of partial or complete catheter removal in the MMC group was significantly higher than that in the CVC group [36.5% (19/52) vs. 5.4% (12/222), P < 0.05], the incidence of puncture site fluid leakage, puncture site skin allergy, and deep vein thrombosis were significantly lower than those in the CVC group [puncture site fluid leakage: 1.9% (1/52) vs. 22.1% (49/222), puncture site skin allergy: 0% (0/52) vs. 20.7% (46/222), deep vein thrombosis: 3.8% (2/52) vs. 16.7% (37/222), all P < 0.05]. Furthermore, the proportion of patients experiencing three or more types of complications in the MMC group was significantly lower than that in the CVC group [5.8% (3/52) vs. 17.6% (39/222), P < 0.05]. Multivariate Logistic regression analysis of risk factors for catheter removal identified the use of a MMC [odds ratio (OR) = 8.518, 95% confidence interval (95%CI) was 3.710-19.560, P < 0.001] and a catheter indwelling time ≥ 12 days (OR = 3.133, 95%CI was 1.297-7.567, P = 0.011) as independent risk factors.
CONCLUSIONS
MMC was more frequently used in patients with ARDS, cardiovascular disease, and cancer, whereas CVC was primarily employed for vasoactive drug infusion. The use of MMC and a longer indwelling time were identified as independent risk factors for catheter removal. Despite a higher removal rate, the overall incidence of complications was significantly lower with MMC than with CVC. These findings suggest that MMC could serve as a routine alternative to CVC in most of clinical scenarios, provided that measures are implemented to prevent removal.
Humans
;
Retrospective Studies
;
Intensive Care Units
;
Catheterization, Central Venous/methods*
;
Central Venous Catheters
;
Risk Factors
;
Length of Stay
;
Male
;
Female
;
Middle Aged
;
Adult
;
Catheters, Indwelling
;
Aged
8.Efficacy of volar locking plates combined with dorsal mini-plates for treatment of complex distal radius fractures
Jing PENG ; Ji WANG ; Shiyang CHEN ; Xiaotao LONG ; Jun FAN ; Ge WAN
Journal of Chongqing Medical University 2025;50(8):1103-1108
Objective:To investigate the efficacy of volar anatomical locking plates combined with dorsal mini-plates in treating com-plex distal radius fractures.Methods:We retrospectively included patients with complex distal radius fractures who had been treated with volar locking plates and dorsal mini-plates at Chongqing General Hospital from January 2019 to June 2023.The quality of articu-lar surface fragment reduction was assessed through image analysis.Follow-up data included the Mayo wrist score,Disabilities of the Arm,Shoulder,and Hand Questionnaire(DASH)score,wrist range of motion,time to fracture healing,and complications.Results:Twenty-eight patients[19 males,9 females;mean age,(45.4±11.9)years]were included,with a mean follow-up of 1(4.9±3.6)months.Their injury mechanisms included falls from height(11 cases),traffic accidents(9 cases),and simple falls(8 cases).After op-eration,the volar tilt was(5.1±4.9)°,and the ulnar inclination was(19.8±2.8)°;at the final follow-up,the angles were(5.2±4.8)° and(19.3±2.5)°,respectively,neither showing any significant change(P>0.05).At the final follow-up,all fractures healed,with a mean healing time of 3.6 months.At 1 year after operation,the wrist extension was(50.7±6.3)°;the wrist flexion was(49.4±6.1)°;the DASH score was 15.0±6.3;the Mayo wrist scores were excellent or good in 24 cases;the grip strength of the affected side averaged 84.4%of that of the contralateral side.No implant loosening occurred.Two cases of superficial wound infection and one case of exten-sor tendon irritation were reported.Conclusion:Locked volar plat-ing combined with dorsal mini-plating provides stable fixation for comminuted articular surface fragments in complex distal radius fractures,enabling early functional rehabilitation with favorable wrist recovery and low rates of dorsal tendon irritation.
9.Assessment of perioperative pulmonary fluid volume using remote dielectric sensing (ReDSTM) non-invasive lung fluid measurement technology in transcatheter tricuspid valve-in-valve implantation: The first case report
Yuliang LONG ; Yuan ZHANG ; Xiaochun ZHANG ; Peng WANG ; Xiaotong CUI ; Wenzhi PAN ; Daxin ZHOU ; Junbo GE
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(04):571-574
One of its primary surgical treatments of tricuspid regurgitation is tricuspid valve biological valve replacement. Catheter tricuspid valve-in-valve implantation is a novel interventional alternative for biological valve failure. The non-invasive lung fluid measuring device remote dielectric sensing (ReDSTM) has been increasingly incorporated into clinical practice as a means of monitoring chronic heart failure in recent years. This report describes the process and outcomes of the first instance of perioperative lung fluid volume evaluation following transcatheter tricuspid valve implantation utilizing ReDSTM technology. The patient has a short-term, substantial increase in postoperative lung fluid volume as compared to baseline.
10.Observation on therapeutic effect of self-made auxiliary reduction device combined with sinus tarsi approach in treatment of Sanders type Ⅱ to Ⅳ calcaneal fractures
Yu ZHOU ; Da-gang TANG ; Wei PENG ; Xiao-bo HU ; Zhi CHEN ; Peng LONG ; Zhi-ping KUANG ; Chuan-zhi ZHANG
Journal of Regional Anatomy and Operative Surgery 2025;34(7):604-609
Objective To observe the efficacy of self-made auxiliary reduction device combined with sinus tarsi approach(STA)in the treatment of Sanders type Ⅱ to Ⅳ calcaneal fractures.Methods A total of 40 patients with Sanders type Ⅱ to Ⅳ calcaneal fractures admitted to our hospital from January to June 2023 were selected and divided into the control group and the observation group by the random number table method,with 20 cases in each group.Patients in the control group underwent surgical treatment with the heel extensile lateral approach(ELA),while patients in the observation group underwent surgical treatment with the auxiliary reduction device combined with STA.The surgical-related indicators,postoperative complications and ankle-foot anatomical indicators of patients in the two groups were compared.The recovery of limb function was evaluated by the American Orthopaedic Foot and Ankle Society(AOFAS)ankle-hindfoot scale and Maryland foot function score.Results There was no statistically significant difference in the operation time,postoperative incision drying time,or duration of postoperative pain between the two groups(P>0.05).The postoperative suture removal time of the patients in the observation group was shorter than that of the control group,and the difference was statistically significant(P<0.05).The incidence of skin edge necrosis of incision and the total incidence of complications of patients in the observation group were significantly lower than those in the control group(P<0.05).The B?hler angle and Gissane angle of patients in both groups increased after surgery compared with those before surgery(P<0.05);there was no statistically significant difference in the B?hler angle or Gissane angle after surgery of patients between the two groups(P>0.05).The AOFAS score1 week after surgery of the patients in the observation group was higher than that in the control group(P<0.05),while there were no statistically significant differences in the AOFAS scores or Maryland scores of patients at other time points between the two groups(P>0.05).Conclusion The use of the auxiliary reduction device in surgical treatment with STA for Sanders type Ⅱ to Ⅳ calcaneal fractures can effectively restore the function of the foot and ankle,with short postoperative suture removal time and low incidence of postoperative complications.

Result Analysis
Print
Save
E-mail