1.Multi-component Quality Consistency Evaluation of Leonuri Herba Granules Based on HPLC-DAD-CAD Multi-detector Technique and Chemometrics
Shuangyan LI ; Jun ZHANG ; Cong GUO ; Siyuan LI ; Jipeng DI ; Jiangmin SU ; An LIU ; Xiaodi KOU ; Yan LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(8):174-181
ObjectiveTo systematically evaluate the content differences of 4 components in Leonuri Herba granules, reveal the quality fluctuation patterns of products from the same and different manufacturers, providing scientific basis for the optimization of production process and quality control. MethodsHigh performance liquid chromatography-diode array detector-charged aerosol detector(HPLC-DAD-CAD) was employed to determine the contents of 4 components(syringic acid, leonurine hydrochloride, ferulic acid, and stachydrine hydrochloride) in samples from 19 manufacturers(53 batches, 159 boxes). Additionally, fingerprint profiles were constructed, and the fingerprint dissimilarity(PS) and relative standard deviation(RSD) of different samples from the same manufacturer were calculated. A principal component analysis(PCA) model was established with PS and the RSD values of the 4 components as variables to classify the manufacturers. Finally, samples from 5 manufacturers(M1-M5) covering three consistency groups were selected to calculate three quality consistency parameters, namely intra-batch consistency(PA), inter-batch consistency(PB), and PS. Then, PCA was performed with PA, PB, and PS of these 5 manufacturers as variables. ResultsThe average total content of the 4 index components per bag across the 19 manufacturers ranged from 41.10 mg to 97.54 mg. Among them, the content of stachydrine hydrochloride(a pharmacopoeial quality control component) was 32.46-72.70 mg per bag, all meeting the requirements of the 2025 edition of the Pharmacopoeia of the People's Republic of China, with RSD of 1.7%-17.1%. The content ranges of the other 3 components were as follows:syringic acid of 1.43-41.92 mg per bag, leonurine hydrochloride of 0.67-11.85 mg per bag, and ferulic acid of 0.11-3.81 mg per bag. Notably, leonurine hydrochloride exhibited the most significant content fluctuation among samples from the same manufacturer(RSD of 4.8%-59.2%). PCA results showed that the 19 manufacturers could be classified into 3 categories. Samples from 8 manufacturers(M2, M6, M7, M8, M10, M15, M17, M18) demonstrated relatively high consistency, five manufacturers(M3, M9, M12, M13, M14) showed moderate consistency, six manufacturers(M1, M4, M5, M11, M16, M19) exhibited low consistency. The two methods yielded consistent classification results for the 5 representative manufacturers, verifying the reliability of the proposed method. Among these, manufacturer M2 showed the best quality consistency and the highest total content of indicator components among M1-M5. ConclusionThe HPLC-DAD-CAD multi-detector hyphenation technology established in this study enables the accurate detection of 4 components in Leonuri Herba granules. Significant differences in the total content of these four components are observed among products from 19 manufacturers. The application of 2 consistency evaluation methods combined with PCA can effectively classify their consistency into 3 categories, and the classification results of the 2 methods are highly consistent. This study provides scientific basis for the process optimization and quality standard improvement of Leonuri Herba granules.
2.Multi-component Quality Consistency Evaluation of Leonuri Herba Granules Based on HPLC-DAD-CAD Multi-detector Technique and Chemometrics
Shuangyan LI ; Jun ZHANG ; Cong GUO ; Siyuan LI ; Jipeng DI ; Jiangmin SU ; An LIU ; Xiaodi KOU ; Yan LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(8):174-181
ObjectiveTo systematically evaluate the content differences of 4 components in Leonuri Herba granules, reveal the quality fluctuation patterns of products from the same and different manufacturers, providing scientific basis for the optimization of production process and quality control. MethodsHigh performance liquid chromatography-diode array detector-charged aerosol detector(HPLC-DAD-CAD) was employed to determine the contents of 4 components(syringic acid, leonurine hydrochloride, ferulic acid, and stachydrine hydrochloride) in samples from 19 manufacturers(53 batches, 159 boxes). Additionally, fingerprint profiles were constructed, and the fingerprint dissimilarity(PS) and relative standard deviation(RSD) of different samples from the same manufacturer were calculated. A principal component analysis(PCA) model was established with PS and the RSD values of the 4 components as variables to classify the manufacturers. Finally, samples from 5 manufacturers(M1-M5) covering three consistency groups were selected to calculate three quality consistency parameters, namely intra-batch consistency(PA), inter-batch consistency(PB), and PS. Then, PCA was performed with PA, PB, and PS of these 5 manufacturers as variables. ResultsThe average total content of the 4 index components per bag across the 19 manufacturers ranged from 41.10 mg to 97.54 mg. Among them, the content of stachydrine hydrochloride(a pharmacopoeial quality control component) was 32.46-72.70 mg per bag, all meeting the requirements of the 2025 edition of the Pharmacopoeia of the People's Republic of China, with RSD of 1.7%-17.1%. The content ranges of the other 3 components were as follows:syringic acid of 1.43-41.92 mg per bag, leonurine hydrochloride of 0.67-11.85 mg per bag, and ferulic acid of 0.11-3.81 mg per bag. Notably, leonurine hydrochloride exhibited the most significant content fluctuation among samples from the same manufacturer(RSD of 4.8%-59.2%). PCA results showed that the 19 manufacturers could be classified into 3 categories. Samples from 8 manufacturers(M2, M6, M7, M8, M10, M15, M17, M18) demonstrated relatively high consistency, five manufacturers(M3, M9, M12, M13, M14) showed moderate consistency, six manufacturers(M1, M4, M5, M11, M16, M19) exhibited low consistency. The two methods yielded consistent classification results for the 5 representative manufacturers, verifying the reliability of the proposed method. Among these, manufacturer M2 showed the best quality consistency and the highest total content of indicator components among M1-M5. ConclusionThe HPLC-DAD-CAD multi-detector hyphenation technology established in this study enables the accurate detection of 4 components in Leonuri Herba granules. Significant differences in the total content of these four components are observed among products from 19 manufacturers. The application of 2 consistency evaluation methods combined with PCA can effectively classify their consistency into 3 categories, and the classification results of the 2 methods are highly consistent. This study provides scientific basis for the process optimization and quality standard improvement of Leonuri Herba granules.
3.Lightweight end-to-end model-based korotkoff sounds phase identification and blood pressure measurement
Zhiyu JIANG ; Wenyi KOU ; Li LI ; Qijun ZHAO ; Yongjun QIAN ; Fan PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(02):248-254
Objective To propose a lightweight end-to-end neural network model for automated Korotkoff sound phase recognition and subsequent blood pressure (BP) measurement, aiming to improve measurement accuracy and population adaptability. Methods We developed a streamlined architecture integrating depthwise separable convolution (DSConv), multi-head attention (MHA), and bidirectional gated recurrent unit (BiGRU). The model directly processes Korotkoff sound time-series signals to identify auscultatory phases. Systolic BP (SBP) and diastolic BP (DBP) were determined using phase Ⅰ and phaseⅤdetections, respectively. Given the clinical relevance of phase Ⅳ for specific populations (e.g., children and pregnant women, denoted as DBPⅣ), BP values from this phase were also recorded.Results The study enrolled 106 volunteers with 70 males and 36 females at mean age of (40.0±12.0) years. The model achieved 94.25% phase recognition accuracy. Measurement errors were (0.1±2.5) mm Hg (SBP), (0.9±3.4) mm Hg (DBPⅣ), and (0.8±2.6) mm Hg (DBP). Conclusion Our method enables precise phase recognition and BP measurement, demonstrating potential for developing population-adaptive blood pressure monitoring systems.
5.Computer-simulated repositioning combined with pelvic reduction frame for treatment of anteroposterior compression-III pelvic fractures
Zhenyang GAO ; Xiuan ZENG ; Qibing YANG ; Xianshuai KOU ; Kejing WANG ; Meng LI
Chinese Journal of Tissue Engineering Research 2025;29(9):1870-1875
BACKGROUND:Pelvic fractures encompass a range of types,and the utilization of a pelvic reduction frame for restoration often lacks a systematic repositioning method.Instead,it relies on the operator's experience in conjunction with fluoroscopic findings,which can lead to uncertainty and non-reproducibility. OBJECTIVE:To investigate the clinical efficacy of combining computer-simulated repositioning techniques with a pelvic reduction frame for the treatment of anteroposterior compression-III pelvic fractures. METHODS:A retrospective analysis was conducted on 19 patients with anteroposterior compression-III pelvic fractures who underwent preoperative repositioning via computer simulation and intraoperative repositioning with the assistance of a pelvic reduction frame between January 2018 and December 2021.Among them,7 cases were fixed with double plate in anterior ring and 12 cases were fixed with single plate combined with anterior subcutaneous internal fixation(INFIX).All patients received posterior ring fixation with two sacroiliac screws.Operative duration,intraoperative reduction time,the frequency of intraoperative fluoroscopy use,blood loss,and follow-up duration were documented.These data were utilized to monitor fracture healing time and postoperative complications.Fracture reduction quality was evaluated according to the Matta scale,and the Majeed Pelvic Function Score was employed to assess patient function during the final follow-up. RESULTS AND CONCLUSION:(1)Surgery was successfully completed in all 19 patients.The anterior ring was secured with double plates in 7 cases,while a single plate combined with INFIX was utilized in 12 cases.The posterior ring was stabilized with two sacroiliac screws,specifically targeting the S1 and S2 cones.(2)The operation duration ranged from 74 to 147 minutes,with a mean of(101.63±19.55)minutes.Intraoperative repositioning took place over a period of 26 to 41 minutes,with a mean of(38.11±3.31)minutes.The number of intraoperative fluoroscopies conducted ranged from 35 to 81,with a mean of(62.68±13.11)times.Intraoperative bleeding volumes varied from 60 to 130 mL,with a mean of(85.37±20.57)mL.(3)All the patients were diligently monitored for a duration of 12 to 26 months.Fracture healing was observed within a time frame of 12 to 20 weeks,with a mean of(16.37±2.50)weeks.(4)The evaluation according to Matta's criteria one day post-surgery revealed excellent outcomes in 14 cases and good outcomes in 5 cases.At the final follow-up,the Majeed function score indicated excellent results in 16 cases and good results in 3 cases.(5)Two patients experienced localized fat liquefaction phenomena,characterized by redness,swelling,and oozing at the incision site,which gradually resolved with proactive dressing changes.None of the patients encountered complications such as internal fixation loosening,loss of fracture reduction,or nerve injuries post-surgery.It is concluded that the combined approach of using computer-simulated repositioning techniques in conjunction with pelvic reduction frames for the treatment of anteroposterior compression-III pelvic fractures has advantages in enhancing repositioning efficiency and improving pelvic function.
6.Clinical Observation on 60 Cases of Knee Osteoarthritis Treated with Heat-Sensitive Moxibustion
Lu TIAN ; Hongwu XIE ; Meihua LIU ; Jing ZHANG ; Shaozhong XU ; Changjun LI ; Zhixiong KOU
Journal of Traditional Chinese Medicine 2025;66(5):492-500
ObjectiveTo explore the central neuroregulation mechanism of heat-sensitive moxibustion for knee osteoarthritis on pain relief. MethodsThirty patients who did not have experience of Deqi (得气) during heat-sensitive moxibustion treatment were assigned to the "non-Deqi group", while another 30 patients who had experience of Deqi were assigned to the "Deqi group". Both groups received moxibustion at the left Heding (EX-LE2) acupoint. In the Deqi group, after the patients experienced sensation of Deqi at the acupoint, moxibustion was applied at approximately 3 cm from the skin for 10 minutes; in the non-Deqi group, moxibustion was also applied at approximately 3 cm from the skin for 10 minutes. Both groups received treatment once daily for 10 consecutive days. Knee joint pain was assessed before and after treatment using the visual analog scale (VAS). Resting-state functional magnetic resonance imaging (rs-fMRI) scans were performed on all participants before the first treatment session and after the final session on the 10th day. The fractional amplitude of low-frequency fluctuations (fALFF) maps before and after treatment were processed using the SPM12 module by MATLAB. ResultsAfter treatment, VAS scores in both groups were significantly lower than before treatment (P<0.05 or P<0.01), with the Deqi group showing significantly lower VAS scores than the non-Deqi group (P<0.01). Compared to before treatment, the Deqi group exhibited significant activation in the prefrontal cortex (t = 6.28), white matter (t = 6.36), and left temporal lobe (t = 9.33), while significant inhibition was observed in the occipital lobe (t = -9.86) and right cerebrum (t = -4.54, P<0.01); in the non-Deqi group, significant changes after treatment were observed in the left occipital lobe (t = -6.42), left medial frontal gyrus (t = -4.35), left middle frontal gyrus (t = -4.74), right superior frontal gyrus (t = -4.82), right superior temporal gyrus (t = -6.61), and right cerebellar posterior lobe (t = -8.64), all of which were in inhibited states (P<0.01). Compared to the non-Deqi group, the Deqi group exhibited significant activation after treatment in the external nucleus (t = 5.77), white matter (t = 3.58), right cerebrum (t = 5.84), left cerebellum (t = 5.35), and left cerebrum (t = 4.32), while significant inhibition was observed in the prefrontal cortex (t = -4.16), occipital lobe (t = -4.87), and precentral gyrus (t = -4.46, P<0.01). ConclusionsHeat-sensitive moxibustion provides better analgesic effects for knee osteoarthritis under state of Deqi. Its central neuroregulation mechanism may be related to the involvement of the frontal lobe, temporal lobe, occipital lobe, external nucleus, white matter, right cerebrum, left cerebellum, left cerebrum, and precentral gyrus in modulating pain signals.
7.Research on the reconstruction of doctor-patient relationships in patients with sudden deafness from the perspective of narrative medicine
Jingjing LI ; XiaoHui KOU ; Hui LYU ; Aling ZHANG ; Hui YANG ; Weijun MA ; Jiayi WANG ; Caiqin WU
Chinese Medical Ethics 2025;38(6):718-726
Patients with sudden deafness encounter greater psychological challenges and communication barriers after experiencing sudden hearing loss, and traditional medical models often fail to adequately address their unique needs. This paper analyzed the current situation of emotional and behavioral changes in patients with sudden deafness, and the gap between their expectations and the reality of medical care. From the perspective of narrative medicine, the theory and characteristics of the reconstruction of the doctor-patient relationships in patients with sudden deafness were explored. The results showed that narrative medicine can enhance patients’ emotional resonance and understanding, improve the efficiency and quality of doctor-patient communication, promote the formulation of personalized treatment plans, and enhance treatment adherence and satisfaction. Based on these results, strategies and pathways for the reconstruction of doctor-patient relationships for patients with sudden deafness were proposed, including building empathetic bridges and tapping into mechanisms of emotional resonance within narrative medicine; optimizing communication strategies and promoting the application of narrative techniques in doctor-patient dialogues; connecting narrative pathways and advocating the exploration of stories and strategies in personalized treatments; as well as facilitating treatment adherence and making full use of the psychodynamic effects of narrative medicine. Narrative medicine, as a patient-centered medical practice, can effectively promote the reconstruction of doctor-patient relationships, enhance treatment effectiveness, and offer a more humane treatment experience for patients.
8.Sinicization and reliability and validity the European organization for research and treatment of cancer quality of life questionnaire-head and neck 43
Qing LYU ; Junqiu LI ; Fa ZHANG ; Cuimin KOU ; Yan LI ; Shuxiang ZHANG ; Yanxin ZHANG ; Lixia NIU ; Yiming ZHU ; Xin YUAN ; Linan QIN ; Shaoyan LIU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2025;60(6):617-623
Objective:To translate the European organization for research and treatment of cancer quality of life questionnaire-head and neck 43(EORTC QLQ-H&N43) and to conduct cultural debugging and reliability and validity testing for the Chinese version of the scale.Methods:The Chinese version of EORTC QLQ-H&N43 was formed through literal translation, integration, back translation, group discussion, cultural adjustment, and pre-investigation of the English version of the scale. From March 2023 to December 2023, convenience sampling was used to investigate 254 patients with head and neck tumors at the Cancer Hospital of the Chinese Academy of Medical Sciences, including 197 males and 57 females, aged (55.6±13.6) years. SPSS 25.0 statistical software was used to analyze the performance of the scale.Results:The Chinese version of EORTC QLQ-H&N43 retained all 43 items. After evaluation by 5 experts, the content validity index (I-CVI) at the item level of the scale ranged from 0.80 to 1.00, and the average content validity index (S-CVI/Ave) at the scale level was 0.991. Through exploratory factor analysis, a total of 9 common factors were extracted, with a cumulative variance contribution rate of 68.158%; Cronbach′s α coefficient of the total scale was 0.943, and the half reliability was 0.896.Conclusion:The Chinese version of EORTC QLQ-H&N43 has good reliability and validity, which can be used as an effective tool to evaluate the quality of life of head and neck cancer patients in China.
9.Application status of intraoperative neural monitoring technology during thyroid surgery
Yishen ZHAO ; Peiyao WANG ; Tie WANG ; Changlin LI ; Fang LI ; Zihan ZHAO ; Jiedong KOU ; Wen TIAN ; Kewei JIANG ; Ping WANG ; Hao ZHANG ; Hui SUN
Chinese Journal of Surgery 2025;63(6):495-499
Intraoperative neural monitoring (IONM) combines electrophysiology with anatomy to monitor nerve function during thyroid surgery,and has become an important auxiliary technology for neuroprotection. After more than ten years of development,the technology has been widely applied and popularized in China,promoting the development of a number of new technologies in the industry. Combined with the questionnaire survey data of the Chinese Neural Monitoring Study Group,this paper aims to summarize the clinical effect of IONM technology, the application status and existing problems at home and abroad, and propose the possible future development direction.
10.A survey of clinical application of stereotactic radiotherapy technology in China in 2024
Xiaoxue KOU ; Jiayi YU ; Jingwei ZHANG ; Nan BI ; Xuwei CAI ; Guanghui CHENG ; Yufei LU ; Yanyang WANG ; Ligang XING ; Yonggang XU ; Jianxin XUE ; Li ZHANG ; Hongqing ZHUANG ; Anhui SHI
Chinese Journal of Radiation Oncology 2025;34(9):897-904
Objective:To investigate the current status of application of stereotactic body radiation therapy (SBRT) in China, aiming to provide reference for promoting the development of this technology.Methods:From January to March 2024, a questionnaire was designed and distributed online, targeting member units of the Professional Committee of Stereotactic Radiosurgery Treatment, which covers 175 radiotherapy units in 30 provinces and regions nationwide. The survey focused on the current application of SBRT technology and its utilization in the treatment of early-stage non-small cell lung cancer (NSCLC). A statistical description of the survey results was presented.Results:Of 175 questionnaires distributed, a total of 130 valid responses were collected, with an effective response rate of 74.3%. A total of 81.5% (106/130) of the units had implemented SBRT technology, and 99.1% of the respondents believed it was necessary to further promote SBRT technology, yet the actual training rate was only 67.0%. SBRT equipment configuration: there were a total of 267 SBRT equipment, featuring a diverse range of types, with traditional linear accelerators as the mainstays, accounting for 76.0% ( n=203), followed by 12.0% ( n=32) for TOMO, 6.4% ( n=17) for Cyber knife, 3.7% ( n=10) for Gamma knife, and proton/heavy ion equipment at 1.5% ( n=4), respectively. The percentage of units with multi-leaf collimator leaf widths ≤0.5 cm was 93.4% (99/106). The application of SBRT: the first radiotherapy unit commenced SBRT in 2000, and this technology entered a period of rapid growth after 2015, sustaining a steady increase over the past decade; SBRT technology was mainly applied in the brain, lung, liver, bone, adrenal gland, and kidney, with application rates of 97.2%, 94.3%, 86.8%, 71.7%, 56.6%, and 27.4%, respectively, while the application rates for the pancreas, metastatic lymph nodes, and other parts were less than 5%. Current status of SBRT technology application in early-stage NSCLC: 90.6% (96/106) of units had implemented SBRT; pre-treatment multi-disciplinary diagnosis and treatment accounted for 77% (74/96); the proportion of application units for peripheral and central type lung cancer lesions both exceeded 57.3%, whereas the application rate for ultra-central type and lesions > 5 cm lung cancer was less than 30%; there was significant variability in the selection of reference guidelines, dose fractionation patterns, and the concept of central type among units. Conclusions:The development of SBRT technology in China is in a period of steady growth, but several issues such as low training rate and lack of standardization still exist. The survey results provide important reference for clinical training and promotion of SBRT technology in China.

Result Analysis
Print
Save
E-mail