1.A real-time process monitoring scheme for blood center NAT using the median of internal control CT value
Yuntao XU ; Jiaqiang ZHU ; Zuomei YIN ; Li MU ; Huiping ZHANG ; Xingfeng ZHANG ; Lijing QIAO
Chinese Journal of Blood Transfusion 2026;39(3):391-396
Objective: To establish a real-time quality control scheme based on the median (MD-IC) of internal control cycle threshold value in negative samples (NEG-IC-CT), so as to monitor anomalies such as progressive drift in nucleic acid testing system not covered by conventional internal quality control (IQC) in blood center nucleic acid laboratories, and to verify its feasibility. Methods: The internal control CT values of 54 426 negative samples were retrospectively collected. These samples were from four reagent batches of the two new and old equipment sets during the operation of the Wantai nucleic acid testing system in our blood center. The daily median of NEG-IC-CT values was used as the research indicator. Control limits were calculated using median absolute deviation (MAD) to construct the Median-MAD quality control chart. The monitoring performance of this scheme for the operation status of the testing system was simultaneously evaluated. Results: Statistical analysis showed significant differences in NEG-IC-CT value distribution between the new and old equipment sets, as well as between the two different reagent batches of the old equipment (P<0.000 1). The NEG-IC-CT value performance of the two different reagent batches of the new equipment was no significant difference in distribution (P>0.05). This scheme identified three typies of distinct anomalies. The out-of-control events observed with the old equipment in both the O1 and O2 reagent batches suggested potential performance decay due to equipment aging. The unreported change of reagent batch in time of Phase B with new equipment caused a stepwise drift on the quality control chart. In the later stage of Phase A with the new equipment, an alert was triggered, indicating potential quality risks associated with practices such as the mixed use of the remaining reagents and extremely long operator working hours. Conclusion: The realtime quality control scheme based on NEG-IC-CT value established in this study has been preliminarily validated for its monitoring effectiveness in nucleic acid testing in our blood center. This scheme performed well in detecting differences among testing systems and reagent batches, serving as an effective supplement to routine internal quality control. It can provide an intuitive and effective evaluation method for monitoring the performance of the nucleic acid testing process at blood center.
2.A Case of Multidisciplinary Treatment for Inflammatory Myofibroblastic Tumor Complicated by ANCA-Associated Vasculitis
Shaoying WANG ; Linyi PENG ; Ke ZHENG ; Zhiwei WANG ; Dachun ZHAO ; Xia ZHANG ; Lin ZHAO ; Wenhui WANG ; Weiqing WANG ; Zhenzhen ZHU ; Jin XU ; Min SHEN
JOURNAL OF RARE DISEASES 2026;5(1):43-51
A 51-year-old male presented with nasal obstruction, followed by progressive hearing loss and blurred vision. Imaging identified space-occupying lesions in the paranasal sinuses, orbits, and paraspinal regions, while laboratory tests confirmed positive anti-proteinase 3 anti-neutrophil cytoplasmic antibody(PR3- ANCA) immunoglobulin G (IgG)and markedly elevated serum IgG4. Despite treatment with corticosteroids, immunosuppressants, and radiotherapy, the patient exhibited steroid dependency with relentless disease progression. Following multidisciplinary consultation, a diagnosis of inflammatory myofibroblastic tumor (IMT) coexisting with ANCA- associated vasculitis (AAV) was favored, though IgG4-related disease remained a critical differential. Ultimately, profound immunosuppression precipitated a severe herpesvirus infection, leading to disseminated intravascular coagulation and multiple organ dysfunction syndrome. This case underscores the rarity and diagnostic complexity of concurrent IMT and AAV, highlights the therapeutic dilemma of balancing primary disease control against fatal opportunistic infections, and emphasizes the critical role of multidisciplinary collaboration in the diagnosis and treatment of complex diseases.
3.Expert consensus on the diagnosis and treatment of cemental tear.
Ye LIANG ; Hongrui LIU ; Chengjia XIE ; Yang YU ; Jinlong SHAO ; Chunxu LV ; Wenyan KANG ; Fuhua YAN ; Yaping PAN ; Faming CHEN ; Yan XU ; Zuomin WANG ; Yao SUN ; Ang LI ; Lili CHEN ; Qingxian LUAN ; Chuanjiang ZHAO ; Zhengguo CAO ; Yi LIU ; Jiang SUN ; Zhongchen SONG ; Lei ZHAO ; Li LIN ; Peihui DING ; Weilian SUN ; Jun WANG ; Jiang LIN ; Guangxun ZHU ; Qi ZHANG ; Lijun LUO ; Jiayin DENG ; Yihuai PAN ; Jin ZHAO ; Aimei SONG ; Hongmei GUO ; Jin ZHANG ; Pingping CUI ; Song GE ; Rui ZHANG ; Xiuyun REN ; Shengbin HUANG ; Xi WEI ; Lihong QIU ; Jing DENG ; Keqing PAN ; Dandan MA ; Hongyu ZHAO ; Dong CHEN ; Liangjun ZHONG ; Gang DING ; Wu CHEN ; Quanchen XU ; Xiaoyu SUN ; Lingqian DU ; Ling LI ; Yijia WANG ; Xiaoyuan LI ; Qiang CHEN ; Hui WANG ; Zheng ZHANG ; Mengmeng LIU ; Chengfei ZHANG ; Xuedong ZHOU ; Shaohua GE
International Journal of Oral Science 2025;17(1):61-61
Cemental tear is a rare and indetectable condition unless obvious clinical signs present with the involvement of surrounding periodontal and periapical tissues. Due to its clinical manifestations similar to common dental issues, such as vertical root fracture, primary endodontic diseases, and periodontal diseases, as well as the low awareness of cemental tear for clinicians, misdiagnosis often occurs. The critical principle for cemental tear treatment is to remove torn fragments, and overlooking fragments leads to futile therapy, which could deteriorate the conditions of the affected teeth. Therefore, accurate diagnosis and subsequent appropriate interventions are vital for managing cemental tear. Novel diagnostic tools, including cone-beam computed tomography (CBCT), microscopes, and enamel matrix derivatives, have improved early detection and management, enhancing tooth retention. The implementation of standardized diagnostic criteria and treatment protocols, combined with improved clinical awareness among dental professionals, serves to mitigate risks of diagnostic errors and suboptimal therapeutic interventions. This expert consensus reviewed the epidemiology, pathogenesis, potential predisposing factors, clinical manifestations, diagnosis, differential diagnosis, treatment, and prognosis of cemental tear, aiming to provide a clinical guideline and facilitate clinicians to have a better understanding of cemental tear.
Humans
;
Dental Cementum/injuries*
;
Consensus
;
Diagnosis, Differential
;
Cone-Beam Computed Tomography
;
Tooth Fractures/therapy*
4.A qualitative study on the functional requirements of the Internet platform for remote rehabilitation management of patients after arthroscopic surgery
Linyi ZHU ; Lingying HUANG ; Fei XIONG ; Simiao ZHANG ; Huina ZHANG ; Qiuwen YING ; Jingyi MI
Chinese Journal of Practical Nursing 2025;41(6):408-416
Objective:To understand the functional requirements and suggestions of relevant stakeholders on the Internet platform for remote rehabilitation management of patients after arthroscopy, so as to provide a reference basis for building a home rehabilitation management scheme and developing a remote Internet platform.Methods:Based on the technology acceptance model, a descriptive qualitative study was conducted using purposive sampling and maximum difference method to select 11 arthroscopic postoperative patients, 4 patient caregivers, and 7 clinical professionals from the Sports Medicine Department of Wuxi Ninth People′s Hospital (Orthopaedic Hospital) from October to December 2022. A total of 22 stakeholders were interviewed in a semi-structured manner, and the Colaizzi was used to analyze the interview data.Results:Among 22 interviewers, 12 males, 10 females, aged 25-65 years. A total of four topics were summarized: the willingness to use the Internet platform for remote rehabilitation management, the demand for the content provided by the Internet platform for remote rehabilitation management, the demand for the module functions of the Internet platform for remote rehabilitation management, and the demand for the operability of the Internet platform for remote rehabilitation management.Conclusions:The general attitude of the stakeholder groups towards the use of the Internet platform for remote rehabilitation management of patients after arthroscopy is positive. It is hoped that the platform will have diversified functions and good usability, improve the compliance and enthusiasm of patients in home rehabilitation exercise, and thus promote the recovery of limb function.
5.A qualitative study on the functional requirements of the Internet platform for remote rehabilitation management of patients after arthroscopic surgery
Linyi ZHU ; Lingying HUANG ; Fei XIONG ; Simiao ZHANG ; Huina ZHANG ; Qiuwen YING ; Jingyi MI
Chinese Journal of Practical Nursing 2025;41(6):408-416
Objective:To understand the functional requirements and suggestions of relevant stakeholders on the Internet platform for remote rehabilitation management of patients after arthroscopy, so as to provide a reference basis for building a home rehabilitation management scheme and developing a remote Internet platform.Methods:Based on the technology acceptance model, a descriptive qualitative study was conducted using purposive sampling and maximum difference method to select 11 arthroscopic postoperative patients, 4 patient caregivers, and 7 clinical professionals from the Sports Medicine Department of Wuxi Ninth People′s Hospital (Orthopaedic Hospital) from October to December 2022. A total of 22 stakeholders were interviewed in a semi-structured manner, and the Colaizzi was used to analyze the interview data.Results:Among 22 interviewers, 12 males, 10 females, aged 25-65 years. A total of four topics were summarized: the willingness to use the Internet platform for remote rehabilitation management, the demand for the content provided by the Internet platform for remote rehabilitation management, the demand for the module functions of the Internet platform for remote rehabilitation management, and the demand for the operability of the Internet platform for remote rehabilitation management.Conclusions:The general attitude of the stakeholder groups towards the use of the Internet platform for remote rehabilitation management of patients after arthroscopy is positive. It is hoped that the platform will have diversified functions and good usability, improve the compliance and enthusiasm of patients in home rehabilitation exercise, and thus promote the recovery of limb function.
6.Analysis of phenotype formation mechanism of a new variety of Lonicera japonica Flos "Huajin 6" at long bud stage
Run-zhu LI ; Cong-lian LIANG ; Zhen-hua LIU ; Jia LI ; Yong-qing ZHANG ; Hai-yan LIU ; Gao-bin PU
Acta Pharmaceutica Sinica 2024;59(2):476-481
Based on the long bud stage phenotype of a new
7.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
8.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
9.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
10.Genetic analysis and prenatal diagnosis of a child with Multiple congenital malformations-hypotonia-epilepsy syndrome type 3 due to variants of PIGT gene.
Ying HUA ; Li YANG ; Shaoxia SUN ; Yufen LI ; Yuzeng HAN ; Liping ZHU ; Na XU ; Shiyan QIU
Chinese Journal of Medical Genetics 2023;40(9):1140-1145
OBJECTIVE:
To explore the clinical features and genetic etiology of a child with Multiple congenital malformations-hypotonia-epilepsy syndrome type 3 (MCAHS3) and provide prenatal diagnosis for her parents.
METHODS:
A female child who had presented at Linyi People's Hospital on 27 July 2022 for recurrent convulsions for over 4 years was selected as the study subject. Clinical data of the child were collected. Peripheral blood samples were taken from the child and her parents and subjected for whole exome sequencing (WES). Candidate variants were verified by Sanger sequencing. Prenatal diagnosis was carried out on amniotic fluid sample at 18 weeks' gestation. Bioinformatic software was used to analyze the pathogenicity of the protein model for the variant loci.
RESULTS:
The child was a 4-year-old female with frequent seizures, peculiar facial appearance, hypotonia and severe developmental delay. Genetic analysis revealed that she has harbored compound heterozygous variants of the PIGT gene, namely c.1126del (p.H376Tfs*56) and c.1285G>C (p.E429Q), which were respectively inherited from her mother and father. Based on the guidelines from the American College of Medical Genetics and Genomics, the c.1126del (p.H376Tfs*56) variant was predicted to be pathogenic (PVS1+PM2_Supporting+PM4), and c.1285G>C (p.E429Q) variant was predicted to be likely pathogenic (PM2_Supporting+PM3+PM4). Prenatal diagnosis suggested that the fetus also harbored the same compound heterozygous variants, and the pregnancy was terminated with induced labor.
CONCLUSION
The c.1126del (p.H376Tfs*56) and c.1285G>C (p.E429Q) compound heterozygous variants of the PIGT gene probably underlay the MCAHS3 in this patient, and prenatal diagnosis has prevented birth of further affected child in this family.
Humans
;
Female
;
Child
;
Pregnancy
;
Child, Preschool
;
Muscle Hypotonia/genetics*
;
Prenatal Diagnosis
;
Computational Biology
;
Epileptic Syndromes
;
Facies

Result Analysis
Print
Save
E-mail