1.Research progress of the diagnosis and treatment of anterior shoulder instability.
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(5):509-517
The shoulder joint is the most prone to dislocation in the whole body, and more than 95% of them are anterior dislocation. Improper treatment after the initial dislocation is easy to lead to recurrent anterior dislocation or anterior shoulder instability, and the outcomes following conservative treatment is poor. Anterior shoulder instability can damage the soft tissue structure and bone structure that maintain the stability of shoulder joint, among which bone structure is the most important factor affecting the stability of shoulder joint. Diagnosis should be combined with medical history, physical examination, and auxiliary examination. Currently, three-dimensional CT is the most commonly used auxiliary examination means. However, various bone defect measurement and preoperative evaluation methods based on three-dimensional CT and the glenoid track theory have their own advantages and disadvantages, and there is still a lack of gold standard. Currently, the mainstream treatment methods mainly include Bankart procedure, coracoid process transposition, glenoid reconstruction with free bone graft, Bankart combined with Remplissage procedure, and subscapular tendon binding tamponade, etc. Each of these procedures has its own advantages and disadvantages. For the diagnosis and treatment of anterior shoulder instability, there are still too many unknown, further research and exploration need to be studied.
Humans
;
Shoulder Joint/surgery*
;
Shoulder Dislocation/surgery*
;
Shoulder
;
Joint Instability/surgery*
;
Scapula
;
Joint Dislocations
;
Recurrence
;
Arthroscopy/methods*
2.Posterior cervical pedicle screw rod short-segment internal fixation for the treatment of atlantoaxial fracture and dislocation.
Hong-Xing ZHANG ; Yan ZHU ; Xiang-Qin SHI
China Journal of Orthopaedics and Traumatology 2023;36(5):490-494
OBJECTIVE:
To investigate the clinical efficacy of posterior cervical pedicle screw short-segment internal fixation for the treatment of atlantoaxial fracture and dislocation.
METHODS:
The clinical data of 60 patients with atlantoaxial vertebral fracture and dislocation underwent surgery between January 2015 and January 2018 were retrospectively analyzed. The patients were divided into study group and control group according to different surgical methods. There were 30 patients in study group, including 13 males and 17 females, with an average age of (39.32±2.85) years old, were underwent short-segment internal fixation with posterior cervical pedicle screws. There were 30 patients in control group, including 12 males and 18 females, with an average age of (39.57±2.90) years old, were underwent posterior lamina clip internal fixation of the atlas. The operation time, intraoperative blood loss, postoperative ambulation time, hospitalization time and complications between two groups were recorded and compared. The pain visual analogue scale(VAS), Japanese Orthopedic Association(JOA) score of neurological function, and fusion status were evaluated between two groups.
RESULTS:
All patients were followed up for at least 12 months. The study group was better than control group in operation time, intraoperative blood loss, postoperative off-bed activity time, and hospital stay (P=0.000). One case of respiratory tract injury occurred in study group. In control group, 2 cases occurred incision infection, 3 cases occurred respiratory tract injury, and 3 cases occurred adjacent segmental joint degeneration. The incidence of complications in study group was lower than that in control group (χ2=4.705, P=0.030). At 1, 3, 7 days after operation, VAS of study group was lower than that of control group(P=0.000). At 1, 3 months after operation, JOA score of study group was higher than that of control group(P=0.000). At 12 months after operation, all the patients in the study group achieved bony fusion. In control group, there were 3 cases of poor bony fusion and 3 cases of internal fixation fracture, the incidence rate was 20.00%(6/30). The difference between two groups was statistically significant (χ2=4.629, P=0.031).
CONCLUSION
Posterior cervical short-segment pedicle screw fixation for atlantoaxial fracture and dislocation has the advantages of less trauma, shorter operation time, fewer complications, and less pain, and can promote the recovery of nerve function as soon as possible.
Male
;
Female
;
Humans
;
Adult
;
Pedicle Screws
;
Retrospective Studies
;
Fractures, Bone
;
Fracture Fixation, Internal/methods*
;
Joint Dislocations/surgery*
;
Spinal Fractures/surgery*
;
Treatment Outcome
;
Postoperative Hemorrhage
3.Finite element analysis of different reconstruction methods of coracoclavicular ligament for acromioclavicular joint dislocation.
Hao CHEN ; Jia-Hu FANG ; Guo-Yong YIN
China Journal of Orthopaedics and Traumatology 2023;36(6):543-549
OBJECTIVE:
This study aims to examine the biomechanical effects of different reconstruction methods, including single-bundle, double-bundle anatomical reconstruction, and double-bundle truly anatomical reconstruction of the coracoclavicular ligament on the acromioclavicular joint using finite element analysis, to provide a theoretical basis for the clinical application of truly anatomical coracoclavicular ligament reconstruction.
METHODS:
One volunteer, aged 27 years old, with a height of 178 cm and a weight of 75 kg, was selected for CT scanning of the shoulder joint. Three-dimensional finite element models of single-bundle reconstruction, double-bundle anatomical reconstruction, and double-bundle truly anatomical reconstruction of coracoclavicular ligament were established by using Mimics17.0, Geomagic studio 2012, UG NX 10.0, HyperMesh 14.0 and ABAQUS 6.14 software. The maximum displacement of the middle point of the distal clavicle in the main loading direction and the maximum equivalent stress of the reconstruction device under different loading conditions were recorded and compared.
RESULTS:
The maximum forward displacement and the maximum backward displacement of the middle point of the distal clavicle in the double-bundle truly anatomic reconstruction were the lowest, which were 7.76 mm and 7.27 mm respectively. When an upward load was applied, the maximum displacement of the distal clavicle midpoint in the double-beam anatomic reconstruction was the lowest, which was 5.12 mm. Applying three different loads forward, backward, and upward, the maximum equivalent stress of the reconstruction devices in the double-beam reconstruction was lower than that in the single-beam reconstruction. The maximum equivalent stress of the trapezoid ligament reconstruction device in the double-bundle truly anatomical reconstruction was lower than that in the double-bundle anatomical reconstruction, which was 73.29 MPa, but the maximum equivalent stress of the conoid ligament reconstruction device was higher than that of the double-bundle anatomical reconstruction.
CONCLUSION
The truly anatomical reconstruction of coracoclavicular ligament can improve the horizontal stability of acromioclavicular joint and reduce the stress of the trapezoid ligament reconstruction device. It can be a good method for the treatment of acromioclavicular joint dislocation.
Humans
;
Adult
;
Acromioclavicular Joint/surgery*
;
Finite Element Analysis
;
Ligaments, Articular/surgery*
;
Shoulder Joint/surgery*
;
Plastic Surgery Procedures
;
Joint Dislocations/surgery*
5.Evaluation of the relationship between the attachment type of lateral pterygoid muscle and the position of temporomandibular joint disc in patients with temporomandibular joint disorders based on wireless amplified MRI detector high resolution imaging.
Xin Ge CHENG ; Chong TIAN ; Rong HU ; Jian LIU ; Min XU ; Yu WU ; Rong Pin WANG ; Xian Chun ZENG
Chinese Journal of Stomatology 2023;58(6):569-574
Objective: To explore the correlation between the attachment type of lateral pterygoid muscle (LPM) and the position of temporomandibular joint (TMJ) disc in patients with temporomandibular disorders (TMD) by using wireless amplified magnetic resonance imaging detector (WAND) coupled with conventional head and neck joint coil for high resolution imaging of TMJ. Methods: Eighty-five patients with TMD diagnosed by oral and maxillofacial surgeons of Guizhou Provincial People's Hospital from October 2019 to January 2022 were collected. A total of 160 TMJ were included. There were 16 males and 69 females, aged (32.7±14.2) years. All patients were scanned with open, closed oblique sagittal and coronal WAND coupled head and neck coils with bilateral TMJ. Based on TMJ and LPM high resolution imaging, to explore the correlation between LPM attachment types and the position of TMJ disc in TMD patients, and to evaluate the potential clinical value of LPM attachment types in TMD patients. χ2 test and Pearson correlation analysis were used to evaluate the correlation between LPM attachment type and TMJ disc location. Results: There were three types of LPM attachment: type Ⅰ in 51 cases [31.9% (51/160)], type Ⅱ in 77 cases [48.1% (77/160)] and type Ⅲ in 32 cases [20.0% (32/160)]. There was a significant correlation between the type of LPM attachment and the position of articular disc (χ2=28.20, P=0.002, r=0.776). There was no statistical significance between the type of LPM attachment and the reversible displacement of articular disc (χ2=0.24, P=0.887, r=0.825). Conclusions: There is a correlation between the attachment type of LPM and the position of the disc in TMD patients. WNAD coupled with conventional head and neck joint coil TMJ high resolution scan can provide reliable imaging evidence for TMD patients in evaluating the type of LPM attachment and the location of disc.
Male
;
Female
;
Humans
;
Temporomandibular Joint Disc/pathology*
;
Pterygoid Muscles/pathology*
;
Joint Dislocations
;
Temporomandibular Joint Disorders/diagnostic imaging*
;
Magnetic Resonance Imaging/methods*
;
Temporomandibular Joint/pathology*
6.Manual reduction of severe cervical fracture and dislocation combined with anterior and posterior surgery under general anesthesia:a case report and literature review.
Yue-Peng SONG ; Xin-Ge SHI ; Wei-Ran HU ; Hao-Hao MA ; Shuai XING ; Xiao-Nan WU
China Journal of Orthopaedics and Traumatology 2023;36(1):64-67
8.Application of modified articular disc anchorage in treating the perforation and rupture of temporomandibular joint disc.
Tiebiao WANG ; Wuchao ZHOU ; Yin XIAO ; Jialong CHENG ; Zhoucheng OUYANG ; Chen CHENG ; Weihong XI
West China Journal of Stomatology 2023;41(4):434-442
OBJECTIVES:
This study aimed to use modified articular disc anchorage in treating old irreducible temporomandibular joint (TMJ) disc displacement with perforation and rupture, as well as to explore its efficacy.
METHODS:
A total of 31 patients (34 sides) with 47 TMJ disc perforations who underwent surgical treatment in the Affiliated Stomatolo-gical Hospital of Nanchang University from January 2018 to December 2021 were selected. According to the location of disc perforation, it has five types: posterior disc perforation (typeⅠ), anterior disc perforation (typeⅡ), lateral disc perforation (type Ⅲ), composite disc perforation, and destruction disc perforation. The modified methods of disc anchoring were divided into two types according to the location of the perforation. TypesⅠandⅢ disc perforation were trea-ted by posterior anchoring method. For posterior ancho-ring, a screw was implanted into the posterolateral side of the condylar neck, and the disc was fixed on the screw by horizontal mattress suture. TypeⅡdisc perforation and compo-site disc perforation combined typeⅡperforation were treated by anterior and posterior double-anchoring method. For anterior anchoring, anchor screws or holes were placed at the anterior edge of the condylar neck, and horizontal mattress suture was performed at the posterior edge of the anterior perforation with an anchor wire. The articular disc was then fixed on the anchor screws or holes. For the posterior anchoring method, it was the same as the previous one. Paired t test was used to analyze the visual analog scale (VAS), maximum interincisal opening (MIO), and TMJ disorder index (CMI) of the patient before surgery and 1, 3, and 6 months after surgery. Disk-condyle position relationship by magnetic resonance imaging and postoperative quality of life in postoperative were analyzed.
RESULTS:
The incidence of perforation was 41.2% (14/34) in typeⅠ, 11.8% (4/34) in typeⅡ, 8.8% (3/34) in typeⅢ, 29.4% (10/34) in composite type, and 8.8% (3/34) in destruction type. The VAS, MIO, and CMI at 3, 6 months after operation significantly improved compared with those before operation (P<0.05). The effective reduction rate of disc was 96.77% (30/31). The quality of life at 6 months after surgery was 47.22±2.13, and the rate of excellent evaluation was 96.4% (27/28).
CONCLUSIONS
Modified articular disc anchorage achieves a good curative effect for treating temporomandibular joint disc perforation and rupture. Nevertheless, its long-term effect requires further observation.
Humans
;
Temporomandibular Joint Disc/surgery*
;
Quality of Life
;
Joint Dislocations/surgery*
;
Temporomandibular Joint Disorders/surgery*
;
Magnetic Resonance Imaging/methods*
;
Temporomandibular Joint/pathology*
;
Mandibular Condyle
9.A study of the correlation between glenohumeral joint congruence and stability in recurrent shoulder dislocations.
Zheng XU ; Fei DAI ; Jinsong YANG ; Qing ZHANG ; Ming XIANG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(9):1094-1097
OBJECTIVE:
To investigate the correlation between glenohumeral joint congruence and stability in recurrent shoulder dislocations.
METHODS:
Eighty-nine patients (89 sides) with recurrent shoulder dislocation admitted between June 2022 and June 2023 and met the selection criteria were included as study subjects. There were 36 males and 53 females with an average age of 44 years (range, 20-79 years). There were 40 cases of left shoulder and 49 cases of right shoulder. The shoulder joints dislocated 2-6 times, with an average of 3 times. The three-dimensional models of the humeral head and scapular glenoid were reconstructed using Mimics 20.0 software based on CT scanning images. The glenoid track (GT), inclusion index, chimerism index, fit index, and Hill-Sachs interval (HSI) were measured, and the degree of on/off track was judged (K value, the difference between HSI and GT). Multiple linear regression was used to analyze the correlation between the degree of on/off track (K value) and inclusion index, chimerism index, and fit index.
RESULTS:
Multiple linear regression analysis showed that the K value had no correlation with the inclusion index ( P>0.05), and was positively correlated with the chimerism index and the fit index ( P<0.05). Regression equation was K=-24.898+35.982×inclusion index+8.280×fit index, R 2=0.084.
CONCLUSION
Humeral head and scapular glenoid bony area and curvature are associated with shoulder joint stability in recurrent shoulder dislocations. Increased humeral head bony area, decreased scapular glenoid bony area, increased humeral head curvature, and decreased scapular glenoid curvature are risk factors for glenohumeral joint stability.
Female
;
Male
;
Humans
;
Adult
;
Shoulder Joint/diagnostic imaging*
;
Shoulder Dislocation/diagnostic imaging*
;
Joint Dislocations
;
Scapula/diagnostic imaging*
;
Thorax
10.Advances in peripatellar osteotomy for treating recurrent patellar dislocation.
Jiahui CHEN ; Jianxiong MA ; Xinlong MA
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(9):1156-1161
OBJECTIVE:
To summarize the progress of research related to the surgical treatment of recurrent patellar dislocation by peripatellar osteotomy in clinical practice, in order to provide reference for clinical treatment.
METHODS:
The recent literature on peripatellar osteotomy for recurrent patellar dislocation at home and abroad was reviewed, and the bony structural abnormalities, imaging diagnosis, and treatment status were summarized.
RESULTS:
Abnormalities in the bony anatomy of the lower limb and poor alignment lead to patellofemoral joint instability through the quadriceps pulling force line and play an important role in the pathogenesis of recurrent patellar dislocation. Identifying the source of the deformity and intervening with peripatellar osteotomy to restore the biomechanical structure of the patellofemoral joint can reduce the risk of soft tissue surgical failure, delay joint degeneration, and achieve the target of treatment.
CONCLUSION
In the clinical diagnosis and treatment of recurrent patellar dislocation, the factors causing patellofemoral joint instability should be comprehensively evaluated to guide the selection of surgery and personalized treatment.
Humans
;
Patellar Dislocation/surgery*
;
Joint Dislocations
;
Joint Instability/surgery*
;
Lower Extremity
;
Osteotomy

Result Analysis
Print
Save
E-mail