1.Effect of decentration and tilt on in vitro optical quality of intraocular lenses with different focus designs
Ruolin PAN ; Xuan LIAO ; Changjun LAN ; Lixuan XIE ; Qingqing TAN ; Suyun QIN ; Huan HUANG ; Yan WANG
Chinese Journal of Experimental Ophthalmology 2025;43(3):211-218
Objective:To observe the effect of different degrees of decentration and tilt on the optical quality of the intraocular lenses (IOLs) with different focus designs.Methods:The UV 3300 PC UV-visible spectrophotometer was employed to measure the spectral transmittance of the monofocal IOL CT ASPHINA 509M (509M), bifocal IOL AT LISA 809M (809M), and trifocal IOL AT LISA Tri 839MP (839MP) within Zeiss MICS platform with a refractive power of + 20 D. The modulation transfer function (MTF) values at a spatial frequency of 50 lp/mm along with MTF curves and United States Air Force (USAF) resolution test charts for each IOL at the focal point were measured at apertures of 3.0 mm and 4.5 mm using the in vitro optical quality testing system OptiSpheric IOL R&D under centered, decentered (0.3, 0.5, 0.7, 0.9 and 1.1 mm) and tilted (3°, 5°, 7°, 9° and 11°) conditions. Results:All three IOLs filtrated the ultraviolet (UV) spectrum below 400 nm.When each IOL was in the centered position, at the 3.0 mm aperture, the MTF values were 0.772 at the far focus of the monofocal IOL 509M, 0.467 and 0.282 at the far and near focus of the bifocal IOL 809M, and 0.416, 0.147, and 0.229 at the far, intermediate, and near focus of the trifocal IOL 839MP, respectively.Whereas at the 4.5 mm aperture, the monofocal IOL 509M MTF value at the far focus was 0.664, the bifocal IOL 809M MTF values at the far and near focus were 0.506 and 0.264, and the trifocal IOL 839MP MTF values at the far, intermediate, and near focus were 0.392, 0.107, and 0.210, respectively.Among the three centered IOLs, the 509M demonstrated the highest MTF value at the far focus, followed by the 809M and then the 839MP; at the near focus, the MTF value of the 809M surpassed that of the 839MP.For decentration and tilt, the difference in MTF values of the three IOLs at the far and near focus was consistent with the differences observed when they were centered.At the same degree of decentration and tilt, all three IOLs exhibited superior optical quality at the 3.0 mm aperture compared to the 4.5 mm aperture.The optical quality of all three IOLs exhibited an overall decline as decentration and tilt increased.All three IOLs demonstrated a decrease in optical quality at the decentration of 0.3 mm or the tilt of 5°.Conclusions:The IOLs within the Zeiss MICS platform design exhibits identical spectral transmittance and UV filtering properties.Among the three IOLs, when centered, the 509M, the 839MP, and the 809M exhibit superior optical quality at the far, intermediate, and near focal points, respectively.Under decentered and tilted conditions, the 509M and the 809M demonstrate better resistance against decentration and tilt, respectively, at both far and near focuses.Additionally, all three IOLs demonstrate better optical quality at smaller apertures, given equivalent degrees of decentration or tilt.However, the optical quality at each focal point of the three IOLs decreases compared to the centered position when subjected to a decentration of 0.3 mm or a tilt of 5°.
2.Effect of decentration and tilt on in vitro optical quality of intraocular lenses with different focus designs
Ruolin PAN ; Xuan LIAO ; Changjun LAN ; Lixuan XIE ; Qingqing TAN ; Suyun QIN ; Huan HUANG ; Yan WANG
Chinese Journal of Experimental Ophthalmology 2025;43(3):211-218
Objective:To observe the effect of different degrees of decentration and tilt on the optical quality of the intraocular lenses (IOLs) with different focus designs.Methods:The UV 3300 PC UV-visible spectrophotometer was employed to measure the spectral transmittance of the monofocal IOL CT ASPHINA 509M (509M), bifocal IOL AT LISA 809M (809M), and trifocal IOL AT LISA Tri 839MP (839MP) within Zeiss MICS platform with a refractive power of + 20 D. The modulation transfer function (MTF) values at a spatial frequency of 50 lp/mm along with MTF curves and United States Air Force (USAF) resolution test charts for each IOL at the focal point were measured at apertures of 3.0 mm and 4.5 mm using the in vitro optical quality testing system OptiSpheric IOL R&D under centered, decentered (0.3, 0.5, 0.7, 0.9 and 1.1 mm) and tilted (3°, 5°, 7°, 9° and 11°) conditions. Results:All three IOLs filtrated the ultraviolet (UV) spectrum below 400 nm.When each IOL was in the centered position, at the 3.0 mm aperture, the MTF values were 0.772 at the far focus of the monofocal IOL 509M, 0.467 and 0.282 at the far and near focus of the bifocal IOL 809M, and 0.416, 0.147, and 0.229 at the far, intermediate, and near focus of the trifocal IOL 839MP, respectively.Whereas at the 4.5 mm aperture, the monofocal IOL 509M MTF value at the far focus was 0.664, the bifocal IOL 809M MTF values at the far and near focus were 0.506 and 0.264, and the trifocal IOL 839MP MTF values at the far, intermediate, and near focus were 0.392, 0.107, and 0.210, respectively.Among the three centered IOLs, the 509M demonstrated the highest MTF value at the far focus, followed by the 809M and then the 839MP; at the near focus, the MTF value of the 809M surpassed that of the 839MP.For decentration and tilt, the difference in MTF values of the three IOLs at the far and near focus was consistent with the differences observed when they were centered.At the same degree of decentration and tilt, all three IOLs exhibited superior optical quality at the 3.0 mm aperture compared to the 4.5 mm aperture.The optical quality of all three IOLs exhibited an overall decline as decentration and tilt increased.All three IOLs demonstrated a decrease in optical quality at the decentration of 0.3 mm or the tilt of 5°.Conclusions:The IOLs within the Zeiss MICS platform design exhibits identical spectral transmittance and UV filtering properties.Among the three IOLs, when centered, the 509M, the 839MP, and the 809M exhibit superior optical quality at the far, intermediate, and near focal points, respectively.Under decentered and tilted conditions, the 509M and the 809M demonstrate better resistance against decentration and tilt, respectively, at both far and near focuses.Additionally, all three IOLs demonstrate better optical quality at smaller apertures, given equivalent degrees of decentration or tilt.However, the optical quality at each focal point of the three IOLs decreases compared to the centered position when subjected to a decentration of 0.3 mm or a tilt of 5°.
3.Clinical analysis of microsurgery treatment of 87 cavernous sinus tumors
Kejun HE ; Nu ZHANG ; Lixuan YANG ; Chengjiang WEI ; Xixi LI ; Zhengsong HUANG
Chinese Journal of Microsurgery 2021;44(1):43-48
Objective:To investigate the efficacy of microsurgical treatment in cavernous sinus tumors.Methods:The clinical data of 87 patients with cavernous sinus tumor treated by microsurgery from January, 2010 to August, 2019 were analysed retrospectively. The surgical approaches and microsurgical skills for common tumors in Cavernous Sinus region were discussed. The follow-up included outpatient and telephone follow-ups, and the follow-up results were evaluated by KPS score.Results:Among the 87 cases, 57 were totally resected (65.5%), 14 were subtotal resected (16.1%) and 16 were major resected (18.4%). Hospitalisation ranged from 14 to 98 days, with an average of 29 days. Postoperative complications occurred in 30 cases with cranial nerve injury, 2 brain stem injury, 4 postoperative bleeding, 5 cerebrospinal fluid leakage, 4 infection, 1 Pituitary damage and 1 death. Prognosis and follow-up analysis showed 68 cases with KPS>60 and 66 with KPS>80 at 1 month after surgery; 74 with KPS>70 and 72 with KPS>80 at 3 months after surgery; 78 with KPS>80 by 12 months after surgery. During the follow-up period of 6-120 months, 3 cases died. Recurrence: 6 of incomplete resection of meningioma, were in 1-6 years after the surgery, 4 of incomplete resection of schwannoma in 1-8 years, 2 of pituitary adenoma respectively in 13 and 16 months after the surgery. There was no recurrence after reoperation. Two cases of chondrosarcoma, 3 of chordoma and 3 of germinoma were treated with radiotherapy, and during the follow-up, there was no progress of the focus. No tumor progression or recurrence was found in other cases during follow-up.Conclusion:Surgery of cavernous sinus tumor is difficult due to frequent postoperative complications. Reasonable preoperative plan, surgical approach and precise microsurgical techniques are the keys in reduction of postoperative complications and in the improvement of prognosis.
4.Contraceptive situation and influencing factors of women in childbearing age with chronic kidney disease
Pei DUAN ; Qinger WANG ; Lixuan HUANG ; Hui LI ; Guilan LU
Chinese Journal of Reproduction and Contraception 2020;40(4):320-324
Objective:To investigate the contraceptive status and influencing factors of women at reproductive age of chronic kidney disease (CKD), so as to provide evidence for improving reproductive health of women with CKD.Methods:A total of 256 female patients of reproductive age of CKD from November 2017 to February 2019 at National Clinical Research Center of Kidney Diseases, Jinling Hospital were selected to investigate the contraceptive status. And the investigation results were analyzed.Results:A total of 256 patients were investigated, and 246 valid question-naires were collected. Eighty-nine (36.18%) patients did not use contraceptive methods, 131 (53.25%) patients used one contraceptive method, and 26 (10.57%) patients used two or more contraceptive methods. The proportion of contraceptive users in order were condoms 51.59%, intrauterine devices 45.86%, oral drugs 7.01%, safe period 7.01%, external ejaculation 5.10%, and contraceptive injection 0.64%. Univariate analysis showed that age, marital status, one-child status, birth status, partner's attitude towards contraception, whether to accept contraceptive guidance, whether to have edema, and the number of children they intended to have were all related to the use of contraceptive measures, with statistically significant differences ( P<0.05). Multivariate regression analysis showed that those who were married, had 2 or more children, received contraceptive guidance, and had a positive attitude towards contraception were more likely to take contraceptive measures ( P<0.05). Conclusion:Child-bearing age women with CKD have a lower rate of contracep-tive use, especially long-duration contraception, and a higher risk of unintended pregnancy. Nurses should strengthen the propaganda and education of contraceptive knowledge of CKD patients, and take targeted intervention measures to improve the utilization rate of contraceptive tools.
5.Contraceptive situation and influencing factors of women in childbearing age with chronic kidney disease
Pei DUAN ; Qinger WANG ; Lixuan HUANG ; Hui LI ; Guilan LU
Chinese Journal of Reproduction and Contraception 2020;40(4):320-324
Objective:To investigate the contraceptive status and influencing factors of women at reproductive age of chronic kidney disease (CKD), so as to provide evidence for improving reproductive health of women with CKD.Methods:A total of 256 female patients of reproductive age of CKD from November 2017 to February 2019 at National Clinical Research Center of Kidney Diseases, Jinling Hospital were selected to investigate the contraceptive status. And the investigation results were analyzed.Results:A total of 256 patients were investigated, and 246 valid question-naires were collected. Eighty-nine (36.18%) patients did not use contraceptive methods, 131 (53.25%) patients used one contraceptive method, and 26 (10.57%) patients used two or more contraceptive methods. The proportion of contraceptive users in order were condoms 51.59%, intrauterine devices 45.86%, oral drugs 7.01%, safe period 7.01%, external ejaculation 5.10%, and contraceptive injection 0.64%. Univariate analysis showed that age, marital status, one-child status, birth status, partner's attitude towards contraception, whether to accept contraceptive guidance, whether to have edema, and the number of children they intended to have were all related to the use of contraceptive measures, with statistically significant differences ( P<0.05). Multivariate regression analysis showed that those who were married, had 2 or more children, received contraceptive guidance, and had a positive attitude towards contraception were more likely to take contraceptive measures ( P<0.05). Conclusion:Child-bearing age women with CKD have a lower rate of contracep-tive use, especially long-duration contraception, and a higher risk of unintended pregnancy. Nurses should strengthen the propaganda and education of contraceptive knowledge of CKD patients, and take targeted intervention measures to improve the utilization rate of contraceptive tools.
6.Monitoring of cerebrospinal fluid dynamics in a model of brain herniation induced by acute intracranial hypertension by PC cine MRI
Jianguo ZHOU ; Xiaoling ZHU ; Wupeng WEI ; Lixuan HUANG ; Yongbiao FENG ; Ling ZHANG ; Xiangfei MA ; Weixiong LI ; Jianfeng ZHANG ; Hesheng OU ; Huamin TANG
Chinese Journal of Emergency Medicine 2019;28(5):584-590
Objective To explore the monitoring of cerebrospinal fluid (CSF) dynamics in a model of brain herniation induced by acute intracranial hypertension in Guangxi Bama-Mini pigs by phasecontrast cine magnetic resonance imaging (PC cine MRI).Methods Femoral artery blood were extracted from 10 pigs,and injected into the frontal and temporal parietal lobe to make a model of brain herniation induced by acute intracranial hypertension.The mean arterial blood pressure (MAP),intracranial pressure (ICP),and cerebral perfusion pressure (CPP) were monitored.Routine T1WI,T2WI,coronal,sagittal and cerebrospinal fluid flow sequence (fast PC cine slice) which positioned on the cervical 3 (C3) vertebral body as the center and perpendicular to the spinal scans were performed on all experimental animals before and after blood injection with 3.0T Magnetic Resonance Imaging.The ICP,MAP,CPP,the absolute values of CSF peak flow velocity and the absolute value of carotid peak flow velocity before and after blood injection were compared.Results The ICP,MAP,CPP,and the absolute value of CSF peak flow velocity before injection of autologous arterial blood were statistically significant as compared with those after blood injection [(6.80±2.044) mmHg vs (52.20±1.619) mmHg,(76.80±7.068) mmHg vs (142.80±12.399) mmHg,(70.00±6.074) mmHg vs (90.50±12.250) mmHg,and the absolute value of CSF peak flow velocity was (243.20±77.671) mm/s vs (201.40±55.482) mm/s,respectively,P<0.01].The absolute value of the peak velocity of the carotid artery before blood injection was not statistically significant compared with that after blood injection [(876.80±239.908) mm/s vs (799.40±241.829) mm/s,P>0.05].Conclusion After the formation of brain herniation induced by acute intracranial hypertension,the CSF flow in the C3 level spinal canal showed a low dynamic change,and the CSF flow velocity waveform was disordered and malformed.The non-invasive measurement of CSF dynamics by PC cine MRI can provide an important basis for the change of CSF dynamics in the model of brain herniation induced by acute intracranial hypertension,and provide a theoretical basis for further research on damage control neurosurgery in the future.
7.Analysis of relationship between single umbilical artery diagnosed by prenatal ultrasonography and fetal malformation
Bingtian DONG ; Shu HUANG ; Jianping YAN ; Qihong LI ; Lixuan CHEN ; Ming YANG
Chinese Journal of Ultrasonography 2019;28(8):671-674
To evaluate the value of prenatal ultrasound in the diagnosis of single umbilical artery( SUA ) and fetal malformation . Methods T he characteristics of the prenatal ultrasound findings of 143 fetuses with SU A in different gestational weeks were retrospectively analyzed ,and the missing side of SU A were checked . Different types of SUA combined with fetal malformation were analyzed as well as chromosomal abnormalities and so on . Results For 143 fetuses with SU A ,there were 83 cases ( 58 .0% ) with absent left umbilical artery and 60 cases ( 42 .0% ) with absent right umbilical artery ,there was no statistical difference between the two groups ( P >0 .05 ) . Six cases ( 4 .2% ,6/143 ) were detected at and before 20 weeks of gestation ,and the rest 137 cases were detected after 20 weeks( 95 .8% ,137/143) . T here were 121 cases ( 84 .6% ) of isolated SUA ,22 cases ( 15 .4% ) were complicated with other malformations , including 10 cases ( 45 .5% ) with absent left umbilical artery and 12 cases ( 54 .5% ) with absent right umbilical artery . T here was no statistical difference between left and right umbilical artery deletion combined with fetal malformation( χ2 =1 .692 ,ν=1 , P >0 .05) . T here were 11 cases( 7 .7% ,11/143) with cardiovascular malformation and nine cases ( 6 .3% , 9/143 ) with digestive system malformation . Chromosome examination was performed in 23 cases . One case of trisomy 18‐trisomy and 1 case of trisomy 13‐trisomy were found to be with missing right umbilical artery and all of them were complicated with multiple deformities . Conclusions The absence of left and right umbilical artery can be combined with abnormal fetal malformation . Prenatal ultrasonography can accurately diagnose SU A and fetal malformation .
8.Comparison of effectiveness between two different modes of surgical intervention for the treatment of intracerebral hemorrhage in hypertensive patients
Huamin TANG ; Jianguo ZHOU ; Jianfeng ZHANG ; Huimin ZHAO ; Fei LONG ; Lixuan HUANG ; Guang ZENG
Chinese Journal of Emergency Medicine 2018;27(4):425-429
Objective To study the efficacy of two different modes of surgical intervention for the treatment of hypertensive intracerebral hemorrhage (HICH):YL-1 type hematoma removed by needle aspiration plus bio-enzyme liquefaction versus conventional craniectomy plus hematoma evacuation.Methods Medical records of 23 patients with HICH treated from December 2012 to February 2017 were retrospectively analyzed.The differences in demographics,length of operation time,costs and length of hospital stay,Glasgow Outcome Scale scores and 3-month follow-up results were compared between the YL-1 type hematoma removed by needle aspiration plus bio-enzyme liquefaction in 12 patients and conventional craniectomy plus hematoma evacuation in 11 patients.Results There were no significant differences in the gender (male 58.33% vs.63.64%,femal 41.67% vs.36.36%),age (65.5±11.8 years vs.56.8±10.1 years),preoperative GCS (6.83±3.93 vs.5.82±3.40),intracranial hematoma volume (50.52±23.07 mL vs.68.77±11.18 mL) and length of hospital stay (15.58±14.72 days vs.22.45±18.37 days) (P>0.05);There were statistically significant differences in length of operation time (0.73±0.21 h vs.3.92±0.67 h) and hospitalization costs (45 230.50±36 566.88 yuan of RMB vs.79 857.90±34 916.48 yuan of RMB) between two groups (P<0.05);Follow-up 3 months,there were no significant differences in rate of good recovery 33.3% vs.18.1%,severe disability rate (25.0% vs.27.3%) and mortality rate (41.7% vs.54.6%) between two groups (P>0.05).Conclusions The minimally invasive YL-1 type hematoma aspiration procedure with bio-enzyme liquefaction as a minimally invasive surgery may be superior to conventional craniectomy for treating HICH because it can offer shorter operation time,more accurate hematoma localization,lower risk of injury,and lower hospitalization costs.In particular,the procedure is suitable for elderly,frail,and poor general condition patients.It can also be applied as emergency treatment for HICH.
9.Continuous improvement of nursing care quality of orthopedic demonstration wards by taking hospital accreditation as an opportunity
Tianwen HUANG ; Ping XIAO ; Weiling ZHANG ; Lixuan FANG ; Xiaoxia LI ; Huilan ZHU
Modern Clinical Nursing 2017;16(7):59-62
Objective To explore the methods for quality management and continuous improvement of nursing care quality in the orthopedic demonstration ward by taking the hospital accreditation as an opportunity. Methods From July 2012 to June 2013, the continuous care quality improvement in the ward was carried out to find out the problems with PDCA (plan, do, check, action) cycle method, including enhancing the function of orthopedic nursing quality management groups, conducting all-staff training and improving the knowing rate by referring to the standards of hospital assessment standards. Results After the performance of whole-process quality management, the percentage of indexes assessed at level A, B and C was increased from 42.2%to 50.0%, 17.2%to 14.7%and 40.2%to 35.3%, respectively. The score of nurses' responsibility accreditation was increased from 92 to 95. The rates of patient and nursing staff satisfaction were increased from 91.8%to 98.9%and 92.57%to 97.7%, respectively. Conclusion In accordance with the standards for hospital accreditation, the continuous improvement of nursing quality in the orthopedic demonstration wards can improve the specialist care of orthopedic care, improve patients' and nurses' satisfaction, thus making the daily work more scientific and standardized.
10.Value of orbital division and imaging features in the diagnosis of orbital space-occupying lesions
Yan DONG ; Zisan ZENG ; Tao LI ; Lixuan HUANG
Journal of Practical Radiology 2017;33(7):992-995
Objective To investigate the value of the imaging division and features of CT and MRI in the differential diagnosis of benign and malignant space-occupying lesions.Methods A retrospective analysis of the clinical and imaging data of 201 patients with orbital space-occupying lesions confirmed by pathology was conducted.Four sector method was used to analyze the distribution of the lesions.The shape,border and relationship with surrounding tissues,MRI signal,CT density,and calcification of the orbital wall were also analyzed.Results There was statistical difference in the distribution of lesions in each of the 4-sector between orbital benign lesions and malignant tumors(χ2总=48.93,P=0.000).Lesions located in separate orbital zone including extra-periosteum compartment (18 cases),optic nerve compartment (4 cases),intraconal compartment(39 cases) were benign.Benign lesions (64%, 66/103) were more than malignant lesions (36%,37/103) in 103 lesions located in extraconal compartment.Additionally,there was significance in the distribution in separate and mixed zones between benign and malignant lesions(χ2=25.559,P=0.000).Benign lesions (77%,127/164) were more than malicious lesions(23%,37/164) in 164 cases in separate zone.Malignant lesions (65%,24/37) were more than benignant lesions (35%,13/37) in the 37 lesions located in mixed zone.Signs of CT and MRI:the benign and malignant lesions were 140 and 61,respectively.The features of those lesions are as follows(ratio=benign lesions/ malignant lesions):regular morphology(ratio=93/10),clear boundary(ratio=108/24),eyeball-surrounded (ratio=24/39),bone destruction (ratio=4/11).Features of lesions including shape,border,eyeball-surrounded, bone destruction had significant difference between benign and malignant lesions,whereas no differences was observed in calcification,signal on T1WI or T2WI,displacement of the eyeball and the occurrence of single or bilateral lesions.Conclusion The characteristic distribution of orbital space-occupying lesions based on the 4-sector and the features of CT and MRI has a great value in the diagnosis.

Result Analysis
Print
Save
E-mail