1.Evaluation on repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure
Yue PENG ; Ping ZHAO ; Juan TAN ; Rui LIU ; Yiping ZHENG ; Jiangping HUANG
International Eye Science 2025;25(3):494-498
AIM: To evaluate the repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure(IOP)by comparing the correlation and difference with Goldmann applanation tonometry(GAT)and non-contact tonometer(NCT), and to compare the correlation of the three types of IOP measurement with the central corneal thickness(CCT).METHODS: Prospective study. A total of 90 outpatients(90 eyes)in Liaoning Aier Eye Hospital from March 2019 to May 2019 were randomly selected as study subjects. All patients were measured IOP using iCare IC100, NCT, and GAT. The interclass correlation coefficient(ICC)was used to evaluate the repeatability of IOP measured 3 times consecutively using an intraocular tonometer. The correlation and consistency of iCare IC100, GAT and NCT were compared by one-way ANOVA, Pearson linear correlation analysis and Bland-Altman analysis. The linear regression analysis was used to analyze the correlation of the three tonometers with CCT.RESULTS: The mean IOP measured with iCare IC100, GAT and NCT was 19.74±6.90, 19.88±7.07 and 18.47±6.31 mmHg, respectively(F=1.180, P=0.309). The measurements of iCare IC100 with GAT, iCare IC100 with NCT and GAT with NCT were all positively correlated(r=0.930, 0.946, 0.918, all P<0.05), the Bland-Altman analysis showed that the mean differences between iCare IC100 and GAT, iCare IC100 and NCT, GAT and NCT were -0.142±2.61, 1.27±2.24, and 1.41±2.81 mmHg, respectively, with 97%(87/90), 96%(86/90), and 97%(87/90)IOP differences distributed within their 95% confidence intervals. The IOP measured with iCare IC100 and CCT, GAT and CCT and NCT and CCT were all positively correlated(r=0.426, 0.353, 0.451, all P<0.01). The linear regression equations between iCare IC100, GAT and NCT measurement and CCT were iCare IC100 IOP=-19.62+0.074×CCT; GAT IOP=-13.54+0.063×CCT; NCT IOP=-19.65+0.072×CCT; that is, for every 10 μm increase in CCT, iCare IC100 measurement increased by 0.74 mmHg, GAT measurement increased by 0.63 mmHg, and NCT measurement increased by 0.72 mmHg.CONCLUSION: The iCare IC100 tonometer has good repeatability and accuracy in measuring IOP, and the CCT has a greater impact on the measurement of iCare IC100 than the GAT and NCT.
2.Evaluation on repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure
Yue PENG ; Ping ZHAO ; Juan TAN ; Rui LIU ; Yiping ZHENG ; Jiangping HUANG
International Eye Science 2025;25(3):494-498
AIM: To evaluate the repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure(IOP)by comparing the correlation and difference with Goldmann applanation tonometry(GAT)and non-contact tonometer(NCT), and to compare the correlation of the three types of IOP measurement with the central corneal thickness(CCT).METHODS: Prospective study. A total of 90 outpatients(90 eyes)in Liaoning Aier Eye Hospital from March 2019 to May 2019 were randomly selected as study subjects. All patients were measured IOP using iCare IC100, NCT, and GAT. The interclass correlation coefficient(ICC)was used to evaluate the repeatability of IOP measured 3 times consecutively using an intraocular tonometer. The correlation and consistency of iCare IC100, GAT and NCT were compared by one-way ANOVA, Pearson linear correlation analysis and Bland-Altman analysis. The linear regression analysis was used to analyze the correlation of the three tonometers with CCT.RESULTS: The mean IOP measured with iCare IC100, GAT and NCT was 19.74±6.90, 19.88±7.07 and 18.47±6.31 mmHg, respectively(F=1.180, P=0.309). The measurements of iCare IC100 with GAT, iCare IC100 with NCT and GAT with NCT were all positively correlated(r=0.930, 0.946, 0.918, all P<0.05), the Bland-Altman analysis showed that the mean differences between iCare IC100 and GAT, iCare IC100 and NCT, GAT and NCT were -0.142±2.61, 1.27±2.24, and 1.41±2.81 mmHg, respectively, with 97%(87/90), 96%(86/90), and 97%(87/90)IOP differences distributed within their 95% confidence intervals. The IOP measured with iCare IC100 and CCT, GAT and CCT and NCT and CCT were all positively correlated(r=0.426, 0.353, 0.451, all P<0.01). The linear regression equations between iCare IC100, GAT and NCT measurement and CCT were iCare IC100 IOP=-19.62+0.074×CCT; GAT IOP=-13.54+0.063×CCT; NCT IOP=-19.65+0.072×CCT; that is, for every 10 μm increase in CCT, iCare IC100 measurement increased by 0.74 mmHg, GAT measurement increased by 0.63 mmHg, and NCT measurement increased by 0.72 mmHg.CONCLUSION: The iCare IC100 tonometer has good repeatability and accuracy in measuring IOP, and the CCT has a greater impact on the measurement of iCare IC100 than the GAT and NCT.
3.Exploration of radiotherapy as a combined treatment modality with in situ vaccines in the treatment of advanced soft tissue sarcomas
TAN Siyi, ; WANG Xiaolu ; WANG Qin ; DU Shiyao ; YIN Fangtao ; YANG Yiqi ; SUN Wu ; LIU Juan ; ZHOU Xia ; LIU Baorui, ; LI Rutian
Chinese Journal of Cancer Biotherapy 2025;32(4):418-424
[摘 要] 目的:评估放疗作为原位疫苗的联合治疗模式在晚期软组织肉瘤(STS)患者中的有效性和安全性。方法:回顾性分析2020年12月至2024年9月期间在南京大学医学院附属鼓楼医院肿瘤中心接受联合治疗模式的12例晚期STS患者的临床资料。12例患者均接受了联合治疗。放疗主要以大分割为主。靶向治疗:安罗替尼10例、阿帕替尼2例。免疫治疗以PD-1抗体为主。主要研究终点为疾病控制率(DCR),次要研究终点为客观有效率(ORR)及安全性。结果:接受联合治疗的12例STS患者中有0例CR,4例PR,7例SD,1例PD。ORR为33%,DCR为91.7%,其中靶病灶的DCR为100%。12例患者中,9例出现Ⅰ~Ⅱ级不良反应。最常发生的血液学不良反应是贫血(6例)、肝功能检查结果异常(3例)。最常发生的非血液学不良反应是尿蛋白(5例)、高血压(4例)、甲状腺功能异常(3例)、厌食(3例)、恶心呕吐(2例);仅2例发生Ⅲ级血液毒性,有1例发生Ⅲ级气胸。结论:放疗作为原位疫苗的联合治疗模式在晚期STS患者中展现出较高的DCR,且未出现严重不良反应。该联合治疗模式具有良好的有效性与安全性。
4.Standardized training guidelines for the clinical application of ventricular assist devices in Shanghai
Jing CAI ; Qingrong TANG ; Xiaoning SUN ; Dingqian LIU ; Ming TAN ; Juan HUANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(04):437-441
According to the "Regulations on clinical application management of medical technologies", physicians intending to carry out restricted technologies must undergo standardized training and pass assessments in accordance with the clinical application management standards for the respective technology. As ventricular assist technology is classified as a nationally restricted technology, standardized training is one of the essential conditions for its application. This paper primarily explores the standardized training for the clinical application of ventricular assist technology in Shanghai, in light of its background, clinical application, and current training status. It proposes the training requirements for ventricular assist technology, animal training assessment standards, and clinical practice assessment standards in Shanghai, aiming to promote the standardized development and high-quality advancement of ventricular assist technology in Shanghai.
5.Blood transfusion in elective gynecological surgeries in the Philippines: A multicenter study
Maria Antonia E. Habana ; Ma. Carmen H. Quevedo ; Elisa O. Tiu ; Maria Corazon Zaida Noblejas Gamilla ; Madonna Victoria C. Domingo ; Maria Virginia S. Abalos ; Maria Lourdes K. Otayza ; Amelia A. Vega ; Lynnette R. Lu-lasala ; Czarina Juliana L. Alcaraz ; Efren J. Domingo ; Nancy Marie S. Gamo ; Delfin A. Tan
Philippine Journal of Obstetrics and Gynecology 2025;49(2):106-113
BACKGROUND
Intraoperative transfusion for gynecologic surgery, when appropriately used, can improve patient outcomes. However, when utilized incorrectly, blood transfusion can worsen patient outcomes and increase patient cost. This study aimed to evaluate the blood transfusion practices of tertiary hospitals in the Philippines.
METHODSThe study utilized a cross-sectional design wherein prospective data were gathered through multiple sources across seven tertiary-level hospitals. Women admitted to undergo gynecologic surgery were recruited based on a set of criteria. A chart review was conducted, and blood utilization indices were calculated. Outcomes were compared between public versus private facilities and transfused versus nontransfused patients.
RESULTSAmong 514 patients, 79.7% underwent cross-matching and 75.1% received transfusions. Adverse events were rare, with no transfusion-related deaths. The overall crossmatch-to-transfusion ratio (C/T ratio) was 2.8, exceeding the 2.5 optimal benchmark; all public hospitals recorded a C/T ratio >2.5, whereas private centers had more efficient usage. Six hospitals met acceptable benchmarks for transfusion probability and transfusion index. Open abdominal procedures, particularly hysterectomy, accounted for the most blood used. Transfused patients had longer operative times, greater blood loss, lower preoperative hemoglobin, and more frequently involved resident physicians in training. Public hospitals recorded higher cross-match and transfusion rates, greater resident physician participation, and broader use of general anesthesia.
CONCLUSIONResults of the study highlight the importance of monitoring blood transfusion parameters to optimize blood utilization. The observed differences between public and private institutions in the country highlight the urgent need for standardized and evidence-based practice to ensure efficient transfusion protocols nationwide.
Human ; Female ; Blood Transfusion
6.Clinical efficacy of Liwen procedure for obstructive hypertrophic cardiomyopathy: A retrospective study in a single center
Shuai WANG ; Juan TAN ; Hongyan XIAO ; Liang TAO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(06):819-823
Objective To analyze the changes in myocardial injury markers and cardiac function in patients with hypertrophic obstructive cardiomyopathy (HOCM) after Liwen surgery. Methods A retrospective analysis was conducted on the clinical data of HOCM patients who underwent Liwen surgery at the Department of Cardiac Surgery, Wuhan Asia Heart Hospital from December 2019 to April 2023, mainly including preoperative and postoperative dynamic follow-up laboratory test results and echocardiograms. Results A total of 42 patients were included, with 25 males and 17 females, aged (44.76±17.72) years, and a postoperative follow-up time of (15.02±6.97) months. The myocardial troponin level of the patients decreased from preoperative 0.03 (0.02, 0.06) ng/mL to postoperative 0.02 (0.01, 0.05) ng/mL (P=0.006), and the N-terminal pro-brain natriuretic peptide level decreased from preoperative 748.95 (337.40, 1600.75) ng/L to postoperative 367.15 (126.93, 1030.25) ng/L (P<0.001). After surgery, the left atrial diameter of the patients decreased from preoperative (4.18±0.57) cm to postoperative (3.93±0.55) cm (P=0.004), the end-diastolic interventricular septum thickness decreased from preoperative 2.25 (1.90, 2.75) cm to postoperative 1.70 (1.50, 1.90) cm (P<0.001), the left ventricular mass index decreased from preoperative 211.73 (172.28, 261.54) g/m2 to postoperative 156.78 (132.34, 191.36) g/m2 (P<0.001), the left ventricular weight decreased from preoperative 368.89 (292.34, 477.72) g to postoperative 266.62 (224.57, 326.04) g (P<0.001), the end-diastolic posterior wall thickness of the left ventricle decreased from preoperative 1.30 (1.20, 1.60) cm to postoperative 1.20 (1.18, 1.40) cm (P<0.001), the relative wall thickness decreased from preoperative 0.78 (0.78, 1.02) to postoperative 0.63 (0.56, 0.72) (P<0.001), the end-systolic inner diameter of the left ventricle increased from preoperative (2.91±0.50) cm to postoperative (3.19±0.53) cm (P=0.001), and the end-diastolic inner diameter of the left ventricle increased from preoperative (4.41±0.48) cm to postoperative (4.66±0.52) cm (P=0.005). The left ventricular outflow diameter increased from preoperative (1.28±0.46) cm to postoperative (1.57±0.32) cm (P=0.001), the left ventricular outflow pressure gradient decreased from preoperative 58.50 (40.75, 92.50) mm Hg to postoperative 11.50 (7.75, 20.50) mm Hg (P<0.001), the left ventricular ejection fraction increased from preoperative 60.00% (56.75%, 65.00%) to postoperative 63.00% (62.00%, 66.00%) (P=0.024), and the degree of systolic anterior motion of the mitral valve leaflets decreased (P<0.001). Conclusion The cardiac function of patients with HOCM is improved after Liwen surgery, myocardial injury marker levels are decreased, cardiac reverse remodeling occurres, and the surgical outcome is good.
7.LncRNA SNHG14 affects the malignant biological behaviors of hepatocellular carcinoma Huh7 cells via targeting the miR-579-3p/SPARC axis
CHEN Aifang ; TIAN Xia ; HAN Zheng ; YAN Juan ; TAN Jie
Chinese Journal of Cancer Biotherapy 2025;32(9):920-926
[摘 要] 目的:探究长链非编码RNA(lncRNA)小核仁RNA宿主基因14(SNHG14)靶向miR-579-3p/富含半胱氨酸的酸性分泌蛋白(SPARC)对肝细胞癌(HCC)细胞恶性生物学行为的影响。方法:常规培养人正常肝细胞(LO2)和HCC细胞Huh7、Hep3B、HepG2,将Huh7细胞随机分为对照组、sh-NC组、sh-SNHG14组、sh-SNHG14 + anti-NC组和sh-SNHG14 + anti-miR-579-3p组,qPCR法检测细胞中SNHG14、miR-579-3p和SPARC mRNA的表达水平,双萤光素酶报告基因实验验证SNHG14与miR-579-3p及miR-579-3p与SPARC调控关系,MTT法、划痕愈合实验、Transwell实验、流式细胞术,以及WB法分别检测各组Huh7细胞的增殖、迁移、侵袭能力、凋亡,以及Huh7细胞中PCNA、E-cadherin、vimentin、SPARC蛋白的表达。结果:在HCC细胞中SNHG14、SPARC mRNA呈高表达、miR-579-3p呈低表达(均P < 0.05);SNHG14与miR-579-3p和miR-579-3p与SPARC mRNA间存在直接结合调控关系(均P < 0.05)。敲减SNHG14可明显抑制Huh7细胞的增殖、迁移、侵袭、PCNA、vimentin、SPARC mRNA及蛋白的表达(均P < 0.05),促进细胞凋亡、miR-579-3p和E-cadherin表达(均P < 0.05);抑制miR-579-3p则可部分逆转敲减SNHG14对Huh7细胞的作用(均P < 0.05)。结论:敲减SNHG14可通过靶向miR-579-3p/SPARC轴抑制Huh7细胞的恶性生物学行为,促进其凋亡;SNHG14和miR-579-3p/SPARC轴可能是HCC治疗的潜在靶点。
8.Bridging policy and practice: A qualitative study on PhilHealth claims and financial processes in public hospitals.
Meljun R. BANOGON ; Geremiah Edison Daniel C. LLANES ; Juan Maria Pablo R. NAÑAGAS ; Jaime Z. GALVEZ-TAN
Philippine Journal of Health Research and Development 2025;29(3):79-90
BACKGROUND
PhilHealth serves as the Philippines’ national health insurance provider and is central to implementing the Universal Health Care (UHC) Law. Despite this, existing gaps and ongoing challenges in claims and financial management systems continue to affect public healthcare facilities’ operations and sustainability.
AIMS AND OBJECTIVESThis article examined the effectiveness and challenges of PhilHealth’s claims and financial management systems in public healthcare facilities, focusing on accreditation, claims processing, reimbursements, and financial governance.
MATERIALS AND METHODSA qualitative multiple-case study design was employed in Quezon City and the provinces of La Union, Sorsogon, Leyte, and Bukidnon, with data collected from 2022 to 2023. Prior to data collection, a certificate of exemption was granted by the Department of Health – Single Joint Research Ethics Board (DOH-SJREB). Data were collected through key informant interviews with healthcare facility heads, claims processors, and PhilHealth personnel, supplemented by document reviews and facility observations. Thematic analysis was employed to examine the implementation of national health insurance policies at the facility level.
RESULTSAccreditation standards are uniformly defined, yet compliance varies widely, directly influencing reimbursement outcomes. Facilities with compliance gaps often face provisional accreditation, downgrades, or suspension, resulting in reduced revenue. Although the Universal Health Care (UHC) Law guarantees patient access to PhilHealth benefits, the efficiency of claims processing remains uneven and highly dependent on administrative capacity, staffing adequacy, and digital infrastructure. Systemic inefficiencies at both PhilHealth and facility levels contribute to delays and claim denials. Reimbursements are further constrained by outdated case rate ceilings, inconsistent financial practices, inadequate recordkeeping, weak information systems, and poor storage conditions—particularly in lower-level hospitals and rural health units.
CONCLUSIONReforms in claims processing workflows, information system integration, and financial management capacities are crucial to enhance reimbursement efficiency. Strengthening these systems is fundamental for supporting sustainable, equitable, and high-quality healthcare delivery in the public sector within the Universal Health Care (UHC) framework.
Human ; Insurance, Health ; Hospitals, Public ; Delivery Of Health Care ; Universal Health Care ; National Health Programs
9.Pharmacokinetics of JS026 and JS026-JS016 for single intravenous administration in healthy volunteers
Yan TIAN ; Hui-Jing YE ; Jing-Jing WANG ; Nan-Yang LI ; Juan MA ; Xi TAN ; Fan WU ; Jie WANG ; Shu-Yan YU ; Xiao-Jie WU ; Jin-Jie HE ; Jing ZHANG ; Wen-Hong ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(15):2251-2255
Objective To evaluate tolerability,safety and pharmacokinetics of JS026 and JS026-JS016 single dose intravenous infusion in healthy adults.Methods This phase 1,randomized,double-blind,placebo-controlled,dose-escalation study totally included 48 participants:32 healthy subjects were enrolled in JS026 single intravenous infusion groups and 16 healthy subjects were enrolled in JS026-JS016 groups.JS026 was sequentially administered from low dose to high dose(30-1 000 mg),with intravenous infusion of JS026 or placebo in JS026 single-dose groups,and intravenous infusion of JS026-JS016 or placebo in the combination drug groups.Blood was collected according to the time point designed for trial.Serum concentrations of JS026 and JS016 were determined by enzyme linked immunosorbnent assay(ELISA),and pharmacokinetics parameters were calculated by WinNonlin 8.2.The power model method was used to evaluate the linear analysis of dose and drug exposure.Results 47 subjects completed trial and 1 subject lost to follow-up.After a single intravenous injection of JS026 of 30 mg,100 mg,300 mg,600 mg,and 1 000 mg,mean Cmax were(9.47±1.53),(33.20±4.95),(96.10±13.70),(177.00±22.20)and(353.00±56.70)μg·mL-1,respectively;mean AUC0-∞ were(4 225.00±607.00),(1.78 × 104±3 268.00),(5.83 × 104±1 038.00),(1.07 × 105±152.00),(1.66 × 105±327.00)μg·h·mL-1,respectively;mean t1/2 of JS026 were 563-709 h.The Cmax and AUC0-∞ of JS026 were basically similar alone or in combination with JS016.The results of Power model showed that Cmax and AUC0-∞ increased approximately linearly with the increasing dose of JS026.Treatment emergent adverse event was not increasing when dose increased and most of adverse event associated with drugs were abnormal on laboratory tests and haematuria,thus JS026 and JS016 was well tolerated in all groups.Conclusion The single intravenous infusion of JS026 can almost be thought to be a linear relationship between the doses and drug serum exposure.JS016 had no significant effect on serum concentration of JS026 and JS026 was well tolerated and safe in healthy subjects within 30-1 000 mg.
10.Relationship among insomnia symptoms,neuroticism,anxiety symptoms and psychological capital in patients with COVID-19
Wenkai ZHENG ; Chunni HENG ; Yunlong TAN ; Juan DU ; Shuo FENG ; Jiao FANG
Chinese Mental Health Journal 2024;38(2):151-157
Objectives:To explore the relationship between insomnia symptoms and neuroticism in patients with COVID-19,and to explore the role of anxiety and psychological capital in the relationship.Methods:Totally 687 patients with COVID-19 were recruited from Shanghai Fangcang Hospital.The Athens Insomnia Scale(AIS),Eysenck Personality Questionnaire-Revised Short Scale for Chinese Neuroticism Subscale(EPQ-RSC-N),Self-Rat-ing Anxiety Scale(SAS)and Psychological Capital Questionnaire(PCQ)were used to measure insomnia symp-toms,neuroticism personality trait,anxiety symptoms and psychological capital levels.The deviation-corrected per-centile Bootstrap method was used to test the mediating effect,and the PROCESS program was used to test the moderated effect.Results:The detection rate of insomnia symptoms was 49.93%.The AIS scores were lower in male patients than in female patients(P<0.01).The SAS scores partly mediated the relationship between neuroti-cism scores and AIS scores,with an effect size of 0.03,accounting for 18.29%of the total effect.With the im-provement of PCQ scores,the predictive effect of SAS scores on AIS scores gradually decreased(β=-0.01,t=-4.41,P<0.001).Conclusions:Anxiety symptoms in patients with COVID-19 play a partial mediating role in the positive relationship between insomnia symptoms and neuroticism.The psychological capital moderates the relation-ship between insomnia and anxiety symptoms.


Result Analysis
Print
Save
E-mail