1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Research on the construction and application of blood standard system in China
Jin GUO ; Hongjie WANG ; Xin SHI ; Yong WANG
Chinese Journal of Blood Transfusion 2026;39(4):564-570
Blood standardization is a crucial means of promoting the healthy and sustainable development of China's blood industry. The construction of a blood standard system serves as the foundational work for blood standardization. To facilitate the continuous improvement of blood standardization efforts, this paper begins by describing the current status and analyzing the issues within China's blood standard system. Through systematic research, it proposes a framework for constructing a blood standard system and offers revision recommendations for its enhancement. Based on the first five editions of the blood standard system developed by Sub-Committee of Blood Standards of National Committee of Health Standards, this study further refines the revision and detailed construction of the standards framework—the primary task in establishing the blood standard system. It provides specific guidance for both the construction and application of the blood standard system. This work serves as a reference and basis for the reasonable and standardized formulation and revision of blood standards, as well as for the management and implementation of blood standardization efforts.
3.Analysis of factors influencing temporary deferral and return to donation due to abnormal blood pressure in pre-donation screening
Jin YANG ; Li SUN ; Qiyong BI ; Jingyao WANG ; Yong WANG
Chinese Journal of Blood Transfusion 2026;39(1):56-61
Objective: To analyze the demographic characteristics, return donation patterns, and risk of adverse reactions among donors temporarily deferred due to blood pressure abnormalities, so as to provide an evidence-based foundation for optimizing pre-donation blood pressure screening strategies, enhancing donor retention, and ensuring blood supply safety. Methods: Data from 2.939 million donor instances were collected through the Information Management System at the Beijing Red Cross Blood Center between January 2015 and August 2025. The analysis specifically focused on the 11 600 instances of donors temporarily deferred due to abnormal blood pressure, examining demographic characteristics (age, and gender) and donation-related features (number of donations, donation site, and type of donation). Further analysis was conducted on the return donation patterns, including the return rate, time interval to return, and the incidence, type, and severity of adverse reactions among returned donors. Results: Distribution of abnormal blood pressure: Among the 11 600 instances of abnormal blood pressure, the prevalence was significantly higher in males (0.48%, 10 111/2 086 909) than in females (0.17%, 1 465/852 090). The 46-55 age group had the highest prevalence (0.88%, 2 925/329 235), and the differences across age groups were statistically significant. The prevalence was, higher among repeat donors (0.41%, 5 242/1 276 452) than first-time donors (0.38%, 6 334/1 662 547). The prevalence at mobile donation sites outside the blood center (0.06%, 350/596 104) was higher than fixed donor centers (0.50%, 10 225/2 052 290) and group donation drives (0.34%, 1 001/290 608). Return donations: A total of 19.49% (2 256 out of 11 576) deferred donors returner and successfully donated. Among these donors, 36.17% (816 out of 2 256) returned within 7 days, while the highest proportion of returns was observed within 31-182 days (25.44%, 574/2 256). A higher return rate was observed among male donors (20.17%, 2 039/1 0111) compared to female donors (14.81%, 217/1 465). The return rate for repeat donors (43.02%, 2 255/5 242) was significantly higher than that of first-time donors (0.02%, 1/6 334). Individual donors showed a higher return rate (20.95%, 1 986/9 479) than group donors (12.88%, 270/2 097), with all differences being statistically significant (P<0.05). The differences in return rates across age groups were not statistically significant (P>0.05). Adverse reactions: The incidence of adverse reactions after return was 0.09% (2/2 256), significantly lower than the overall adverse reaction incidence during the same period (0.20%, 5 981/2 938 999). Both adverse reactions were local reaction (category A1, pain or bruising at the puncture site), with no reported cases of systemic vasovagal reactions (VR) or severe adverse events. Conclusion: The current blood pressure screening criteria may lead to the unnecessary deferral of eligible donors. The risk of adverse reactions is extremely low among returned donors who were deferred for abnormal blood pressure. A relaxation of the blood pressure screening criteria is therefore suggested, coupled with the optimization of donation site environment and blood pressure measurement procedure with reference to expert consensus to enhance donor retention and blood supply safety.
4.Cost-effectiveness of Fractional Flow Reserve Versus Intravascular Ultrasound to Guide Percutaneous Coronary Intervention: Results From the FLAVOUR Study
Doyeon HWANG ; Hea-Lim KIM ; Jane KO ; HyunJin CHOI ; Hanna JEONG ; Sun-ae JANG ; Xinyang HU ; Jeehoon KANG ; Jinlong ZHANG ; Jun JIANG ; Joo-Yong HAHN ; Chang-Wook NAM ; Joon-Hyung DOH ; Bong-Ki LEE ; Weon KIM ; Jinyu HUANG ; Fan JIANG ; Hao ZHOU ; Peng CHEN ; Lijiang TANG ; Wenbing JIANG ; Xiaomin CHEN ; Wenming HE ; Sung Gyun AHN ; Ung KIM ; You-Jeong KI ; Eun-Seok SHIN ; Hyo-Soo KIM ; Seung-Jea TAHK ; JianAn WANG ; Tae-Jin LEE ; Bon-Kwon KOO ;
Korean Circulation Journal 2025;55(1):34-46
Background and Objectives:
The Fractional Flow Reserve and Intravascular UltrasoundGuided Intervention Strategy for Clinical Outcomes in Patients with Intermediate Stenosis (FLAVOUR) trial demonstrated non-inferiority of fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) compared with intravascular ultrasound (IVUS)-guided PCI. We sought to investigate the cost-effectiveness of FFR-guided PCI compared to IVUS-guided PCI in Korea.
Methods:
A 2-part cost-effectiveness model, composed of a short-term decision tree model and a long-term Markov model, was developed for patients who underwent PCI to treat intermediate stenosis (40% to 70% stenosis by visual estimation on coronary angiography).The lifetime healthcare costs and quality-adjusted life-years (QALYs) were estimated from the healthcare system perspective. Transition probabilities were mainly referred from the FLAVOUR trial, and healthcare costs were mainly obtained through analysis of Korean National Health Insurance claims data. Health utilities were mainly obtained from the Seattle Angina Questionnaire responses of FLAVOUR trial participants mapped to EQ-5D.
Results:
From the Korean healthcare system perspective, the base-case analysis showed that FFR-guided PCI was 2,451 U.S. dollar lower in lifetime healthcare costs and 0.178 higher in QALYs compared to IVUS-guided PCI. FFR-guided PCI remained more likely to be cost-effective over a wide range of willingness-to-pay thresholds in the probabilistic sensitivity analysis.
Conclusions
Based on the results from the FLAVOUR trial, FFR-guided PCI is projected to decrease lifetime healthcare costs and increase QALYs compared with IVUS-guided PCI in intermediate coronary lesion, and it is a dominant strategy in Korea.
5.Cost-effectiveness of Fractional Flow Reserve Versus Intravascular Ultrasound to Guide Percutaneous Coronary Intervention: Results From the FLAVOUR Study
Doyeon HWANG ; Hea-Lim KIM ; Jane KO ; HyunJin CHOI ; Hanna JEONG ; Sun-ae JANG ; Xinyang HU ; Jeehoon KANG ; Jinlong ZHANG ; Jun JIANG ; Joo-Yong HAHN ; Chang-Wook NAM ; Joon-Hyung DOH ; Bong-Ki LEE ; Weon KIM ; Jinyu HUANG ; Fan JIANG ; Hao ZHOU ; Peng CHEN ; Lijiang TANG ; Wenbing JIANG ; Xiaomin CHEN ; Wenming HE ; Sung Gyun AHN ; Ung KIM ; You-Jeong KI ; Eun-Seok SHIN ; Hyo-Soo KIM ; Seung-Jea TAHK ; JianAn WANG ; Tae-Jin LEE ; Bon-Kwon KOO ;
Korean Circulation Journal 2025;55(1):34-46
Background and Objectives:
The Fractional Flow Reserve and Intravascular UltrasoundGuided Intervention Strategy for Clinical Outcomes in Patients with Intermediate Stenosis (FLAVOUR) trial demonstrated non-inferiority of fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) compared with intravascular ultrasound (IVUS)-guided PCI. We sought to investigate the cost-effectiveness of FFR-guided PCI compared to IVUS-guided PCI in Korea.
Methods:
A 2-part cost-effectiveness model, composed of a short-term decision tree model and a long-term Markov model, was developed for patients who underwent PCI to treat intermediate stenosis (40% to 70% stenosis by visual estimation on coronary angiography).The lifetime healthcare costs and quality-adjusted life-years (QALYs) were estimated from the healthcare system perspective. Transition probabilities were mainly referred from the FLAVOUR trial, and healthcare costs were mainly obtained through analysis of Korean National Health Insurance claims data. Health utilities were mainly obtained from the Seattle Angina Questionnaire responses of FLAVOUR trial participants mapped to EQ-5D.
Results:
From the Korean healthcare system perspective, the base-case analysis showed that FFR-guided PCI was 2,451 U.S. dollar lower in lifetime healthcare costs and 0.178 higher in QALYs compared to IVUS-guided PCI. FFR-guided PCI remained more likely to be cost-effective over a wide range of willingness-to-pay thresholds in the probabilistic sensitivity analysis.
Conclusions
Based on the results from the FLAVOUR trial, FFR-guided PCI is projected to decrease lifetime healthcare costs and increase QALYs compared with IVUS-guided PCI in intermediate coronary lesion, and it is a dominant strategy in Korea.
6.Application of dual-layer spectral CT low-contrast agent protocol in follow-up examinations of pediatric abdominal tumors
Xiaoshan LIU ; Lutong ZHANG ; Zhaorui SUN ; Yong HUANG ; Qianyu LIU ; Qiang TANG ; Yingxuan WANG ; Yuqin JIN
Chinese Journal of Radiology 2025;59(9):1011-1016
Objective:To explore the value of dual-layer spectral CT virtual monoenergetic images (VMI) in contrast-enhanced abdominal CT scans with reduced contrast medium volume in pediatric tumor patients.Methods:The study is a self-matched case-control study. From January to October 2024, pediatric patients admitted to Shandong Cancer Hospital with abdominal tumors who underwent low contrast dose spectral CT contrast-enhanced scans during follow-up were prospectively included. A total of 47 patients aged (6.2±2.2) years (4-14 years) were enrolled. Usual contrast dose enhanced CT served as the conventional-dose group, while the follow-up low-dose spectral CT scans employed a protocol with half the contrast agent dose (low-dose group). Images were reconstructed as conventional CT images and VMI at 45, 55, and 65 keV. Using muscle as the reference background, differences in CT values and contrast-to-noise ratio (CNR) in the aorta, kidneys, liver, and spleen were compared between the low-dose group and conventional-dose group. Multi-group comparisons were performed using the Friedman test. Post-hoc pairwise comparisons were conducted with Bonferroni correction for P-values. Results:CT values and CNRs for all measured regions progressively increased with decreasing keV levels in spectral CT VMI. Significant overall differences were found in CT values and CNRs for the aorta, kidneys, liver, and spleen among the low-dose group (all VMIs) and the conventional-dose group (all P<0.001). At 65 keV VMI in the low-dose group, both CT values and CNRs (except for the liver CNR) were significantly lower than those in the conventional-dose group (all adjusted P<0.05). At 55 keV VMI in the low-dose group, CT values and CNRs for all regions did not show statistically significant differences compared to the conventional-dose group (all adjusted P>0.05). At 45 keV VMI in the low-dose group, CT values for all structures and CNR for the spleen were significantly higher than those in the conventional-dose group (all adjusted P<0.05). However, no statistically significant difference was found in CNRs for the aorta, kidneys, and liver (adjusted P=1.000, 0.313, and 0.503, respectively). Conclusion:When the contrast dose is halved, spectral CT 45 keV VMI enhances CT attenuation values and CNR in the abdomen of pediatric tumor patients, while 55 keV VMI provides image quality comparable to that of conventional-dose CT.
7.Clinical effects of Jiawei Yanghe Decoction combined with Budesonide and Formoterol Fumarate Powder for Inhalation on patients with mild to moderate bronchial asthma in chronic and persistent period
Yu WANG ; Hui-yong ZHANG ; Lin-jin CHEN ; Zheng-yi ZHANG ; Cui LI ; Jie CUI ; Ben SU ; Ping BAI ; Zi-feng MA ; Zhen-hui LU
Chinese Traditional Patent Medicine 2025;47(1):81-86
AIM To explore the clinical effects of Jiawei Yanghe Decoction combined with Budesonide and Formoterol Fumarate Powder for Inhalation on patients with mild to moderate bronchial asthma in chronic and persistent period.METHODS One hundred and eighteen patients were randomly assigned into control group(59 cases)for 4-week administration of Budesonide and Formoterol Fumarate Powder for Inhalation,and observation group(59 cases)for 4-week administration of both Jiawei Yanghe Decoction and Budesonide and Formoterol Fumarate Powder for Inhalation.The changes in clinical effects,ACT score,bronchial asthma control rate,pulmonary function indices(FEV1,PEF,FEV1%,PEF%),inflammatory indices(EOS,EOS%,FeNO),TCM syndrome score and incidence of adverse reactions were detected.RESULTS The observation group demonstrated higher total effective rate than the control group(P<0.05).After the treatment,the two groups displayed increased bronchial asthma control rate,ACT score,PEF(P<0.05),and decreased TCM syndrome score(P<0.05),especially for the observation group(P<0.05);the observation group exhibited increased FEV1,FEV1%,PEF%(P<0.05),among which FEV1,PEF%were higher than those in the control group(P<0.05);the observation group showed decreased inflammatory indices(P<0.05),among which FeNO was lower than that in the control group(P<0.05).No significant difference in incidence of adverse reactions was found between the two groups(P>0.05).CONCLUSION For the patients with mild to moderate bronchial asthma in chronic and persistent period,Jiawei Yanghe Decoction combined with Budesonide and Formoterol Fumarate Powder for Inhalation can safely and effectively alleviate clinical symptoms,improve pulmonary functions,airway inflammatory reactions,and enhance bronchial asthma control rate.
8.Changing prevalence and antibiotic resistance profiles of carbapenem-resistant Enterobacterales in hospitals across China:data from CHINET Antimicrobial Resistance Surveillance Program,2015-2021
Wenxiang JI ; Tong JIANG ; Jilu SHEN ; Yang YANG ; Fupin HU ; Demei ZHU ; Yuanhong XU ; Ying HUANG ; Fengbo ZHANG ; Ping JI ; Yi XIE ; Mei KANG ; Chuanqing WANG ; Pan FU ; Yingchun XU ; Xiaojiang ZHANG ; Ziyong SUN ; Zhongju CHEN ; Yuxing NI ; Jingyong SUN ; Yunzhuo CHU ; Sufei TIAN ; Zhidong HU ; Jin LI ; Yunsong YU ; Jie LIN ; Bin SHAN ; Yan DU ; Sufang GUO ; Lianhua WEI ; Fengmei ZOU ; Yunjian HU ; Xiaoman AI ; Chao ZHUO ; Danhong SU ; Dawen GUO ; Jinying ZHAO ; Hua YU ; Xiangning HUANG ; Wen'en LIU ; Yanming LI ; Yan JIN ; Chunhong SHAO ; Xuesong XU ; Chao YAN ; Shanmei WANG ; Yafei CHU ; Lixia ZHANG ; Juan MA ; Shuping ZHOU ; Yan ZHOU ; Lei ZHU ; Jinhua MENG ; Fang DONG ; Zhiyong LÜ ; Fangfang HU ; Han SHEN ; Wanqing ZHOU ; Wei JIA ; Gang LI ; Jinsong WU ; Yuemei LU ; Jihong LI ; Jinju DUAN ; Jianbang KANG ; Xiaobo MA ; Yanping ZHENG ; Ruyi GUO ; Yan ZHU ; Yunsheng CHEN ; Qing MENG ; Shifu WANG ; Xuefei HU ; Hong ZHANG ; Chun WANG ; Wenhui HUANG ; Ruizhong WANG ; Hua FANG ; Bixia YU ; Yong ZHAO ; Ping GONG ; Kaizhen WENG ; Yirong ZHANG ; Jiangshan LIU ; Longfeng LIAO ; Hongqin GU ; Lin JIANG ; Wen HE ; Shunhong XUE ; Jiao FENG ; Chunlei YUE
Chinese Journal of Infection and Chemotherapy 2025;25(4):445-454
Objective To summarize the changing prevalence of carbapenem resistance in Enterobacterales based on the data of CHINET Antimicrobial Resistance Surveillance Program from 2015 to 2021 for improving antimicrobial treatment in clinical practice.Methods Antimicrobial susceptibility testing was performed using a commercial automated susceptibility testing system according to the unified CHINET protocol.The results were interpreted according to the breakpoints of the Clinical & Laboratory Standards Institute(CLSI)M100 31st ed in 2021.Results Over the seven-year period(2015-2021),the overall prevalence of carbapenem-resistant Enterobacterales(CRE)was 9.43%(62 342/661 235).The prevalence of CRE strains in Klebsiella pneumoniae,Citrobacter freundii,and Enterobacter cloacae was 22.38%,9.73%,and 8.47%,respectively.The prevalence of CRE strains in Escherichia coli was 1.99%.A few CRE strains were also identified in Salmonella and Shigella.The CRE strains were mainly isolated from respiratory specimens(44.23±2.80)%,followed by blood(20.88±3.40)%and urine(18.40±3.45)%.Intensive care units(ICUs)were the major source of the CRE strains(27.43±5.20)%.CRE strains were resistant to all the β-lactam antibiotics tested and most non-β-lactam antimicrobial agents.The CRE strains were relatively susceptible to tigecycline and polymyxins with low resistance rates.Conclusions The prevalence of CRE strains was increasing from 2015 to 2021.CRE strains were highly resistant to most of the antibacterial drugs used in clinical practice.Clinicians should prescribe antimicrobial agents rationally.Hospitals should strengthen antibiotic stewardship in key clinical settings such as ICUs,and take effective infection control measures to curb CRE outbreak and epidemic in hospitals.
9.Changing distribution and antibiotic resistance profiles of the respiratory bacterial isolates in hospitals across China:data from CHINET Antimicrobial Resistance Surveillance Program,2015-2021
Ying FU ; Yunsong YU ; Jie LIN ; Yang YANG ; Fupin HU ; Demei ZHU ; Yingchun XU ; Xiaojiang ZHANG ; Fengbo ZHANG ; Ping JI ; Yi XIE ; Mei KANG ; Chuanqing WANG ; Pan FU ; Yuanhong XU ; Ying HUANG ; Ziyong SUN ; Zhongju CHEN ; Yuxing NI ; Jingyong SUN ; Yunzhuo CHU ; Sufei TIAN ; Zhidong HU ; Jin LI ; Bin SHAN ; Yan DU ; Sufang GUO ; Lianhua WEI ; Fengmei ZOU ; Hong ZHANG ; Chun WANG ; Yunjian HU ; Xiaoman AI ; Chao ZHUO ; Danhong SU ; Dawen GUO ; Jinying ZHAO ; Hua YU ; Xiangning HUANG ; Wen'en LIU ; Yanming LI ; Yan JIN ; Chunhong SHAO ; Xuesong XU ; Chao YAN ; Shanmei WANG ; Yafei CHU ; Lixia ZHANG ; Juan MA ; Shuping ZHOU ; Yan ZHOU ; Lei ZHU ; Jinhua MENG ; Fang DONG ; Zhiyong LÜ ; Fangfang HU ; Han SHEN ; Wanqing ZHOU ; Wei JIA ; Gang LI ; Jinsong WU ; Yuemei LU ; Jihong LI ; Jinju DUAN ; Jianbang KANG ; Xiaobo MA ; Yanping ZHENG ; Ruyi GUO ; Yan ZHU ; Yunsheng CHEN ; Qing MENG ; Shifu WANG ; Xuefei HU ; Jilu SHEN ; Ruizhong WANG ; Hua FANG ; Bixia YU ; Yong ZHAO ; Ping GONG ; Kaizhen WENG ; Yirong ZHANG ; Jiangshan LIU ; Longfeng LIAO ; Hongqin GU ; Lin JIANG ; Wen HE ; Shunhong XUE ; Jiao FENG ; Chunlei YUE ; Wenhui HUANG
Chinese Journal of Infection and Chemotherapy 2025;25(4):431-444
Objective To characterize the changing species distribution and antibiotic resistance profiles of respiratory isolates in hospitals participating in the CHINET Antimicrobial Resistance Surveillance Program from 2015 to 2021.Methods Commercial automated antimicrobial susceptibility testing systems and disk diffusion method were used to test the susceptibility of respiratory bacterial isolates to antimicrobial agents following the standardized technical protocol established by the CHINET program.Results A total of 589 746 respiratory isolates were collected from 2015 to 2021.Overall,82.6%of the isolates were Gram-negative bacteria and 17.4%were Gram-positive bacteria.The bacterial isolates from outpatients and inpatients accounted for(6.0±0.9)%and(94.0±0.1)%,respectively.The top microorganisms were Klebsiella spp.,Acinetobacter spp.,Pseudomonas aeruginosa,Staphylococcus aureus,Haemophilus spp.,Stenotrophomonas maltophilia,Escherichia coli,and Streptococcus pneumoniae.Each microorganism was isolated from significantly more males than from females(P<0.05).The overall prevalence of methicillin-resistant S.aureus(MRSA)was 39.9%.The prevalence of penicillin-resistant S.pneumoniae was 1.4%.The prevalence of extended-spectrum β-lactamase(ESBL)-producing E.coli and K.pneumoniae was 67.8%and 41.3%,respectively.The overall prevalence of carbapenem-resistant E.coli,K.pneumoniae,Enterobacter cloacae,Pseudomonas aeruginosa,and Acinetobacter baumannii was 3.7%,20.8%,9.4%,29.8%,and 73.3%,respectively.The prevalence of β-lactamase was 96.1%in Moraxella catarrhalis and 60.0%in Haemophilus influenzae.The H.influenzae isolates from children(<18 years)showed significantly higher resistance rates to β-lactam antibiotics than the isolates from adults(P<0.05).Conclusions Gram-negative bacteria are still predominant in respiratory isolates associated with serious antibiotic resistance.Antimicrobial resistance surveillance should be strengthened in clinical practice to support accurate etiological diagnosis and appropriate antimicrobial therapy based on antimicrobial susceptibility testing results.
10.Vonoprazan for ulcers associated with endoscopic submucosal dissection:a rapid health technology assessment
Wei WANG ; Yijun KE ; Chang CHENG ; Chongwen FANG ; Lisheng PAN ; Yong JIN ; Yanping ZHANG
Chinese Journal of Pharmacoepidemiology 2025;34(3):306-313
Objective To evaluate the efficacy,safety and economy of vonoprazan in the treatment of post-endoscopic submucosal dissection(ESD)ulcer by rapid health technology assessment method,and to provide reference for clinical treatment decision.Methods PubMed,Cochrane Library,Embase,ScienceDirect,CNKI,WanFang Data databases and the official website of health technology assessment(HTA)agency were electronically searched to collect HTA reports,systematic reviews/Meta-analysis and pharmacoeconomic studies of vonoprazan in the treatment of post-ESD ulcer from inception to July 31,2024.Two researchers independently screened literature,extracted data,and comprehensively analyzed the results of the included literature on the basis of literature quality evaluation.Results A total of 8 studies were included,all were systematic reviews/Meta-analysis.In terms of effectiveness,compared with proton pump inhibitors(PPI),vonoprazan significantly increased the overall ulcer healing rate after ESD and more rapid reduction of ulcer area(P<0.05).The results of subgroup analysis showed that there was no significant difference in ulcer healing rate between vonoprazan and PPI treatment at 4 or 8 weeks after ESD(P>0.05).Vonoprazan significantly increased the rate of postoperative ulcer reduction in H.pylori positive patients compared with PPI(P<0.05).In terms of safety,compared with PPI,vonoprazan reduced the incidence of overall adverse events rate(P<0.05).The difference in the incidence of delayed bleeding and ulcer perforation between vonoprazan and PPIs showed no statistically significant difference.(P>0.05).Conclusion Vonoprazan demonstrated favorable efficacy and safety in the treatment of ESD ulcers,and further economic studies are warranted.

Result Analysis
Print
Save
E-mail