1.Serum nitric oxide synthase 4 and matrix metalloproteinase-2 expression in patients with diabetic neovascular glaucoma and their clinical significance
Xiaomin LIU ; Jingfei BAN ; Jing LYU ; Wenwen LI ; Jingke LI ; Shunling YANG
International Eye Science 2026;26(1):103-108
AIM: To investigate and analyze serum nitric oxide synthase 4(NOX4)and matrix metalloproteinase(MMP)-2 expressions in patients with diabetes mellitus(DM)complicated with neovascular glaucoma(NVG)and their clinical significance.METHODS: A prospective study was conducted on 161 patients with DM complicated with NVG admitted to Handan City Eye Hospital(The Third Hospital of Handan)from June 2020 to June 2023. Based on whether complications occurred 1 a after trabeculectomy in the study group patients, they were divided into a group with good prognosis(n=90)and a group with poor prognosis(n=71). During the same period, 161 patients with chronic angle-closure glaucoma without iris neovascularization were selected as the control group. ELISA method was applied to detect the expression levels of serum NOX4 and MMP-2. ROC curve was plotted to evaluate the diagnostic value and postoperative complication prediction value of NOX4 and MMP-2 in patients with DM complicated with NVG. Pearson method was applied to analyze the correlation of NOX4 and MMP-2 with vascular endothelial growth factor(VEGF)and interleukin-6(IL-6). Multivariate Logistic regression was applied to analyze the influencing factors of postoperative complications in the study group.RESULTS:The general information of the study group and control group of patients is comparable. Compared with the control group, the expression levels of serum NOX4, MMP-2, VEGF, and IL-6 in the study group were significantly increased(P<0.001). According to Pearson analysis, serum NOX4 and MMP-2 levels significantly positively correlated with VEGF and IL-6 levels, respectively(P<0.001). According to ROC curve, the AUC of NOX4 combined with MMP-2 in the diagnosis of DM complicated with NVG was better than that of individual diagnosis of NOX4(Z=3.341, P<0.05)and MMP-2(Z=2.788, P<0.05). The duration of DM, the proportion of people with intraocular pressure >21 mmHg, and the expression levels of NOX4, MMP-2, VEGF, and IL-6 in the poor prognosis group were all higher than those in the good prognosis group(P<0.001). The duration of DM, intraocular pressure >21 mmHg, the levels of NOX4, MMP-2, VEGF, and IL-6 were all risk factors for poor prognosis in DM patients with NVG(P<0.001). According to ROC curve, the combined prediction of NOX4 and MMP-2 for postoperative complications in patients with DM complicated by NVG was superior to the AUC predicted by NOX4(Z=3.727, P<0.05)and MMP-2(Z=2.219, P<0.05), respectively.CONCLUSION:NOX4 and MMP-2 are upregulated in the serum of patients with DM complicated by NVG. Combined detection of these two markers holds significant clinical value for the early diagnosis and prognosis of patients with DM complicated by NVG.
2.Preventive effect of LifePort combined with polymyxin B on donor-derived infections in kidney transplantation
Xiaomin LI ; Yuewei YIN ; Chenming ZHAO ; Yalin NIU ; Kailong LIU ; Pingying GUO ; Wei LI ; Baosai LU
Organ Transplantation 2026;17(2):227-234
Objective To evaluate the effect of LifePort combined with polymyxin B in preventing donor-derived infections caused by preservation solution contamination. Methods Clinical data of 110 kidney transplant recipients were retrospectively analyzed. According to the decontamination status of preservation solution, the recipients were divided into the decontamination group (n=62) and the non-decontamination group (n=48). The general data of the two groups were compared, and the preventive effect of polymyxin B on possible donor-derived infections (p-DDI) was analyzed, especially infections associated with multidrug-resistant Gram-negative bacteria (MDR GNB). Results There were no statistically significant differences in baseline data (gender, age, preservation solution contamination status, etc.) between the decontamination group and the non-decontamination group (all P > 0.05). The overall contamination rate of preservation solution was 80.0%, and 68 contaminated samples were with single microorganism and 20 with multiple microorganisms. Coagulase-negative staphylococci, Enterococcus and Klebsiella pneumoniae were the most common microorganisms in the positive samples. Fifteen cases of preservation solution were contaminated by MDR GNB, including 10 cases in the non-decontamination group and 5 cases in the decontamination group, with no statistically significant difference between the two groups (P = 0.053). Postoperative infection-related events occurred in 69 recipients, including 39 cases in the non-decontamination group and 30 cases in the decontamination group, with the incidence rate in the non-decontamination group significantly higher than that in the decontamination group (P < 0.001). Only 10 cases of infections were identified as p-DDI, all of which were positive for preservation solution culture, including 8 cases in the non-decontamination group and 2 cases in the decontamination group (P < 0.05). There were 5 cases of p-DDI related to MDR GNB in the non-decontamination group, while no such cases occurred in the decontamination group (P < 0.05). No adverse reactions related to polymyxin B were observed, and no recipient death or renal allograft dysfunction occurred in either group. Conclusions Adding polymyxin B to the preservation fluid during hypothermic machine perfusion with LifePort before renal transplantation may reduce p-DDI and its potential adverse consequences.
3.Ethical challenges and countermeasures of generative artificial intelligence in medical informed consent: a case study of Chat Generative Pre-trained Transformer
Yongqi REN ; Mengyuan LI ; Xing LIU ; Xiaomin WANG
Chinese Medical Ethics 2026;39(3):307-313
Informed consent constitutes a fundamental ethical principle in medical practice. With the in-depth integration of generative artificial intelligence (AI) represented by Chat Generative Pre-trained Transformer (ChatGPT) with medicine, it has brought revolutionary development to traditional informed consent while also introducing new ethical challenges. ChatGPT offers features such as improving the readability of informed consent content, enhancing its comprehensiveness and accuracy, and increasing the convenience of obtaining informed consent. However, as the application of ChatGPT in informed consent is still in the exploratory stage, it is imperative to proactively and fully consider the accompanying ethical issues, such as information security, liability determination, transparency, and fairness. This paper conducted an ethical analysis on the challenges faced by generative AI, represented by ChatGPT, in the application of informed consent and proposed countermeasures, such as upholding free and fully informed consent, strengthening the balance of rights and obligations in informed consent, and establishing a transparent and fair supervision mechanism. The aim was to promote the ethically compliant, orderly, and controllable development of generative AI in the field of medical informed consent.
4.High tibial osteotomy on a single plane:femorofibular angle as a reference marker for mechanical axis correction
Xiaomin LI ; Xiangdong TIAN ; Chaolu WANG
Chinese Journal of Tissue Engineering Research 2026;30(3):570-576
BACKGROUND:The femorofibular angle is a commonly used reference angle for mechanical axis correction in high tibial osteotomy on a single plane,but there has been no in-depth study on the application of this angle in high tibial osteotomy on a single plane.OBJECTIVE:To explore the application effect of the femorofibular angle as a reference for mechanical axis correction in high tibial osteotomy on a single plane.METHODS:A retrospective analysis was conducted on 64 cases of knee osteoarthritis patients who underwent high tibial osteotomy on a single plane at Third Affiliated Hospital of Beijing University of Chinese Medicine from January 2023 to January 2024.The patients were grouped according to the intraoperative mechanical axis correction reference method.The observation group consisted of 32 cases,which used the femorofibular angle as a reference for mechanical axis correction during surgery.The control group consisted of 32 cases,which used electrocautery line measurement as a reference for mechanical axis correction during surgery.Both groups received the same perioperative treatment and management.The lower limb mechanical axis ratio,hip-knee-ankle angle,proximal medial tibial angle,and femorofibular angle were recorded before and after surgery to assess changes in the lower limb mechanical state.The operation time and number of fluoroscopies were recorded.The visual analog scale score and Lysholm score for pain and knee function were recorded before surgery and at 1 and 3 months after surgery to evaluate changes in knee pain and function.RESULTS AND CONCLUSION:(1)All patients completed the treatment and follow-up,and no serious adverse events occurred.(2)Before surgery,there was no statistically significant difference in the lower limb mechanical axis ratio,proximal medial tibial angle,hip-knee-ankle angle,and femorofibular angle between the two groups(P>0.05).At 3 months after surgery,the lower limb mechanical axis ratio,proximal medial tibial angle,hip-knee-ankle angle,and femorofibular angle were significantly improved in both groups compared to before surgery,with statistically significant differences(P<0.05).There was no significant difference between the two groups(P>0.05).(3)During surgery,the operation time and number of fluoroscopies in the observation group were less than those in the control group,with statistically significant differences(P<0.05).(4)At each follow-up point before and after surgery,there was no statistically significant difference in the visual analog scale score and Lysholm score between the two groups(P>0.05).With the passage of time after surgery,the visual analog scale score and Lysholm score in both groups were significantly improved compared to before surgery(P<0.05).(5)It is suggested that the application of the femorofibular angle as a reference for mechanical axis correction in high tibial osteotomy on a single plane can accurately locate the range of lower limb mechanical axis correction,is simple and reliable,and reduces the number of fluoroscopies and operation time compared to traditional electrocautery line measurement.
5.High tibial osteotomy on a single plane:femorofibular angle as a reference marker for mechanical axis correction
Xiaomin LI ; Xiangdong TIAN ; Chaolu WANG
Chinese Journal of Tissue Engineering Research 2026;30(3):570-576
BACKGROUND:The femorofibular angle is a commonly used reference angle for mechanical axis correction in high tibial osteotomy on a single plane,but there has been no in-depth study on the application of this angle in high tibial osteotomy on a single plane.OBJECTIVE:To explore the application effect of the femorofibular angle as a reference for mechanical axis correction in high tibial osteotomy on a single plane.METHODS:A retrospective analysis was conducted on 64 cases of knee osteoarthritis patients who underwent high tibial osteotomy on a single plane at Third Affiliated Hospital of Beijing University of Chinese Medicine from January 2023 to January 2024.The patients were grouped according to the intraoperative mechanical axis correction reference method.The observation group consisted of 32 cases,which used the femorofibular angle as a reference for mechanical axis correction during surgery.The control group consisted of 32 cases,which used electrocautery line measurement as a reference for mechanical axis correction during surgery.Both groups received the same perioperative treatment and management.The lower limb mechanical axis ratio,hip-knee-ankle angle,proximal medial tibial angle,and femorofibular angle were recorded before and after surgery to assess changes in the lower limb mechanical state.The operation time and number of fluoroscopies were recorded.The visual analog scale score and Lysholm score for pain and knee function were recorded before surgery and at 1 and 3 months after surgery to evaluate changes in knee pain and function.RESULTS AND CONCLUSION:(1)All patients completed the treatment and follow-up,and no serious adverse events occurred.(2)Before surgery,there was no statistically significant difference in the lower limb mechanical axis ratio,proximal medial tibial angle,hip-knee-ankle angle,and femorofibular angle between the two groups(P>0.05).At 3 months after surgery,the lower limb mechanical axis ratio,proximal medial tibial angle,hip-knee-ankle angle,and femorofibular angle were significantly improved in both groups compared to before surgery,with statistically significant differences(P<0.05).There was no significant difference between the two groups(P>0.05).(3)During surgery,the operation time and number of fluoroscopies in the observation group were less than those in the control group,with statistically significant differences(P<0.05).(4)At each follow-up point before and after surgery,there was no statistically significant difference in the visual analog scale score and Lysholm score between the two groups(P>0.05).With the passage of time after surgery,the visual analog scale score and Lysholm score in both groups were significantly improved compared to before surgery(P<0.05).(5)It is suggested that the application of the femorofibular angle as a reference for mechanical axis correction in high tibial osteotomy on a single plane can accurately locate the range of lower limb mechanical axis correction,is simple and reliable,and reduces the number of fluoroscopies and operation time compared to traditional electrocautery line measurement.
6.Role of PI3K/Akt Pathway in Epirubicin Resistance in Triple-Negative Breast Cancer Explored Through Transcriptomic Analysis
Lingshan NAN ; Xiaomin WANG ; Xi ZUO ; Haiming LI ; Dong CHEN ; Xiaohui YIN ; Ganlin ZHANG
Cancer Research on Prevention and Treatment 2026;53(5):339-348
Objective To establish an epirubicin (EPI)-resistant murine triple-negative breast cancer (TNBC) (4T1/EPI) cell line and evaluate its biological characteristics and drug resistance. Methods The EPI-resistant cell line 4T1/EPI was developed through intermittent induction with gradually increasing EPI concentrations in vitro. Morphological changes were observed under an inverted microscope. Drug resistance index (MTT assay), cell doubling time (CCK-8 assay), and migration ability (wound healing assay) were evaluated. Western blot was used to detect the expression of drug resistance-related proteins. Transcriptome sequencing and KEGG pathway enrichment analysis were performed to identify the pathways and targets involved in EPI resistance, followed by experimental validation. Results The 4T1 cells eventually grew normally in a medium containing 100 ng/mL EPI, confirming the establishment of the 4T1/EPI resistant cell line. After stable resistance was acquired, morphological alterations were observed. Compared with their parental 4T1 cells, 4T1/EPI cells showed significantly prolonged doubling time (P<0.01) and enhanced migration ability (P<0.05). Expression levels of drug resistance-related proteins MDR1, MRP1 (P<0.01), and ABCG2 (P<0.05) were elevated in 4T1/EPI cells. In vivo models also demonstrated significant EPI resistance in 4T1/EPI tumors in terms of tumor weight and volume. Transcriptome sequencing highlighted the involvement of the PI3K/Akt signaling pathway and ABC transporter pathway. Validation experiments showed the upregulation of Erbb3, Egfr, PI3K, and Akt (P<0.05) and significant downregulation of Fgfr1 (P<0.01) in 4T1/EPI cells. Conclusion The EPI-resistant TNBC cell line 4T1/EPI was successfully established, exhibiting significant resistance in vitro and in vivo. The mechanism may involve the EPI-induced upregulation of Egfr and Erbb3, activating the PI3K/Akt pathway and subsequently enhancing ABC transporter expression.
7.Optimization strategy of inpatient pharmacy “internet-based medicine delivery”management model based on SWOT analysis
Jing XIE ; Shupei LI ; Shijia LIU ; Xiaomin WANG
China Pharmacy 2026;37(10):1346-1351
OBJECTIVE To address the management challenges encountered by inpatient pharmacy of our hospital in undertaking “internet-based medicine delivery” (IMD) services, and to improve service efficiency and medication safety. METHODS SWOT analysis method was applied to systematically examine both internal and external factors, formulate comprehensive management strategies, and restructure the service processes. Process optimization included: establishing a closed-loop process for dispensing and returning drugs based on the drug traceability codes; unifying the drug inventory of the inpatient pharmacy with that of IMD, optimizing the management of storage locations; improving the inventory management function of the hospital information system, and adjusting the inventory counting plan and shift scheduling rules. The indicators of the inpatient pharmacy, including inventory structure, dispensing efficiency, inventory checks accuracy rate, the rationality rate of prescription, and consistency rate of human-machine review, were compared before and after the implementation of the strategies to evaluate the implementation effects. RESULTS After implementation, the structure of the drug inventory was significantly optimized. The proportion of drugs approaching their expiration dates decreased by 35.55%, the proportion of unsold drugs decreased by 64.52%, and the proportion of drugs that had been accumulated for more than 4 weeks decreased by 33.26%. The speed of prescription dispensing increased by 34.92%, and the daily drug requisition time was shortened by 62.03%. The accuracy rate of inventory checks rose from 86.33% to 90.33%, while the rationality rate of prescriptions and the consistency rate of human-machine review rose from 86.00% and 89.33% to 95.00% and 97.00% respectively. Furthermore, the launch of the drug traceability system reduced external dispensing errors from 4 to 1. CONCLUSIONS The comprehensive management strategy based on SWOT analysis can effectively improve the quality of drug management in the inpatient pharmacy and the operational efficiency of IMD, ensuring timely and safe medication for patients.
8.Comparison of bilateral implantation of extended depth-of-focus intraocular lens and mix-and-match implantation of extended depth-of-focus intraocular lens with a diffractive bifocal intraocular lens
Tong LI ; Zhuoya LI ; Rong GUO ; Xiaomin HU ; Hui ZHANG
International Eye Science 2025;25(3):337-343
AIM: To compare the clinical outcomes of extended depth-of-focus intraocular lenses(EDOF IOLs)using either micromonovision implantation or mixed implantation of EDOF and diffractive bifocal IOLs.METHODS: This retrospective clinical trial included 130 patients(260 eyes), who were divided into two groups. Group RR comprised 70 patients(140 eyes)bilaterally implanted with ZXR00 IOLs(Tecnis ZXR00, where one target was -0.5 D to -0.75 D and the other was 0 to -0.25 D). Group RM comprised 60 patients(120 eyes)unilaterally implanted with both ZXR00 and ZMB00 IOLs(Tecnis ZMB00, 0 to -0.25 D). Postoperative outcomes were compared after 3 mo, including visual acuity, defocus curves, stereoacuity, modulation transfer functions(MTFs), higher-order aberrations, and Visual Function-14(VF-14)questionnaire responses.RESULTS: Group RR had superior bilateral intermediate vision, while the group RM had superior bilateral near vision(both P<0.05). Group RM also exhibited superior MTFs and reduced higher-order aberrations(both P<0.05). Stereoacuity and VF-14 questionnaire results showed no statistically significant difference between groups(P>0.05).CONCLUSION: The implantation of micromonovision has significantly improved near vision. IOLs and their collocation can be customized according to individual patient needs to achieve precise treatment and provide cataract patients with high-quality vision.
9.Comparison of bilateral implantation of extended depth-of-focus intraocular lens and mix-and-match implantation of extended depth-of-focus intraocular lens with a diffractive bifocal intraocular lens
Tong LI ; Zhuoya LI ; Rong GUO ; Xiaomin HU ; Hui ZHANG
International Eye Science 2025;25(3):337-343
AIM: To compare the clinical outcomes of extended depth-of-focus intraocular lenses(EDOF IOLs)using either micromonovision implantation or mixed implantation of EDOF and diffractive bifocal IOLs.METHODS: This retrospective clinical trial included 130 patients(260 eyes), who were divided into two groups. Group RR comprised 70 patients(140 eyes)bilaterally implanted with ZXR00 IOLs(Tecnis ZXR00, where one target was -0.5 D to -0.75 D and the other was 0 to -0.25 D). Group RM comprised 60 patients(120 eyes)unilaterally implanted with both ZXR00 and ZMB00 IOLs(Tecnis ZMB00, 0 to -0.25 D). Postoperative outcomes were compared after 3 mo, including visual acuity, defocus curves, stereoacuity, modulation transfer functions(MTFs), higher-order aberrations, and Visual Function-14(VF-14)questionnaire responses.RESULTS: Group RR had superior bilateral intermediate vision, while the group RM had superior bilateral near vision(both P<0.05). Group RM also exhibited superior MTFs and reduced higher-order aberrations(both P<0.05). Stereoacuity and VF-14 questionnaire results showed no statistically significant difference between groups(P>0.05).CONCLUSION: The implantation of micromonovision has significantly improved near vision. IOLs and their collocation can be customized according to individual patient needs to achieve precise treatment and provide cataract patients with high-quality vision.
10.Cost-effectiveness and return on investment of hepatitis C virus elimination in China: A modelling study
Meiyu WU ; Jing MA ; Xuehong WANG ; Sini LI ; Chongqing TAN ; Ouyang XIE ; Andong LI ; Aaron G LIM ; Xiaomin WAN
Clinical and Molecular Hepatology 2025;31(2):394-408
Background/Aims:
The World Health Organization set the goal of eliminating hepatitis C virus (HCV) by 2030, with 80% and 65% reductions in HCV incidence and mortality rates, respectively. We aimed to evaluate the health benefits, cost-effectiveness and return on investment (ROI) of HCV elimination.
Methods:
Using an HCV transmission compartmental model, we evaluated the benefits and costs of different strategies combining screening and treatment for Chinese populations. We identified strategies to achieve HCV elimination and calculated the incremental cost-effectiveness ratios (ICERs) per disability-adjusted life year (DALY) averted for 2022–2030 to identify the optimal elimination strategy. Furthermore, we estimated the ROI by 2050 by comparing the required investment with the economic productivity gains from reduced HCV incidence and deaths.
Results:
The strategy that results in the most significant health benefits involves conducting annual primary screening at a rate of 14%, re-screening people who inject drugs annually and the general population every five years, and treating 95% of those diagnosed (P14-R4-T95), preventing approximately 5.75 and 0.44 million HCV infections and deaths, respectively, during 2022–2030. At a willingness-to-pay threshold of $12,615, the P14-R4-T95 strategy is the most cost-effective, with an ICER of $5,449/DALY. By 2050, this strategy would have a net benefit of $120,997 million (ROI=0.868).
Conclusions
Achieving HCV elimination in China by 2030 will require significant investment in large-scale universal screening and treatment, but it will yield substantial health and economic benefits and is cost-effective.

Result Analysis
Print
Save
E-mail