1.Reconstruction of lacunar bone defect caused by giant cell tumor of the distal femur with a 3D printed modular supporting prosthesis
Minxun LU ; Linyun TAN ; Xin HU ; Zihan PENG ; Zhuangzhuang LI ; Wacili DA ; Xuanhong HE ; Weiyi WANG ; Yitian WANG ; Yi LUO ; Chongqi TU ; Li MIN
Chinese Journal of Orthopaedics 2025;45(10):686-692
Objective:To observe the early clinical efficacy of 3D-printed modular supporting prosthesis for reconstruction of lacunar bone defect caused by giant cell tumor of the distal femur.Methods:From May 2018 to July 2023, a total of 9 patients with giant cell tumor of the distal femur were treated with 3D-printed modular supporting prosthesis to reconstruct lacunar bone defects in the Department of Orthopedics, West China Hospital, Sichuan University. There were 4 males and 5 females, aged 30.8±6.1 years (range, 24-44 years), 5 cases on the left side, 4 cases on the right side, 2 cases of Campanacci grade I, 7 cases of Campanacci grade II. The anteroposterior and lateral X-ray films and T-SMART tomosynthesis imaging of the knee joint were taken to observe the bone graft healing and osseointegration after operation. Musculoskeletal Tumor Society (MSTS)-93 was used to evaluate knee function, and visual analogue scale (VAS) was used to evaluate knee pain.Results:All patients were successfully operated and followed up for an average of 30.8±7.5 months (range, 18-42 months). The operation time was 124.2±23.6 min, and the intraoperative blood loss was 105.6±17.4 ml. All autografts showed bony union at the graft-host junction, and the healing time was 3.3±0.4 months (range, 3.0-4.0 months). At 6 months after surgery, T-SMART tomosynthesis imaging showed that the gap between the prosthesis-bone interface was less than 1 mm in all patients. At the last follow-up, the thickness of residual subchondral bone was 5.7±1.3 mm, which was greater than that before operation 2.2±0.8 mm, and the difference was statistically significant ( t=10.823, P<0.001). At the last follow-up, the score of MSTS-93 was 26.7±2.4, which was higher than that before operation 18.8±3.7, and the difference was statistically significant ( t=5.367, P<0.001). At the last follow-up, the range of motion of the knee joint was 122.8°±9.1°, which was higher than that before operation 108.3°±6.1°, and the difference was statistically significant ( t=3.970, P<0.001). All patients were able to walk normally, go up and down stairs and other daily activities, and 7 patients were able to complete squats. At the last follow-up, there was no local tumor recurrence, distant metastasis, death, joint infection, pain (VAS score was 0), delayed wound healing, joint degeneration, prosthesis loosening or articular surface collapse. Conclusion:Reconstruction of lacunar bone defect caused by giant cell tumor of distal femur with 3D-printed modular supporting prosthesis can effectively improve knee joint function and osseointegration, and the short-term clinical results are satisfactory.
2.The early and mid-term efficacy of three-dimensional printed customized porous prosthesis with preserved articular in the reconstruction of ultra-long segmental bone defect around the metaphysis of peri-knee
Jinyang LI ; Zhuangzhuang LI ; Taojun GONG ; Xin HU ; Linyun TAN ; Yong ZHOU ; Yi LUO ; Minxun LU ; Chongqi TU ; Li MIN
Chinese Journal of Orthopaedics 2025;45(11):735-741
Objective:To explore the early and mid-term efficacy of three-dimensional printed customized porous prosthesis with preserved articular in the reconstruction of ultra-long segmental bone defect around the metaphysis of peri-knee.Methods:A retrospective analysis was conducted on the data of 24 patients who underwent reconstruction of ultra-long segmental bone defect around the metaphysis of peri-knee using 3D-printed customized porous prostheses at West China Hospital of Sichuan University from June 2015 to June 2021. There were 14 female cases and 10 male cases, with an average age of 28.9±16.5 years (range, 12-61 years), 12 cases at the distal end of the femur and 12 cases at the proximal end of the tibia. Tumor types: 16 cases of osteosarcoma, 4 cases of Ewing's sarcoma, 2 cases of chondrosarcoma, and 2 case of parosteal osteosarcoma. All patients were classified as Enneking stage IIB. Record the oncology results of the patients, the length of tumor segment resection, and the remaining bone length at the distal femur or proximal tibia, as well as complications, systemic metastasis and imaging changes. The bone integration at the prosthesis-bone interface was evaluated by tomosynthesis-shimadzu metal artifact reduction technology (T-SMART). Limb function was evaluated using the Musculoskeletal Tumor Society (MSTS)-93 score and knee range of motion assessment.Results:All 24 patients successfully completed the surgery and were followed up, with an average follow-up time of 51.8±12.7 months (range, 32-99 months). The length of femoral osteotomy was 241.1±66.2 mm (range, 150.6-333.4 mm), and the length of tibial osteotomy was 198.6±35.6 mm (range, 156.6-287.6 mm). The remaining bone length at the epiphyseal end around the knee joint (from the knee joint plane to the osteotomy plane of the distal femur or proximal tibia) was 52.6±11.0 mm (range, 31.1-77.5 mm). At the last follow-up, 23 patients survived tumor-free, while one patient died due to lung metastasis 54 months after the operation. One patient had prosthesis fracture 75 months after the operation, two patients had aseptic loosening 6 and 8 months after the operation, and the T-SMART of the remaining 20 patients showed that the implanted prostheses all achieved good osseointegration. At the last follow-up, the range of motion of the knee joint was 126.2°±7.5° (range, 110.0°-140.0°), and the MSTS-93 score was 26.7±1.8 points (range, 23-30 points). Among them, the MSTS-93 score of the femoral prosthesis was 26.7±1.6 points (range, 24-29 points), and the MSTS-93 score of the tibial prosthesis was 26.9±1.9 points (range, 23-30 points). The average knee range of motion was 126.2°±7.5° (range, 110°-140°), and the MSTS-93 functional score was 26.7±1.8 points (range, 23-30 points) at the last follow-up. The femoral component had an average score of 26.7±1.6 points (range, 24-29 points), while the tibial component had an average score of 26.9±1.9 points (range, 23-30 points).Conclusion:The application three-dimensional printed customized porous prosthesis with preserved articular in the reconstruction of ultra-long segmental bone defect around the metaphysis of peri-knee can preserve the joint, restore limb function well, and have a low incidence of prosthesis complications, with good clinical efficacy in the early and middle stages.
3.Early follow-up study on three-dimensional-printed customized porous acetabular components for reconstructing extensive acetabular bone defects in primary total hip arthroplasty.
Shangkun TANG ; Zhuangzhuang LI ; Xin HU ; Linyun TAN ; Hao WANG ; Yitian WANG ; Minxun LU ; Fan TANG ; Yi LUO ; Yong ZHOU ; Chongqi TU ; Li MIN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1543-1550
OBJECTIVE:
To evaluate the feasibility and short-term effectiveness of three-dimensional (3D)-printed customized porous acetabular components for reconstruction of extensive acetabular bone defects during primary total hip arthroplasty (THA).
METHODS:
The clinical data of 8 patients with extensive acetabular bone defects, who were treated with 3D-printed individualized porous acetabular components between July 2018 and January 2022, were retrospectively analyzed. The cohort comprised 4 males and 4 females with an average age of 48 years ranging from 34 to 56 years. Acetabular bone defects were classified as Paprosky type ⅢA in 3 cases and type ⅢB in 5 cases. The causes of acetabular destruction were hip tuberculosis (5 cases), pigmented villonodular synovitis (2 cases), and syphilitic arthritis (1 case). Visual analogue scale (VAS) score and Harris hip score (HHS) were used to evaluate the pain relief and hip function before and after operation. Reconstruction outcomes were further assessed by imaging results [X-ray film and Tomosynthesis Shimadzumetal artefact reduction technology (T-SMART)], and the mechanical properties were evaluated by finite element analysis.
RESULTS:
The operation time ranged from 174 to 195 minutes (mean, 187 minutes), and intraoperative blood loss ranged from 390 to 530 mL (mean, 465 mL). All 8 patients were follow-up 26-74 months (mean, 44 months). Among the 5 patients with tuberculosis, none experienced postoperative recurrence. At last follow-up, the VAS score was 0.3±0.5 and the HHS score was 87.9±3.7, both significantly improved compared to preoperative values ( t=25.170, P<0.001; t=-28.322, P<0.001). X-ray films at 2 years after operation demonstrated satisfactory matching between the 3D-printed customized acetabular component and the acetabulum. The postoperative center of rotation of the operated hip was shifted by (2.1±0.5) mm horizontally and (2.0±0.7) mm vertically relative to the contralateral side, with both offsets showing significant differences compared to preoperative values ( t=24.700, P<0.001; t=55.230, P<0.001). T-SMART imaging showed satisfactory osseointegration at the implant-host bone interface. No complications such as aseptic loosening or screw breakage was observed during follow-up. Finite element analysis showed that the acetabular component had good mechanical properties.
CONCLUSION
The application of 3D-printed individualized porous acetabular components in the reconstruction of extensive acetabular bone defects demonstrated precise anatomical reconstruction, stable mechanical support, and good functional performance in short-term follow-up, offering a potential alternative for acetabular defect reconstruction in primary THA.
Humans
;
Middle Aged
;
Male
;
Female
;
Printing, Three-Dimensional
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Acetabulum/diagnostic imaging*
;
Adult
;
Follow-Up Studies
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Porosity
;
Treatment Outcome
;
Plastic Surgery Procedures/methods*
4.Reconstruction of lacunar bone defect caused by giant cell tumor of the distal femur with a 3D printed modular supporting prosthesis
Minxun LU ; Linyun TAN ; Xin HU ; Zihan PENG ; Zhuangzhuang LI ; Wacili DA ; Xuanhong HE ; Weiyi WANG ; Yitian WANG ; Yi LUO ; Chongqi TU ; Li MIN
Chinese Journal of Orthopaedics 2025;45(10):686-692
Objective:To observe the early clinical efficacy of 3D-printed modular supporting prosthesis for reconstruction of lacunar bone defect caused by giant cell tumor of the distal femur.Methods:From May 2018 to July 2023, a total of 9 patients with giant cell tumor of the distal femur were treated with 3D-printed modular supporting prosthesis to reconstruct lacunar bone defects in the Department of Orthopedics, West China Hospital, Sichuan University. There were 4 males and 5 females, aged 30.8±6.1 years (range, 24-44 years), 5 cases on the left side, 4 cases on the right side, 2 cases of Campanacci grade I, 7 cases of Campanacci grade II. The anteroposterior and lateral X-ray films and T-SMART tomosynthesis imaging of the knee joint were taken to observe the bone graft healing and osseointegration after operation. Musculoskeletal Tumor Society (MSTS)-93 was used to evaluate knee function, and visual analogue scale (VAS) was used to evaluate knee pain.Results:All patients were successfully operated and followed up for an average of 30.8±7.5 months (range, 18-42 months). The operation time was 124.2±23.6 min, and the intraoperative blood loss was 105.6±17.4 ml. All autografts showed bony union at the graft-host junction, and the healing time was 3.3±0.4 months (range, 3.0-4.0 months). At 6 months after surgery, T-SMART tomosynthesis imaging showed that the gap between the prosthesis-bone interface was less than 1 mm in all patients. At the last follow-up, the thickness of residual subchondral bone was 5.7±1.3 mm, which was greater than that before operation 2.2±0.8 mm, and the difference was statistically significant ( t=10.823, P<0.001). At the last follow-up, the score of MSTS-93 was 26.7±2.4, which was higher than that before operation 18.8±3.7, and the difference was statistically significant ( t=5.367, P<0.001). At the last follow-up, the range of motion of the knee joint was 122.8°±9.1°, which was higher than that before operation 108.3°±6.1°, and the difference was statistically significant ( t=3.970, P<0.001). All patients were able to walk normally, go up and down stairs and other daily activities, and 7 patients were able to complete squats. At the last follow-up, there was no local tumor recurrence, distant metastasis, death, joint infection, pain (VAS score was 0), delayed wound healing, joint degeneration, prosthesis loosening or articular surface collapse. Conclusion:Reconstruction of lacunar bone defect caused by giant cell tumor of distal femur with 3D-printed modular supporting prosthesis can effectively improve knee joint function and osseointegration, and the short-term clinical results are satisfactory.
5.The early and mid-term efficacy of three-dimensional printed customized porous prosthesis with preserved articular in the reconstruction of ultra-long segmental bone defect around the metaphysis of peri-knee
Jinyang LI ; Zhuangzhuang LI ; Taojun GONG ; Xin HU ; Linyun TAN ; Yong ZHOU ; Yi LUO ; Minxun LU ; Chongqi TU ; Li MIN
Chinese Journal of Orthopaedics 2025;45(11):735-741
Objective:To explore the early and mid-term efficacy of three-dimensional printed customized porous prosthesis with preserved articular in the reconstruction of ultra-long segmental bone defect around the metaphysis of peri-knee.Methods:A retrospective analysis was conducted on the data of 24 patients who underwent reconstruction of ultra-long segmental bone defect around the metaphysis of peri-knee using 3D-printed customized porous prostheses at West China Hospital of Sichuan University from June 2015 to June 2021. There were 14 female cases and 10 male cases, with an average age of 28.9±16.5 years (range, 12-61 years), 12 cases at the distal end of the femur and 12 cases at the proximal end of the tibia. Tumor types: 16 cases of osteosarcoma, 4 cases of Ewing's sarcoma, 2 cases of chondrosarcoma, and 2 case of parosteal osteosarcoma. All patients were classified as Enneking stage IIB. Record the oncology results of the patients, the length of tumor segment resection, and the remaining bone length at the distal femur or proximal tibia, as well as complications, systemic metastasis and imaging changes. The bone integration at the prosthesis-bone interface was evaluated by tomosynthesis-shimadzu metal artifact reduction technology (T-SMART). Limb function was evaluated using the Musculoskeletal Tumor Society (MSTS)-93 score and knee range of motion assessment.Results:All 24 patients successfully completed the surgery and were followed up, with an average follow-up time of 51.8±12.7 months (range, 32-99 months). The length of femoral osteotomy was 241.1±66.2 mm (range, 150.6-333.4 mm), and the length of tibial osteotomy was 198.6±35.6 mm (range, 156.6-287.6 mm). The remaining bone length at the epiphyseal end around the knee joint (from the knee joint plane to the osteotomy plane of the distal femur or proximal tibia) was 52.6±11.0 mm (range, 31.1-77.5 mm). At the last follow-up, 23 patients survived tumor-free, while one patient died due to lung metastasis 54 months after the operation. One patient had prosthesis fracture 75 months after the operation, two patients had aseptic loosening 6 and 8 months after the operation, and the T-SMART of the remaining 20 patients showed that the implanted prostheses all achieved good osseointegration. At the last follow-up, the range of motion of the knee joint was 126.2°±7.5° (range, 110.0°-140.0°), and the MSTS-93 score was 26.7±1.8 points (range, 23-30 points). Among them, the MSTS-93 score of the femoral prosthesis was 26.7±1.6 points (range, 24-29 points), and the MSTS-93 score of the tibial prosthesis was 26.9±1.9 points (range, 23-30 points). The average knee range of motion was 126.2°±7.5° (range, 110°-140°), and the MSTS-93 functional score was 26.7±1.8 points (range, 23-30 points) at the last follow-up. The femoral component had an average score of 26.7±1.6 points (range, 24-29 points), while the tibial component had an average score of 26.9±1.9 points (range, 23-30 points).Conclusion:The application three-dimensional printed customized porous prosthesis with preserved articular in the reconstruction of ultra-long segmental bone defect around the metaphysis of peri-knee can preserve the joint, restore limb function well, and have a low incidence of prosthesis complications, with good clinical efficacy in the early and middle stages.
6.Short-term outcomes of reconstruction of tumorous critical bone defects at femoral shaft with a 3D printed ultra-short stem with a porous structure
Guifeng DU ; Jie WANG ; Xin HU ; Yang WEN ; Linyun TAN ; Minxun LU ; Yuqi ZHANG ; Yong ZHOU ; Yi LUO ; Li MIN ; Chongqi TU
Chinese Journal of Orthopaedic Trauma 2022;24(9):805-811
Objective:To explore the short-term outcomes of reconstruction of tumorous critical bone defects at femoral shaft with a 3D printed ultra-short stem with a porous structure.Methods:From September 2016 to June 2018, 8 patients underwent reconstruction of critical bone defects with a 3D printed ultra-short stem with a porous structure after resection of femoral shaft malignant tumor at Department of Orthopaedics, West China Hospital. There were 4 males and 4 females, with an average age of 36.9 years (from 11 to 61 years). Their preoperative Enneking staging was stage Ⅱb in all. There were 3 osteosarcomas, 2 Ewing sarcomas, 2 chondrosarcomas and one periosteal osteosarcoma. Preoperative CT/MRI image fusion technology was used to define the surgical boundary, design the guide plate and prosthesis, and perform surgical simulation. Tomosynthesis-shimadzu Metal Artefact Reduction technology was used to evaluate osseointegration. Complications and bone oncology prognosis of the patients were documented. The lower limb function of the patients was evaluated using Musculoskeletal Tumor Society (MSTS) 1993 scoring and knee range of motion.Results:The overall follow-up time ranged from 36 to 50 months, averaging 42.8 months. During operation one patient sustained a periprosthesis fracture, the union of which was followed up after wire assisted fixation. There was no local tumor recurrence, lung metastasis or death. The last follow-up revealed good osseointegration and basically isometric lower extremities in all cases. There was no such a complication as aseptic loosening of the prosthesis, deep infection or prosthesis fracture during the follow-up period. At the last follow-up in the 8 patients, the flexion range of the knee joint was 116.2°±9.1°, significantly improved compared with that before operation (98.8°±10.9°), and the MSTS score was (26.2±2.1) points, also significantly improved compared with that before operation [(21.6±1.8) points] ( P<0.05). Conclusions:Reconstruction with a 3D printed ultra-short stem with a porous structure is an accurate operation for femoral shaft tumorous bone defects. With careful preoperative design, intraoperative manipulation and strict postoperative follow-up management, this operation can lead to fine early curative outcomes for long shaft critical bone defects.
7.Safety and immunogenicity of combined immunization with live rotavirus vaccine (oral) and measles, mumps and rubella vaccine
Xiaoqin LIU ; Qi QI ; Yu LIU ; Yuan YANG ; Min ZHANG ; Haiping CHEN ; Yanhui XIAO ; Linyun LUO
Chinese Journal of Microbiology and Immunology 2022;42(4):317-322
Objective:To evaluate the difference in safety and immunogenicity of live rotavirus vaccine (oral) and measles, mumps and rubella (MMR) vaccine immunized alone or in combination.Methods:This study recruited 1 752 children aged 8-9 months who had not been vaccinated with live rotavirus vaccine (oral) or MMR vaccine after birth. The subjects were divided into three groups: study group (652 subjects, immunized with live rotavirus vaccine and MMR vaccine), control group 1 (723 subjects, immunized with live rotavirus vaccine) and control group 2 (377 subjects, immunized with MMR vaccine). Local and systemic adverse reactions within 30 d after vaccination were recorded. Serum samples were collected before and 35-42 d after immunization for analyzing the changes in antibodies.Results:Immunization alone or in combination with live rotavirus vaccine (oral) and MMR vaccine achieved similar results in the positive rates and concentrations of antibodies against rotavirus, measles and rubella viruses ( P>0.05). Moreover, the positive rates and the concentrations of the three antibodies were increased after vaccination. Compared with the control group 2, the concentration of antibody against mumps virus in the study group was increased ( P<0.05), but no significant difference in the positive rate of antibody against mumps virus was found between the two groups ( P>0.05). The positive rate and the concentration of antibody against mumps virus were increased after combined immunization or immunization with MMR vaccine alone. The overall incidence of fever and diarrhea was 1.54% (27/1 752) and 0.63% (11/1 752). No other abnormal reactions, incidental reactions or adverse reactions of any clinical significance were observed. Conclusions:Live rotavirus vaccine (oral) and MMR vaccine immunized alone or in combination showed good immunogenicity and safety.
8.Immunogenicity and safety of a boost dose of measles, mumps, and rubella combined vaccine for 4-6 years old children
Yanhui XIAO ; Shaoying CHANG ; Shuang BAI ; Runmao ZHAO ; Jiehong WANG ; Xueqiu WANG ; Yunkai YANG ; Yanli MA ; Xiaoqin LIU ; Linyun LUO ; Min LYU ; Haiping CHEN
Chinese Journal of Epidemiology 2021;42(6):1086-1091
Objective:To investigate the immunogenicity and safety of a boost dose of measles, mumps, and rubella combined vaccine (MMR) for children 4 to 6 years old.Methods:Children, aged 4 to 6 years old, had vaccinated with 1 dose of measles and rubella combined vaccine(MR) at the age of 8 months and 1 dose of MMR vaccine at 18-months, were recruited in Shanxi, Inner Mongolia, and Beijing, respectively. All children were assigned into 4, 5 and 6-year-old group. The children who met inclusion and exclusion criteria were vaccinated with 1 dose MMR vaccine, and were collected blood samples before vaccination and 35 to 42 d after the vaccination. During the study period, adverse events were collected at 30 min, 1 d, 2 d, 3 d, 4-12 d, and 13 to 42 days after vaccination. Serum was tested for IgG antibodies against measles, mumps and rubella. Geometric mean concentrations (GMC) of measles, mumps, and rubella antibodies were compared among groups by analysis of variance or non-parametric test. Seropositive rates and adverse event rates were compared among groups by Chi-square test or Fisher exact test.Results:A total of 500 children were included in immunogenicity analysis and 535 children were included in safety analysis. The overall adverse event rate was 20.37%, the most of severity for adverse events was mild. The rates of local and systemic adverse events were 0.37% and 20.00%, respectively. Symptoms of local adverse events were redness. The main systemic adverse events were fever, followed by cough, rash and runny nose. Received a dose of MMR vaccine for booster immunization, the seropositive rates of measles antibody, mumps antibody and rubella antibody were above 99% for all 3 age groups, and there was no significant difference between groups. There were significant differences in mumps antibody GMC among groups ( P=0.042), but no significant differences in measles and rubella antibodies GMC. Conclusion:The immunogenicity and safety of a boosted MMR vaccintion in children aged 4, 5 and 6 years were all similar good.
9.Analysis of post-marketing safety monitoring of split influenza virus vaccine based on large samples
Peng DENG ; Qiong LI ; Xiaoai QIAN ; Xue GUO ; Haiping CHEN ; Xiaoqin LIU ; Xuanwen SHI ; Wei JIANG ; Jianjun YE ; Faixian ZHAN ; Beifang YANG ; Linyun LUO
Journal of Public Health and Preventive Medicine 2020;31(3):33-35
Objective To evaluate the safety of a Chinese thimerosal-free trivalent split influenza virus vaccine after being marketed in a large population. Methods Through the information management system of adverse event following immunization (AEFI), the adverse events in healthy people aged 6 months and above who were vaccinated with split influenza virus vaccine in Hubei Province from October to December 2015 were collected. The data was analyzed by descriptive methodology. Results From October 1, 2015 to June 30, 2016, among the 227 920 people in Hubei Province who were vaccinated with split influenza virus vaccine, the common adverse reactions were mainly fever, redness, irritability, pain and itching. Four cases of AEFI were passively observed and reported in the system, with a reporting rate of 1.76/100 000, among which 3 cases were anaphylactic rash and 1 case was optic neuritis. Conclusion The Chinese thimerosal-free trivalent split influenza virus vaccine used in Hubei Province had a good safety record and is suitable for the general vaccination of people without vaccination contraindications.
10.Antibody persistence 3 to 5 years after vaccination with measles, mumps and rubella combined attenuated live vaccine in children
Ming GUANG ; Yanhui XIAO ; Shaohong YAN ; Li SUN ; Wei ZHAO ; Weixin CHEN ; Yunqiang DONG ; Xinghua SHI ; Na WANG ; Weiwei FAN ; Yunkai YANG ; Xiaoqin LIU ; Haiping CHEN ; Zhenguo ZHANG ; Linyun LUO
Chinese Journal of Microbiology and Immunology 2020;40(9):714-719
Objective:To assess the antibody persistence 3-5 years following vaccination of measles and rubella combined live-attenuated vaccine (MR) at 8 months of age and measles, mumps and rubella combined attenuated live vaccine (MMR) at 18 months of age.Methods:In 2016, 18-month-old children who were vaccinated with one dose of MR vaccine at the age of 8 months were recruited in Hebei Province as group 1; 4-, 5- and 6-year-old children who were vaccinated with one dose of MR vaccine at the age of 8 months and one dose of MMR vaccine at 18 months of age were recruited in Shanxi, Inner Mongolia and Beijing as group 2, group 3 and group 4, respectively. Serum samples were collected to detect IgG antibodies against measles, mumps and rubella by ELISA. Geometric mean concentrations (GMCs) of measles, mumps, and rubella antibodies were compared among groups by analysis of variance or non-parametric test. Seropositive rates were compared among groups by Chi-square test or Fisher′s exact test. Results:A total of 650 children were included in this study. Seropositive rates of measles, mumps and rubella antibodies 30 d after vaccination of 150 18-month-old children with one dose of MMR vaccine were 100%, 91.33% and 100%, respectively, and the GMCs were 1 846.87 mIU/ml, 299.91 IU/ml and 111.33 IU/ml, respectively. Seropositive rates of measles, mumps and rubella antibodies 3-5 years after vaccination one dose of MR vaccine at 8 months of age and one dose of MMR vaccine at 18 months of age were above 94%, 79% and 71%, respectively, and the GMCs were above 830 mIU/ml, 240 IU/ml and 31 IU/ml. No significant difference in the seropositive rates of the three antibodies was observed among groups 2, 3 and 4 ( P>0.05). There was no significant difference in the GMCs of measles or mumps antibodies among the three groups ( P>0.05), but the differences in the GMCs of rubella antibodies were statistically significant ( P=0.034). Conclusions:Measles, mumps and rubella antibodies persisted for 3-5 years without significant decrease after vaccination one dose of MR vaccine at 8 months of age and one dose of MMR vaccine at 18 months of age.