1.A comparative study on the conversion treatment of the sirolimus quadruple regimen for expanded criteria donor kidney transplantation versus the control group from the same donors
Hua YANG ; Rui XIONG ; Lisong WAN ; Tongzhang CHEN ; Jinran YANG ; Wenfeng LUO ; Xinzhang LI
Organ Transplantation 2026;17(2):243-249
Objective To explore the efficacy and safety of converting the triple immunosuppressive regimen of tacrolimus (Tac) + mycophenolate mofetil (MMF) + prednisone (Pred) to a quadruple regimen of low-dose sirolimus (SRL) + low-dose Tac + MMF + Pred at 3 to 6 months after expanded criteria donor (ECD) kidney transplantation. Methods A single-center, retrospective, donor-matched controlled study included 22 ECD kidney transplant recipients from September 2021 to June 2024. Two recipients from the same donor kidneys were respectively assigned to the SRL group and the conventional triple regimen control group. The main outcome measures were the differences in serum creatinine (Scr), estimated glomerular filtration rate (eGFR), and adverse events before the regimen conversion and after conversion during the 1, 3, 6, and 12-month follow-up. Results There were no statistically significant differences in baseline characteristics between the two groups. In the SRL group, Scr decreased and eGFR increased starting from 3 months after conversion, and this was superior to the control group starting from 6 months(all P < 0.05). There were no statistically significant differences in the incidence of rejection reactions, pulmonary infections, hyperlipidemia and proteinuria between the two groups after conversion and during the 12-month follow-up (all P > 0.05). Conclusions For ECD kidney transplant recipients, converting the triple regimen to the SRL quadruple regimen at 3 to 6 months after transplantation may improve the function of the transplanted kidney without increasing the risk of adverse events.
2.Expert recommendations on vision friendly built environments for myopia prevention and control in children and adolescents
Chinese Journal of School Health 2026;47(1):1-5
Abstract
The prevention and control of myopia in Chinese children and adolescents has become a major public health issue. While maintaining increased outdoor activity as a cornerstone intervention, there is an urgent need to explore new complementary approaches that can be effectively implemented in both indoor and outdoor settings. In recent years, environmental spatial frequency has gained increasing attention as one of the key environmental factors influencing the development and progression of myopia. Both animal studies and human research have confirmed that indoor environments lacking mid to high spatial frequency components, often characterized as "visually impoverished", can promote axial elongation and myopia through mechanisms such as disruption of retinal neural signaling, impaired accommodative function, and altered expression of related molecules. Based on the scientific consensus, it is recommended that "enriching of environmental spatial frequency" should be integrated into the myopia prevention and control framework. Following the principles of schoolled organization, family cooperation, community involvement, and student participation, specific measures are put forward in three areas:optimizing school visual settings, improving home spatial environments, and promoting healthy visual behavior. The aim is to create "visually friendly" indoor environments as an important supplement to outdoor activity, thereby providing a novel perspective and strategy for comprehensively advancing myopia prevention and control among children and adolescents.
3.Resolution Assessment in Super-resolution Optical Microscopy: Adaptive Methods and Recent Advances
San-Hua FANG ; Jing-Yao CHEN ; Dan YANG ; Li LIU
Progress in Biochemistry and Biophysics 2026;53(4):805-825
Optical microscopy is essential for exploring biological and material structures, with resolution determining the level of observable detail. The advent of super-resolution fluorescence microscopy has broken the diffraction limit, achieving nanoscale resolution. However, traditional assessment methods, such as the Rayleigh criterion and point spread function (PSF) width measurement, rely on empirical judgments and diffraction-limited models, rendering them inadequate for modern super-resolution imaging. This review systematically traces the evolution of resolution assessment methodologies, from classical criteria to advanced strategies tailored for various super-resolution modalities. We first discuss Fourier-based quantitative methods. Fourier ring correlation (FRC) and its 3D counterpart, Fourier shell correlation (FSC), objectively determine resolution by evaluating the statistical correlation of two independent image reconstructions in frequency space. These methods offer robustness against noise and provide a global resolution metric, but they require data independence and are computationally intensive. They have become the prevailing standards in electron and super-resolution microscopy. Subsequently, we examine adaptations for specific super-resolution techniques. For single-molecule localization microscopy (SMLM) techniques such as PALM and STORM, the Fourier image resolution (FIRE) method extends FRC by incorporating a physical model that accounts for localization precision and labeling density. For stimulated emission depletion (STED) microscopy and other nonlinear techniques, assessment strategies differ. While PSF shrinkage measurements using fluorescent beads are useful for system calibration, evaluating the effective resolution directly on biological samples is more practical. This is typically performed via linewidth analysis of known structures (e.g., microtubules) or edge-spread function measurements, capturing the effects of photobleaching and sample-induced aberrations. A major paradigm shift is parameter-free resolution estimation based on decorrelation analysis. This method analyzes the autocorrelation decay of a single image’s Fourier spectrum to identify the cutoff spatial frequency without requiring dual datasets or user-defined thresholds. Its high efficiency and broad applicability have been validated across widefield, confocal, STED, SIM, and SMLM modalities. Optimized rendering strategies for SMLM data further enhance its accuracy, and it is emerging as a tool for real-time optimization of experimental parameters. The review also addresses the “gold standard” of resolution validation using well-defined nanostructures, such as DNA origami and nuclear pore complexes, which provide ground truth for verifying resolution claims and detecting artifacts. In the era of artificial intelligence, deep learning plays a dual role: it powerfully enhances image resolution but also introduces challenges, as models may generate “hallucinations” or false details. This underscores the need for new validation metrics to verify the physical fidelity of AI-generated content. Finally, we outline future directions: developing unified cross-modality standards, enabling real-time dynamic resolution monitoring for live-cell imaging, creating techniques for generating local resolution maps to capture sample heterogeneity, and integrating intelligent error correction to ensure data veracity. By providing a comprehensive overview of resolution assessment progress and challenges, this review aims to equip researchers with the knowledge to select appropriate tools, thereby fostering rigorous quantitative imaging in the life and material sciences.
4.Comparative Analysis of Clinical Efficacy of Traditional Chinese Medicine Manipulative Reduction Combined with Small Splint Fixation Versus Surgical Treatment for Type A Distal Radius Fracture
Yang SHAO ; Zihan WANG ; Jianwei WANG ; Guoda DAI ; Hengyan CUI ; Zhen HUA ; Tingchen ZHU ; Shaoshuo LI ; Jun MAO ; Fenghua CHEN ; Shuai TAO ; Mao WU
Journal of Traditional Chinese Medicine 2026;67(10):1078-1085
ObjectiveTo compare the clinical efficacy of traditional Chinese medicine (TCM) manipulative reduction combined with small splint fixation versus surgical treatment for type A distal radius fracture (DRF) and to explore the factors influencing the choice of treatment. MethodsA multi-center retrospective study was conducted, collecting data from 1237 type A DRF patients treated in 11 hospitals in Jiangsu province from September, 2023 to April, 2025. Among them, 851 patients in the TCM group received manipulative reduction combined with small splint fixation, and 386 patients in the surgical group underwent open reduction and internal fixation. Visual analog scale (VAS) scores for pain and radiographic indicators including palmar tilt, ulnar deviation, and radial height were compared before treatment, 5-7 days after treatment, and 4-6 weeks after treatment. The wrist joint function scores including Dienst and Gartland-Werley scores at 12 weeks after treatment were recorded. Subgroup analysis was conducted for the excellent rate of Dienst and Gartland-Werley scores, stratified by age (<50, 50-59, 60-69, ≥70 years old) and AO subtypes (A1, A2, A3). A multivariate logistic regression model was used to identify independent factors influencing treatment choice. ResultsOn 5-7 days after treatment, the surgical group had lower VAS scores than the TCM group, while 4-6 weeks after treatment, the TCM group showed lower VAS scores than the surgical group (P<0.01). In terms of radiographic indicators, except for the palmar tilt before treatment being higher in the surgical group than in the TCM group (P<0.01), there were no significant differences in palmar tilt, ulnar deviation, and radial height at other timepoints (P>0.05). Twelve weeks after treatment, the surgical group had a higher average Gartland-Werley score and the excellent rate than the TCM group (P<0.01). Subgroup analysis showed that in patients with A2 type DRF aged 50-59 and 60-69 years old, the excellent rates of Dienst and Gartland-Werley scores in the TCM group were higher than those in the surgical group (P<0.05). Multivariate logistic regression analysis revealed that age, palmar tilt, ulnar deviation, and the degree of swelling on the affected side were independent factors influencing the choice of treatment (P<0.05). ConclusionBoth TCM manipulative reduction combined with small splint fixation and surgical treatment for type A DRF can achieve good therapeutic effects. TCM manipulative reduction combined with small splint fixation has certain advantages in medium- and long-term pain relief, especially in elderly patients, where wrist joint function recovery is more stable. Age, palmar tilt, ulnar deviation, and swelling degree are the main factors influencing the treatment choice.
5.Clinical Efficacy and Radiographic Outcomes of Manipulative Reduction Combined with Small Splint Fixation for Distal Radius Fractures:A Retrospective Multicenter Study with Propensity Score Matching
Mao WU ; Guoda DAI ; Yang SHAO ; Shaoshuo LI ; Zhen HUA ; Hengyan CUI ; Tingchen ZHU ; Dipeng LI ; Jintao LIU ; Ming ZHOU ; Peimin WANG ; Liyong ZHANG ; Jianwei WANG
Journal of Traditional Chinese Medicine 2026;67(10):1086-1092
ObjectiveTo observe the clinical efficacy and radiographic outcomes of manipulative reduction combined with small splint fixation in the treatment of distal radius fractures. MethodsThe clinical data of 1051 patients with distal radius fractures were retrospectively collected from five hospitals included in the Jiangsu Diagnosis and Treatment Data Platform for Traditional Chinese Medicine(TCM) Dominant Diseases. Propensity score matching at a 1∶4 ratio was applied, resulting in 580 cases selected for final analysis, which comprised 448 patients in the TCM group(manipulative reduction plus small splint fixation) and 132 in the surgical treatment group(open reduction and internal fixation). Each group was further stratified into type A, B, and C subgroups based on AO fracture classification. Radiographic indicators including palmar tilt, radial inclination, and radial height were compared between groups before treatment and 1 day, 1 week, and 4-6 weeks after treatment, and pain visual analog scale(VAS) scores before treatment and 1 week and 4-6 weeks after treatment were also compared. Wrist joint function was assessed 12 weeks after treatment, using the Dienst wrist function score and the Gartland and Werley(G-W) wrist function score. Additionally, the radiographic indicators at different timepoints and the 12-week wrist function levels were compared between groups across different fracture types. ResultsNo statistically significant difference was observed in radiographic indicators and VAS scores at all timepoints before and after treatment, as well as wrist joint function grades assessed by the Dienst score and the G-W score at 12 weeks after treatment (P>0.05). Compared to those before treatment, both groups showed increased palmar tilt, radial inclination, and radial height 1 week and 4-6 weeks after treatment, and decreased VAS scores (P<0.05). Compared to those 1 week after treatment, both groups showed a decrease in palmar tilt, an increase in radial inclination and radial height, and a reduction in VAS score 4-6 weeks after treatment(P<0.05). In type A and B subgroups, the surgical treatment group had a higher radial inclination than the TCM group 4-6 weeks after treatment, while in the type C subgroup, a higher radial height was shown in the surgical treatment group than in the TCM group 4-6 weeks after treatment(P<0.05). In type C subgroup, there was significant difference between groups in the wrist joint function by G-W scores 12 weeks after treatment(P<0.05). ConclusionManipulative reduction combined with small splint fixation can maintain fracture alignment and alleviate pain in treating distal radius fractures, which achieves therapeutic outcomes comparable to surgical treatment. It is particularly suitable for type A and B fractures and can be considered an effective treatment option for distal radius fractures.
6.Construction and Clinical Validation of a Deep Learning-Based Automatic Measurement Model for Palmar Tilt and Radial Inclination in Distal Radius Fractures
Guoda DAI ; Jianwei WANG ; Mao WU ; Bin KANG ; Yang SHAO ; Hengyan CUI ; Shaoshuo LI ; Tingchen ZHU ; Zhen HUA ; Zhongming SHEN ; Jintao LIU ; Ming ZHOU
Journal of Traditional Chinese Medicine 2026;67(10):1093-1100
ObjectiveTo construct an automatic measurement model for palmar tilt and radial inclination suitable for traditional Chinese medicine (TCM) clinical scenarios, and to validate its accuracy and efficiency in TCM manipulative reduction settings. MethodsData on anteroposterior (AP) and lateral X-rays of distal radius fractures were collected from patients admitted to 18 TCM/ integrated TCM and western medicine hospitals in Jiangsu province between September 1st, 2023, and September 1st, 2024, via the Jiangsu Diagnosis and Treatment Big Data Platform for TCM Dominant Diseases. A medical image segmentation framework based on multi-scale feature fusion and edge-awareness was employed, combined with anatomical knowledge specific to TCM orthopedics, to optimize the feature extraction strategy of an artificial intelligence (AI) model. This framework enabled automatic segmentation of fracture regions and measurement of distal radius palmar tilt and radial inclination. The accuracy of the AI model in measuring radial inclination and volar tilt was validated, and the measurement time and average time gain rate of the AI model were compared to those of manual measurement. ResultsA total of 15,444 AP and lateral X-ray images of distal radius fractures were collected, and were divided into a training set (11,144 images, 5066 AP and 6078 lateral), a validation set (3700 images, 1840 AP and 1860 lateral), and an independent test set (600 images, 300 AP and 300 lateral) after preprocessing. In the measurement of 300 AP X-rays in the independent test set for radial inclination, when the degree error between AI measurement and manual measurement was <3° and <5°, AI measurement accuracy was 83% and 93%, respectively. In 300 lateral X-rays in the test set for palmar tilt, when AI measurements had an error of <3° and <5° compared to manual measurements, corresponding accuracy rate was 78% and 90%, respectively. For 50 X-ray images, AI measurement time was (1.37±0.05) min for radial inclination while manual measurement time was (22.57±2.52) min (P<0.001); in terms of palmar tilt, the AI measurement time was (1.33±0.14) min, shorter than (23.70±2.80) min for manual measurement time (P<0.001). Average time gain rates for manual and AI measurements were 93.93% and 94.39% respectively. ConclusionAn automatic measurement model for palmar tilt and radial inclination in distal radius fractures has been established, enabling more accurate and efficient assessment as well as providing a tool to support the quantitative evaluation of the efficacy of TCM manipulative reduction and large-sample clinical research.
7.Assessment of ochratoxin A exposure in the diets of pregnant women in Shanghai
Kailin LI ; Renjie QI ; Hua CAI ; Xia SONG ; Jingjin YANG ; Danping QIU ; Zhenni ZHU ; Yi HE ; Baozhang LUO ; Hong LIU
Shanghai Journal of Preventive Medicine 2026;38(3):181-186
ObjectiveTo investigate the contamination status of ochratoxin A (OTA) in commercially available food products in Shanghai, and to assess OTA exposure levels and the associated non-carcinogenic and carcinogenic risks among pregnant women by integrating dietary consumption data of this population. MethodsThe levels of OTA contamination in 1 520 food samples collected in Shanghai from 2022 to 2023 were determined using liquid chromatography-tandem mass spectrometry. An exposure assessment model was developed based on the dietary consumption levels of pregnant women from the 2016‒2017 Shanghai Pregnant Women Dietary Monitoring Survey to calculate the estimated daily intake (EDI) of OTA, the margin of exposure for non-carcinogenic toxicity (MOE1), and the margin of exposure for carcinogenic toxicity (MOE2). An MOE1 greater than 200 and an MOE2 greater than 10 000 indicate that the non-carcinogenic toxicity and carcinogenic toxicity resulting from exposure are negligible, respectively. For samples with OTA contamination levels below the limit of detection (LOD), which accounted for more than 80% of the samples, the OTA levels were assigned values of 0 and LOD, respectively, for subsequent calculations. ResultsThe detection rates of OTA in cereals, nuts, dried fruits, and alcohol samples collected in 2022 were 2.03%, 0, 0, and 0, respectively. The OTA detection rates in cereals, nuts, dried fruits, beans, and alcohol samples collected in 2023 were 2.50%, 0.39%, 2.47%, 1.67%, and 13.33%, respectively. For pregnant women in Shanghai in 2022, simulation results indicated that when assigning a value of 0 and the LOD, theP50 values of EDI for dietary OTA exposure were 0.05 and 0.72 ng·(kg·d)-1, respectively, and the P95 values of EDI for dietary OTA exposure were 0.25 and 2.40 ng·(kg·d)-1, respectively. For pregnant women in Shanghai in 2023, the P50 values of EDI for dietary OTA exposure were 0.04 and 1.00 ng·(kg·d)-1, respectively, and the P95 values of EDI for dietary OTA exposure were 0.23 and 2.67 ng·(kg·d)-1, respectively, both substantially below the tolerable daily intake (TDI) for OTA [17 ng·(kg·d)-1]. The EDI for dietary OTA exposure in 100.0% of Shanghai pregnant women was lower than the TDI, indicating an overall low level of dietary OTA exposure among this population. For 100.0% of pregnant women, the MOE₁ for dietary OTA exposure exceeded 200. When assigned a value of 0, the MOE₂ for 100.0% of pregnant women in both 2022 and 2023 exceeded10 000. When assigned the LOD value, 72.3% and 81.8% of pregnant women in 2022 and 2023, respectively, had an MOE₂ exceeding 10 000. ConclusionFrom 2022 to 2023, samples of cereals, nuts, dried fruits, beans, and alcohol sold in Shanghai exhibited varying degrees of OTA contamination. The overall EDI of OTA exposure among pregnant women in Shanghai remained at a low level. The non-carcinogenic and carcinogenic risks associated with OTA exposure were generally low and at controllable levels.
8.PET/CT imaging of PD-1 receptor probe targeting S180 sarcoma in mice
Haifeng HUANG ; Jiangnan SUN ; Huan ZOU ; Tao BAO ; Hua ZHU ; Xianteng YANG ; Shanshan LI
Acta Universitatis Medicinalis Anhui 2026;61(4):682-688
ObjectiveTo explore the feasibility of constructing a programmed death receptor-1(PD-1) molecular probe for non-invasive micro-positron emission tomography/computed tomography (Micro-PET/CT) imaging of PD-1 protein in mouse S180 sarcoma. MethodsA transgenic PD-1 C57 S180 sarcoma mouse model was established using the S180 sarcoma cell injection. Furthermore, 124I-anti-PD-1 monoclonal antibody probe was synthesized. 18.5 MBq of the 124I-anti-PD-1 probe was injected into the tail vein of transgenic PD-1 C57 mice. Subsequently, S180 sarcoma was imaged using Micro-PET/CT. ResultsStudy successfully established a transgenic PD-1 C57 S180 sarcoma mouse model. Immunohistochemical (IHC) results showed PD-1 protein expression in S180 sarcoma. Micro-PET/CT imaging successfully visualized the PD-1 protein receptor in S180 sarcoma at different time points (20, 48, 72, and 120 h) after probe injection. ConclusionThe 124I-anti-PD-1 monoclonal antibody molecular probe successfully targets the PD-1 receptor in S180 sarcoma of transgenic PD-1 C57 mice, and presents clear Micro-PET/CT immunoassay results, thus it potentially enables the non-invasive screening of patients with PD-1 positive malignant tumors.
9.Effects of Exercise Training on The Behaviors and HPA Axis in Autism Spectrum Disorder Rats Through The Gut Microbiota
Xue-Mei CHEN ; Yin-Hua LI ; Jiu-Gen ZHONG ; Zhao-Ming YANG ; Xiao-Hui HOU
Progress in Biochemistry and Biophysics 2025;52(6):1511-1528
ObjectiveThe study explores the influence of voluntary wheel running on the behavioral abnormalities and the activation state of the hypothalamic-pituitary-adrenal (HPA) axis in autism spectrum disorder (ASD) rats through gut microbiota. MethodsSD female rats were selected and administered either400 mg/kg of valproic acid (VPA) solution or an equivalent volume of saline via intraperitoneal injection on day 12.5 of pregnancy. The resulting offspring were divided into 2 groups: the ASD model group (PASD, n=35) and the normal control group (PCON, n=16). Behavioral assessments, including the three-chamber social test, open field test, and Morris water maze, were conducted on postnatal day 23. After behavioral testing, 8 rats from each group (PCON, PASD) were randomly selected for serum analysis using enzyme-linked immunosorbent assay (ELISA) to measure corticotropin-releasing hormone (CRH), adrenocorticotropic hormone (ACTH), and corticosterone (CORT) concentration, to evaluate the functional state of the HPA axis in rats. On postnatal day 28, the remaining 8 rats in the PCON group were designated as the control group (CON, n=8), and the remaining 27 rats in the PASD group were randomly divided into 4 groups: ASD non-intervention group (ASD, n=6), ASD exercise group (ASDE, n=8), ASD fecal microbiota transplantation group (FMT, n=8), and ASD sham fecal microbiota transplantation group (sFMT, n=5). The rats in the ASD group and the CON group were kept under standard conditions, while the rats in the ASDE group performed 6 weeks of voluntary wheel running intervention starting on postnatal day 28. The rats in the FMT group were gavaged daily from postnatal day 42 with 1 ml/100 g fresh fecal suspension from ASDE rats which had undergone exercise for 2 weeks, 5 d per week, continuing for 4 weeks. The sFMT group received an equivalent volume of saline. After the interventions were completed, behavioral assessments and HPA axis markers were measured for all groups. ResultsBefore the intervention, the ASD model group exhibited significantly reduced social ability, social novelty preference, spontaneous activity, and exploratory interest, as well as impaired spatial learning, memory, and navigation abilities compared to the normal control group (P<0.05). Serum concentration of corticotropin-releasing hormone (CRH), adrenocorticotropic hormone (ACTH), and corticosterone (CORT) in the PASD group were significantly higher than those in the PCON group (P<0.05). Following 6 weeks of voluntary wheel running, the ASDE group showed significant improvements in social ability, social novelty preference, spontaneous activity, exploratory interest, spatial learning, memory, and navigation skills compared to the ASD group (P<0.05), with a significant decrease in serum CORT concentration (P<0.05), and a downward trend in CRH and ACTH concentration. After 4 weeks of fecal microbiota transplantation in the exercise group, the FMT group showed marked improvements in social ability, social novelty preference, spontaneous activity, exploratory interest, as well as spatial learning, memory, and navigation abilities compared to both the ASD and sFMT groups (P<0.05). In addition, serum ACTH and CORT concentration were significantly reduced (P<0.05), and CRH concentration also showed a decreasing trend. ConclusionExercise may improve ASD-related behaviors by suppressing the activation of the HPA axis, with the gut microbiota likely playing a crucial role in this process.
10.Threshold of kurtosis on occupational hearing loss associated with non-steady noise
Yang LI ; Haiying LIU ; Linjie WU ; Jinzhe LI ; Jiarui XIN ; Hua ZOU ; Xin SUN ; Wei QIU ; Changyan YU ; Meibian ZHANG
Journal of Environmental and Occupational Medicine 2025;42(7):779-785
Background Kurtosis reflecting noise's temporal structure is an effective metric for evaluating noise-induced hearing loss (NIHL), and its threshold is still unclear. Objective To explore the energy range of kurtosis and the threshold of NIHL induced by kurtosis in this energy rangeMethods Using cross-sectional design,


Result Analysis
Print
Save
E-mail