1.Evaluation of Right Ventricular Function in Cardiac Amyloidosis by Two-Dimensional Speckle Tracking Imaging
Huiying CHEN ; Xiaojing MA ; Juan XIA ; Yafeng HE ; Jingjing WANG ; Jinlong ZHONG
Chinese Journal of Medical Imaging 2025;33(6):638-644
Purpose To investigate the value of two-dimensional speckle tracking in evaluating right ventricular function in cardiac amyloidosis(CA).Materials and Methods A total of 25 patients with CA,30 patients with hypertrophic cardiomyopathy(HCM)and 30 healthy controls were retrospectively selected from July 2021 to October 2023 in Wuhan Asia Heart Hospital.The regional difference was represented by the formula apical ratio.The parameters of conventional echocardiography,two-dimensional strain and apical ratio of the three groups were analyzed and compared.Results Only segmental strain was different in right ventricular structure and function between CA group and HCM group,and the differences were statistically significant(all P<0.05).In the CA group,the strain gradient of the right ventricle from the apex of the heart to the base was the same as that of the left ventricle,that was,the"apex preservation"pattern,which was not seen in the HCM group and the control group.Comparison of the right ventricular free wall longitudinal strain-apical ratio,right ventricle four-chamber longitudinal strain-apical ratio,left ventride global longitudinal strain-apical ratio among the three groups,it was found that the levels of CA group were higher than HCM group and control group,and the differences were statistically significant(H=40.40,43.18,55.43,all P<0.05).The right ventricular free wall longitudinal strain-apical ratio had the highest CA recognition value,the area under the curve was 0.935,sensitivity was 96%and specificity was 83%.Conclusion Two-dimensional speckle tracking can accurately evaluate the right ventricular function impairment in CA patients and provide a new choice for clinical evaluation and identification of CA patients.
2.Quantitative Evaluation of Mitral Valve Structure and Function in Mitral Valve Prolapse by Three-Dimensional Transesophageal Echocardiography
Jinlong ZHONG ; Juan XIA ; Xiaojing MA ; Huiying CHEN
Chinese Journal of Medical Imaging 2025;33(8):854-861
Purpose To evaluate the static structural changes of mitral annulus and leaflets in mitral valve prolapse via three-dimensional transesophageal echocardiography(3D-TEE),and their continuous dynamic changes during the cardiac cycle.Materials and Methods Twenty-six patients with mitral valve prolapse diagnosed by transesophageal echocardiography in Wuhan Asia Heart Hospital from June 2022 to June 2023 were retrospectively included,and 30 patients who were examined by transesophageal echocardiography in our hospital during the same period due to monitoring of patent foramen ovale or non-cardiac surgery were selected as the control group.The related parameters of the valve annulus were measured.In addition,the meaningful parameters were measured at late diastole(LD),early systole(ES),middle systole(MS)and late systole(LS),and the change rate was calculated.The static structure of mitral valve device was compared between the two groups,and the differences of various parameters at different times were analyzed.Results Compared with the control group,the annulus height(AH)and the ratio of annulus height and combined width(AHCWR)in the case group decreased,and the other parameters increased(t=-7.447-12.472,all P<0.05),but there was no statistical difference in the maximum displacement distance of the annulus between the two groups(P>0.05).Comparing the related parameters of LD,ES,MS and LS at four different time points,compared with the control group,all the parameters in the case group increased except AH and AHCWR(t=-16.224-15.683,all P<0.05).Comparing the continuous changes at four different times,the continuous changes of all parameters in the control group were statistically significant(F=7.632-323.837,all P<0.05),and there were significant differences in the parameters of the control group from LD to ES(all P<0.05).Except anterolateral to posteromedial diameter,intertrigonal diameter and annulus area,the continuous changes of other parameters in the case group were statistically significant(F=3.041-71.082,all P<0.05),and only non-planar angle,AH and AHCWR in the case group had statistical differences in LD to ES(all P<0.05).Compared with the control group,the change rate of parameters in the case group decreased,and the difference was statistically significant(t/U=-7.069-780.000,all P<0.05),and the change rate of C-ring was greater than that of intertrigonal diameter.Conclusion 3D-TEE can quantitatively analyze the dynamic changes of mitral annulus and leaflets,and analyze the continuous changes of mitral valve in cardiac cycle in detail,which can provide more accurate preoperative evaluation for patients and guide treatment.
3.Effect of the thicknesses of different reconstruction layer and the ROI thicknesses on the measurement of BMD value of QCT
Jinlong LIU ; Danyang SU ; Haoran ZHANG ; Yuanbo MA ; Qiuju MIAO ; Zhen BAI ; Xiaopeng YANG
China Medical Equipment 2025;22(1):19-23
Objective:To assess the effect of using different thicknesses of reconstruction layer and different thicknesses of region of interest (ROI) on the results of vertebral bone mineral density (BMD) values that were measured by quantitative computed tomography (QCT). Methods:A total of 100 patients who underwent QCT screening for opportunistic osteoporosis between May and September 2021 at the First Affiliated Hospital of Zhengzhou University were retrospectively collected. Images that the thicknesses of QCT reconstruction layer were respectively 1 and 5 mm were transferred to the QCT Pro workstation,and ROI thicknesses were adjusted to 5,7,and 9 mm,respectively. The average BMD values of QCT measurements were recorded under different thicknesses of reconstruction layer and different ROI thicknesses. Then,the effects of the choose of different thicknesses of reconstruction layer and the different ROI thicknesses on BMD values that were measured by QCT were analyzed. Results:The average BMD values of 1 mm and 5 mm thicknesses of reconstruction layer were respectively (117.41±45.97) mg/cm3 and (118.77±44.84) mg/cm3 when ROI thickness was 5 mm,with a statistically significant difference (t=-2.283,P<0.05). The average BMD values of 1 mm and 5 mm thicknesses of reconstruction layer were respectively (116.38±46.06) mg/cm3 and (119.06±44.55) mg/cm3 when the ROI thickness was 7mm,and the difference was statistically significant (t=-3.280,P<0.05). The average BMD values of 1 mm and 5 mm thicknesses of reconstruction layer were respectively (116.25±45.36) mg/cm3 and (120.12±44.10) mg/cm3 when the ROI thickness was 9 mm,and the difference was statistically significant (t=-5.841,P<0.001). The differences in BMD measurement values among 5,7 and 9 mm ROI thicknesses were not statistically significant when the thicknesses of reconstruction layer were respectively 1 and 5 mm. Conclusion:There is an effect of the thickness of QCT reconstruction layer on average BMD measurement values,and 1 mm thickness of reconstruction layer is more suitable to clinical application,while there is not significant effect in ROI thickness on average BMD measurement value of QCT. In clinical application,it is feasible to adjust ROI thickness according to actual situation so as to avoid the effect caused by some factors such as fracture or vertebral implants.
4.Establishment and application of key technologies for periodontal tissue regeneration based on microenvironment and stem cell regulation
Baojin MA ; Jianhua LI ; Yuanhua SANG ; Yang YU ; Jichuan QIU ; Jinlong SHAO ; Kai LI ; Shiyue LIU ; Mi DU ; Lingling SHANG ; Shaohua GE
Journal of Peking University(Health Sciences) 2025;57(5):841-846
The prevalence of periodontitis in China is as high as 74.2%,making it the leading cause of tooth loss in adults and severely impacting both oral and overall health.The treatment of periodontitis and periodontal tissue regeneration are global challenges of significant concern.GE Shaohua's group at School and Hospital of Stomatology,Shandong University has focused on the key scientific issue of"re-modeling the periodontal inflammatory microenvironment and optimizing tissue repair and regeneration".They have elucidated the mechanisms underlying the persistence of periodontitis,developed bioactive ma-terials to enhance stem cell regenerative properties,and constructed a series of guided tissue regeneration barrier membranes to promote periodontal tissue repair,leading to the establishment of a comprehensive technology system for the treatment of periodontitis.Specific achievements and progress include:(1)Elucidating the mechanism by which key periodontal pathogens evade antimicrobial autophagy,leading to inflammatory damage;developing intelligent antimicrobial hydrogels and nanosystems,and creating metal-polyphenol network microsphere capsules to reshape the periodontal inflammatory microenviron-ment;(2)Explaining the mechanisms by which nanomaterial structures and electroactive interfaces regu-late stem cell behavior,developing optimized nanostructures and electroactive biomaterials,thereby effec-tively enhancing the regenerative repair capabilities of stem cells;(3)Creating a series of biphasic heterogeneous barrier membranes,refining guided tissue regeneration and in situ tissue engineering techniques,stimulating the body's intrinsic repair potential,and synergistically promoting the structural regeneration and functional reconstruction of periodontal tissues.The research outcomes of the group have innovated the fundamental theories of periodontal tissue regeneration,broken through foreign technologi-cal barriers and patent blockades,established a cascade repair strategy for periodontal regeneration,and enhanced China's core competitiveness in the field of periodontal tissue regeneration.
5.Effect of the thicknesses of different reconstruction layer and the ROI thicknesses on the measurement of BMD value of QCT
Jinlong LIU ; Danyang SU ; Haoran ZHANG ; Yuanbo MA ; Qiuju MIAO ; Zhen BAI ; Xiaopeng YANG
China Medical Equipment 2025;22(1):19-23
Objective:To assess the effect of using different thicknesses of reconstruction layer and different thicknesses of region of interest (ROI) on the results of vertebral bone mineral density (BMD) values that were measured by quantitative computed tomography (QCT). Methods:A total of 100 patients who underwent QCT screening for opportunistic osteoporosis between May and September 2021 at the First Affiliated Hospital of Zhengzhou University were retrospectively collected. Images that the thicknesses of QCT reconstruction layer were respectively 1 and 5 mm were transferred to the QCT Pro workstation,and ROI thicknesses were adjusted to 5,7,and 9 mm,respectively. The average BMD values of QCT measurements were recorded under different thicknesses of reconstruction layer and different ROI thicknesses. Then,the effects of the choose of different thicknesses of reconstruction layer and the different ROI thicknesses on BMD values that were measured by QCT were analyzed. Results:The average BMD values of 1 mm and 5 mm thicknesses of reconstruction layer were respectively (117.41±45.97) mg/cm3 and (118.77±44.84) mg/cm3 when ROI thickness was 5 mm,with a statistically significant difference (t=-2.283,P<0.05). The average BMD values of 1 mm and 5 mm thicknesses of reconstruction layer were respectively (116.38±46.06) mg/cm3 and (119.06±44.55) mg/cm3 when the ROI thickness was 7mm,and the difference was statistically significant (t=-3.280,P<0.05). The average BMD values of 1 mm and 5 mm thicknesses of reconstruction layer were respectively (116.25±45.36) mg/cm3 and (120.12±44.10) mg/cm3 when the ROI thickness was 9 mm,and the difference was statistically significant (t=-5.841,P<0.001). The differences in BMD measurement values among 5,7 and 9 mm ROI thicknesses were not statistically significant when the thicknesses of reconstruction layer were respectively 1 and 5 mm. Conclusion:There is an effect of the thickness of QCT reconstruction layer on average BMD measurement values,and 1 mm thickness of reconstruction layer is more suitable to clinical application,while there is not significant effect in ROI thickness on average BMD measurement value of QCT. In clinical application,it is feasible to adjust ROI thickness according to actual situation so as to avoid the effect caused by some factors such as fracture or vertebral implants.
6.Application of mind mapping for teaching anatomy of laboratory animals
Sheng YANG ; Zhiyu MA ; Qi LIU ; Jinlong ZHANG ; Zhiqiang WANG ; Fenglei CHEN
Chinese Journal of Comparative Medicine 2025;35(6):99-103
Anatomy of laboratory animals plays an important role in laboratory animal science,veterinary medicine,and other life sciences.Integrating mind mapping into the entire teaching process can effectively help teachers to optimize the organization of teaching contents and stimulate students' enthusiasm and self-motivation for learning.This manuscript aims to explore the feasibility,advantages,and challenges of applying mind-mapping tools for teaching anatomy of laboratory animals.We analyze the different application scenarios from the perspectives of both teachers and students,with the aim of providing practical teaching tools and methodologies to enhance instructional effectiveness in the teaching of anatomy of laboratory animals.
7.Quantitative Evaluation of Mitral Valve Structure and Function in Mitral Valve Prolapse by Three-Dimensional Transesophageal Echocardiography
Jinlong ZHONG ; Juan XIA ; Xiaojing MA ; Huiying CHEN
Chinese Journal of Medical Imaging 2025;33(8):854-861
Purpose To evaluate the static structural changes of mitral annulus and leaflets in mitral valve prolapse via three-dimensional transesophageal echocardiography(3D-TEE),and their continuous dynamic changes during the cardiac cycle.Materials and Methods Twenty-six patients with mitral valve prolapse diagnosed by transesophageal echocardiography in Wuhan Asia Heart Hospital from June 2022 to June 2023 were retrospectively included,and 30 patients who were examined by transesophageal echocardiography in our hospital during the same period due to monitoring of patent foramen ovale or non-cardiac surgery were selected as the control group.The related parameters of the valve annulus were measured.In addition,the meaningful parameters were measured at late diastole(LD),early systole(ES),middle systole(MS)and late systole(LS),and the change rate was calculated.The static structure of mitral valve device was compared between the two groups,and the differences of various parameters at different times were analyzed.Results Compared with the control group,the annulus height(AH)and the ratio of annulus height and combined width(AHCWR)in the case group decreased,and the other parameters increased(t=-7.447-12.472,all P<0.05),but there was no statistical difference in the maximum displacement distance of the annulus between the two groups(P>0.05).Comparing the related parameters of LD,ES,MS and LS at four different time points,compared with the control group,all the parameters in the case group increased except AH and AHCWR(t=-16.224-15.683,all P<0.05).Comparing the continuous changes at four different times,the continuous changes of all parameters in the control group were statistically significant(F=7.632-323.837,all P<0.05),and there were significant differences in the parameters of the control group from LD to ES(all P<0.05).Except anterolateral to posteromedial diameter,intertrigonal diameter and annulus area,the continuous changes of other parameters in the case group were statistically significant(F=3.041-71.082,all P<0.05),and only non-planar angle,AH and AHCWR in the case group had statistical differences in LD to ES(all P<0.05).Compared with the control group,the change rate of parameters in the case group decreased,and the difference was statistically significant(t/U=-7.069-780.000,all P<0.05),and the change rate of C-ring was greater than that of intertrigonal diameter.Conclusion 3D-TEE can quantitatively analyze the dynamic changes of mitral annulus and leaflets,and analyze the continuous changes of mitral valve in cardiac cycle in detail,which can provide more accurate preoperative evaluation for patients and guide treatment.
8.Application of dual-energy computed tomography imaging for evaluation of bone repair
Danyang SU ; Yuanbo MA ; Jinlong LIU ; Haoran ZHANG ; Shenyu YANG ; Qiuju MIAO ; Zhen BAI ; Xiaopeng YANG
Chinese Journal of Comparative Medicine 2025;35(1):155-162
Bone defect repair is an urgent problem in the field of orthopedics,and numerous researchers are working to develop more effective treatment plans.The accurate evaluation of bone repair after surgery is a crucial step.In line with the development of computed tomography(CT)imaging,dual-energy CT imaging has shown significant advantages in analyzing bone composition and reducing metal artifacts.This article reviews the application of dual-energy CT imaging for the evaluation of bone repair in animals.
9.Characteristics and prevention and control strategies of combat trauma related infections:an open-source literature databases
Guoxing HUANG ; Jingyuan MA ; Hongwu YAO ; Jinlong WANG ; Di WU ; Meng WANG ; Xinlou LI
Chinese Journal of Nosocomiology 2025;35(16):2529-2534
OBJECTIVE By conducting evidence evaluation research on literatures,this study aims to reveal the o-verall characteristics and research hotspots in the field of combat trauma-related infections,ultimately providing data support for the prevention and control of such infections.METHODS Relevant research in this field was sys-tematically collected from open-source databases to construct a dataset.The overall characteristics,research hotspots,prevention and control strategies,and future challenges of trauma-related infections were summarized and analyzed.RESULTS From 2004 to 2024,184 papers were published.The United States contributed the most publications,with Uniformed Services University of the Health Sciences being the most productive research insti-tution and Professor Clinton K.Murray as the author with the highest number of publications.The top five key-words with the highest frequency were combat related injury,infection,Acinetobacter baumannii,epidemiology and management.Among the publicly published literature data on war trauma-related infections,blast injuries ac-counted for the largest proportion,mainly multi-site injuries,with limb injuries being the most common.Bacteri-al infections were more common than fungal infections,with gram-negative bacteria being predominant and A.baumannii being the most common.Besides early wound management and the use of antibacterial drugs,in-creased attention should be paid to infection prevention and control in austere environments and the development of novel countermeasures.These advancements are critical to address projected changes in combat trauma,inclu-ding increasingly complex injuries and substantially elevated risks of infection and antimicrobial resistance.CONCLUSION This study systematically presents research hotspots,developmental trends,and prospects in com-bat trauma-related infections through evidence evaluation study,providing novel perspectives for researchers and facilitating further development in this field.
10.Expert consensus on the diagnosis and treatment of cemental tear.
Ye LIANG ; Hongrui LIU ; Chengjia XIE ; Yang YU ; Jinlong SHAO ; Chunxu LV ; Wenyan KANG ; Fuhua YAN ; Yaping PAN ; Faming CHEN ; Yan XU ; Zuomin WANG ; Yao SUN ; Ang LI ; Lili CHEN ; Qingxian LUAN ; Chuanjiang ZHAO ; Zhengguo CAO ; Yi LIU ; Jiang SUN ; Zhongchen SONG ; Lei ZHAO ; Li LIN ; Peihui DING ; Weilian SUN ; Jun WANG ; Jiang LIN ; Guangxun ZHU ; Qi ZHANG ; Lijun LUO ; Jiayin DENG ; Yihuai PAN ; Jin ZHAO ; Aimei SONG ; Hongmei GUO ; Jin ZHANG ; Pingping CUI ; Song GE ; Rui ZHANG ; Xiuyun REN ; Shengbin HUANG ; Xi WEI ; Lihong QIU ; Jing DENG ; Keqing PAN ; Dandan MA ; Hongyu ZHAO ; Dong CHEN ; Liangjun ZHONG ; Gang DING ; Wu CHEN ; Quanchen XU ; Xiaoyu SUN ; Lingqian DU ; Ling LI ; Yijia WANG ; Xiaoyuan LI ; Qiang CHEN ; Hui WANG ; Zheng ZHANG ; Mengmeng LIU ; Chengfei ZHANG ; Xuedong ZHOU ; Shaohua GE
International Journal of Oral Science 2025;17(1):61-61
Cemental tear is a rare and indetectable condition unless obvious clinical signs present with the involvement of surrounding periodontal and periapical tissues. Due to its clinical manifestations similar to common dental issues, such as vertical root fracture, primary endodontic diseases, and periodontal diseases, as well as the low awareness of cemental tear for clinicians, misdiagnosis often occurs. The critical principle for cemental tear treatment is to remove torn fragments, and overlooking fragments leads to futile therapy, which could deteriorate the conditions of the affected teeth. Therefore, accurate diagnosis and subsequent appropriate interventions are vital for managing cemental tear. Novel diagnostic tools, including cone-beam computed tomography (CBCT), microscopes, and enamel matrix derivatives, have improved early detection and management, enhancing tooth retention. The implementation of standardized diagnostic criteria and treatment protocols, combined with improved clinical awareness among dental professionals, serves to mitigate risks of diagnostic errors and suboptimal therapeutic interventions. This expert consensus reviewed the epidemiology, pathogenesis, potential predisposing factors, clinical manifestations, diagnosis, differential diagnosis, treatment, and prognosis of cemental tear, aiming to provide a clinical guideline and facilitate clinicians to have a better understanding of cemental tear.
Humans
;
Dental Cementum/injuries*
;
Consensus
;
Diagnosis, Differential
;
Cone-Beam Computed Tomography
;
Tooth Fractures/therapy*

Result Analysis
Print