1.Erratum: Author correction to "The novel ER stress inducer Sec C triggers apoptosis by sulfating ER cysteine residues and degrading YAP via ER stress in pancreatic cancer cells" Acta Pharm Sin B 12 (2022) 210-227.
Junxia WANG ; Minghua CHEN ; Mengyan WANG ; Wenxia ZHAO ; Conghui ZHANG ; Xiujun LIU ; Meilian CAI ; Yuhan QIU ; Tianshu ZHANG ; Huimin ZHOU ; Wuli ZHAO ; Shuyi SI ; Rongguang SHAO
Acta Pharmaceutica Sinica B 2025;15(2):1208-1209
[This corrects the article DOI: 10.1016/j.apsb.2021.07.004.].
2.Coupling of an Au@AgPt nanozyme array with an micrococcal nuclease-specific responsiveness strategy for colorimetric/SERS sensing of Staphylococcus aureus in patients with sepsis.
Xueqin HUANG ; Yingqi YANG ; Hanlin ZHOU ; Liping HU ; Annan YANG ; Hua JIN ; Biying ZHENG ; Jiang PI ; Jun XU ; Pinghua SUN ; Huai-Hong CAI ; Xujing LIANG ; Bin PAN ; Junxia ZHENG ; Haibo ZHOU
Journal of Pharmaceutical Analysis 2025;15(2):101085-101085
Rapid and ultrasensitive detection of pathogen-associated biomarkers is vital for the early diagnosis and therapy of bacterial infections. Herein, we developed a close-packed and ordered Au@AgPt array coupled with a cascade triggering strategy for surface-enhanced Raman scattering (SERS) and colorimetric identification of the Staphylococcus aureus biomarker micrococcal nuclease (MNase) in serum samples. The trimetallic Au@AgPt nanozymes can catalyze the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) molecules to SERS-enhanced oxidized TMB (oxTMB), accompanied by the color change from colorless to blue. In the presence of S. aureus, the secreted MNase preferentially cut the nucleobase AT-rich regions of DNA sequences on magnetic beads (MBs) to release alkaline phosphatase (ALP), which subsequently mediated the oxTMB reduction for inducing the colorimetric/SERS signal fade away. Using this "on-to-off" triggering strategy, the target S. aureus can be recorded in a wide linear range with a limit of detection of 38 CFU/mL in the colorimetric mode and 6 CFU/mL in the SERS mode. Meanwhile, the MNase-mediated strategy characterized by high specificity and sensitivity successfully discriminated between patients with sepsis (n = 7) and healthy participants (n = 3), as well as monitored the prognostic progression of the disease (n = 2). Overall, benefiting from highly active and dense "hot spot" substrate, MNase-mediated cascade response strategy, and colorimetric/SERS dual-signal output, this methodology will offer a promising avenue for the early diagnosis of S. aureus infection.
3.Analysis of driver gene mutations in “Xuanwei” multi-nodular non-small cell lung cancer
WANG Xiaoxionga ; LI Quana ; SHEN Zhenghaib ; CAI Jingjinga ; LI Zhuoyinga ; SHEN Shaoconga ; LI Hongshenga ; LIU Xina ; LIU Xia ; LIU Junxia ; GUO Yinjina ; DU Yaxia ; LAN Yunyia ; MA Luyaoa ; YANG Ruijiaoa ; WU Shunxiana ; ZHOU Yongchuna ; HUANG Yunchaob
Chinese Journal of Cancer Biotherapy 2024;31(4):377-382
[摘 要] 目的:探讨多结节非小细胞肺癌(NSCLC)组织中的驱动基因突变情况与临床病理特征的关系,为多结节NSCLC患者治疗提供分子诊断依据。方法:本研究共纳入2018年1月至2023年10月间云南省肿瘤医院分子诊断中心检测的121例多结节NSCLC患者的253个肺结节肿瘤组织标本,以第二代测序(NGS)技术或扩增阻滞突变系统PCR(ARMS-PCR)技术检测多结节NSCLC 组织中驱动基因突变情况,分析其与患者临床病理特征的关系,比较不同结节间肺癌驱动基因的突变异质性。结果:与非“宣威”NSCLC相比,“宣威”多结节NSCLC患者驱动基因突变具有显著的地域特点,表现在“宣威”患者具有较低(20%)的EGFR敏感突变(L858R、19-del)及较高(27.26%)的EGFR少见突变(主要为G719/S768I、G719);“宣威”多结节NSCLC患者的KRAS突变率(27.27%)亦显著高于非“宣威”患者突变率(12.59%)(P<0.05)。此外,“宣威”多结节NSCLC患者驱动基因突变不一致率高达69.23%,远高于非“宣威”患者驱动基因突变不一致率(55.07%)(P<0.05)。结论:“宣威”多结节NSCLC患者具有较高的EGFR少见突变及KRAS突变率,同一患者不同病灶之间存在更高的驱动基因突变异质性,本研究将为“宣威”多结节NSCLC的诊疗策略提供更多的选择。
4.Research and evaluation on development model of hospice care at home and abroad
Guangwei JI ; Mingfei ZHOU ; Yuxin ZHOU ; Jinqiu ZHANG ; Junxia YANG ; Zhi ZHOU
The Journal of Practical Medicine 2024;40(7):877-886
Palliative and hospice care is an emerging medical care model for the development of modern medicine,and its emergence is not only a sign of social demand and the development of human civilization,but also an important manifestation of the change in the modern medical model.Hospice care is the final stage of palliative care,which is of great significance for the end-of-life treatment of incurable diseases.Palliative and hospice care has become an independent discipline in many countries,and its development has been rapid.However,the develop-ment of hospice and palliative care in China is not satisfactory,and the lack of money and human resources are the main reasons limiting its development.Many scholars have carried out a lot of useful practices in this regard.How to explore a road of hospice and palliative care development suitable for China′s national conditions is an urgent problem to be solved.By reviewing domestic and foreign literature,this paper summarizes the development mode and payment method of palliative and hospice care abroad,identifies the challenges encountered in the practice of hospice care in China,and draws on the development experience of palliative and hospice care in foreign countries.We aimed to identify pain points and difficulties faced in developing palliative and hospice care in China,so as to better serve patients at the end of life,gradually promote the concept of palliative and hospice care,and contribute to the sustainable development of palliative and hospice care in China.
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
6.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
7.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
8.Novel benzothiazole derivatives target the Gac/Rsm two-component system as antibacterial synergists against Pseudomonas aeruginosa infections.
Jun LIU ; Wenfu WU ; Jiayi HU ; Siyu ZHAO ; Yiqun CHANG ; Qiuxian CHEN ; Yujie LI ; Jie TANG ; Zhenmeng ZHANG ; Xiao WU ; Shumeng JIAO ; Haichuan XIAO ; Qiang ZHANG ; Jiarui DU ; Jianfu ZHAO ; Kaihe YE ; Meiyan HUANG ; Jun XU ; Haibo ZHOU ; Junxia ZHENG ; Pinghua SUN
Acta Pharmaceutica Sinica B 2024;14(11):4934-4961
The management of antibiotic-resistant, bacterial biofilm infections in skin wounds poses an increasingly challenging clinical scenario. Pseudomonas aeruginosa infection is difficult to eradicate because of biofilm formation and antibiotic resistance. In this study, we identified a new benzothiazole derivative compound, SN12 (IC50 = 43.3 nmol/L), demonstrating remarkable biofilm inhibition at nanomolar concentrations in vitro. In further activity assays and mechanistic studies, we formulated an unconventional strategy for combating P. aeruginosa-derived infections by targeting the two-component (Gac/Rsm) system. Furthermore, SN12 slowed the development of ciprofloxacin and tobramycin resistance. By using murine skin wound infection models, we observed that SN12 significantly augmented the antibacterial effects of three widely used antibiotics-tobramycin (100-fold), vancomycin (200-fold), and ciprofloxacin (1000-fold)-compared with single-dose antibiotic treatments for P. aeruginosa infection in vivo. The findings of this study suggest the potential of SN12 as a promising antibacterial synergist, highlighting the effectiveness of targeting the two-component system in treating challenging bacterial biofilm infections in humans.
9.Zooming in and out of ferroptosis in human disease.
Xue WANG ; Ye ZHOU ; Junxia MIN ; Fudi WANG
Frontiers of Medicine 2023;17(2):173-206
Ferroptosis is defined as an iron-dependent regulated form of cell death driven by lipid peroxidation. In the past decade, it has been implicated in the pathogenesis of various diseases that together involve almost every organ of the body, including various cancers, neurodegenerative diseases, cardiovascular diseases, lung diseases, liver diseases, kidney diseases, endocrine metabolic diseases, iron-overload-related diseases, orthopedic diseases and autoimmune diseases. Understanding the underlying molecular mechanisms of ferroptosis and its regulatory pathways could provide additional strategies for the management of these disease conditions. Indeed, there are an expanding number of studies suggesting that ferroptosis serves as a bona-fide target for the prevention and treatment of these diseases in relevant pre-clinical models. In this review, we summarize the progress in the research into ferroptosis and its regulatory mechanisms in human disease, while providing evidence in support of ferroptosis as a target for the treatment of these diseases. We also discuss our perspectives on the future directions in the targeting of ferroptosis in human disease.
Humans
;
Ferroptosis
;
Autoimmune Diseases
;
Cardiovascular Diseases
;
Iron
;
Musculoskeletal Diseases
10.A Phase Ⅲ Clinical Observation of Yishen Yangxin Anshen Tablets in Treatment of Insomnia with Deficiency of Heart Blood and Insufficiency of Kidney Essence
Wei WANG ; Junxia REN ; Yongzheng WANG ; Jianke HAN ; Limin YANG ; Weidong WANG ; Fengmei LIAN ; Changshan AI ; Xiaoli YIN ; Baoliang WANG ; Yi MENG ; Shuguang YUAN ; Desheng ZHOU ; Xuedong GAO
Chinese Journal of Experimental Traditional Medical Formulae 2023;29(4):110-116
ObjectiveTo confirm the clinical efficacy and safety of Yishen Yangxin Anshen tablets in the treatment of insomnia (heart-blood deficiency and kidney-essence insufficiency syndrome). MethodA randomized block, double-blind, placebo-controlled, multi-center clinical trial design method was adopted, and a total of 480 patients with insomnia due to deficiency of heart blood and insufficiency of kidney essence (treatment group-control group 3∶1) from seven hospitals (Guang'anmen Hospital, China Academy of Chinese Medical Sciences, The First Clinical Hospital, Jilin Province Academy of Traditional Chinese Medicine(TCM), The Second Affiliated Hospital of Liaoning University of TCM, The First Affiliated Hospital of Henan University of Chinese Medicine, Henan Province Hospital of TCM, Hebei General Hospital, The First Hospital of Hunan University of Chinese Medicine) were enrolled. The treatment group was given Yishen Yangxin Anshen tablets and the control group received placebo tablets (4 tablets/time, 3 times/day, 4 weeks of administration, 4 weeks of follow-up after drug withdrawal). The sleep dysfunction rating scale (SDRS) score, pittsburgh sleep quality index (PSQI) score, TCM, polysomnography (PSG) indicators from four hospital (Guang'anmen Hospital, China Academy of Chinese Medical Sciences, Henan Province Hospital of TCM, Hebei General Hospital, The First Hospital of Hunan University of Chinese Medicine), and other efficacy indicators were compared between the two groups before and after treatment. Through general physical examination, laboratory examination, and observation of adverse events, the safety of the drugs was evaluated. ResultThe baseline indexes of the two groups showed no significant difference and thus the two groups were comparable. After treatment, the total score of SDRS in the treatment group was lower than that in the control group (P<0.01). After drug withdrawal for 4 weeks, the total score of SDRS demonstrated no significant change in the treatment group as compared with that at the end of treatment, indicating that the rebound change of curative effect was not obvious. After treatment, the total score of PSQI in the treatment group decreased as compared with that in the control group (P<0.01), and the change of total score of PSQI in the treatment group was statistically significant (P<0.05) after drug withdrawal for 4 weeks but small, indicating that the rebound change of curative effect was not obvious. After treatment, the total effective rate about the TCM symptoms in the treatment group was higher than that in the control group (χ2=137.521,P<0.01). After treatment, the disappearance rates of single indexes in the treatment group, such as difficulty in falling asleep, easily waking up after sleeping, early awakening, short sleep time, dreamfulness, palpitation, forgetfulness, dizziness, mental fatigue, and weakness of waist and knee, increased compared with those in the control group (P<0.01). After treatment, the treatment group demonstrated fewer awaking times (AT), longer total sleep time (TST), lower ATA/TST ratio, and higher sleep efficiency (%) than the control group (P<0.05). No abnormal value or aggravation related to drugs was observed in either group. The incidence of adverse events in the treatment group and the control group was 5.57% and 8.40% respectively. No serious adverse events or adverse events leading to withdrawal happened in either group. ConclusionYishen Yangxin Anshen tablets is effective and safe for patients with insomnia of deficiency of heart-blood and insufficiency of kidney-essence.

Result Analysis
Print
Save
E-mail