1.Feasibility of optimizing radiation dose for three-dimensional printing of the maxillofacial bone based on low-dose CT technology
Guan LI ; Haopeng WANG ; Jinbao WANG ; Xinhao SONG ; Guochu QIN ; Yang SHAO
Chinese Journal of Tissue Engineering Research 2026;30(6):1384-1389
BACKGROUND:Maxillofacial bone three-dimensional(3D)printing technology has been widely used in clinical diagnosis and treatment,but the data source before performing maxillofacial bone 3D printing mainly comes from the CT scanning data.The lens,thyroid and other parts of the human body are extremely sensitive to X-rays;therefore,it is particularly important to effectively reduce the dose of CT radiation when acquiring the data source.OBJECTIVE:To explore the feasibility of low-dose CT technology in optimizing radiation dose for maxillofacial bone 3D printing.METHODS:The medical records of 65 patients who underwent maxillofacial bone 3D printing in the Department of Stomatology at the General Hospital of Northern Theater Command from March 2021 to December 2023 were retrospectively collected and categorized into a conventional CT-dose 3D printing group(conventional CT-dose,120 kVp,automated tube current modulation,n=32)and a low-CT-dose 3D printing group(low-CT-dose group,80 kVp,automated tube current modulation,n=33).The effective dose of radiation was calculated and compared between the two groups.A Likert scale was used to evaluate the quality of 3D printing in the two groups,and the measurement bias and consistency between evaluators were measured using the Bland-Altman method.RESULTS AND CONCLUSION:(1)There was no significant difference in the general demographic characteristics(age,height,weight,body mass,sex,and body mass index)between the two groups(all P>0.05).(2)The effective dose value of the low CT-dose 3D printing group was(0.3±0.1)mSv,which was about 62.5%lower than that in the conventional CT-dose 3D printing group[(0.8±0.1)mSv].(3)There was no significant difference in the subjective scoring of 3D printing quality between the two groups(all P>0.05).The subjective consistency among evaluators was good,with Kappa values of 0.85,0.80,and 0.76.The scatter points in the Bland-Altman for both protocols were uniformly distributed within the standard deviation line,indicating good consistency between the two groups.To conclude,low-dose CT technology can be effectively applied in maxillofacial bone 3D printing,reducing radiation dose without affecting the quality of 3D printing.
2.Feasibility of optimizing radiation dose for three-dimensional printing of the maxillofacial bone based on low-dose CT technology
Guan LI ; Haopeng WANG ; Jinbao WANG ; Xinhao SONG ; Guochu QIN ; Yang SHAO
Chinese Journal of Tissue Engineering Research 2026;30(6):1384-1389
BACKGROUND:Maxillofacial bone three-dimensional(3D)printing technology has been widely used in clinical diagnosis and treatment,but the data source before performing maxillofacial bone 3D printing mainly comes from the CT scanning data.The lens,thyroid and other parts of the human body are extremely sensitive to X-rays;therefore,it is particularly important to effectively reduce the dose of CT radiation when acquiring the data source.OBJECTIVE:To explore the feasibility of low-dose CT technology in optimizing radiation dose for maxillofacial bone 3D printing.METHODS:The medical records of 65 patients who underwent maxillofacial bone 3D printing in the Department of Stomatology at the General Hospital of Northern Theater Command from March 2021 to December 2023 were retrospectively collected and categorized into a conventional CT-dose 3D printing group(conventional CT-dose,120 kVp,automated tube current modulation,n=32)and a low-CT-dose 3D printing group(low-CT-dose group,80 kVp,automated tube current modulation,n=33).The effective dose of radiation was calculated and compared between the two groups.A Likert scale was used to evaluate the quality of 3D printing in the two groups,and the measurement bias and consistency between evaluators were measured using the Bland-Altman method.RESULTS AND CONCLUSION:(1)There was no significant difference in the general demographic characteristics(age,height,weight,body mass,sex,and body mass index)between the two groups(all P>0.05).(2)The effective dose value of the low CT-dose 3D printing group was(0.3±0.1)mSv,which was about 62.5%lower than that in the conventional CT-dose 3D printing group[(0.8±0.1)mSv].(3)There was no significant difference in the subjective scoring of 3D printing quality between the two groups(all P>0.05).The subjective consistency among evaluators was good,with Kappa values of 0.85,0.80,and 0.76.The scatter points in the Bland-Altman for both protocols were uniformly distributed within the standard deviation line,indicating good consistency between the two groups.To conclude,low-dose CT technology can be effectively applied in maxillofacial bone 3D printing,reducing radiation dose without affecting the quality of 3D printing.
3.Comparative Analysis of Clinical Efficacy of Traditional Chinese Medicine Manipulative Reduction Combined with Small Splint Fixation Versus Surgical Treatment for Type A Distal Radius Fracture
Yang SHAO ; Zihan WANG ; Jianwei WANG ; Guoda DAI ; Hengyan CUI ; Zhen HUA ; Tingchen ZHU ; Shaoshuo LI ; Jun MAO ; Fenghua CHEN ; Shuai TAO ; Mao WU
Journal of Traditional Chinese Medicine 2026;67(10):1078-1085
ObjectiveTo compare the clinical efficacy of traditional Chinese medicine (TCM) manipulative reduction combined with small splint fixation versus surgical treatment for type A distal radius fracture (DRF) and to explore the factors influencing the choice of treatment. MethodsA multi-center retrospective study was conducted, collecting data from 1237 type A DRF patients treated in 11 hospitals in Jiangsu province from September, 2023 to April, 2025. Among them, 851 patients in the TCM group received manipulative reduction combined with small splint fixation, and 386 patients in the surgical group underwent open reduction and internal fixation. Visual analog scale (VAS) scores for pain and radiographic indicators including palmar tilt, ulnar deviation, and radial height were compared before treatment, 5-7 days after treatment, and 4-6 weeks after treatment. The wrist joint function scores including Dienst and Gartland-Werley scores at 12 weeks after treatment were recorded. Subgroup analysis was conducted for the excellent rate of Dienst and Gartland-Werley scores, stratified by age (<50, 50-59, 60-69, ≥70 years old) and AO subtypes (A1, A2, A3). A multivariate logistic regression model was used to identify independent factors influencing treatment choice. ResultsOn 5-7 days after treatment, the surgical group had lower VAS scores than the TCM group, while 4-6 weeks after treatment, the TCM group showed lower VAS scores than the surgical group (P<0.01). In terms of radiographic indicators, except for the palmar tilt before treatment being higher in the surgical group than in the TCM group (P<0.01), there were no significant differences in palmar tilt, ulnar deviation, and radial height at other timepoints (P>0.05). Twelve weeks after treatment, the surgical group had a higher average Gartland-Werley score and the excellent rate than the TCM group (P<0.01). Subgroup analysis showed that in patients with A2 type DRF aged 50-59 and 60-69 years old, the excellent rates of Dienst and Gartland-Werley scores in the TCM group were higher than those in the surgical group (P<0.05). Multivariate logistic regression analysis revealed that age, palmar tilt, ulnar deviation, and the degree of swelling on the affected side were independent factors influencing the choice of treatment (P<0.05). ConclusionBoth TCM manipulative reduction combined with small splint fixation and surgical treatment for type A DRF can achieve good therapeutic effects. TCM manipulative reduction combined with small splint fixation has certain advantages in medium- and long-term pain relief, especially in elderly patients, where wrist joint function recovery is more stable. Age, palmar tilt, ulnar deviation, and swelling degree are the main factors influencing the treatment choice.
4.Clinical Efficacy and Radiographic Outcomes of Manipulative Reduction Combined with Small Splint Fixation for Distal Radius Fractures:A Retrospective Multicenter Study with Propensity Score Matching
Mao WU ; Guoda DAI ; Yang SHAO ; Shaoshuo LI ; Zhen HUA ; Hengyan CUI ; Tingchen ZHU ; Dipeng LI ; Jintao LIU ; Ming ZHOU ; Peimin WANG ; Liyong ZHANG ; Jianwei WANG
Journal of Traditional Chinese Medicine 2026;67(10):1086-1092
ObjectiveTo observe the clinical efficacy and radiographic outcomes of manipulative reduction combined with small splint fixation in the treatment of distal radius fractures. MethodsThe clinical data of 1051 patients with distal radius fractures were retrospectively collected from five hospitals included in the Jiangsu Diagnosis and Treatment Data Platform for Traditional Chinese Medicine(TCM) Dominant Diseases. Propensity score matching at a 1∶4 ratio was applied, resulting in 580 cases selected for final analysis, which comprised 448 patients in the TCM group(manipulative reduction plus small splint fixation) and 132 in the surgical treatment group(open reduction and internal fixation). Each group was further stratified into type A, B, and C subgroups based on AO fracture classification. Radiographic indicators including palmar tilt, radial inclination, and radial height were compared between groups before treatment and 1 day, 1 week, and 4-6 weeks after treatment, and pain visual analog scale(VAS) scores before treatment and 1 week and 4-6 weeks after treatment were also compared. Wrist joint function was assessed 12 weeks after treatment, using the Dienst wrist function score and the Gartland and Werley(G-W) wrist function score. Additionally, the radiographic indicators at different timepoints and the 12-week wrist function levels were compared between groups across different fracture types. ResultsNo statistically significant difference was observed in radiographic indicators and VAS scores at all timepoints before and after treatment, as well as wrist joint function grades assessed by the Dienst score and the G-W score at 12 weeks after treatment (P>0.05). Compared to those before treatment, both groups showed increased palmar tilt, radial inclination, and radial height 1 week and 4-6 weeks after treatment, and decreased VAS scores (P<0.05). Compared to those 1 week after treatment, both groups showed a decrease in palmar tilt, an increase in radial inclination and radial height, and a reduction in VAS score 4-6 weeks after treatment(P<0.05). In type A and B subgroups, the surgical treatment group had a higher radial inclination than the TCM group 4-6 weeks after treatment, while in the type C subgroup, a higher radial height was shown in the surgical treatment group than in the TCM group 4-6 weeks after treatment(P<0.05). In type C subgroup, there was significant difference between groups in the wrist joint function by G-W scores 12 weeks after treatment(P<0.05). ConclusionManipulative reduction combined with small splint fixation can maintain fracture alignment and alleviate pain in treating distal radius fractures, which achieves therapeutic outcomes comparable to surgical treatment. It is particularly suitable for type A and B fractures and can be considered an effective treatment option for distal radius fractures.
5.Construction and Clinical Validation of a Deep Learning-Based Automatic Measurement Model for Palmar Tilt and Radial Inclination in Distal Radius Fractures
Guoda DAI ; Jianwei WANG ; Mao WU ; Bin KANG ; Yang SHAO ; Hengyan CUI ; Shaoshuo LI ; Tingchen ZHU ; Zhen HUA ; Zhongming SHEN ; Jintao LIU ; Ming ZHOU
Journal of Traditional Chinese Medicine 2026;67(10):1093-1100
ObjectiveTo construct an automatic measurement model for palmar tilt and radial inclination suitable for traditional Chinese medicine (TCM) clinical scenarios, and to validate its accuracy and efficiency in TCM manipulative reduction settings. MethodsData on anteroposterior (AP) and lateral X-rays of distal radius fractures were collected from patients admitted to 18 TCM/ integrated TCM and western medicine hospitals in Jiangsu province between September 1st, 2023, and September 1st, 2024, via the Jiangsu Diagnosis and Treatment Big Data Platform for TCM Dominant Diseases. A medical image segmentation framework based on multi-scale feature fusion and edge-awareness was employed, combined with anatomical knowledge specific to TCM orthopedics, to optimize the feature extraction strategy of an artificial intelligence (AI) model. This framework enabled automatic segmentation of fracture regions and measurement of distal radius palmar tilt and radial inclination. The accuracy of the AI model in measuring radial inclination and volar tilt was validated, and the measurement time and average time gain rate of the AI model were compared to those of manual measurement. ResultsA total of 15,444 AP and lateral X-ray images of distal radius fractures were collected, and were divided into a training set (11,144 images, 5066 AP and 6078 lateral), a validation set (3700 images, 1840 AP and 1860 lateral), and an independent test set (600 images, 300 AP and 300 lateral) after preprocessing. In the measurement of 300 AP X-rays in the independent test set for radial inclination, when the degree error between AI measurement and manual measurement was <3° and <5°, AI measurement accuracy was 83% and 93%, respectively. In 300 lateral X-rays in the test set for palmar tilt, when AI measurements had an error of <3° and <5° compared to manual measurements, corresponding accuracy rate was 78% and 90%, respectively. For 50 X-ray images, AI measurement time was (1.37±0.05) min for radial inclination while manual measurement time was (22.57±2.52) min (P<0.001); in terms of palmar tilt, the AI measurement time was (1.33±0.14) min, shorter than (23.70±2.80) min for manual measurement time (P<0.001). Average time gain rates for manual and AI measurements were 93.93% and 94.39% respectively. ConclusionAn automatic measurement model for palmar tilt and radial inclination in distal radius fractures has been established, enabling more accurate and efficient assessment as well as providing a tool to support the quantitative evaluation of the efficacy of TCM manipulative reduction and large-sample clinical research.
6.Expert consensus on precise intervention with repetitive transcranial magnetic stimulation for sleep disorders in the elderly
Yuan SHAO ; Jian WANG ; Wei LIANG ; Yingli ZHANG ; Gangqiang HOU ; Xia LI ; Yi XING ; Lu WANG ; Shi TANG ; Yongjun WANG
Sichuan Mental Health 2026;39(2):97-105
In recent years, repetitive transcranial magnetic stimulation (rTMS) has garnered significant attention as a therapeutic approach for sleep disorders in the elderly. However, the prevailing rTMS protocols are predominantly developed based on normative neurophysiological data derived from young adults and fail to incorporate individualized parameters tailored to the brain characteristics of the elderly. To address this gap, the consensus development group synthesized the latest evidence from 2010 to 2025 and established a standardized rTMS protocol specifically for elderly patients with sleep disorders. Adhering to the Appraisal of Guidelines for Research and Evaluation II (AGREE II) framework, systematically screened randomized controlled trials (RCTs) and systematic reviews regarding rTMS in the treatment of sleep disorders across various conditions. Meanwhile, the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was employed to rigorously grade the quality of evidence and the strength of recommendations. This consensus guideline delineates precise rTMS protocols for the management of sleep disorders in the elderly, highlights the adjustment of stimulation intensity according to scalp-cortex distance recommends either MRI‑guided neuronavigation or the Beam F3/F4 heuristic approach for accurate target localization, thereby providing precise rTMS intervention protocol for sleep disorders in the elderly, aiming to enhance clinical efficacy while ensuring treatment safety. [Funded by National Key Research and Development Program (number, 2023YFC3603200); General Program of Shenzhen Science and Technology Innovation Commission (number, JCYJ20240813112859008, JCYJ20240813112900002); Youth Program of Shenzhen Kangning Hospital (number, KN2023A004); www.guidelines-registry.cn number, PREPARE-2026CN530]
7.Mechanism of action of remifentanil in alleviating lung ischemia-reperfusion injury in rats by modulating HIF-1α/NLRP3 pathway to inhibit cell pyroptosis
Lifang ZHAO ; Jiangong YANG ; Mingyong LI ; Kun SHAO ; Changli SHEN ; Jiajie LI ; Hong ZHU ; Liangchao QU
Acta Universitatis Medicinalis Anhui 2026;61(3):395-401
ObjectiveTo investigate the mechanism of action of remifentanil (RMZL) in alleviating lung ischemia-reperfusion injury (LIRI) in rats by inhibiting pyroptosis through modulating hypoxia inducible factor-1α (HIF-1α)/NOD-like receptor thermal protein domain associated protein 3 (NLRP3) pathway. MethodsRats were stochastically assigned into Control group, LIRI group, RMZL low-dose group, RMZL medium-dose group, RMZL high-dose group, and RMZL high-dose+HIF-1α activator dimethyloxallyl glycine (DMOG) group, with 18 rats in each group. Rats in Control group only had their left pulmonary hilum free and did not undergo ischemia-reperfusion treatment. Except for the Control group, LIRI models were constructed in all other groups. Rats in LIRI group were intraperitoneally injected with an equal amount of physiological saline 15 minutes before constructing LIRI model; rats in Control group were intraperitoneally injected with an equal amount of physiological saline 15 minutes before freeing left pulmonary hilum; rats in other groups were intraperitoneally injected with corresponding dose of drug 15 minutes before constructing LIRI model. The wet/dry weight ratio of lungs was calculated. HE staining was used to study lung tissue pathology. Immunofluorescence staining was used to detect the relative fluorescence intensity of gasdermin D (GSDMD) and NLRP3 double positive cells in lung tissue. ELISA was used to detect interleukin-1β and IL-18 in lung tissue. Western blot was used to detect HIF-1α, NLRP3, cysteine-aspartic protease-1 (Cleaved caspase-1), and gasdermin D-N (GSDMD-N) proteins in lung tissue. ResultsCompared to the Control group, the LIRI group showed disordered alveolar structure, thickened alveolar septa, and abundant inflammatory cell infiltration in rats. The lung wet/dry weight ratio, relative fluorescence intensity of GSDMD and NLRP3 double positive cells in lung tissue, IL-1β, IL-18 levels, and HIF-1α, NLRP3, Cleaved caspase-1, and GSDMD-N proteins increased (P0.05). For the LIRI group, rats in the RMZL low, medium, and high-dose groups displayed attenuated alveolar septal thickening and reduced inflammatory cell infiltration. The lung wet/dry weight ratio, relative fluorescence intensity of GSDMD and NLRP3 double positive cells in lung tissue, IL-1β, IL-18 levels, and HIF-1α, NLRP3, Cleaved caspase-1, and GSDMD-N proteins declined, and the RMZL high-dose group showed the most prominent trend (P0.05). Compared with the RMZL high-dose group, rats in the RMZL high-dose+DMOG group exhibited thickened alveolar septa and more inflammatory cell infiltration, along with increased lung wet/dry weight ratio, relative fluorescence intensity of GSDMD and NLRP3 double positive cells in lung tissue, levels of IL-1β and IL-18, and protein expression of HIF-1α, NLRP3, Cleaved caspase-1, and GSDMD-N (P0.05). ConclusionRMZL may inhibit pyroptosis in LIRI rats by suppressing HIF-1α/NLRP3 pathway.
8.Evaluation of the Angle Deviation between Pilot Holes and Actual Implanted Pedicle Screw Trajectories in Freehand Pedicle Screw Placement for Thoracolumbar Spine Surgery: The Impact of Tapping and Work Experience
Jie SHAO ; Shaokang HUANG ; Yiping LUO ; Bingkun MENG ; Qunfei YU ; Yi ZHANG ; Wei LI ; Yushu BAI ; Ziqiang CHEN
Clinics in Orthopedic Surgery 2026;18(1):87-95
Background:
To investigate directional deviations between pilot holes and final pedicle screw trajectories in freehand placement and analyze risk factors for misplacement. While pedicle screws are widely used in thoracolumbosacral surgery, directional deviations between pilot holes and final screw trajectories remain understudied as potential risk factors for misplacement.
Methods:
Thirty-three patients undergoing posterior fixation were prospectively enrolled. Inertial measurement units (IMUs) tracked the spatial positions of pedicle finders and screwdrivers via custom software. Surgeons (n = 6) were stratified into senior, middle, and junior groups. Analyzed variables included the use of tapping, surgeon experience, spinal deformity status, screw tip morphology, and surgical parameters.
Results:
Among 198 implanted screws (6.00 ± 2.88/patient), all exhibited trajectory deviations (8.12° ± 3.47°). Tapping significantly reduced deviations (7.23° ± 3.23° vs. 8.87° ± 3.31°, p < 0.01). Senior surgeons achieved smaller deviations (7.34° ± 3.33°) than the middle group (8.60° ± 3.51°, p = 0.039) and junior group (8.68° ± 3.49°, p = 0.022). Multivariate analysis confirmed tapping (p = 0.001) and senior experience (p = 0.023) as protective factors. No significant associations emerged for spinal deformity (8.43° ± 3.73° vs. 7.97° ± 3.35°, p = 0.377), screw tip type (cylindrical, 8.43° ± 3.26° vs. tapered, 8.07 ± 3.51°; p = 0.637), obesity, or surgical position parameters.
Conclusions
Freehand pedicle screw placement consistently produces trajectory deviations from pilot holes, and surgeon experience and tapping are modifiable protective factors. The IMU-based tracking system enables quantitative surgical motion analysis, suggesting its utility for training optimization and technique standardization.
9.Relationship of gross motor skills and perceptual motor abilities with physical activity levels in preschoolers
LI Yameng, ZHU Xiaotong, SHAO Tianzeng, YUE Fengshan, REN Yiqi, REN Yuanchun
Chinese Journal of School Health 2026;47(1):104-108
Objective:
To analyze the relationship of gross motor skills and perceptual motor abilities with physical activity levels in preschool children in a Beijing kindergarten, so as to provide a reference for promoting the development of motor competence.
Methods:
From September 2018 to March 2021, preschoolers aged 4-5 years were selected using convenience sampling method from an urban kindergarten in Beijing. The Test of Gross Motor Development-Third Version(TGMD-3) was used to assess basic preschoolers s gross motor skills ( n =152). The Pictorial Scale of Perceived Movement Skill Competence(PMSC) was used to evaluate perceptual motor skills ( n =151). Accelerometers (Actigraph GT3X) were used to record physical activity levels ( n =52). Data were analyzed using one way analysis of variance (ANOVA) and Pearson correlation coefficients.
Results:
The mean scores for gross motor skills and perceptual motor abilities were (38.76±13.48) and (35.49±6.50), respectively. The moderate to vigorous physical activity(MVPA) level was(52.60±27.44) minutes per day. No statistically significant correlations were found between gross motor skills, perceptual motor abilities MVPA among boys, girls or the overall group ( r =-0.20 to 0.25, all P >0.05). However, Boys locomotor skills, overall children s locomotor skills, and boys gross motor skills were all positively correlated with MVPA( r =0.34-0.45, all P <0.05).
Conclusion
There is a correlation between locomotor skills and physical activity levels in 4 to 5-year-old children.
10.Clinical observation of sacubitril/valsartan versus benazepril in perimenopausal hypertensive patients
Xiaoxia ZHANG ; Bolin SHAO ; Yingkun ZHOU ; Zhanhai ZHANG ; Zhiying LI
China Pharmacy 2026;37(4):476-479
OBJECTIVE To compare the antihypertensive efficacy of sacubitril/valsartan versus benazepril in patients with perimenopausal hypertension, as well as their impacts on ventricular remodeling and inflammatory fibrosis. METHODS A total of 206 perimenopausal hypertensive patients in our hospital from January 1, 2023 to December 30, 2024 were retrospectively included.These patients were enrolled and divided into benazepril group (105 cases) and sacubitril/valsartan group (101 cases). Benazepril group received Benazepril hydrochloride tablet, and sacubitril/valsartan group received Sacubitril valsartan sodium tablet. All patients were treated for 6 months. The blood pressure(systolic blood pressure and diastolic blood pressure) and blood pressure control status before and after treatment, echocardiographic indicators (left ventricular ejection fraction, left ventricular mass index, relative wall thickness, and early-diastolic peak transmitral flow velocity/early-diastolic peak velocity of the mitral annulus), inflammatory fibrosis related indicators(high-sensitivity C-reactive protein,ratio of monocytes to lymphocytes,and ratio of neutrophils to lymphocytes), as well as the occurrence of adverse reactions(hypotension,hyperkalemia,and angioedema) were observed in both groups before and after treatment. RESULTS The blood pressure control rate was significantly higher in the sacubitril/valsartan group than in benazepril group ( P <0.05). After treatment, the blood pressure, echocardiographic indicators(except for left ventricular ejection fraction) ,and inflammatory fibrosis related indicators were significantly lower than those before treatment within the same group, and the sacubitril/valsartan group were significantly lower than the benazepril group ( P <0.05). There were no statistically significant differences in the incidence of hypotension, hyperkalemia, angioedema, and overall adverse drug reactions between the two groups ( P >0.05). CONCLUSIONS Compared with benazepril, sacubitril/valsartan provides superior blood-pressure control, reverses ventricular remodeling, attenuates inflammatory fibrosis in perimenopausal hypertensive patients, while maintaining a similar safety profile.