1.Association Between Selvester QRS Score and Myocardial Fibrosis in Patients With Hypertrophic Cardiomyopathy
Baojing SUN ; Juan WANG ; Xiaoliang LUO ; Haobo XU ; Dong LIU ; Hanyang LIANG ; Jiansong YUAN ; Shubin QIAO
Chinese Circulation Journal 2025;40(11):1103-1110
Objectives:The aim of this study was to investigate the value of assessing Selvester QRS score in evaluating myocardial fibrosis in hypertrophic cardiomyopathy(HCM)patients.Methods:A total of consecutive 149 patients with HCM,who were admitted in Fuwai Hospital from October 2008 to September 2013,were enrolled in this study.Qualitative and quantitative analyses of myocardial fibrosis were conducted based on late gadolinium enhancement(LGE)derived from enhanced cardiac magnetic resonance imaging(CMR).According to the qualitative analysis of myocardial fibrosis by CMR-LGE,the patients were divided into the LGE-negative group(n=46)and the LGE-positive group(n=103).Standard 12-lead electrocardiogram examination was performed and the Selvester QRS score was calculated.Multivariate binary Logistic regression analysis was used to analyze the predictive factors of positive LGE,and the correlation analysis between the Selvester QRS score and the LGE score was also performed.Results:Compared with the LGE-negative group,the proportion of patients with a family history of HCM(12.8%vs.28.2%),the proportion of patients with a positive Selvester QRS score(65.2%vs.83.5%)and the Selvester QRS score([1.65±1.81]points vs.[5.71±3.80]points)were higher,the maximum thickness of the left ventricular wall([20.5±3.2]mm vs.[24.5±5.0]mm)and the percentage of left ventricular myocardial scar area([5.0±5.5]%vs.[17.1±11.4]%)were larger in the LGE-positive group(all P<0.05).Multivariate binary logistic regression analysis showed that the Selvester QRS score(OR=1.429,95%CI:1.128-1.802,P=0.003)and the maximum left ventricular wall thickness(OR=1.257,95%CI:1.029-1.537,P=0.025)were independent predictors of positive LGE.Pearson correlation analysis showed that in all HCM patients,the Selvester QRS score was positively correlated with the LGE score(r=0.682,P<0.001),and the percentage of left ventricular myocardial scar area was positively correlated with the percentage of enhanced area to the total mass of left ventricular myocardium(LGE%)(r=0.682,P<0.001);In the LGE positive group,the Selvester QRS score was positively correlated with the LGE score(r=0.569,P<0.001).Receiver operating characteristic(ROC)curve analysis showed that the optimal cut-off values of Selvester QRS score and maximum left ventricular wall thickness for predicting positive LGE were≥3.5 points and≥21 mm,respectively.Conclusions:In HCM patients,the Selvester QRS score is significantly associated with myocardial fibrosis,and the total score≥3.5 serves as a good predictive cutoffvalue for identifying the presence of LGE.
2.Study of the dose advantage of 3D printed applicator in postoperative brachytherapy for endometrial cancer
Yunfeng GUO ; Xiaoliang LIANG ; Siyang LIU ; Yuan CAO ; Wei GAO ; Xiaomei FAN
Chinese Journal of Radiation Oncology 2025;34(10):1008-1013
Objective:To compare the dosimetric differences between a 3D-printed non-coplanar multi-channel applicator and traditional single-channel/co-planar multi-channel applicators in postoperative vaginal brachytherapy for early-stage endometrial cancer.Methods:CT scan data of 66 patients with stage I endometrial cancer, encompassing 100 3D brachytherapy CT imaging datasets, admitted to Department of Gynecologic Oncology of the Fourth Hospital of Hebei Medical University from December 2021 to June 2024 were retrospectively analyzed. Based on CT images and delineated structures, offline reconstructions of radiotherapy plans were performed for single-channel, coplanar multi-channel, and 3D-printed non-coplanar multi-channel applicators. These 3 radiotherapy plans were optimized, and the high-risk clinical target volume (HR-CTV) coverage (V 100 ≥90%) and doses to organs at risk (rectum, bladder) were compared. The prescription dose was standardized at 600 cGy, with constraints of rectal D 2 cm3 ≤420 cGy and bladder D 2 cm3 ≤480 cGy. Comparison among multiple groups was conducted by ANOVA. Bonferroni method was used to correct P-values for comparison between two groups. Results:When defined as HR-CTV D 90%≥600 cGy, bladder D 2 cm3 was (398.29±76.13)cGy and rectum D 2 cm3 was (402.10±49.77)cGy of the 3D-printed non-coplanar multi-channel group,which were significantly lower than those in the single-channel group [bladder D 2 cm3 (424.09±131.52) cGy, rectum D 2 cm3 (493.11±115.17) cGy] and coplanar group [bladder D 2 cm3 (461.28±134.84) cGy, rectum D 2 cm3 (508.75±119.02) cGy], respectively. When limiting bladder D 2 cm3≤480 cGy, rectal D 2 cm3 was (446.81±78.53 cGy) of the 3D-printed non-coplanar multi-channel group, which was significantly lower than those in the single-channel group [(589.71±153.91) cGy] and the coplanar group [(545.51±122.00) cGy], respectively. Meanwhile, HR-CTV V 100% (94.53%±3.42%) was higher than (91.19%±7.63%) in the coplanar group. When the rectal D 2 cm3 was ≤ 420 cGy, HR-CTV V 100% was (91.92%±4.04%) of the 3D-printed non-coplanar multi-channel group,which was significantly better than (79.23%±13.95%) in the single-channel group and (85.88%±6.86%) in the coplanar group, respectively. Conclusions:The 3D-printed non-coplanar multi-channel applicator significantly reduces bladder and rectal doses while enhancing target coverage, outperforming traditional single-channel and co-planar multi-channel applicators. This innovation provides an optimized solution for individualized precision radiotherapy.
3.Association Between Selvester QRS Score and Myocardial Fibrosis in Patients With Hypertrophic Cardiomyopathy
Baojing SUN ; Juan WANG ; Xiaoliang LUO ; Haobo XU ; Dong LIU ; Hanyang LIANG ; Jiansong YUAN ; Shubin QIAO
Chinese Circulation Journal 2025;40(11):1103-1110
Objectives:The aim of this study was to investigate the value of assessing Selvester QRS score in evaluating myocardial fibrosis in hypertrophic cardiomyopathy(HCM)patients.Methods:A total of consecutive 149 patients with HCM,who were admitted in Fuwai Hospital from October 2008 to September 2013,were enrolled in this study.Qualitative and quantitative analyses of myocardial fibrosis were conducted based on late gadolinium enhancement(LGE)derived from enhanced cardiac magnetic resonance imaging(CMR).According to the qualitative analysis of myocardial fibrosis by CMR-LGE,the patients were divided into the LGE-negative group(n=46)and the LGE-positive group(n=103).Standard 12-lead electrocardiogram examination was performed and the Selvester QRS score was calculated.Multivariate binary Logistic regression analysis was used to analyze the predictive factors of positive LGE,and the correlation analysis between the Selvester QRS score and the LGE score was also performed.Results:Compared with the LGE-negative group,the proportion of patients with a family history of HCM(12.8%vs.28.2%),the proportion of patients with a positive Selvester QRS score(65.2%vs.83.5%)and the Selvester QRS score([1.65±1.81]points vs.[5.71±3.80]points)were higher,the maximum thickness of the left ventricular wall([20.5±3.2]mm vs.[24.5±5.0]mm)and the percentage of left ventricular myocardial scar area([5.0±5.5]%vs.[17.1±11.4]%)were larger in the LGE-positive group(all P<0.05).Multivariate binary logistic regression analysis showed that the Selvester QRS score(OR=1.429,95%CI:1.128-1.802,P=0.003)and the maximum left ventricular wall thickness(OR=1.257,95%CI:1.029-1.537,P=0.025)were independent predictors of positive LGE.Pearson correlation analysis showed that in all HCM patients,the Selvester QRS score was positively correlated with the LGE score(r=0.682,P<0.001),and the percentage of left ventricular myocardial scar area was positively correlated with the percentage of enhanced area to the total mass of left ventricular myocardium(LGE%)(r=0.682,P<0.001);In the LGE positive group,the Selvester QRS score was positively correlated with the LGE score(r=0.569,P<0.001).Receiver operating characteristic(ROC)curve analysis showed that the optimal cut-off values of Selvester QRS score and maximum left ventricular wall thickness for predicting positive LGE were≥3.5 points and≥21 mm,respectively.Conclusions:In HCM patients,the Selvester QRS score is significantly associated with myocardial fibrosis,and the total score≥3.5 serves as a good predictive cutoffvalue for identifying the presence of LGE.
4.Study of the dose advantage of 3D printed applicator in postoperative brachytherapy for endometrial cancer
Yunfeng GUO ; Xiaoliang LIANG ; Siyang LIU ; Yuan CAO ; Wei GAO ; Xiaomei FAN
Chinese Journal of Radiation Oncology 2025;34(10):1008-1013
Objective:To compare the dosimetric differences between a 3D-printed non-coplanar multi-channel applicator and traditional single-channel/co-planar multi-channel applicators in postoperative vaginal brachytherapy for early-stage endometrial cancer.Methods:CT scan data of 66 patients with stage I endometrial cancer, encompassing 100 3D brachytherapy CT imaging datasets, admitted to Department of Gynecologic Oncology of the Fourth Hospital of Hebei Medical University from December 2021 to June 2024 were retrospectively analyzed. Based on CT images and delineated structures, offline reconstructions of radiotherapy plans were performed for single-channel, coplanar multi-channel, and 3D-printed non-coplanar multi-channel applicators. These 3 radiotherapy plans were optimized, and the high-risk clinical target volume (HR-CTV) coverage (V 100 ≥90%) and doses to organs at risk (rectum, bladder) were compared. The prescription dose was standardized at 600 cGy, with constraints of rectal D 2 cm3 ≤420 cGy and bladder D 2 cm3 ≤480 cGy. Comparison among multiple groups was conducted by ANOVA. Bonferroni method was used to correct P-values for comparison between two groups. Results:When defined as HR-CTV D 90%≥600 cGy, bladder D 2 cm3 was (398.29±76.13)cGy and rectum D 2 cm3 was (402.10±49.77)cGy of the 3D-printed non-coplanar multi-channel group,which were significantly lower than those in the single-channel group [bladder D 2 cm3 (424.09±131.52) cGy, rectum D 2 cm3 (493.11±115.17) cGy] and coplanar group [bladder D 2 cm3 (461.28±134.84) cGy, rectum D 2 cm3 (508.75±119.02) cGy], respectively. When limiting bladder D 2 cm3≤480 cGy, rectal D 2 cm3 was (446.81±78.53 cGy) of the 3D-printed non-coplanar multi-channel group, which was significantly lower than those in the single-channel group [(589.71±153.91) cGy] and the coplanar group [(545.51±122.00) cGy], respectively. Meanwhile, HR-CTV V 100% (94.53%±3.42%) was higher than (91.19%±7.63%) in the coplanar group. When the rectal D 2 cm3 was ≤ 420 cGy, HR-CTV V 100% was (91.92%±4.04%) of the 3D-printed non-coplanar multi-channel group,which was significantly better than (79.23%±13.95%) in the single-channel group and (85.88%±6.86%) in the coplanar group, respectively. Conclusions:The 3D-printed non-coplanar multi-channel applicator significantly reduces bladder and rectal doses while enhancing target coverage, outperforming traditional single-channel and co-planar multi-channel applicators. This innovation provides an optimized solution for individualized precision radiotherapy.
5.The clinical application value of different localization methods in thoracoscopic resection of pulmonary nodules
Shao GAO ; Xiaoliang HAN ; Liang WANG ; Keling YAO ; Jiadong XIA
Journal of Interventional Radiology 2024;33(2):171-175
Objective To compare the clinical application value of medical glue and a new-type medical anchor positioning needle in thoracoscopic resection of pulmonary nodules.Methods A total of 182 patients with pulmonary nodules,who received video-assisted thoracic surgery(VATS)at the Department of Thoracic Surgery of Affiliated Hospital of Shaoxing University of China between January 2020 and December 2022,were enrolled in this study.Preoperative CT-guided localization of the pulmonary nodule was performed in all patients,including medical glue positioning in 89 patients(medical glue group)and anchor needle positioning in 93 patients(anchor needle group).The incidences of pneumothorax and bleeding,the time spent for positioning,the interval between localization and operation,the time spent for operation,and the radiation dose during localization process were recorded and the data were statistically analyzed.Results The success rate of positioning was 100%(93/93)in the anchor needle group and 96.7%(86/89)in the medical glue group.There was no statistically significant difference between the two groups(P>0.05).The incidence of bleeding was 31.2%(29/93)in the anchor needle group and 15.7%(14/89)in the medical glue group,and the difference between the two groups was statistically significant(P<0.05).The incidence of pneumothorax was 30.1%(28/93)in the anchor needle group and 20.2%(18/89)in the medical glue group,and there was no significant difference between the two groups(P>0.05).No statistically significant difference in the time spent for operation existed between the two groups(P>0.05).The time spent for positioning and the interval between localization and operation in the medical glue group were longer than those in the anchor needle group,and the radiation dose in the medical glue group was higher than that in the anchor needle group,and the differences between the two groups were statistically significant(P<0.05).Conclusion For the preoperative localization of ground glass opacity(GGO)or solitary pulmonary nodule(SPN),both medical glue positioning method and anchor needle positioning method have high clinical application value.The clinical and interventional physicians should adopt appropriate positioning method according to the patient's condition.
6.A national questionnaire survey on endoscopic treatment for gastroesophageal varices in portal hypertension in China
Xing WANG ; Bing HU ; Yiling LI ; Zhijie FENG ; Yanjing GAO ; Zhining FAN ; Feng JI ; Bingrong LIU ; Jinhai WANG ; Wenhui ZHANG ; Tong DANG ; Hong XU ; Derun KONG ; Lili YUAN ; Liangbi XU ; Shengjuan HU ; Liangzhi WEN ; Ping YAO ; Yunxiao LIANG ; Xiaodong ZHOU ; Huiling XIANG ; Xiaowei LIU ; Xiaoquan HUANG ; Yinglei MIAO ; Xiaoliang ZHU ; De'an TIAN ; Feihu BAI ; Jitao SONG ; Ligang CHEN ; Yingcai MA ; Yifei HUANG ; Bin WU ; Xiaolong QI
Chinese Journal of Digestive Endoscopy 2024;41(1):43-51
Objective:To investigate the current status of endoscopic treatment for gastroesophageal varices in portal hypertension in China, and to provide supporting data and reference for the development of endoscopic treatment.Methods:In this study, initiated by the Liver Health Consortium in China (CHESS), a questionnaire was designed and distributed online to investigate the basic condition of endoscopic treatment for gastroesophageal varices in portal hypertension in 2022 in China. Questions included annual number and indication of endoscopic procedures, adherence to guideline for preventing esophagogastric variceal bleeding (EGVB), management and timing of emergent EGVB, management of gastric and isolated varices, and improvement of endoscopic treatment. Proportions of hospitals concerning therapeutic choices to all participant hospitals were calculated. Guideline adherence between secondary and tertiary hospitals were compared by using Chi-square test.Results:A total of 836 hospitals from 31 provinces (anotomous regions and municipalities) participated in the survey. According to the survey, the control of acute EGVB (49.3%, 412/836) and the prevention of recurrent bleeding (38.3%, 320/836) were major indications of endoscopic treatment. For primary [non-selective β-blocker (NSBB) or endoscopic therapies] and secondary prophylaxis (NSBB and endoscopic therapies) of EGVB, adherence to domestic guideline was 72.5% (606/836) and 39.2% (328/836), respectively. There were significant differences in the adherence between secondary and tertiary hospitals in primary prophylaxis of EGVB [71.0% (495/697) VS 79.9% (111/139), χ2=4.11, P=0.033] and secondary prophylaxis of EGVB [41.6% (290/697) VS 27.3% (38/139), χ2=9.31, P=0.002]. A total of 78.2% (654/836) hospitals preferred endoscopic therapies treating acute EGVB, and endoscopic therapy was more likely to be the first choice for treating acute EGVB in tertiary hospitals (82.6%, 576/697) than secondary hospitals [56.1% (78/139), χ2=46.33, P<0.001]. The optimal timing was usually within 12 hours (48.5%, 317/654) and 12-24 hours (36.9%, 241/654) after the bleeding. Regarding the management of gastroesophageal varices type 2 and isolated gastric varices type 1, most hospitals used cyanoacrylate injection in combination with sclerotherapy [48.2% (403/836) and 29.9% (250/836), respectively], but substantial proportions of hospitals preferred clip-assisted therapies [12.4% (104/836) and 26.4% (221/836), respectively]. Improving the skills of endoscopic doctors (84.2%, 704/836), and enhancing the precision of pre-procedure evaluation and quality of multidisciplinary team (78.9%, 660/836) were considered urgent needs in the development of endoscopic treatment. Conclusion:A variety of endoscopic treatments for gastroesophageal varices in portal hypertension are implemented nationwide. Participant hospitals are active to perform emergent endoscopy for acute EGVB, but are inadequate in following recommendations regarding primary and secondary prophylaxis of EGVB. Moreover, the selection of endoscopic procedures for gastric varices differs greatly among hospitals.
7.Analysis of the characteristics of infectious pathogens in burn patients with sepsis based on metagenomic next-generation sequencing technology
Jijing SHI ; Liang ZHAO ; Xiaoliang LI ; Qun ZHANG ; Chengde XIA ; Chao MA
Chinese Journal of Burns 2024;40(10):940-947
Objective:To analyze the characteristics of infectious pathogens in burn patients with sepsis based on metagenomic next-generation sequencing (mNGS) technology.Methods:This study was a retrospective observational study. From July 2021 to December 2023, 109 burn patients with sepsis who met the inclusion criteria were admitted to the Department of Burns of the First People's Hospital of Zhengzhou, including 68 males aged 57 to 92 years and 41 females aged 48 to 83 years. Blood, bronchoalveolar lavage fluid, cerebrospinal fluid, sputum, or other fluid specimens were collected from the patients during their hospital stay for microbiological culture (86 patients) and mNGS technology detection (109 patients). The types of specimens and pathogens detected by mNGS technology were counted. Patients were divided into intensive care unit (ICU) group (78 cases) who were admitted to the ICU and non-ICU group (31 cases) who were not admitted to the ICU, and the pathogens for infection in the two groups of patients were analyzed. In addition, the detection of pathogens in the specimens of 86 patients who underwent both mNGS technology detection and microbiological culture detection was analyzed.Results:Among the 109 specimens detected by mNGS technology, there were 42 blood specimens, 17 bronchoalveolar lavage fluid specimens, 4 sputum specimens, 6 cerebrospinal fluid specimens, 16 pus specimens, and 24 tissue fluid specimens; a total of 39 pathogens were detected, including 13 bacteria, 12 fungi, 10 viruses, 2 parasites, and 2 mycoplasmas. The overall positive rate of pathogen detection was 88.99% (97/109). Ranked by the detection rate, the top three Gram-negative bacteria were Klebsiella pneumoniae, Acinetobacter baumannii, and Pseudomonas spp, the top three Gram-positive bacteria were Streptococcus pneumoniae, Staphylococcus aureus, and Enterococcus faecalis; the top three viruses were human herpesvirus, cytomegalovirus, and circovirus; the top three fungi were Aspergillus fumigatus, Candida albicans, and Aspergillus flavus. Twenty-seven patients were infected with one pathogen, 45 patients with two pathogens, and 25 patients with three or more pathogens. Compared with those in non-ICU group, the proportions of Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas spp, Streptococcus pneumoniae, Aspergillus fumigatus, and cytomegalovirus detected in the patients in ICU group were significantly higher (with χ2 values of 8.62, 7.93, 3.93, 5.48, 4.28, and 5.58, respectively, P<0.05). In the pathogens detected by mNGS technology and microbiological culture method, the most common bacteria were Klebsiellapneumoniaeand Acinetobacter baumannii, and the most common fungi were strains of Aspergillus and Candida. There were 19 pathogens those could only be detected by mNGS technology, such as Lichtheimia ramosa, Pneumocystis jirovecii, Mycobacterium tuberculosis, viruses, etc.; there were no pathogens detected by microbiological culture method that couldn't be detected by mNGS technology. Compared with those detected by microbiological culture method, the overall positive rate, bacterial positive rate, and fungal positive rate detected by mNGS technology were significantly increased (with χ2 values of 45.52, 5.88, and 4.94, respectively, P<0.05). The 27.91% (24/86) of patients were detected positive by both methods, and 72.09% (62/86) of the patients were detected positive by mNGS technology but negative by microbiological culture method. The consistency test of the results obtained by the two detection methods showed that the difference was not statistically significant ( κ=0.02, P>0.05). Conclusions:The positive rate of pathogen detection in specimens using mNGS technology is higher than that detected by using conventional microbiological culture method, and it can detect pathogens those cannot be detected by the latter, such as Lichtheimia ramosa, Pneumocystis jirovidii, Mycobacterium tuberculosis, viruses, etc. Detection using mNGS technology can help clarify the types of infectious pathogens in burns patients with sepsis, and provide basis and guidance for clinical medication.
8.Determination of MBT in cefazoxime sodium for injection by UPLC-MS-MS and risk analysis of domestic samples
Xiaoliang WANG ; Lihua JIA ; Yawei LIANG ; Binghua ZHANG ; Jianshan WANG
Drug Standards of China 2024;25(6):577-583
Objective:To establish an ultra-high performance liquid chromatography-tandem mass spectrometry(UPLC-MS-MS)method for the determination of 2-mercaptobenzothiazole(MBT)genotoxic impurities in cefazoxime sodium for injection and to analyze the detection of domestic samples from 28 manufacturers.Methods:The UPLC analysis was performed on a Phenomenex Luna Omega C18 column,(2.1 mm × 100 mm,1.6 μm)with the column temperature 30 ℃.The mobile phases A was 2 mmol·L-1 ammonium acetate(contai-ning 0.001%formic acid)and the mobile phase B was acetonitrile with gradient elute.The flow rate was 0.3 mL·min-1.The injection volume was 5 μL.The electrospray ionization(ESI)source in positive mode and multiple reaction monitoring(MRM)were used for the detection of MBT,and external standard method for quanti-tative analysis.Results:The linear relationship of MBT was good in the concentration range of 1.4-58.12 ng·mL-1(r=0.999).The limit of detection was 1.453 pg and the limit of quantification was 7.265 pg.The average recoveries of low,medium and high concentrations were 106.8%,107.1%and 109.0%,respectively with the relative standard deviation(RSD)all less than 2.0%.The relative standard deviation(RSD)of repeatability was less than 6.0%.The content of MBT in the samples from 28 domestic enterprises was all less than 10 ppm,but there were obvious differences in the detected amount among all enterprises which is due to different production processes.Conclusion:The established method can be used for the qualitative and quantitative detection of MBT in cefazoxime sodium for injection and the partical enterprises which have been detected MBT impurities need to further raise the warning.
9.Determination of MBT in cefazoxime sodium for injection by UPLC-MS-MS and risk analysis of domestic samples
Xiaoliang WANG ; Lihua JIA ; Yawei LIANG ; Binghua ZHANG ; Jianshan WANG
Drug Standards of China 2024;25(6):577-583
Objective:To establish an ultra-high performance liquid chromatography-tandem mass spectrometry(UPLC-MS-MS)method for the determination of 2-mercaptobenzothiazole(MBT)genotoxic impurities in cefazoxime sodium for injection and to analyze the detection of domestic samples from 28 manufacturers.Methods:The UPLC analysis was performed on a Phenomenex Luna Omega C18 column,(2.1 mm × 100 mm,1.6 μm)with the column temperature 30 ℃.The mobile phases A was 2 mmol·L-1 ammonium acetate(contai-ning 0.001%formic acid)and the mobile phase B was acetonitrile with gradient elute.The flow rate was 0.3 mL·min-1.The injection volume was 5 μL.The electrospray ionization(ESI)source in positive mode and multiple reaction monitoring(MRM)were used for the detection of MBT,and external standard method for quanti-tative analysis.Results:The linear relationship of MBT was good in the concentration range of 1.4-58.12 ng·mL-1(r=0.999).The limit of detection was 1.453 pg and the limit of quantification was 7.265 pg.The average recoveries of low,medium and high concentrations were 106.8%,107.1%and 109.0%,respectively with the relative standard deviation(RSD)all less than 2.0%.The relative standard deviation(RSD)of repeatability was less than 6.0%.The content of MBT in the samples from 28 domestic enterprises was all less than 10 ppm,but there were obvious differences in the detected amount among all enterprises which is due to different production processes.Conclusion:The established method can be used for the qualitative and quantitative detection of MBT in cefazoxime sodium for injection and the partical enterprises which have been detected MBT impurities need to further raise the warning.
10.Exploration of cognitive inhibitory function in negation and color-word Stroop task of patients with schizophrenia
Qiangwei YU ; Zhihua GAO ; Xiaoliang LIANG ; Shenghang HOU ; Yang BAI
Chinese Journal of Behavioral Medicine and Brain Science 2023;32(10):915-922
Objective:To explore the impact of negation effect on color judgment of the color-word pairs and the impairment of cognitive inhibition function of the patients with schizophrenia (SCH) through embedding negation into the Stroop task.Methods:From January to December 2021, " Affirmative/ negative + color words" as the experimental materials, classical Stroop paradigm as the experimental paradigm, a mixed experimental design of 2 (groups: the SCH group vs the normal control group)×2(phrase polarity: affirmative phrases vs negative phrases)×2 (word-color congruence: consistency vs inconsistency) was designed to explore the inhibition function of negative phrases of the SCHs under bipolar negation conditions (Experiment 1) and multi-polar negation conditions (Experiment 2) respectively. The schizophrenic patients in Experiment 1(28 patients and 28 normal controls) and Experiment 2(30 patients and 30 normal controls) were sampled from the inpatients of Tangshan Kailuan Mental Health Center and Suzhou Guangji Hospital respectively, and the healthy controls were recruited from the community. SPSS 25.0 software was adopted as statistical analysis, and accuracy, response time of Stroop and the Stroop effect were analyzed by repeated measurement analysis of variance. Results:(1) The group main effects of response time were both significant in bipolar negation conditions(Experiment 1) ( F=49.22, P<0.001, ηp2=0.48) and multi-polar negation conditions (Experiment 2) ( F=37.58, P<0.001, ηp2=0.39). In bipolar negation (Experiment 1) conditions, as for the Stroop effect of response time, there was a significant interaction between the groups and polarities( F=4.42, P<0.05, ηp2=0.08), and there was a statistically significant difference between the affirmative Stroop effect (-0.137±0.522)and the negative Stroop effect(0.082±0.169) in the schizophrenia group( F=7.15, P<0.05, ηp2=0.12). In multi-polar negation conditions (Experiment 2), there was a marginal significant of the interaction between Stroop conditions and polarities in accuracy( F=3.81, P=0.056, ηp2=0.06). The accuracy under the word color consistency condition was higher than that under inconsistency condition((96.51±1.55)%, (90.00±2.54)%) ( F=5.15, P<0.05, ηp2=0.08). (3)In bipolar negation (Experiment 1) conditions, as for the accuracy, the interaction among groups, word color consistencies, and polarities was significant( F=6.66, P<0.05, ηp2=0.11). The interaction between word color consistencies and polarities was significant in the schizophrenia group( F=9.16, P<0.05, ηp2=0.15). In the normal group, the interaction between Stroop conditions and polarities was not significant( P>0.05). Conclusion:The impairment of cognitive inhibition function in schizophrenia is severe, which is reflected in negative processing; negation functions as cognitive inhibition, which is particularly prominent in bipolar negation.

Result Analysis
Print
Save
E-mail