1.Overcoming organ shortage: key clinical application technology breakthroughs and future prospects in xenogeneic organ transplantation
Junze CHEN ; Cheng ZHANG ; Yongyuan JIAN ; Kun DONG ; Shuaijun MA ; Chunqiang DONG
Organ Transplantation 2026;17(3):393-404
The technology of xenogeneic organ transplantation, as one of the core strategies to address the current contradiction between the supply and demand of transplant organs, has achieved significant breakthroughs from basic research to clinical application driven by factors such as the innovation of gene modification technology, the injection of research capital and the expansion of clinical trials, especially with the first actual clinical application of a pig heart-to-human transplant. China is also at the forefront of this field. This article intends to summarize the international research trends of xenogeneic organ transplantation (including financial support, the evolution of research stages and global clinical trial cases), and analyze the evolution and optimization of xenogeneic transplantation immunosuppression schemes, as well as the breakthroughs and unresolved scientific issues in current key clinical application technologies. The aim is to comprehensively present the progress of this field from basic research to clinical transformation, and provide references for promoting the rapid development of China's xenogeneic transplantation technology and subsequent clinical transformation and research directions.
2.Clinical translation of mid-infrared quantum cascade laser-based label-free molecular diagnostics and imaging
Medical Lasers 2026;15(1):43-52
Mid-infrared spectroscopy captures fundamental molecular vibrations, enabling label-free chemical contrast from tissues, cells, and biofluids without the need for dyes or antibodies. Quantum cascade lasers deliver high spectral brightness and narrowband emission in the mid-infrared region, facilitating faster, more compact infrared measurement systems than conventional thermal-source Fourier transform infrared platforms. This review examines the clinical translation of quantum cascade laser-based mid-infrared diagnostics and imaging, emphasizing applications across different sample types, hardware architectures that govern measurement fidelity and speed, and workflow considerations essential for clinical deployment. Principal barriers encompass atmospheric interference from water vapor and carbon dioxide, scattering-related spectral distortions, substrate artifacts, and pre-analytical variability. We outline a comprehensive translation framework that integrates analytical validity, clinical validity, and operational feasibility, addressing practical constraints of turnaround time, staffing, and cost-effectiveness for real-world implementation.
3.Erratum: Guidelines for the Use of Botulinum Toxin in Otolaryngology From the Korean Society of Laryngology, Phoniatrics and Logopedics Guideline Task Force
; Myung Jin BAN ; Chang Hwan RYU ; Joo Hyun WOO ; Young Chan LEE ; Dong Kun LEE ; Minsu KWON ; Yong Tae HONG ; Gil Joon LEE ; Hyung Kwon BYEON ; Seung Ho CHOI ; Seung Won LEE
Clinical and Experimental Otorhinolaryngology 2026;19(2):209-209
4.Assessment of Fat Fraction and Muscle Atrophy in the Supraspinatus Muscle:Optimal Sagittal Plane Selection in the Shoulder MRI
Chanyoung RHEE ; Hye Jin YOO ; Tae Kun KIM ; Hee Dong CHAE ; Ja-Young CHOI ; Sung Hwan HONG
Investigative Magnetic Resonance Imaging 2026;30(1):29-37
Purpose:
To assess the accuracy of supraspinatus muscle fat fraction and atrophy measured on the Y-view compared with the newly proposed fossa-view sagittal MRI plane.
Materials and Methods:
This study included 84 patients (36 male; mean age, 65.1 ± 10.1 years) who underwent shoulder MRI with extended oblique sagittal T1-weighted and three-dimensional (3D) six-echo Dixon imaging between December 2020 and November 2022. The reference fat fraction was calculated by integrating voxel-wise Dixon values, while supraspinatus muscle volume was quantified using a 3D nnU-Net algorithm and normalized to the scapular volume to derive the standardized muscle index (SMI). Fat fraction and cross-sectional area were quantified on the Y-view and fossaview and compared with the reference values. Subgroup analyses were performed using fatty degeneration and retraction grades.
Results:
Agreement with the reference fat fraction was significantly higher for the fossa-view (intraclass correlation coefficient [ICC], 0.923) than for the Y-view (ICC, 0.822;p = 0.006). The fossa-view showed smaller deviations and narrower limits of agreement.For SMI, the Y-view (ICC, 0.782) showed higher agreement than the fossa-view (ICC, 0.694), although the difference was not statistically significant (p = 0.219). Subgroup analyses showed better Y-view performance at lower retraction grades and better fossa-view performance at higher grades, although the differences were not statistically significant (all p > 0.05).
Conclusion
Both planes reliably quantified the fat fraction with greater accuracy in the fossa-view. However, single-plane assessment of muscle atrophy was less reliable, underscoring the need for MRI evaluation of the entire muscle.
6.Validation of the Korean Version of the 24-Item Early-Onset Scoliosis Questionnaire: A Multicenter Study from the Korean Research Society of Spinal Deformity
Chang Ju HWANG ; Sam Yeol CHANG ; Kun-Bo PARK ; Dong-Ho LEE ; Jae Hwan CHO ; Hiroko MATSUMOTO ; Sehan PARK
Clinics in Orthopedic Surgery 2025;17(1):123-129
Background:
A 24-item early-onset scoliosis questionnaire (EOSQ-24) has been developed as a valid tool for assessing the physical and emotional function of patients with early-onset scoliosis (EOS). Previous studies that conducted transcultural adaptation of the original EOSQ-24 into other languages have demonstrated the high reliability of the questionnaire. However, a Korean version of the EOSQ-24 is not available, limiting optimal patient assessment in this nation. Therefore, this study was conducted to develop and validate a Korean version of EOSQ-24.
Methods:
The original English version of the EOSQ-24 was cross-culturally adapted following standard guidelines. The final version of the Korean EOSQ-24 was prospectively applied to a group of patients who were native Korean speakers. Internal consistency was evaluated using the Cronbach α coefficient and item-total correlations. The mean, standard deviation, floor effect, and ceiling effect of each item were also assessed.
Results:
A total of 102 caregivers of patients with EOS (45 males and 57 females) completed the Korean EOSQ-24. The patients’ average age was 6.39 ± 2.16 years. The Cronbach α coefficient for the 24-item scale was 0.942, indicating excellent reliability. The corrected item-total correlation coefficients ranged between 0.449 and 0.788. The mean value of the EOSQ-24 questionnaire was 3.19. Floor and ceiling effects for all questionnaires were below 30%, which could be considered acceptable.
Conclusions
Our study successfully developed and validated the Korean version of the EOSQ-24, providing a reliable instrument for assessing the physical and emotional well-being of patients with EOS and their caregivers in the Korean context. The widespread adoption of the Korean EOSQ-24 in clinical practice and research settings can enhance the quality of care and improve outcomes for individuals affected by EOS in Korea.
8.Validation of the Korean Version of the 24-Item Early-Onset Scoliosis Questionnaire: A Multicenter Study from the Korean Research Society of Spinal Deformity
Chang Ju HWANG ; Sam Yeol CHANG ; Kun-Bo PARK ; Dong-Ho LEE ; Jae Hwan CHO ; Hiroko MATSUMOTO ; Sehan PARK
Clinics in Orthopedic Surgery 2025;17(1):123-129
Background:
A 24-item early-onset scoliosis questionnaire (EOSQ-24) has been developed as a valid tool for assessing the physical and emotional function of patients with early-onset scoliosis (EOS). Previous studies that conducted transcultural adaptation of the original EOSQ-24 into other languages have demonstrated the high reliability of the questionnaire. However, a Korean version of the EOSQ-24 is not available, limiting optimal patient assessment in this nation. Therefore, this study was conducted to develop and validate a Korean version of EOSQ-24.
Methods:
The original English version of the EOSQ-24 was cross-culturally adapted following standard guidelines. The final version of the Korean EOSQ-24 was prospectively applied to a group of patients who were native Korean speakers. Internal consistency was evaluated using the Cronbach α coefficient and item-total correlations. The mean, standard deviation, floor effect, and ceiling effect of each item were also assessed.
Results:
A total of 102 caregivers of patients with EOS (45 males and 57 females) completed the Korean EOSQ-24. The patients’ average age was 6.39 ± 2.16 years. The Cronbach α coefficient for the 24-item scale was 0.942, indicating excellent reliability. The corrected item-total correlation coefficients ranged between 0.449 and 0.788. The mean value of the EOSQ-24 questionnaire was 3.19. Floor and ceiling effects for all questionnaires were below 30%, which could be considered acceptable.
Conclusions
Our study successfully developed and validated the Korean version of the EOSQ-24, providing a reliable instrument for assessing the physical and emotional well-being of patients with EOS and their caregivers in the Korean context. The widespread adoption of the Korean EOSQ-24 in clinical practice and research settings can enhance the quality of care and improve outcomes for individuals affected by EOS in Korea.
9.Validation of the Korean Version of the 24-Item Early-Onset Scoliosis Questionnaire: A Multicenter Study from the Korean Research Society of Spinal Deformity
Chang Ju HWANG ; Sam Yeol CHANG ; Kun-Bo PARK ; Dong-Ho LEE ; Jae Hwan CHO ; Hiroko MATSUMOTO ; Sehan PARK
Clinics in Orthopedic Surgery 2025;17(1):123-129
Background:
A 24-item early-onset scoliosis questionnaire (EOSQ-24) has been developed as a valid tool for assessing the physical and emotional function of patients with early-onset scoliosis (EOS). Previous studies that conducted transcultural adaptation of the original EOSQ-24 into other languages have demonstrated the high reliability of the questionnaire. However, a Korean version of the EOSQ-24 is not available, limiting optimal patient assessment in this nation. Therefore, this study was conducted to develop and validate a Korean version of EOSQ-24.
Methods:
The original English version of the EOSQ-24 was cross-culturally adapted following standard guidelines. The final version of the Korean EOSQ-24 was prospectively applied to a group of patients who were native Korean speakers. Internal consistency was evaluated using the Cronbach α coefficient and item-total correlations. The mean, standard deviation, floor effect, and ceiling effect of each item were also assessed.
Results:
A total of 102 caregivers of patients with EOS (45 males and 57 females) completed the Korean EOSQ-24. The patients’ average age was 6.39 ± 2.16 years. The Cronbach α coefficient for the 24-item scale was 0.942, indicating excellent reliability. The corrected item-total correlation coefficients ranged between 0.449 and 0.788. The mean value of the EOSQ-24 questionnaire was 3.19. Floor and ceiling effects for all questionnaires were below 30%, which could be considered acceptable.
Conclusions
Our study successfully developed and validated the Korean version of the EOSQ-24, providing a reliable instrument for assessing the physical and emotional well-being of patients with EOS and their caregivers in the Korean context. The widespread adoption of the Korean EOSQ-24 in clinical practice and research settings can enhance the quality of care and improve outcomes for individuals affected by EOS in Korea.

Result Analysis
Print
Save
E-mail