1.Consistency analysis of UBM and ArcScan Insight 100 measurements in the anterior segment of the myopic eye
Ruirui SUN ; Jin LI ; Keying CAO ; Weichen ZHANG ; Meng XIE ; Chenjiu PANG
Chinese Journal of Experimental Ophthalmology 2025;43(9):818-825
Objective:To evaluate the repeatability of anterior segment biometry measurements obtained using ultrasound biomicroscopy (UBM) and the ArcScan Insight 100, and to compare the agreement between the two devices.Methods:A cross-sectional study was conducted.Seventy myopic patients (70 eyes) who underwent V4c implantable collamer lens implantation at Henan Eye Hospital from March to May 2023 were included.The ArcScan Insight 100 and UBM were used to measure the following parameters three times: angle-to-angle distance (ATA), sulcus-to-sulcus distance (STS), anterior chamber depth (ACD), crystalline lens rise (CLR), anterior chamber width (ACW), ciliary body inner diameter (CBID), anterior chamber angle (ACA), trabecular-ciliary angle (TCA) and maximum ciliary body thickness (CBTmax). The repeatability of anterior segment biological measurements obtained using the two devices was assessed by intraclass correlation coefficient (ICC). The consistency between the two instruments was evaluated by Bland-Altman consistency test.This study complied with the Declaration of Helsinki and was approved by the Ethics Committee of Henan Eye Hospital (No.HNEECKY-2021[13]). All patients understood the purpose and significance of this study and signed the informed consent form.Results:The repeatability of ATA, STS, ACD, CLR, ACW, CBID, ACA, TCA and CBTmax measured by UBM and ArcScan Insight 100 was good (all ICC>0.9). There was no significant difference in ACD, ACW, and ACA between the two instruments ( t=0.696, -1.025, -1.447; all P>0.05). ATA, STS, CLR and CBID measured by UBM were lower and TCA and CBTmax were higher than those measured by UBM ArcScan Insight 100, and the differences were statistically significant ( t=-8.586, -12.551, -4.481, -4.420, 4.535, 7.812; all P<0.05). The differences of ATA, STS, ACD, CLR, ACW, CBID and CBTmax between UBM and ArcScan Insight 100 were 0.38, 0.47, -0.01, 0.07, 0.3, 0.26 and -0.21 mm, respectively, with the 95% limits of agreement (LoA) of (-0.34, 1.10), (-0.15, 1.09), (-0.28, 0.26), (-0.20, 0.35), (-0.33, 0.93), (-0.71, 1.23) and (-0.64, 0.23)mm, respectively, which showed good coherence.The differences in ACA and TCA measurements were 2.26° and -7.81°, respectively, and the 95%LoA values were (-23.36°, 27.89°) and (-36.05°, 20.43°), respectively, with poor coherence.There was a strong positive correlation in ACD measurements measured by UBM and ArcScan Insight 100 ( r=0.827, P<0.05). There were moderate positive correlations in ATA, STS, CLR, ACW and CBID ( r=0.678, 0.749, 0.617, 0.765, 0.519; all P<0.05). There was no significant correlation in ACA, TCA and CBTmax ( r=0.270, 0.032, 0.178; all P>0.05). Conclusions:The repeatability of ArcScan Insight 100 and UBM in measuring anterior segment biological parameters is good.However, the consistency of ACA, TCA and CBTmax measured by the two instruments is poor and may be affected by self-regulation of the body.ATA, STS, ACD, CLR, ACW and CBID have good consistency and can be used interchangeably.
2.Consistency analysis of UBM and ArcScan Insight 100 measurements in the anterior segment of the myopic eye
Ruirui SUN ; Jin LI ; Keying CAO ; Weichen ZHANG ; Meng XIE ; Chenjiu PANG
Chinese Journal of Experimental Ophthalmology 2025;43(9):818-825
Objective:To evaluate the repeatability of anterior segment biometry measurements obtained using ultrasound biomicroscopy (UBM) and the ArcScan Insight 100, and to compare the agreement between the two devices.Methods:A cross-sectional study was conducted.Seventy myopic patients (70 eyes) who underwent V4c implantable collamer lens implantation at Henan Eye Hospital from March to May 2023 were included.The ArcScan Insight 100 and UBM were used to measure the following parameters three times: angle-to-angle distance (ATA), sulcus-to-sulcus distance (STS), anterior chamber depth (ACD), crystalline lens rise (CLR), anterior chamber width (ACW), ciliary body inner diameter (CBID), anterior chamber angle (ACA), trabecular-ciliary angle (TCA) and maximum ciliary body thickness (CBTmax). The repeatability of anterior segment biological measurements obtained using the two devices was assessed by intraclass correlation coefficient (ICC). The consistency between the two instruments was evaluated by Bland-Altman consistency test.This study complied with the Declaration of Helsinki and was approved by the Ethics Committee of Henan Eye Hospital (No.HNEECKY-2021[13]). All patients understood the purpose and significance of this study and signed the informed consent form.Results:The repeatability of ATA, STS, ACD, CLR, ACW, CBID, ACA, TCA and CBTmax measured by UBM and ArcScan Insight 100 was good (all ICC>0.9). There was no significant difference in ACD, ACW, and ACA between the two instruments ( t=0.696, -1.025, -1.447; all P>0.05). ATA, STS, CLR and CBID measured by UBM were lower and TCA and CBTmax were higher than those measured by UBM ArcScan Insight 100, and the differences were statistically significant ( t=-8.586, -12.551, -4.481, -4.420, 4.535, 7.812; all P<0.05). The differences of ATA, STS, ACD, CLR, ACW, CBID and CBTmax between UBM and ArcScan Insight 100 were 0.38, 0.47, -0.01, 0.07, 0.3, 0.26 and -0.21 mm, respectively, with the 95% limits of agreement (LoA) of (-0.34, 1.10), (-0.15, 1.09), (-0.28, 0.26), (-0.20, 0.35), (-0.33, 0.93), (-0.71, 1.23) and (-0.64, 0.23)mm, respectively, which showed good coherence.The differences in ACA and TCA measurements were 2.26° and -7.81°, respectively, and the 95%LoA values were (-23.36°, 27.89°) and (-36.05°, 20.43°), respectively, with poor coherence.There was a strong positive correlation in ACD measurements measured by UBM and ArcScan Insight 100 ( r=0.827, P<0.05). There were moderate positive correlations in ATA, STS, CLR, ACW and CBID ( r=0.678, 0.749, 0.617, 0.765, 0.519; all P<0.05). There was no significant correlation in ACA, TCA and CBTmax ( r=0.270, 0.032, 0.178; all P>0.05). Conclusions:The repeatability of ArcScan Insight 100 and UBM in measuring anterior segment biological parameters is good.However, the consistency of ACA, TCA and CBTmax measured by the two instruments is poor and may be affected by self-regulation of the body.ATA, STS, ACD, CLR, ACW and CBID have good consistency and can be used interchangeably.
3.Analytical performance of a candidate reference measurement procedure for serum 17α-hydroxyprogesterone based on liquid chromatography tandem mass spectrometry
Keying YU ; Hewei SUN ; Zhonggan JIN ; Sujie ZHANG ; Qing LI ; Yi JU
Chinese Journal of Laboratory Medicine 2022;45(5):449-455
Objective:To determine the analytical performance of a candidate reference measurement procedure for 17α-hydroxyprogesterone in human serum by liquid chromatography-tandem mass spectrometry (LC-MS/MS).Methods:The serum spiked with a deuterium-labeled internal standard was extracted from serum from individual undergoing physical examination by liquid-liquid extraction with n-hexane/ethyl acetate (3∶2, v/v), separated by C18 reversed-phase chromatography and detected by positive electrospray ionization mass spectrometry. According to the Clinical and Laboratory Standards Institute (CLSI) C62-A documents, the analytical performance including linearity, limit of detection,limit of quantitation,relative matrix effect,precision and trueness,carry-over and specificity was evaluated.Results:The linear range of 17α-hydroxyprogesterone by LC-MS/MS was 0.21-119.67 μg/L. The limit of detection and limit of quantitation were 5.218 ng/L and 0.116 μg/L. The relative matrix effects were -0.02%, -0.40% and -0.90% for sera and solution mixtures in 3 different ratios (50∶50, 80:20 and 20∶80). The coefficients of variation ( CVs) of intra-assay were 1.73%-2.11%, 0.98%-1.71%, 0.47%-0.87% at 0.164 μg/L, 14.81 μg/L, 81.63 μg/L and the CVs of inter-assay were 1.82%, 1.03%, 0.80% at above three concentrations. The average recovery rates of 3 levels (0.5, 20 and 100 μg/L) were 100.4%, 101.7%, 102.8%, respectively. The measured values of GBW09829 of National Institute of Metrology were within the specified uncertainty range. Conclusion:The candidate reference measurement procedure for 17α-hydroxyprogesterone in human by LC-MS/MS is established with good accuracy and precision, which can be clinically used for measurement traceability.
4.Sterilization of Small Packs of Surgical Instruments:A Cost Performance Study
Jun ZHAO ; Keying JIN ; Jiangling YI ; Bing ZHANG
Chinese Journal of Nosocomiology 2009;0(22):-
OBJECTIVE To analyze the cost performance of small packs of surgical instruments and to look for their optimizing sterilization schemes.METHODS 720 sample from total surgical instruments were sefested,pressuresteam sterilization ethylene Oxide and hydrogen peroxide plasma sferilization were pexformal and compared.Statistics and analyzing finally under the condition of each kind puts The sterilization effect,cost and the period were analyzed.RESULTS All three methods call guarantee the sterilization effect,but the cost of EO and plasma were more than those of pressuresteam method(452% and 960%).CONCLUSIONS Pressuresteam sterilization show advantages in small packing instruments.

Result Analysis
Print
Save
E-mail