1.Surface electromyogram assessment of effectiveness of anti-G straining maneuver of high performance fighter pilots
Jinghui YANG ; Baohui LI ; Yan XU ; Haixia WANG ; Zhao JIN ; Xichen GENG ; Hong WANG ; Xiaoyang WEI ; Ke JIANG ; Yifeng LI ; Lihui ZHANG ; Xiaoxue ZHANG ; Minghao YANG
Chinese Journal of Aerospace Medicine 2025;36(2):113-118
Objective:To evaluate the effectiveness of anti-G straining maneuver (AGSM) in pilots by surface electromyography (sEMG), and to explore the relationships between characteristics of sEMG and anti-G endurance in pilots.Methods:Thirty-eight male high-performance fighter pilots who completed the human centrifuge test at the Air Force Medical Center were selected. Among them, 25 completed the 8.0 G for 10 s anti-G endurance test and 13 completed the 9.0 G for 10 s anti-G endurance test. The sEMG tester was used to keep track of the changes of sEMG in rectus abdominis, rectus femoris, anterior tibial and gastrocnemius muscles while pilots were engaged in AGSM. The anti-G endurance was evaluated according to the changes of visual fields and consciousness. The pilots were divided into 3 groups: the good vision and consciousness group, peripheral visual field narrowing group and endurance endpoint group. The differences in the integral electromyogram (iEMG), mean power frequency (MPF) and muscle input rates between the 3 groups were investigated.Results:A total of 25 pilots completed the 8.0 G for 10 s anti-G endurance test. Among them, 8 (32.0%) were in the good vision and consciousness group, 13 (52.0%) in the peripheral visual field narrowing group and 4 (16.0%) reached the endurance endpoint. Among the 13 pilots who completed the 9.0 G for 10 s anti-G endurance test, 3 (23.1%) were in the good vision and consciousness group, 6 (46.1%) in the peripheral visual field narrowing group, and 4 (30.8%) in the endurance endpoint group. The results of sEMG showed that the iEMG values of the anterior tibialis muscle in pilots under the 9.0 G for 10 s load were significantly different across endurance groups ( H=7.54, P=0.023), and that the iEMG values of the tibialis anterior muscle in the good vision and consciousness group were higher than those in the endurance endpoint group ( P=0.036). The negative slopes of MPF for the rectus abdominis, rectus femoris, anterior tibialis, and gastrocnemius muscles were higher in the good vision and consciousness group than in the other 2 groups, but the differences were not statistically significant ( P>0.05). During the 8.0 G for 10 s anti-G endurance test, there were significant differences in lower limb muscle contribution rates between the 3 groups ( F=4.19, P=0.029). The endurance endpoint group exhibited a lower contribution rate than the good vision and consciousness group ( P=0.025). During the 9.0 G for 10 s anti-G endurance test, there were significant differences in tibialis anterior muscle contribution rates between the 3 groups ( F=4.16, P=0.049). The endurance endpoint group demonstrated a lower contribution rate than the good vision and consciousness group ( P=0.049). Conclusions:The full and balanced activation of abdominal muscles and lower limb muscles, especially the effective mobilization of calf muscles, plays a pivotal role in improving pilots′ AGSM efficiency in high G environments.
2.Results of physiological experiments using a home-made high performance human centrifuge
Minghao YANG ; Lihui ZHANG ; Cong WANG ; Ke JIANG ; Haixia WANG ; Xiaoyang WEI ; Yi WANG ; Xiaoxue ZHANG ; Jie YU ; Zhao JIN
Chinese Journal of Aerospace Medicine 2025;36(3):182-187
Objective:To find out whether the performance of a China-made high performance human centrifuge can satisfy the need of high G training by conducting physiological experiments.Methods:The dynamic physical performance of the anti-G equipment with the human centrifuge was tested before 5 subjects underwent the gradual-onset rate (GOR) run and rapid onset rate (ROR) run experiments. The G onset rate of GOR was 0.1 G/s. The relaxed G-tolerance under GOR (GOR tolerance 1) and the anti-G straining maneuver aided G-tolerance under GOR (GOR tolerance 2) were tested respectively. The G onset rate of ROR was 3 G/s, and the closed-loop mode and pre-programed mode were employed respectively. The closed-loop mode involved 5 G 10 s and 8 G 10 s, where the subjects were required to manipulate the joystick to ensure that the real-time curve of the load matched the target curve. In the pre-programmed mode, the subjects were exposed to 8 G 10 s passively, without any operation requirements. A subjective evaluation form was filled out by subjects after the experiments, in which the 14 indexes for evaluation were about the gondola facilities and environment, running processes, medical monitoring and overall assessment.Results:Both the oxygen mask and anti-G suit achieved full pressurization within 2.0 s. The GOR tolerance 1 was [4.0(3.8, 4.6)] G while the GOR tolerance 2 was (6.2±0.5) G, suggesting a statistically significant difference ( Z=-2.63, P=0.008). The HP anti-G straining maneuver effect was (2.0±0.6) G. All the 5 subjects finished the 5 G 10 s experiment in a closed-loop mode. Three of them attempted 8 G 10 s in the closed-loop mode (1 subject achieved only 7.6 G peak acceleration, and the other 2 achieved full 8 G 10 s exposure), while the remaining 2 completed the 8 G 10 s in the pre-programmed mode. In the closed-loop mode, it was found that the stick force was too strong, the guiding G and real time G curve were not easy to distinguish for some of the subjects because the curve colors were similar, and that the subjects could not see the G curves clearly in case of a grayout. Both seat comfort and the voice quality of communication got the highest subjective assessment score [5.0(4.0, 5.0)] while the sensation of tumble got the lowest score (2.8±0.8). The median or mean scores of other subjective evaluation indexes ranged from 3.0 to 4.6 points. The overall score of subjective assessment was [4.0(3.5, 4.0)] points. Conclusions:The China-made high performance human centrifuge can meet the requirements of 8.0 G high G training, which can be made more effective and comfortable if the strong stick force and feeling of tumble during stop running are overcome.
3.Evaluation of left atrial strain and left atrioventricular global strain in patients with cardiovascular immune-related adverse events related to immune checkpoint inhibitors
Xin WANG ; Huiyu JIA ; Jiayu SU ; Lihui ZHAO ; Jie MU ; Wei FU ; Junguang WANG ; Xi WEI
Chinese Journal of Ultrasonography 2025;34(10):876-883
Objective:To evaluate the clinical utility of left atrial strain parameters and left atrioventricular global longitudinal strain(LAVGLS)in detecting cardiovascular immune-related adverse events(CV-irAEs)among non-small cell lung cancer patients receiving immune checkpoint inhibitors(ICIs).Methods:A total of 68 patients with non-small cell lung cancer were prospectively enrolled in Tianjin Medical University Cancer Institute and Hospital from October 2023 to October 2024. All patients were treated with ICIs for 6 cycles. Electrocardiogram,cardiac serological markers and echocardiography were examined before medication(T0 stage),4 cycles after medication(T1 stage)and 6 cycles after medication(T2 stage),respectively. According to the guidelines of the American Society of Clinical Oncology,all patients were divided into the CV-irAEs group( n=14)and the No-CV-irAEs group( n=54). AFI software and 4D Auto LAQ software were used to calculate LVGLS,left atrial reservoir longitudinal strain(LASr),LAVGLS and a series of left atrial parameters. Cox proportional hazards regression model was applied to find the risk factors for the occurrence of CV-irAEs. ROC curve was applied to analyze the diagnostic efficiency of these parameters for CV-irAEs. Results:Fourteen patients(20.6%)developed CV-irAEs after T2 stage. After ICIs treatment,LVGLS,LASr and LAVGLS decreased in both groups,LVGLS,LASr and LAVGLS decreased more significantly in the CV-irAEs group than those in the No-CV-irAEs group( P=0.038,0.047,0.005). Left ventricular ejection fraction(LVEF)decreased in the CV-irAEs group at the same time( P=0.003). Cox multivariate analysis showed that ΔLAVGLS(the difference between stage T0 and stage T2)was a risk factor for CV-irAEs( HR:1.395, P=0.019). ROC curve analysis showed the area under the curve of LVGLS,LASr,LAVGLS,ΔLVGLS,ΔLASr,ΔLAVGLS,and LVEF at the T2 stage for diagnosis of CV-irAEs were 0.68,0.67,0.75,0.79,0.73,0.82,and 0.72,respectively. Conclusions:Decline of LAVGLS is a risk factor for CV-irAEs in patients with non-small cell lung cancer receiving ICIs and can be used for early detection of CV-irAEs. LASr has potential diagnostic value for CV-irAEs,but it is less valuable than LVGLS and LAVGLS.
4.Screening and validation of chemoresistance marker in lung adenocarcinoma based on gene expression profile
Handong Wei ; Shuxing Chen ; Linting Liu ; Zihan Jing ; Yiting Yang ; Qiong Song ; Wenchu Wang ; Chunlin Zou ; Lihui Wang
Acta Universitatis Medicinalis Anhui 2025;60(10):1818-1827
Objective:
To discover molecular markers associated with lung adenocarcinoma diagnosis/prognosis and drug resistance through screening of differentially expressed genes based on published chip data in gene expression databases using bioinformatics methods.
Methods:
Comprehensive analysis was performed in available mRNA microarray datasets including lung adenocarcinoma tissues dataset GSE32863 and lung adenocarcinoma taxane-platin resistance dataset GSE77209 from the gene expression omnibus(GEO) database. Gene ontology enrichment analysis, gene pathway enrichment analysis and protein interaction network analysis were performed based on significantly correlated genes. The expression level of genes was validated in the cancer genome atlas(TCGA) dataset. Survival differences were assessed by the log-rank test in TCGA lung adenocarcinoma dataset. Based on the publications genomics of drug sensitivity in cancer(GDSC) database in CellMiner cross database(CellMiner CDB), Pearson correlation analysis was used to analyze the correlation between differentially expressed genes and the half-maximal inhibitory concentration(IC50) of anticancer drugs.
Results :
There were a total of 77 genes which had a different expression in resistance lung adenocarcinoma cells and lung adenocarcinoma cancer tissues. The functional enrichment analysis showed that these co-different expression genes were mainly enriched in microtubule, extracellular exosome, cell cycle and signaling by nuclear receptors. Protein-protein interactions(PPI) network screened 6 most connected genes as molecular complex(MCODE). Among the MCODE, overexpressed ubiquitin conjugating enzyme E2 T(UBE2T), kinesin family member 20A(KIF20A), PCNA clamp associated factor(KIAA0101), pituitary tumor-transforming gene 1(PTTG1) and NIMA related kinase 2(NEK2) were associated with poor outcomes. Survival analysis results showed that these five genes were upregulated in lung adenocarcinoma tissues and drug-resistant cells and were significantly associated with poor prognosis in lung adenocarcinoma patients. Drug sensitivity analysis results suggested that high expression of PTTG1 and UBE2T was significantly associated with sensitivity to multiple anticancer drugs, including paclitaxel and docetaxel. RT-PCR validation showed that PTTG1 andUBE2T were highly expressed in docetaxel-resistant cells A549-TXR and H358-TXR.
Conclusion
PTTG1 andUBE2T holds the potential to be chemoresistance markers in lung adenocarcinoma.
5.Analysis of hearing screening results for newborns with failed genetic screening of 23-cite chip
Yu RUAN ; Cheng WEN ; Xiaohua CHENG ; Wei ZHANG ; Jinge XIE ; Yue LI ; Lin DENG ; Shan GAO ; Lihui HUANG
Chinese Archives of Otolaryngology-Head and Neck Surgery 2025;32(4):215-220
OBJECTIVE To investigate the relationship between 23-site chip genetic screening failures and the results of newborns hearing screening,and to provide clinical reference for the diagnosis and treatment of genetic screening failures.METHODS There were 1 916 newborns born in the Beijing area from November 2022 to May 2024,who did not pass the 23-site chip genetic screening tests and underwent newborn hearing screening with definite initial screening results.Chi-square test was used to analyze the relationship between different mutation types and genotypes and the initial hearing screening results.RESULTS The overall neonatal hearing screening failure rate was 5.27%(101/1 916),with a higher failure rate of 61.54%(56/91)for homozygous and compound heterozygous mutations than the failure rate of 2.54%(45/1 772)for heterozygous mutations,0%(0/34)for digenic gene heterozygous mutations,and 0(0/19)for mtDNA 12S rRNA mutations,with a statistically significant difference(P<0.001).Among the homozygous and compound heterozygous mutations,the failure rates of homozygous and compound heterozygous for GJB2 gene and SLC26A4 gene were 59.76%(49/82)and 77.78%(7/9),respectively,with no statistically significant difference between the two groups(P=0.488).The homozygous and compound heterozygous for GJB2 gene were divided into three groups based on genotype:c.109G>A homozygous mutations,c.109G>A compound heterozygous mutations,and other homozygous and compound heterozygous mutations.The hearing screening failure rates of the three groups,from highest to lowest,were as follow:other homozygous and compound heterozygous mutations(88.89%,8/9),c.109G>A homozygous mutations(65.12%,28/43),and c.109G>A compound heterozygous mutations(43.33%,13/30),with a statistically significant difference(P=0.029).The failure rates of heterozygous for GJB2 gene,SLC26A4 gene and GJB3 gene were 2.86%(40/1 398),1.25%(4/321)and 1.89%(1/53),respectively,with no statistically significant difference among the three groups(P=0.241).The failure rate of hearing screening for individuals with GJB2 heterozygotes of different genotypes and individuals with SLC26A4 heterozygotes of different genotypes did not show statistically significant differences.CONCLUSION The failure rate of newborn hearing screening for homozygous and compound heterozygous mutation of 23-site chip genetic screening is higher than that of other mutation types,verifying the effectiveness of the newborn hearing screening program.Some newborns of homozygous and compound heterozygous mutation can pass the hearing screening,especially those with the c.109G>A homozygous and compound heterozygous mutation,who need clinical follow-up.
6.Evaluation of the efficacy and safety of cryopreserved deglycerolized red blood cells infusion based on propensity score matching method
Wei YANG ; Fanfan FU ; Lei NIU ; Tingchen XU ; Xin ZHANG ; Hongmei SHI ; Lihui FU ; Chunya MA ; Yang YU
Chinese Journal of Blood Transfusion 2025;38(4):531-536
[Objective] To compare the efficacy and safety of deglycerolized red blood cells (DRBC) and suspended red blood cells (SRBC) based on the propensity score matching (PSM) method, so as to provide evidence for the rational use of DRBC resources in clinical practice. [Methods] A total of 89 patients who received DRBC transfusion and 2 916 patients who received SRBC transfusion in our hospital from January 2023 to September 2024 were included. A 1∶1 nearest neighbor PSM was used to balance covariates such as gender, age, and body mass index (BMI). The changes of hemoglobin (Hb), red blood cell (RBC) count, hematocrit (HCT), and inflammatory markers such as white blood cell (WBC) count, neutrophil (NE) count, C-reactive protein (CRP), and Interleukin-6(IL-6) in the last 72 hours after transfusion were analyzed by SPSS 26.0 and R software to evaluate clinical efficacy and transfusion safety. [Results] The baseline of the two groups was balanced after PSM (P>0.05). There was no significant difference in the total effective rate between the DRBC group (80.9%) and the SRBC group (86.5%) (P>0.05). In the SRBC group, WBC (×10
/L) increased from 9.634±6.742 to 10.147±6.835, CRP (mg/dL) increased from 5.468±4.647 to 6.174±6.114, and IL-6(pg/mL) decreased from 213.733±587.191 to 157.255±552.626. In the DRBC group, WBC (×10
/L) decreased from 11.123±7.880 to 11.011±8.549, CRP (mg/dL) decreased from 5.729±4.761 to 5.326±4.466, and IL-6(pg/mL) decreased from 238.806±639.060 to 152.255±266.558. Compared with the before treatment, the differences between the SRBC group and DRBC group were not statistically significant (P>0.05). Among all patients included in the statistics, the overall incidence of transfusion adverse reactions was 0.205% (6/2 916) in the SRBC group, and no adverse reactions occurred in the DRBC group. The incidence in the SRBC group was higher than that in the DRBC group. [Conclusion] Based on PSM analysis, there was no significant difference in the efficacy and safety of DRBC transfusion compared with SRBC transfusion, which can provide evidence-based support for routine application.
7.Study of diagnostic value of circRNA9226 combined with tumor markers in lung adenocarcinoma
Wei ZHOU ; Yangcong QI ; Zhangsheng ZHAO ; Lihui QIAN ; Youli MA ; Yinyu MU
China Modern Doctor 2025;63(17):16-19
Objective To investigate the value of peripheral blood circRNA9226 combined with tumor markers for the diagnosis of lung adenocarcinoma.Methods A total of 30 patients with lung adenocarcinoma who were admitted to the Affiliated Lihuili Hospital of Ningbo University from December 2022 to January 2023 were selected as case group.Additionally,twenty healthy individuals who underwent physical examinations during the same period were selected as control group.The expression levels of circRNA9226,carcinoembryonic antigen(CEA),carbohydrate antigen(CA)199,and albumin(Alb)were compared between two groups.The diagnostic efficacy of circRNA9226 and CEA for lung adenocarcinoma was evaluated by receiver operating characteristic(ROC)curve,and the correlation between circRNA9226 and other indicators was analyzed.Results The peripheral blood circRNA9226 expression levels in case group was higher than that in control group(P<0.05).The sensitivity of circRNA9226 and CEA for diagnosing lung adenocarcinoma was 83.3%and 46.7%,respectively,with specificity of 90.0%and 100.0%.Area under the curve(AUC)was 0.897 and 0.776,respectively.When both tests were combined,the sensitivity was 93.3%,accuracy was 92.0%,and AUC was 0.918,showing a significant improvement in both sensitivity and accuracy compared to single tests.The correlation analysis results showed that circRNA9226 was positively correlated with CEA concentration(r=0.371,P<0.05)and negatively correlated with Alb concentration(r=-0.548,P<0.05).Conclusion Peripheral blood circRNA9226 has advantages in distinguishing lung adenocarcinoma from healthy controls,and combined with CEA can further improve the diagnostic efficacy.
8.Evaluation of left atrial strain and left atrioventricular global strain in patients with cardiovascular immune-related adverse events related to immune checkpoint inhibitors
Xin WANG ; Huiyu JIA ; Jiayu SU ; Lihui ZHAO ; Jie MU ; Wei FU ; Junguang WANG ; Xi WEI
Chinese Journal of Ultrasonography 2025;34(10):876-883
Objective:To evaluate the clinical utility of left atrial strain parameters and left atrioventricular global longitudinal strain(LAVGLS)in detecting cardiovascular immune-related adverse events(CV-irAEs)among non-small cell lung cancer patients receiving immune checkpoint inhibitors(ICIs).Methods:A total of 68 patients with non-small cell lung cancer were prospectively enrolled in Tianjin Medical University Cancer Institute and Hospital from October 2023 to October 2024. All patients were treated with ICIs for 6 cycles. Electrocardiogram,cardiac serological markers and echocardiography were examined before medication(T0 stage),4 cycles after medication(T1 stage)and 6 cycles after medication(T2 stage),respectively. According to the guidelines of the American Society of Clinical Oncology,all patients were divided into the CV-irAEs group( n=14)and the No-CV-irAEs group( n=54). AFI software and 4D Auto LAQ software were used to calculate LVGLS,left atrial reservoir longitudinal strain(LASr),LAVGLS and a series of left atrial parameters. Cox proportional hazards regression model was applied to find the risk factors for the occurrence of CV-irAEs. ROC curve was applied to analyze the diagnostic efficiency of these parameters for CV-irAEs. Results:Fourteen patients(20.6%)developed CV-irAEs after T2 stage. After ICIs treatment,LVGLS,LASr and LAVGLS decreased in both groups,LVGLS,LASr and LAVGLS decreased more significantly in the CV-irAEs group than those in the No-CV-irAEs group( P=0.038,0.047,0.005). Left ventricular ejection fraction(LVEF)decreased in the CV-irAEs group at the same time( P=0.003). Cox multivariate analysis showed that ΔLAVGLS(the difference between stage T0 and stage T2)was a risk factor for CV-irAEs( HR:1.395, P=0.019). ROC curve analysis showed the area under the curve of LVGLS,LASr,LAVGLS,ΔLVGLS,ΔLASr,ΔLAVGLS,and LVEF at the T2 stage for diagnosis of CV-irAEs were 0.68,0.67,0.75,0.79,0.73,0.82,and 0.72,respectively. Conclusions:Decline of LAVGLS is a risk factor for CV-irAEs in patients with non-small cell lung cancer receiving ICIs and can be used for early detection of CV-irAEs. LASr has potential diagnostic value for CV-irAEs,but it is less valuable than LVGLS and LAVGLS.
9.Surface electromyogram assessment of effectiveness of anti-G straining maneuver of high performance fighter pilots
Jinghui YANG ; Baohui LI ; Yan XU ; Haixia WANG ; Zhao JIN ; Xichen GENG ; Hong WANG ; Xiaoyang WEI ; Ke JIANG ; Yifeng LI ; Lihui ZHANG ; Xiaoxue ZHANG ; Minghao YANG
Chinese Journal of Aerospace Medicine 2025;36(2):113-118
Objective:To evaluate the effectiveness of anti-G straining maneuver (AGSM) in pilots by surface electromyography (sEMG), and to explore the relationships between characteristics of sEMG and anti-G endurance in pilots.Methods:Thirty-eight male high-performance fighter pilots who completed the human centrifuge test at the Air Force Medical Center were selected. Among them, 25 completed the 8.0 G for 10 s anti-G endurance test and 13 completed the 9.0 G for 10 s anti-G endurance test. The sEMG tester was used to keep track of the changes of sEMG in rectus abdominis, rectus femoris, anterior tibial and gastrocnemius muscles while pilots were engaged in AGSM. The anti-G endurance was evaluated according to the changes of visual fields and consciousness. The pilots were divided into 3 groups: the good vision and consciousness group, peripheral visual field narrowing group and endurance endpoint group. The differences in the integral electromyogram (iEMG), mean power frequency (MPF) and muscle input rates between the 3 groups were investigated.Results:A total of 25 pilots completed the 8.0 G for 10 s anti-G endurance test. Among them, 8 (32.0%) were in the good vision and consciousness group, 13 (52.0%) in the peripheral visual field narrowing group and 4 (16.0%) reached the endurance endpoint. Among the 13 pilots who completed the 9.0 G for 10 s anti-G endurance test, 3 (23.1%) were in the good vision and consciousness group, 6 (46.1%) in the peripheral visual field narrowing group, and 4 (30.8%) in the endurance endpoint group. The results of sEMG showed that the iEMG values of the anterior tibialis muscle in pilots under the 9.0 G for 10 s load were significantly different across endurance groups ( H=7.54, P=0.023), and that the iEMG values of the tibialis anterior muscle in the good vision and consciousness group were higher than those in the endurance endpoint group ( P=0.036). The negative slopes of MPF for the rectus abdominis, rectus femoris, anterior tibialis, and gastrocnemius muscles were higher in the good vision and consciousness group than in the other 2 groups, but the differences were not statistically significant ( P>0.05). During the 8.0 G for 10 s anti-G endurance test, there were significant differences in lower limb muscle contribution rates between the 3 groups ( F=4.19, P=0.029). The endurance endpoint group exhibited a lower contribution rate than the good vision and consciousness group ( P=0.025). During the 9.0 G for 10 s anti-G endurance test, there were significant differences in tibialis anterior muscle contribution rates between the 3 groups ( F=4.16, P=0.049). The endurance endpoint group demonstrated a lower contribution rate than the good vision and consciousness group ( P=0.049). Conclusions:The full and balanced activation of abdominal muscles and lower limb muscles, especially the effective mobilization of calf muscles, plays a pivotal role in improving pilots′ AGSM efficiency in high G environments.
10.Results of physiological experiments using a home-made high performance human centrifuge
Minghao YANG ; Lihui ZHANG ; Cong WANG ; Ke JIANG ; Haixia WANG ; Xiaoyang WEI ; Yi WANG ; Xiaoxue ZHANG ; Jie YU ; Zhao JIN
Chinese Journal of Aerospace Medicine 2025;36(3):182-187
Objective:To find out whether the performance of a China-made high performance human centrifuge can satisfy the need of high G training by conducting physiological experiments.Methods:The dynamic physical performance of the anti-G equipment with the human centrifuge was tested before 5 subjects underwent the gradual-onset rate (GOR) run and rapid onset rate (ROR) run experiments. The G onset rate of GOR was 0.1 G/s. The relaxed G-tolerance under GOR (GOR tolerance 1) and the anti-G straining maneuver aided G-tolerance under GOR (GOR tolerance 2) were tested respectively. The G onset rate of ROR was 3 G/s, and the closed-loop mode and pre-programed mode were employed respectively. The closed-loop mode involved 5 G 10 s and 8 G 10 s, where the subjects were required to manipulate the joystick to ensure that the real-time curve of the load matched the target curve. In the pre-programmed mode, the subjects were exposed to 8 G 10 s passively, without any operation requirements. A subjective evaluation form was filled out by subjects after the experiments, in which the 14 indexes for evaluation were about the gondola facilities and environment, running processes, medical monitoring and overall assessment.Results:Both the oxygen mask and anti-G suit achieved full pressurization within 2.0 s. The GOR tolerance 1 was [4.0(3.8, 4.6)] G while the GOR tolerance 2 was (6.2±0.5) G, suggesting a statistically significant difference ( Z=-2.63, P=0.008). The HP anti-G straining maneuver effect was (2.0±0.6) G. All the 5 subjects finished the 5 G 10 s experiment in a closed-loop mode. Three of them attempted 8 G 10 s in the closed-loop mode (1 subject achieved only 7.6 G peak acceleration, and the other 2 achieved full 8 G 10 s exposure), while the remaining 2 completed the 8 G 10 s in the pre-programmed mode. In the closed-loop mode, it was found that the stick force was too strong, the guiding G and real time G curve were not easy to distinguish for some of the subjects because the curve colors were similar, and that the subjects could not see the G curves clearly in case of a grayout. Both seat comfort and the voice quality of communication got the highest subjective assessment score [5.0(4.0, 5.0)] while the sensation of tumble got the lowest score (2.8±0.8). The median or mean scores of other subjective evaluation indexes ranged from 3.0 to 4.6 points. The overall score of subjective assessment was [4.0(3.5, 4.0)] points. Conclusions:The China-made high performance human centrifuge can meet the requirements of 8.0 G high G training, which can be made more effective and comfortable if the strong stick force and feeling of tumble during stop running are overcome.


Result Analysis
Print
Save
E-mail