1.Application effect evaluation of patient service intelligent management platform based on one hospital and multiple districts
Hanxu LANG ; Peipei JIA ; Lianfang LU ; Juan FENG ; Houping ZHAO ; Lili WEI
Modern Hospital 2025;25(3):417-421
Objective The sample hospital is currently in the exploration stage of creating patient satisfaction service un-der the one-hospital and multi-district management mode.In order to improve the overall feeling of patients in the process of hos-pital treatment,the application effect of the existing all-round full-cycle patient service intelligent management platform in the hos-pital is quantitatively evaluated,so as to better improve the service mode.Methods A survey was conducted to collect satisfac-tion data from two groups:the experimental group,which utilized the comprehensive and full-cycle patient service intelligent man-agement platform for diagnosis and treatment services,and the control group,which followed the conventional patient admission and discharge process.The work efficiency number was obtained and calculated through the background of the system,including the average time to handle hospitalization procedures,the average waiting time for examination,the average time to handle dis-charge procedures,the time spent on each follow-up visit and the response rate of follow-up patients.The data were analyzed sta-tistically.Results The work efficiency of the experimental group was significantly better than that of the control group,and the satisfaction of hospitalized patients and staff was higher than that of the control group.Conclusion The application of the com-prehensive and full-cycle patient service intelligent management platform can improve the satisfaction of patients and staff,opti-mize the efficiency of treatment,and better serve the management mode of one hospital and multiple districts.
2.Application effect evaluation of patient service intelligent management platform based on one hospital and multiple districts
Hanxu LANG ; Peipei JIA ; Lianfang LU ; Juan FENG ; Houping ZHAO ; Lili WEI
Modern Hospital 2025;25(3):417-421
Objective The sample hospital is currently in the exploration stage of creating patient satisfaction service un-der the one-hospital and multi-district management mode.In order to improve the overall feeling of patients in the process of hos-pital treatment,the application effect of the existing all-round full-cycle patient service intelligent management platform in the hos-pital is quantitatively evaluated,so as to better improve the service mode.Methods A survey was conducted to collect satisfac-tion data from two groups:the experimental group,which utilized the comprehensive and full-cycle patient service intelligent man-agement platform for diagnosis and treatment services,and the control group,which followed the conventional patient admission and discharge process.The work efficiency number was obtained and calculated through the background of the system,including the average time to handle hospitalization procedures,the average waiting time for examination,the average time to handle dis-charge procedures,the time spent on each follow-up visit and the response rate of follow-up patients.The data were analyzed sta-tistically.Results The work efficiency of the experimental group was significantly better than that of the control group,and the satisfaction of hospitalized patients and staff was higher than that of the control group.Conclusion The application of the com-prehensive and full-cycle patient service intelligent management platform can improve the satisfaction of patients and staff,opti-mize the efficiency of treatment,and better serve the management mode of one hospital and multiple districts.
3.Impact of the number of microsatellite markers on the analysis of population genetic diversity of Schistosoma japonicum
Juan LONG ; Lang MA ; Hongying ZONG ; Zhipeng ZHOU ; Hao YAN ; Qinping ZHAO
Chinese Journal of Schistosomiasis Control 2025;37(3):239-246
Objective To examine the impact of different numbers of microsatellite markers on the analysis of population genetic diversity of Schistosoma japonicum, so as to provide insights into studies on the population genetic diversity of S. japonicum. Methods Oncomelania hupensis snails were collected from a wasteland in Gong’an County, Hubei Province, and 37 S. japonicum-infected O. hupensis snails were identified using the cercarial shedding method. A single cercaria released from each S. japonicum-infected O. hupensis snail was collected, and 10 cercariae were randomly collected from DNA extraction. Nine previously validated microsatellite loci and 15 additional microsatellite loci screened from literature review and the GenBank database and confirmed with stable amplification efficiency were selected as molecular markers. Genomic DNA from cercariae was subjected to three multiplex PCR amplifications of microsatellite markers with the Type-it Microsatellite PCR kit, and genotyped using capillary electrophoresis. The population genetic diversity of S. japonicum cercariae DNA was analyzed with observed number of alleles (Na), effective number of alleles (Ae), observed heterozygosity (Ho), expected heterozygosity (He), and polymorphism information content (PIC), and tested for Hardy-Weinberg equilibrium (HWE) and linkage disequilibrium (LD). To further investigate the impact of the number of microsatellite loci on the population genetic diversity of S. japonicum, the number of microsatellite markers was sequentially assigned from 1 to 24, and the mean and standard deviation of Na were calculated for S. japonicum populations at different locus numbers. In addition, the coefficient of variation (CV) of allelic number (defined as the ratio of the standard deviation to the mean) was determined, and the variation in Na with increasing microsatellite locus numbers was analyzed. Results Genomic DNA from 345 S. japonicum cercariae was selected for genotyping of 24 microsatellite markers, and all 24 microsatellite loci met linkage equilibrium (standardized linkage disequilibrium coefficient D′ < 0.7, r2 < 0.3) and deviated from Hardy-Weinberg equilibrium (P < 0.001). The mean Na, Ae, Ho and He were 27.46 ± 2.18, 12.46 ± 0.95, 0.46 ± 0.03, and 0.91 ± 0.01 for 24 microsatellite loci in S. japonicum cercarial populations, respectively, and PIC ranged from 0.85 to 0.96, indicating high genome-wide representativeness of 24 microsatellite loci. The mean value of Na-Ae was higher in genotyping with 9 previously validated microsatellite loci (19.88 ± 8.43) than with all 24 loci (14.99 ± 8.09). As the number of microsatellite loci increased, the mean Na showed no significant variation; however, the standard deviation gradually decreased. Notably, if the locus number reached 18 or more, the variation in the standard deviation of Na remarkably reduced. In addition, the standard deviation of Na at 18 loci was less than 5% of the mean Na at 24 loci, with a CV of 4.6%. Conclusions The number of microsatellite loci significantly affects the population genetic diversity analysis of S. japonicum. Eighteen or more microsatellite loci are recommended for analysis of the population genetic diversity of S. japonicum under the current conditions of low-prevalence infection and unbalanced genetic distribution of S. japonicum.
4.Comparative study on waiting time and treatment time variability of different appointment regimens for radiotherapy patients
Shoupeng LIU ; Jialu LAI ; Linghui ZHOU ; Yang HUANG ; Juan HU ; Xianghua ZENG ; Zhihong XUE ; Guilin ZENG ; Lang HE
Chinese Journal of Radiation Oncology 2025;34(2):160-166
Objective:To compare the effects of different appointment regimens on the daily waiting time, fixedness of treatment time and lateness rate of radiotherapy patients.Methods:Medical records of 5488 radiotherapy from 332 patients on the same linear accelerator in West China Hospital of Sichuan University from March to June 2022 were selected. Based on the radiotherapy information integration platform of MOSAIQ, all patients were randomly assigned to the morning class, afternoon class and evening class. Traditional manual appointment regimen was adopted for the morning class, 30 min appointment regimen for the afternoon class, and 15 min appointment regimen for the evening class, respectively. The differences in patient waiting time for treatment, fixedness of treatment time, and lateness rate under different appointment regimens were compared. The fixedness of treatment time and waiting time was determined by one-way ANOVA, and the 2×3 Chi-square test was adopted for the lateness rate. Results:The waiting time in the 15 min appointment, the 30 min appointment and manual appointment groups were (27.08 ± 17.21), (34.57± 19.12) and (41.50 ±20.94) min, respectively. There was statistical significance among three appointment regimens ( F=254.97, P<0.001). The waiting time was the shortest in the 15 min appointment group, followed by the 30 min appointment group, and the manual appointment group (all P<0.001 for two-group comparison). The fixedness of treatment time in the 15 min appointment, the 30 min appointment and the manual appointment groups were (15.60±7.87), (18.69±8.94) and (24.30±15.10) min, respectively. There was statistical significance among three groups ( F=25.23, P<0.001). Among them, the fixedness of treatment time in the 15 min appointment group was the highest, followed by the 30 min appointment group, and the manual appointment group (all P<0.001). The lateness rates in the 15 min appointment, the 30 min appointment and the manual appointment groups were 5.7%, 6.2% and 9.6%, respectively. The lateness rate in the manual appointment group was higher than those in the 15 min appointment and the 30 min appointment groups ( χ2=19.24、14.90, both P<0.001), but there was no statistical significance in the lateness rate between the 15 min appointment and 30min appointment groups ( χ2=0.39, P=0.535). Conclusion:In the clinical practice of conventional intensity-modulated radiotherapy technology carried out by conventional linear accelerator, the 15 min appointment regimen can shorten the waiting time for radiotherapy and improve the fixedness of daily radiotherapy time, which is worthy of clinical promotion.
5.A new sesquiterpenoid from fresh herb of Centipeda minima.
Qi-Ji LI ; Liu YANG ; Li WANG ; Lang ZHOU ; Yan YANG ; Juan YANG
China Journal of Chinese Materia Medica 2025;50(7):1803-1809
Eleven sesquiterpenoids were isolated from the petroleum ether and ethyl acetate extracted fraction of 95% ethanol extract of fresh Centipeda minima by using modern chromatographic separation techniques such as silica gel, MCI, gel, and semi-preparative liquid chromatography. Their structures were identified using spectroscopy and nuclear magnetic resonance(NMR) calculation as minimin A(1), brevilin A(2), minimolide L(3), minimolide A(4), minimolide B(5), arnicolide D(6), microhelenin C(7), 2β-hydroxyl-2,3-dihydrogen-6-O-angeloylplenolin(8), 11α,13-dihydroarnifolin(9),(1S,2R,5R,6S,7S,8S,10R)-6-hydroxy-2-ethoxy-4-oxopseudoguai-11(13)-en-12,8-olide(10), and pulchellin-2-O-isovalerate(11), among which compound 1 was a new compound, and compounds 9-11 were isolated from Centipeda for the first time. The evaluation results of in vitro anti-inflammatory activity showed that compounds 1-11 possessed significant anti-inflammatory activity, with IC_(50) values ranging from(0.13±0.03) to(13.11±0.17) μmol·L~(-1).
Sesquiterpenes/pharmacology*
;
Animals
;
Asteraceae/chemistry*
;
Mice
;
Drugs, Chinese Herbal/pharmacology*
;
Molecular Structure
;
Magnetic Resonance Spectroscopy
;
Macrophages/immunology*
6.Comparative study on waiting time and treatment time variability of different appointment regimens for radiotherapy patients
Shoupeng LIU ; Jialu LAI ; Linghui ZHOU ; Yang HUANG ; Juan HU ; Xianghua ZENG ; Zhihong XUE ; Guilin ZENG ; Lang HE
Chinese Journal of Radiation Oncology 2025;34(2):160-166
Objective:To compare the effects of different appointment regimens on the daily waiting time, fixedness of treatment time and lateness rate of radiotherapy patients.Methods:Medical records of 5488 radiotherapy from 332 patients on the same linear accelerator in West China Hospital of Sichuan University from March to June 2022 were selected. Based on the radiotherapy information integration platform of MOSAIQ, all patients were randomly assigned to the morning class, afternoon class and evening class. Traditional manual appointment regimen was adopted for the morning class, 30 min appointment regimen for the afternoon class, and 15 min appointment regimen for the evening class, respectively. The differences in patient waiting time for treatment, fixedness of treatment time, and lateness rate under different appointment regimens were compared. The fixedness of treatment time and waiting time was determined by one-way ANOVA, and the 2×3 Chi-square test was adopted for the lateness rate. Results:The waiting time in the 15 min appointment, the 30 min appointment and manual appointment groups were (27.08 ± 17.21), (34.57± 19.12) and (41.50 ±20.94) min, respectively. There was statistical significance among three appointment regimens ( F=254.97, P<0.001). The waiting time was the shortest in the 15 min appointment group, followed by the 30 min appointment group, and the manual appointment group (all P<0.001 for two-group comparison). The fixedness of treatment time in the 15 min appointment, the 30 min appointment and the manual appointment groups were (15.60±7.87), (18.69±8.94) and (24.30±15.10) min, respectively. There was statistical significance among three groups ( F=25.23, P<0.001). Among them, the fixedness of treatment time in the 15 min appointment group was the highest, followed by the 30 min appointment group, and the manual appointment group (all P<0.001). The lateness rates in the 15 min appointment, the 30 min appointment and the manual appointment groups were 5.7%, 6.2% and 9.6%, respectively. The lateness rate in the manual appointment group was higher than those in the 15 min appointment and the 30 min appointment groups ( χ2=19.24、14.90, both P<0.001), but there was no statistical significance in the lateness rate between the 15 min appointment and 30min appointment groups ( χ2=0.39, P=0.535). Conclusion:In the clinical practice of conventional intensity-modulated radiotherapy technology carried out by conventional linear accelerator, the 15 min appointment regimen can shorten the waiting time for radiotherapy and improve the fixedness of daily radiotherapy time, which is worthy of clinical promotion.
7.Transcatheter Aortic Valve Replacement in Patients With Pure Native Aortic Regurgitation: Results From a Multicenter Registry Study
Xiaofei GAO ; Juan ZHANG ; Xiangquan KONG ; Jing CHEN ; Xiang CHEN ; Longyan ZHANG ; Xinyong CAI ; Jiancheng ZHU ; Nailiang TIAN ; Zhen GE ; Bin WANG ; Qing ZHOU ; Xi SU ; Lang HONG ; Yan WANG ; Hong JIANG ; Junjie ZHANG ; Shaoliang CHEN
Cardiology Discovery 2024;04(2):134-141
Objective::Patients with untreated severe aortic regurgitation (AR) have a high risk of mortality. Transfemoral transcatheter aortic valve replacement (TF-TAVR) is a treatment option for AR; however, the safety and efficacy of this technique have not been sufficiently established. This study aimed to evaluate the clinical and anatomical variables correlating with device success of TF-TAVR using a self-expanding valve system for pure AR.Methods::Patients with pure native severe AR who underwent TF-TAVR using a self-expanding valve system were registered at 5 Chinese centers. The primary endpoint was device success at 1 month after TAVR. The secondary endpoint was the composite of major adverse cardiovascular events (MACE) at 6 months, including all-cause death, ischemic stroke, emergency conversion to cardiac surgery, and permanent pacemaker implantation. Echocardiography was used to analyze the left ventricular function before the TAVR procedure and during follow-up. Multivariable logistic regression and Cox regression analyses were performed to find relevant independent risk factors.Results::Between September 2019 and February 2022, 79 patients with AR were enrolled in the study. At 1 month, device success was achieved in 60 (75.9%) patients. By 6 months, 29 (36.7%) patients had MACE. Echocardiography revealed improved left ventricular function after TAVR. Multivariate regression analysis demonstrated that the Society of Thoracic Surgeons risk score (odds ratio 0.760, 95% confidence interval (CI): 0.584-0.989; P = 0.041) and annulus perimeter (odds ratio 0.888, 95% CI: 0.796-0.992; P = 0.035) were 2 predictors of device success. Moreover, annulus perimeter (<80.2 mm), but not Society of Thoracic Surgeons risk score, was associated with a significant reduction in MACE at 6 months (hazard ratio 2.223, 95% CI: 1.060-4.659; P = 0.028). Conclusions::TF-TAVR using a self-expanding valve system appears to be a safe and feasible treatment for patients with pure native severe AR, particularly those with a less enlarged annulus.
8.Concomitant extragenital malformations of female reproductive tract anomalies: analysis of 444 cases in Peking Union Medical College Hospital
Si SU ; Xinmiao BAO ; Shu WANG ; Na CHEN ; Zhufeng LIU ; Dawei SUN ; Jinhua LENG ; Qingbo FAN ; Honghui SHI ; Zhijing SUN ; Juan CHEN ; Haiyuan LIU ; Xin YU ; Junji ZHANG ; Yi DAI ; Jinghe LANG ; Lan ZHU
Chinese Journal of Obstetrics and Gynecology 2024;59(5):346-352
Objective:To analyze the incidence and clinical phenotype of the concomitant extragenital malformations in the patients with female reproductive tract anomalies.Methods:A retrospective study was conducted using clinical data of hospitalized patients diagnosed with uterine, cervical, or vaginal malformations from January 2003 to December 2022 in Peking Union Medical College Hospital. The malformations were classified according to American Society for Reproductive Medicine müllerian anomalies classification 2021, and in each type, the incidence and specific manifestations of concomitant extragnital malformations were analyzed.Results:A total of 444 patients were included. The overall incidence of concomitant extragenital malformations was 43.5% (193/444), including urinary system, skeletal system, and other system malformations. Renal malformations on the obstructed side were present in all patients with oblique vaginal septum syndrome (100.0%, 78/78). The total incidence of concomitant extragnital malformations was as high as 8/11 in uterus didelphys, 43.5% (10/23) in unicornuate uterus, 33.6% (79/235) in Mayer-Rokitansky-Küster-Hauser syndrome, 18.8% (6/32) in septate uterus and 18.5% (12/65) in cervical agenesis. Urinary system malformations (30.6%, 136/444) and skeletal system malformations (13.5%, 60/444) were the most common concomitant malformations in all types, in which, unilateral renal agenesis and scoliosis were the most common.Conclusions:Urinary and skeletal system malformations are important features of female reproductive tract anomalies. Urologic ultrasonography and spinal roentgenogram are recommended for all patients with female reproductive tract anomalies.
9.Development of a Usability Scale for Smart Hospital Platforms Based on QoE Theory
Peipei JIA ; Xiaowei WANG ; Meihua LI ; Lianfang LU ; Juan FENG ; Hanxu LANG ; Lili WEI
Chinese Hospital Management 2024;44(11):70-73
Objective To construct a usability scale for smart hospital platforms based on Quality of Experience(QoE)theory,and provide scientific measurement tool for the construction,operation,and improvement of smart hospitals.Method Literature review,focus meeting method,and pre survey were used to screen and revise the scale items,forming a formal scale.Using convenience sampling method,1 000 users from 8 smart hospital platforms in Shandong Province were selected as the research subjects to evaluate the reliability and validity of the scale.Result The availability scale of the smart hospital platform includes 6 dimensions and 24 items.Exploratory factor extraction identified 6 common factors,with a cumulative variance contribution rate of 64.045%.The overall Cronbach's with a coefficient of 0.941 for 6 dimensions.The coefficient is between 0.782 and 0.963,and the retest reliability is 0.967.The Average Standardized Content Validity Index is 0.972,and the Item-level Content Validity Index is between 0.86 and 1.00.The correlation coefficient between the six dimensions of the scale and the System Usability Scale is 0.606-0.653,and the overall correlation coefficient is 0.647.Conclusion The usability scale of the smart hospital platform developed based on QoE theory has good reliability and validity,and can be used to measure the user experience of the smart hospital platform.
10.Development of a Usability Scale for Smart Hospital Platforms Based on QoE Theory
Peipei JIA ; Xiaowei WANG ; Meihua LI ; Lianfang LU ; Juan FENG ; Hanxu LANG ; Lili WEI
Chinese Hospital Management 2024;44(11):70-73
Objective To construct a usability scale for smart hospital platforms based on Quality of Experience(QoE)theory,and provide scientific measurement tool for the construction,operation,and improvement of smart hospitals.Method Literature review,focus meeting method,and pre survey were used to screen and revise the scale items,forming a formal scale.Using convenience sampling method,1 000 users from 8 smart hospital platforms in Shandong Province were selected as the research subjects to evaluate the reliability and validity of the scale.Result The availability scale of the smart hospital platform includes 6 dimensions and 24 items.Exploratory factor extraction identified 6 common factors,with a cumulative variance contribution rate of 64.045%.The overall Cronbach's with a coefficient of 0.941 for 6 dimensions.The coefficient is between 0.782 and 0.963,and the retest reliability is 0.967.The Average Standardized Content Validity Index is 0.972,and the Item-level Content Validity Index is between 0.86 and 1.00.The correlation coefficient between the six dimensions of the scale and the System Usability Scale is 0.606-0.653,and the overall correlation coefficient is 0.647.Conclusion The usability scale of the smart hospital platform developed based on QoE theory has good reliability and validity,and can be used to measure the user experience of the smart hospital platform.

Result Analysis
Print
Save
E-mail