1.Time series study on influence of sulfur dioxide exposure on hospitalization of chronic obstructive pulmonary disease in Lanzhou from 2016 to 2020
Sheng LIN ; Boxi FENG ; Yongyue LI ; Yiwei HUANG ; Kai ZHENG ; Mingxuan LIU ; Yingying YANG ; Xingmin WEI ; Jianjun WU
Journal of Environmental and Occupational Medicine 2026;43(4):451-457
Background In 2021, chronic obstructive pulmonary disease (COPD) emerged as the forth leading cause of death in the world. However, the impact of air pollutants on COPD is still inconsistent across current studies. Objective To analyze the relationship between ambient sulfur dioxide (SO2) exposure and hospital admissions for COPD in Lanzhou, and to examine the modified effects of SO2 across different genders, age groups, and seasons. Methods A total of
2.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
3.Pre-operative risk assessment of hepatocellular carcinoma recurrence in liver transplant recipients by non-invasive detection of pre-existing genetic lesions
Suqin YANG ; Sunbin LING ; Jianhua LI ; Yan WANG ; Jiapei WANG ; Qiwei HUANG ; Fanming LIU ; Yiqi ZHUANG ; Yingyu ZHENG ; Rui WANG ; Zhe YANG ; Xiaoping ZHENG ; Kai WANG ; Zhikun LIU ; Jun CHEN ; Jianguo WANG ; Haiyang XIE ; Lin ZHOU ; Leiming CHEN ; Guoqiang CAO ; Dandan CHEN ; Junfang JI ; Bin ZHAO ; Chao JIANG ; Di LU ; Xuyong WEI ; Hangjin JIANG ; Qiaonan SHAN ; Hengbo SHI ; Yong-Zhen XU ; Shusen ZHENG ; Zhengxin WANG ; Shengda LIN ; Xiao XU
Clinical and Molecular Hepatology 2026;32(2):884-903
Background/Aims:
Liver transplantation (LT) following total hepatectomy is a life-saving treatment for hepatocellular carcinoma (HCC). The HCC recurrence after LT hinders the effectiveness of the procedure. The objective of this study is to develop a pre-operative risk stratification model based on a liquid biopsy.
Methods:
We conducted a comprehensive multi-omics study of 260 HCC patients from three centers, including clinical data, low-coverage whole-genome sequencing of cell-free DNA (cfDNA) from plasma, as well as whole-exome, single-nucleus RNA, and spatial transcriptomics from matched tumor and non-tumor tissues.
Results:
We identified cfDNA-derived copy number alteration (CNA) signatures associated with post-transplant recurrence. By integrating cfDNA-derived CNA profiles with single-cell transcriptomic data, we traced recurrence-associated cfDNA to a distinct subpopulation of malignant cells within the primary tumor. These cells were embedded in a pro-metastatic microenvironment of specialized endothelial subtypes and cancer-associated fibroblasts. Notably, most recurrence-associated lesions were detectable in cfDNA prior to liver transplantation (LT). Building on these insights, we developed the ZJU Criteria based on CNA fragments and tumor markers, a pre-LT risk prediction tool that integrates conventional clinical factors with cfDNA-derived CNA signatures, and validated it using internal and independent external cohorts.
Conclusion
Our findings suggest that post-transplant recurrence commonly originates from advanced subclones that emerge late during tumor evolution. The ZJU Criteria provides an accurate, non-invasive strategy that significantly improves pre-LT risk stratification and clinical decision-making for patients with HCC.
4.Determination of prototype components and metabolites of Si-Ni-San in healthy and ulcerative colitis mice by an integrated targeted and pseudo-targeted UPLC-QqQ-MS method
Yanfang CAO ; Yuan ZHENG ; Yongshun CHEN ; Sihan LI ; Kai FENG ; Xingjia LI ; Rui SONG
Journal of China Pharmaceutical University 2026;57(3):351-359
This study aimed to establish an analytical method capable of simultaneously quantifying the prototype components of Si-Ni-San and screening their metabolites to elucidate its tissue distribution and metabolic characteristics in an ulcerative colitis (UC) mouse model. To this end, an integrated analysis strategy based on UPLC-QqQ-MS was developed and validated, combining the targeted quantification of 12 prototype components with a pseudo-targeted metabolite screening technique based on ion pair list-triggered data-dependent acquisition. Samples were extracted with 80% methanol (100 mg/mL) and processed with internal standards. Separation was achieved on a Waters Acquity UPLC HSS PFP column using a gradient elution with a mobile phase consisting of acetonitrile and 5 mmol/L ammonium acetate containing 0.1% formic acid. Analysis was performed using an electrospray ionization (ESI) source in multiple reaction monitoring mode. Methodological validation confirmed that all parameters met the requirements for bio-sample analysis. Application of this method revealed that the content of Si-Ni-San prototype components in the colon, liver, and kidneys of UC mice was significantly higher than that in healthy mice. Furthermore, the number of phase II metabolites was markedly greater than that of phase I metabolites in all tested samples. The results demonstrate the reliability of the established method and preliminarily reveal the tissue distribution characteristics of Si-Ni-San under UC conditions and its metabolism pattern dominated by phase II conjugation, which provides a methodological basis and experimental data for further in-depth research into its effective target tissues and pharmacodynamic material basis.
5.Study on Vibration Characteristics of Deep Brain Stimulator Induced by Magnetic Resonance Gradient Magnetic Field.
Ya CHEN ; Peng CAO ; Sheng HU ; Kai ZHENG ; Xun LIU
Chinese Journal of Medical Instrumentation 2025;49(1):8-14
The gradient coils of MRI equipment can induce vibrations in implantable medical devices, causing periodic vibrations of implantable medical devices with respect to the surrounding tissue. This not only results in instrument failure but also causes discomfort to the patient. Therefore, studying the vibration characteristics of implantable devices under different scanning sequences and the orientation of the device relative to the magnetic field is crucial for comprehending vibration performance. This study observed the vibration spectra of a full cranial bone-implanted neurostimulator by using laser vibrometry under typical rapid imaging sequences and explored the impact of different magnetic field orientations on vibration. The results demonstrated that the rapid echo sequences induced diverse and rich vibration components, whereas the planar echo sequences caused relatively simple vibrations. Additionally, the strongest vibrations normally occurred in the maximum conductive surface parallel to the phase-coded direction. It revealed the factors influencing the vibrations of skull fixation active implantable devices and provided guidance for enhancing device safety and protecting patient well-being during MR examinations.
Vibration
;
Magnetic Resonance Imaging
;
Deep Brain Stimulation/instrumentation*
;
Magnetic Fields
;
Humans
6.Exploration and Practice of Performance Evaluation System for Large Medical Equipment Based on Internet of Things Technology.
Chang SU ; Caixian ZHENG ; Linling ZHANG ; Yunming SHEN ; Kai FAN ; Tingting DONG ; Hangyan ZHAO ; Xiaofeng WANG ; Dawei QIAO ; Kun ZHENG
Chinese Journal of Medical Instrumentation 2025;49(2):191-196
Medical equipment, as an important indicator of smart hospital evaluation, plays a vital role in hospital operations. To ensure the safe and efficient operation of medical equipment, a reasonable performance evaluation system is indispensable. This study introduces a platform based on Internet of Things (IoT) technology that connects medical devices and collects data, achieving standardized and structured data processing, and supporting online operational supervision. Through the Delphi method, a performance evaluation system for large medical equipment is constructed, including 4 primary indicators and 22 secondary indicators. DICOM data acquisition devices are used to achieve functions such as efficiency analysis, benefit analysis, usage evaluation, and decision-making support for medical equipment. The study is still in its early stages, and in the future, it is expected to integrate more types of equipment, achieve rational resource allocation, and significantly impact decision-making for the development of public hospitals.
Internet of Things
;
Delphi Technique
7.Impact of Spinal Manipulative Therapy on Brain Function and Pain Alleviation in Lumbar Disc Herniation: A Resting-State fMRI Study.
Xing-Chen ZHOU ; Shuang WU ; Kai-Zheng WANG ; Long-Hao CHEN ; Zi-Cheng WEI ; Tao LI ; Zi-Han HUA ; Qiong XIA ; Zhi-Zhen LYU ; Li-Jiang LYU
Chinese journal of integrative medicine 2025;31(2):108-117
OBJECTIVE:
To elucidate how spinal manipulative therapy (SMT) exerts its analgesic effects through regulating brain function in lumbar disc herniation (LDH) patients by utilizing resting-state functional magnetic resonance imaging (rs-fMRI).
METHODS:
From September 2021 to September 2023, we enrolled LDH patients (LDH group, n=31) and age- and sex-matched healthy controls (HCs, n=28). LDH group underwent rs-fMRI at 2 distinct time points (TPs): prior to the initiation of SMT (TP1) and subsequent to the completion of the SMT sessions (TP2). SMT was administered once every other day for 30 min per session, totally 14 treatment sessions over a span of 4 weeks. HCs did not receive SMT treatment and underwent only one fMRI scan. Additionally, participants in LDH group completed clinical questionnaires on pain using the Visual Analog Scale (VAS) and the Japanese Orthopedic Association (JOA) score, whereas HCs did not undergo clinical scale assessments. The effects on the brain were jointly characterized using the amplitude of low-frequency fluctuations (ALFF) and regional homogeneity (ReHo). Correlation analyses were conducted between specific brain regions and clinical scales.
RESULTS:
Following SMT treatment, pain symptoms in LDH patients were notably alleviated and accompanied by evident activation of effects in the brain. In comparison to TP1, TP2 exhibited the most significant increase in ALFF values for Temporal_Sup_R and the most notable decrease in ALFF values for Paracentral_Lobule_L (voxelwise P<0.005; clusters >30; FDR correction). Additionally, the most substantial enhancement in ReHo values was observed for the Cuneus_R, while the most prominent reduction was noted for the Olfactory_R (voxelwise P<0.005; clusters >30; FDR correction). Moreover, a comparative analysis revealed that, in contrast to HCs, LDH patients at TP1 exhibited the most significant increase in ALFF values for Temporal_Pole_Sup_L and the most notable decrease in ALFF values for Frontal_Mid_L (voxelwise P<0.005; clusters >30; FDR correction). Furthermore, the most significant enhancement in ReHo values was observed for Postcentral_L, while the most prominent reduction was identified for ParaHippocampal_L (voxelwise P<0.005; clusters >30; FDR correction). Notably, correlation analysis with clinical scales revealed a robust positive correlation between the Cuneus_R score and the rate of change in the VAS score (r=0.9333, P<0.0001).
CONCLUSIONS
Long-term chronic lower back pain in patients with LDH manifests significant activation of the "AUN-DMN-S1-SAN" neural circuitry. The visual network, represented by the Cuneus_R, is highly likely to be a key brain network in which the analgesic efficacy of SMT becomes effective in treating LDH patients. (Trial registration No. NCT06277739).
Humans
;
Magnetic Resonance Imaging
;
Intervertebral Disc Displacement/diagnostic imaging*
;
Male
;
Female
;
Brain/diagnostic imaging*
;
Adult
;
Manipulation, Spinal/methods*
;
Middle Aged
;
Lumbar Vertebrae/physiopathology*
;
Pain Management
;
Rest
;
Case-Control Studies
8.Artificial intelligence in traditional Chinese medicine: from systems biological mechanism discovery, real-world clinical evidence inference to personalized clinical decision support.
Dengying YAN ; Qiguang ZHENG ; Kai CHANG ; Rui HUA ; Yiming LIU ; Jingyan XUE ; Zixin SHU ; Yunhui HU ; Pengcheng YANG ; Yu WEI ; Jidong LANG ; Haibin YU ; Xiaodong LI ; Runshun ZHANG ; Wenjia WANG ; Baoyan LIU ; Xuezhong ZHOU
Chinese Journal of Natural Medicines (English Ed.) 2025;23(11):1310-1328
Traditional Chinese medicine (TCM) represents a paradigmatic approach to personalized medicine, developed through the systematic accumulation and refinement of clinical empirical data over more than 2000 years, and now encompasses large-scale electronic medical records (EMR) and experimental molecular data. Artificial intelligence (AI) has demonstrated its utility in medicine through the development of various expert systems (e.g., MYCIN) since the 1970s. With the emergence of deep learning and large language models (LLMs), AI's potential in medicine shows considerable promise. Consequently, the integration of AI and TCM from both clinical and scientific perspectives presents a fundamental and promising research direction. This survey provides an insightful overview of TCM AI research, summarizing related research tasks from three perspectives: systems-level biological mechanism elucidation, real-world clinical evidence inference, and personalized clinical decision support. The review highlights representative AI methodologies alongside their applications in both TCM scientific inquiry and clinical practice. To critically assess the current state of the field, this work identifies major challenges and opportunities that constrain the development of robust research capabilities-particularly in the mechanistic understanding of TCM syndromes and herbal formulations, novel drug discovery, and the delivery of high-quality, patient-centered clinical care. The findings underscore that future advancements in AI-driven TCM research will rely on the development of high-quality, large-scale data repositories; the construction of comprehensive and domain-specific knowledge graphs (KGs); deeper insights into the biological mechanisms underpinning clinical efficacy; rigorous causal inference frameworks; and intelligent, personalized decision support systems.
Medicine, Chinese Traditional/methods*
;
Artificial Intelligence
;
Humans
;
Precision Medicine
;
Decision Support Systems, Clinical
9.Expert consensus on prognostic evaluation of cochlear implantation in hereditary hearing loss.
Xinyu SHI ; Xianbao CAO ; Renjie CHAI ; Suijun CHEN ; Juan FENG ; Ningyu FENG ; Xia GAO ; Lulu GUO ; Yuhe LIU ; Ling LU ; Lingyun MEI ; Xiaoyun QIAN ; Dongdong REN ; Haibo SHI ; Duoduo TAO ; Qin WANG ; Zhaoyan WANG ; Shuo WANG ; Wei WANG ; Ming XIA ; Hao XIONG ; Baicheng XU ; Kai XU ; Lei XU ; Hua YANG ; Jun YANG ; Pingli YANG ; Wei YUAN ; Dingjun ZHA ; Chunming ZHANG ; Hongzheng ZHANG ; Juan ZHANG ; Tianhong ZHANG ; Wenqi ZUO ; Wenyan LI ; Yongyi YUAN ; Jie ZHANG ; Yu ZHAO ; Fang ZHENG ; Yu SUN
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(9):798-808
Hearing loss is the most prevalent disabling disease. Cochlear implantation(CI) serves as the primary intervention for severe to profound hearing loss. This consensus systematically explores the value of genetic diagnosis in the pre-operative assessment and efficacy prognosis for CI. Drawing upon domestic and international research and clinical experience, it proposes an evidence-based medicine three-tiered prognostic classification system(Favorable, Marginal, Poor). The consensus focuses on common hereditary non-syndromic hearing loss(such as that caused by mutations in genes like GJB2, SLC26A4, OTOF, LOXHD1) and syndromic hereditary hearing loss(such as Jervell & Lange-Nielsen syndrome and Waardenburg syndrome), which are closely associated with congenital hearing loss, analyzing the impact of their pathological mechanisms on CI outcomes. The consensus provides recommendations based on multiple round of expert discussion and voting. It emphasizes that genetic diagnosis can optimize patient selection, predict prognosis, guide post-operative rehabilitation, offer stratified management strategies for patients with different genotypes, and advance the application of precision medicine in the field of CI.
Humans
;
Cochlear Implantation
;
Prognosis
;
Hearing Loss/surgery*
;
Consensus
;
Connexin 26
;
Mutation
;
Sulfate Transporters
;
Connexins/genetics*
10.Clinical analysis of treatment for lingual thyroglossal duct cyst with trans-oral robotic surgery.
Lanjun CAI ; Kai XU ; Chao HE ; Qimiao FENG ; Zheng LIU ; Xiang LU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(11):1034-1037
Objective:To investigate the safety, feasibility and efficacy of trans-oral robotic surgery in the treatment of lingual thyroglossal duct cyst. Methods:The clinical data of 21 patients with lingual thyroglossal duct cyst underwent trans-oral robotic surgery from May 2017 to March 2025 were analyzed retrospectively. Results:The cysts in all 21 patients were successfully excised by trans-oral robotic surgery. The mean robotic set-up and exposure time, operation time, estimated intraoperative blood loss and recovery time for oral intake were (14.3±7.2) min ([range 5.0-32.0]min), (17.0±8.4) min (range[6.0-36.0]min), (8.4±5.9) mL (range[2.0-25.0]mL) and (2.1±2.2) days (range[0-7]days), respectively. No patients required tracheostomy, and no severe postoperative complications occurred. The patients were followed up for 2 to 96 months, with median follow-up time of 47 months, and 1 recurrence was observed. Conclusion:Excision of lingual thyroglossal duct cyst by trans-oral robotic surgery is safe and feasible, with rapid recovery and low recurrence rate, which is worth popularizing in clinical practice.
Humans
;
Thyroglossal Cyst/surgery*
;
Robotic Surgical Procedures/methods*
;
Retrospective Studies
;
Female
;
Male
;
Adult
;
Treatment Outcome
;
Middle Aged
;
Adolescent

Result Analysis
Print
Save
E-mail