1.Exploration of Traditional Chinese Medicine Syndrome Characteristics in A Heart Failure Model Induced by Coronary Artery Ligation Based on Method of Syndrome Identification by Prescription Efficacy
Xiaoqian LIAO ; Peiyao LI ; Xingyu FAN ; Zhenyu ZHAO ; Junyu ZHANG ; Yuehang XU ; Zhixi HU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(5):169-177
Chronic heart failure (CHF) is a major global public health problem, and myocardial infarction is one of its main causes. The mouse model of heart failure induced by coronary artery ligation is widely used in the study of CHF, while the TCM syndrome attributes of this model have not yet been clarified. According to the theory of correspondence between prescriptions and syndromes, the method of syndrome identification by prescription efficacy is an important means of current syndrome research of animal models. This method deduces the syndrome characteristics of animal models through prescription efficacy. Taking the four basic syndrome elements of Qi, blood, Yin and Yang as the classification reference, this study used coronary artery ligation to construct a mouse model of CHF and treated the model with four representative TCM injections with the effects of replenishing Qi, warming Yang, nourishing Yin, and activating blood and enalapril. Echocardiography, tongue color parameters, histopathology, serum N-terminal pro-brain natriuretic peptide (NT-proBNP) and cardiac troponin Ⅰ (cTnⅠ) levels, and systematically explored the TCM syndrome attributes of this model. The results showed that the coronary ligation model presented an obvious cardiac function decline, myocardial fibrosis, infarct size expansion, and purple dark tongue, which were consistent with the basic syndrome characteristics of blood stasis in CHF. Danhong injection had significant effects of improving the cardiac function, alleviating myocardial fibrosis, and reducing serum NT-proBNP and cTnⅠ levels. Huangqi Injection and Shenfu injection can improve the cardiac function and tongue color parameters, with limited effects. The effect of Shenmai injection group was not obvious. This study verifies that the established model conforms to blood stasis syndrome through the method of syndrome identification by prescription efficacy, which provides an experimental basis for the study of TCM syndrome mechanism of CHF.
2.Influencing factors on the prevalence of depressive symptoms among middle school students in Yunnan Province in 2023
Xiaodong MU ; Hong LIU ; Fan YANG ; Tunan LI ; Junyu NI ; Yunjuan YANG
Shanghai Journal of Preventive Medicine 2026;38(2):108-115
ObjectiveTo investigate the epidemiological characteristics and influencing factors of depressive symptoms among middle school (junior, senior, and vocational high school) students in Yunnan Province, China, and to inform evidence-based intervention strategies for adolescent mental health. MethodsA cross-sectional survey was conducted between October and November 2023 using stratified random cluster sampling. Students from eight counties (districts) across four prefectures (cities) in Yunnan Province were included. Depressive symptoms were assessed using the Center for Epidemiologic Studies Depression Scale (CES-D). Multivariate logistic regression analysis was performed to examine factors associated with depressive symptoms, with stratified analyses conducted by gender, educational stage, and ethnicity. ResultsA total of 4 672 questionnaires were distributed, with 4 670 valid questionnaires retrieved, yielding a valid response rate of 99.96%. The surveyed participants were predominantly female students (50.81%), junior high school students (49.13%), ethnic minorities (52.78%), and urban residents (79.29%). The mean CES-D score for middle school students in Yunnan Province was (15.31±10.83). Female students had a significantly higher mean score (16.63±11.41) than male students (13.95±10.02) (P<0.001). Senior high school students had a significantly higher mean score (16.61±10.61) compared to both junior high school students (14.74±11.45) and vocational high school students (13.10±7.71) (all pairwise comparisons P<0.001). The prevalence of depressive symptoms among middle school students in Yunnan Province was 28.18%. The prevalence was significantly higher in females (34.09%) than in males (22.07%). By school type, the detection rate was highest among senior high school students (33.39%), followed by junior high school students (26.29%) and vocational high school students (17.27%) (P<0.05). Multivariate logistic regression analysis showed that female gender (OR=2.16, 95%CI: 1.86‒2.50), being in junior high school (OR=2.43, 95%CI: 1.84‒3.20) or senior high school (OR=2.27, 95%CI: 1.73‒2.98), not living with parents (OR=1.24, 95%CI: 1.07‒1.44), irregular breakfast consumption (OR=1.52, 95%CI: 1.33‒1.75), lack of moderate-to-vigorous physical activity (MVPA) (OR=1.69, 95%CI: 1.37‒2.09), sleep duration ≤5 h per night (OR=2.52, 95%CI: 2.02‒3.14) or 6‒7 h per night (OR=1.47, 95%CI: 1.25‒1.73), smoking (OR=1.86, 95%CI: 1.56‒2.23), and alcohol consumption (OR=1.81, 95%CI: 1.54‒2.13) were positively associated with depressive symptoms. In contrast, screen time ≤1 h (OR=0.71, 95%CI: 0.59‒0.86) was negatively associated with depressive symptoms. Stratified analyses showed that female students not living with parents (OR=1.29, 95%CI: 1.06‒1.58), senior high school students (OR=1.51, 95%CI: 1.21‒1.88), and Han Chinese students (OR=1.37, 95%CI: 1.11‒1.69) were more likely to experience depressive symptoms. Han Chinese students who smoked were also more likely to have depressive symptoms (OR=1.72, 95%CI: 1.34‒2.21). In contrast, male students with screen time ≤1 h (OR=0.71, 95%CI: 0.53‒0.95) and ethnic minority students (OR=0.74, 95%CI: 0.58‒0.95) were less likely to experience depressive symptoms. Regardless of gender, irregular breakfast consumption, lack of MVPA, sleep duration less than 8 h per night, smoking, and alcohol consumption were all positively associated with depressive symptoms (P<0.05). Among both junior and senior high school students, irregular breakfast consumption, lack of MVPA, smoking, and alcohol consumption were positively associated with depressive symptoms (all P<0.05), while screen time ≤1 h was negatively associated with depressive symptoms (all P<0.05). For junior high school students, engaging in 1‒2 days of MVPA per week, screen time more than 2 h per day, and sleep duration 6‒7 h per night were all positively associated with depressive symptoms (all P<0.05). Among junior high, senior high, and vocational high school students, sleep duration ≤5 h per night was positively associated with depressive symptoms (P<0.05). For both Han Chinese and ethnic minority students, irregular breakfast consumption, lack of MVPA, sleep duration less than 8 h per night, and alcohol consumption were all positively associated with depressive symptoms (all P<0.05). ConclusionThe prevalence of depressive symptoms among middle school students in Yunnan Province is comparable to that in central China and higher than that in northern regions. Prevention and control efforts should prioritize female students and those in junior and senior high school stages. Universal improvements in lifestyle behaviors among middle school students, such as regular breakfast consumption, MVPA, sufficient sleep (≥8 h), and abstinence from smoking and alcohol. Particular attention should be given to limiting excessive screen time among junior high school students and addressing the mental health needs of females not living with their parents, senior high school students, and Han Chinese students.
3.Schwann cells promote peripheral nerve regeneration:retrospect and prospect
Zhenyi FU ; Junhao LI ; Yating ZHANG ; Yunkai HE ; Junyu LIU ; Yunhao WEI ; Jiaxin LIU
Chinese Journal of Tissue Engineering Research 2026;30(5):1236-1246
BACKGROUND:Peripheral nerve axon rupture seriously affects patients' physical function and mental health.Microsurgery,nerve autograft,nerve allograft,fibrin glue and catheter technology are the main treatments for peripheral nerve injury,each of which has its own advantages and disadvantages,but the overall treatment effect is not satisfactory.Despite the clinical success of Schwann cells in promoting axonal regeneration,there are still many challenges in the treatment with Schwann cells,such as slow expansion of Schwann cells,immune rejection,and low survival rate of transplanted cells.OBJECTIVE:To summarize the role and mechanism of Schwann cells in promoting the regeneration of peripheral nerve axons,and the difficulties and challenges of Schwann cells in the process of nerve regeneration treatment.METHODS:PubMed,Medline,WanFang,VIP,and CNKI were searched by computer using the search terms of"Schwann cells,synaptic Schwann cell,macrophage,peripheral nerve axon rupture,Wallerian degeneration,Peripheral nerve axon regeneration,Central nervous system repair"in English and Chinese.Literature related to Schwann cell proliferation and differentiation,promotion of peripheral nerve regeneration,and clinical applications was retrieved from database inception to October 2024,and a total of 95 articles were finally included for review.RESULTS AND CONCLUSION:Schwann cells interact with macrophages,T cells and other cells,to initiate the regeneration process through signaling pathways,including Krox20/C-Jun,NRG-1/ErbB,Notch,MAPK,and PI3K/Akt/mTOR,synthesize and release nerve growth factors,and thus promote regeneration of the peripheral nervous system.Schwann cells have been experimentally demonstrated to have great potential in peripheral nerve repair and are expected to become the key target of therapeutic intervention.However,there are still problems such as difficulties in cell harvest and culture,as well as the occurrence of other diseases during the treatment process.
4.Schwann cells promote peripheral nerve regeneration:retrospect and prospect
Zhenyi FU ; Junhao LI ; Yating ZHANG ; Yunkai HE ; Junyu LIU ; Yunhao WEI ; Jiaxin LIU
Chinese Journal of Tissue Engineering Research 2026;30(5):1236-1246
BACKGROUND:Peripheral nerve axon rupture seriously affects patients' physical function and mental health.Microsurgery,nerve autograft,nerve allograft,fibrin glue and catheter technology are the main treatments for peripheral nerve injury,each of which has its own advantages and disadvantages,but the overall treatment effect is not satisfactory.Despite the clinical success of Schwann cells in promoting axonal regeneration,there are still many challenges in the treatment with Schwann cells,such as slow expansion of Schwann cells,immune rejection,and low survival rate of transplanted cells.OBJECTIVE:To summarize the role and mechanism of Schwann cells in promoting the regeneration of peripheral nerve axons,and the difficulties and challenges of Schwann cells in the process of nerve regeneration treatment.METHODS:PubMed,Medline,WanFang,VIP,and CNKI were searched by computer using the search terms of"Schwann cells,synaptic Schwann cell,macrophage,peripheral nerve axon rupture,Wallerian degeneration,Peripheral nerve axon regeneration,Central nervous system repair"in English and Chinese.Literature related to Schwann cell proliferation and differentiation,promotion of peripheral nerve regeneration,and clinical applications was retrieved from database inception to October 2024,and a total of 95 articles were finally included for review.RESULTS AND CONCLUSION:Schwann cells interact with macrophages,T cells and other cells,to initiate the regeneration process through signaling pathways,including Krox20/C-Jun,NRG-1/ErbB,Notch,MAPK,and PI3K/Akt/mTOR,synthesize and release nerve growth factors,and thus promote regeneration of the peripheral nervous system.Schwann cells have been experimentally demonstrated to have great potential in peripheral nerve repair and are expected to become the key target of therapeutic intervention.However,there are still problems such as difficulties in cell harvest and culture,as well as the occurrence of other diseases during the treatment process.
5.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
6.Application of liquid biopsy in early screening and diagnosis of pancreatic cancer
Junyu CHEN ; Pan ZHAO ; Xiao LI ; Zhengcai LIU ; Shuqiang YUE
Journal of Clinical Hepatology 2026;42(6):1481-1488
Pancreatic cancer is characterized by occult clinical manifestations and high malignancy, and conventional imaging examinations and carbohydrate antigen 19-9 lack sufficient sensitivity and specificity for detecting early-stage pancreatic cancer lesions. Difficulty in early diagnosis severely restricts the long-term survival of pancreatic cancer patients. Liquid biopsy targets the biomarkers in body fluid samples, including circulating tumor cells, circulating tumor DNA, circulating tumor microRNA, and extracellular vesicles, showing the advantages of noninvasiveness and continuous monitoring. This review systematically summarizes the latest advances in liquid biopsy for the early screening and diagnosis, recurrence prediction, and prognostic assessment of pancreatic cancer, aiming to provide new insights and references for precision screening of high-risk populations and the clinical translation of liquid biopsy.
7.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
8.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
9.Dystrophinopathy in the paravertebral muscle of adolescent idiopathic scoliosis: a prospective case-control study in China
Junyu LI ; Danfeng ZHENG ; Zekun LI ; Jiaxi LI ; Zexi YANG ; Xiang ZHANG ; Yingshuang ZHANG ; Miao YU
Asian Spine Journal 2025;19(1):64-73
Methods:
This study enrolled 40 patients with AIS, 20 patients with congenital scoliosis (CS), and 20 patients with spinal degenerative disease (SDD). All patients underwent open posterior surgery in our hospital, and a paravertebral muscle (multifidus muscle) biopsy was performed intraoperatively. This study included many indexes that describe muscle, especially dystrophin staining. The above pathological results were compared among the AIS, CS, and SDD groups. The correlation between the Cobb angle and Nash–Moe classification and the above pathological results was analyzed in patients with AIS.
Results:
Significant reductions in the dystrophin staining of dystrophin-1 (p<0.001), dystrophin-2 (p<0.001), and dystrophin-3 (p<0.001) were observed in the AIS group than in the CS and SDD groups. The higher the Nash–Moe classification in the AIS group, the more significant the loss of dystrophin-2 (p=0.042) in the convex paraspinal muscles. Additionally, a significantly positive correlation was observed between the reductions of dystrophin-2 on the concave side of the AIS group and Cobb angle (p=0.011).
Conclusions
Dystrophin protein deficiency in the paraspinal muscles plays a crucial role in AIS formation and progression. The severity of scoliosis in patients with AIS is correlated with the extent of dystrophin loss in the paravertebral muscles. Therefore, dystrophin dysfunction may be relevant to AIS occurrence and development.
10.Dystrophinopathy in the paravertebral muscle of adolescent idiopathic scoliosis: a prospective case-control study in China
Junyu LI ; Danfeng ZHENG ; Zekun LI ; Jiaxi LI ; Zexi YANG ; Xiang ZHANG ; Yingshuang ZHANG ; Miao YU
Asian Spine Journal 2025;19(1):64-73
Methods:
This study enrolled 40 patients with AIS, 20 patients with congenital scoliosis (CS), and 20 patients with spinal degenerative disease (SDD). All patients underwent open posterior surgery in our hospital, and a paravertebral muscle (multifidus muscle) biopsy was performed intraoperatively. This study included many indexes that describe muscle, especially dystrophin staining. The above pathological results were compared among the AIS, CS, and SDD groups. The correlation between the Cobb angle and Nash–Moe classification and the above pathological results was analyzed in patients with AIS.
Results:
Significant reductions in the dystrophin staining of dystrophin-1 (p<0.001), dystrophin-2 (p<0.001), and dystrophin-3 (p<0.001) were observed in the AIS group than in the CS and SDD groups. The higher the Nash–Moe classification in the AIS group, the more significant the loss of dystrophin-2 (p=0.042) in the convex paraspinal muscles. Additionally, a significantly positive correlation was observed between the reductions of dystrophin-2 on the concave side of the AIS group and Cobb angle (p=0.011).
Conclusions
Dystrophin protein deficiency in the paraspinal muscles plays a crucial role in AIS formation and progression. The severity of scoliosis in patients with AIS is correlated with the extent of dystrophin loss in the paravertebral muscles. Therefore, dystrophin dysfunction may be relevant to AIS occurrence and development.

Result Analysis
Print
Save
E-mail