1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Operational management survey and countermeasure research of tertiary maternal and child health hospitals in guizhou province
Zhenglian LONG ; Jin YANG ; Fei GUO ; Huatao PENG ; Hanbing HE
Modern Hospital 2025;25(7):1083-1087
Objective To investigate the current status of operational management in tertiary maternal and child health(MCH)hospitals in Guizhou Province and propose recommendations for refining their operational management practices.Meth-ods A self-designed electronic questionnaire was distributed to seven tertiary MCH hospitals in Guizhou Province.The survey fo-cused on fundamental dimensions of operational management,particularly the implementation of refined management practices,with results analyzed using descriptive statistics.Results Among the seven hospitals,five had independently established opera-tional management departments,with three staffing 3-4 personnel.Sixty percent of the hospitals engaged in data statistics,strate-gic management,and process optimization.Only two hospitals had implemented operational management information systems(HRP),but these systems featured incomplete modules and lacked interconnectivity between subsystems,failing to meet opera-tional needs.Additionally,while total expenditures increased year-over-year across all hospitals,insufficient government compen-sation has heightened operational pressures.Conclusions Operational management in Guizhou's tertiary MCH hospitals faces multiple challenges,including incomplete organizational structures and systems,inadequate execution of core functions,subopti-mal information systems for refined management,and limited fiscal support.Recommendations include establishing a multi-tiered operational management framework,implementing comprehensive long-term safeguards,and developing an integrated data man-agement platform.Simultaneously,improving government compensation mechanisms through increased fiscal investment and sup-portive policies is critical to enhancing operational capabilities and achieving high-quality development.
3.Predictive value of bpMRI for pelvic lymph node metastasis in prostate cancer patients with PSA≤20 μg/L.
Lai DONG ; Rong-Jie SHI ; Jin-Wei SHANG ; Zhi-Yi SHEN ; Kai-Yu ZHANG ; Cheng-Long ZHANG ; Bin YANG ; Tian-Bao HUANG ; Ya-Min WANG ; Rui-Zhe ZHAO ; Wei XIA ; Shang-Qian WANG ; Gong CHENG ; Li-Xin HUA
National Journal of Andrology 2025;31(5):426-431
Objective: The aim of this study is to explore the predictive value of biparametric magnetic resonance imaging(bpMRI)for pelvic lymph node metastasis in prostate cancer patients with PSA≤20 μg/L and establish a nomogram. Methods: The imaging data and clinical data of 363 patients undergoing radical prostatectomy and pelvic lymph node dissection in the First Affiliated Hospital of Nanjing Medical University from July 2018 to December 2023 were retrospectively analyzed. Univariate analysis and multivariate logistic regression were used to screen independent risk factors for pelvic lymph node metastasis in prostate cancer, and a nomogram of the clinical prediction model was established. Calibration curves were drawn to evaluate the accuracy of the model. Results: Multivariate logistic regression analysis showed extrocapusular extension (OR=8.08,95%CI=2.62-24.97, P<0.01), enlargement of pelvic lymph nodes (OR=4.45,95%CI=1.16-17.11,P=0.030), and biopsy ISUP grade(OR=1.97,95%CI=1.12-3.46, P=0.018)were independent risk factors for pelvic lymph node metastasis. The C-index of the prediction model was 0.834, which indicated that the model had a good prediction ability. The actual value of the model calibration curve and the prediction probability of the model fitted well, indicating that the model had a good accuracy. Further analysis of DCA curve showed that the model had good clinical application value when the risk threshold ranged from 0.05 to 0.70.Conclusion: For prostate cancer patients with PSA≤20 μg/L, bpMRI has a good predictive value for the pelvic lymph node metastasis of prostate cancer with extrocapusular extension, enlargement of pelvic lymph nodes and ISUP grade≥4.
Humans
;
Male
;
Prostatic Neoplasms/diagnostic imaging*
;
Lymphatic Metastasis
;
Retrospective Studies
;
Nomograms
;
Prostate-Specific Antigen/blood*
;
Lymph Nodes/pathology*
;
Pelvis
;
Predictive Value of Tests
;
Prostatectomy
;
Lymph Node Excision
;
Risk Factors
;
Magnetic Resonance Imaging
;
Logistic Models
;
Middle Aged
;
Aged
4.Shenmai Injection Reduces Cardiomyocyte Apoptosis Induced by Doxorubicin through miR-30a/Bcl-2.
Xiao-Nan ZHANG ; Yan-Yang LI ; Shi-Chao LYU ; Qiu-Jin JIA ; Jun-Ping ZHANG ; Long-Tao LIU
Chinese journal of integrative medicine 2025;31(3):240-250
OBJECTIVE:
To explore the molecular mechanism of Shenmai Injection (SMI) against doxorubicin (DOX) induced cardiomyocyte apoptosis.
METHODS:
A total of 40 specific pathogen-free (SPF) male Sprague Dawley (SD) male rats were divided into 5 groups based on the random number table, including the control group, the model group, miR-30a agomir group, SMI low-dose (SMI-L) group, and SMI high-dose (SMI-H) group, with 8 rats in each group. Except for the control group, the rats were injected weekly with DOX (2 mg/kg) in the tail vein for 4 weeks to induce myocardial injury, and were given different regimens of continuous intervention for 2 weeks. Cardiac function was detected by echocardiography and myocardial pathological changes were observed by Van Gieson (VG) staining. Myocardial injury serum markers, including creatine kinase (CK), lactate dehydrogenase (LDH), troponin T (cTnT), N-terminal pro-brain natriuretic peptide (NT-proBNP), soluble ST2 (sST2), and growth differentiation factor-15 (GDF-15) were detected by enzyme linked immunosorbent assay (ELISA). Cardiomyocyte apoptosis was observed by terminal deoxynucleotidyl transferase-mediated biotinylated dUTP triphosphate nick end labeling (TUNEL) and transmission electron microscopy, and the expressions of target proteins and mRNA were detected by Western blot and quantitative real time polymerase chain reaction (qRT-RCR), respectively.
RESULTS:
The treatment with different doses of SMI reduced rat heart mass index and left ventricular mass index (P<0.05), significantly improved the left ventricular ejection fraction (P<0.05), decreased the levels of serum CK, LDH, cTnT, and NT-proBNP (P<0.05 or P<0.01), reduced the levels of serum sST2 and GDF-15 (P<0.05 or P<0.01), decreased the collagen volume fraction, reduced the expressions of rat myocardial type I and type III collagen (P<0.05 or P<0.01), and effectively alleviated myocardial fibrosis. And the study found that SMI promoted the expression levels of miR-30a and Bcl-2 in myocardium, and down-regulated the expression of Bax, which inhibited the activation of Caspase-3 and Caspase-9 (P<0.05 or P<0.01), and improved myocardial cell apoptosis.
CONCLUSIONS
SMI can alleviate myocardial injury and apoptosis caused by DOX, and its mechanism possibly by promoting the targeted expression of myocardial Bcl-2 protein through miR-30a.
Animals
;
Myocytes, Cardiac/metabolism*
;
Apoptosis/drug effects*
;
MicroRNAs/genetics*
;
Rats, Sprague-Dawley
;
Male
;
Drugs, Chinese Herbal/administration & dosage*
;
Doxorubicin/pharmacology*
;
Proto-Oncogene Proteins c-bcl-2/genetics*
;
Drug Combinations
;
Injections
;
Rats
5.Diagnostic value of high-resolution temporal bone CT combined with DW-MRI fusion technology in middle ear cholesteatoma.
Qimei YANG ; Yaya CAO ; Long JIN ; Jin ZHANG ; Jinrui MA ; Wen ZHANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(12):1120-1125
Objective:To explore the application value of high-resolution temporal bone CT and DW-MRI fusion technology in achieving precise diagnosis and anatomical localization of middle ear cholesteatoma during endoscopic surgery. Methods:Eighteen patients initially diagnosed with middle ear cholesteatoma in the Department of Otolaryngology Head and Neck Surgery, Shaanxi Provincial People's Hospital, from January to June 2024 were enrolled.Preoperative high-resolution temporal bone CT and DW-MRI were performed, and rtStation software was used for image fusion to construct CT-MRI fused images. The involvement of cholesteatoma in six anatomical subregions of the temporal bone was evaluated. Using surgical pathology as the gold standard, and combining surgical videos and anatomical records, the sensitivity, specificity, and accuracy of pure CT, pure DW-MRI, and CT-MRI fused images in evaluating middle ear cholesteatoma lesions were compared. Results:A total of 18 patients were included, and 17 cases were pathologically confirmed as middle ear cholesteatoma postoperatively. The sensitivity of the preoperative of preoperative CT was 100%, but the specificity was only 44.44%, with an overall accuracy of 72.22%; the sensitivity and specificity of DW-MRI evaluation were 81.46% and 85.19%, the accuracy was 83.33%, respectively. In contrast, the sensitivity and specificity of CT-MRI fusion image to the spatial localization of cholesteatoma were higher than that of DW-MRI alone(92.59% vs 81.46%; 98.15% vs 85.19%), and the diagnostic accuracy was also significantly improved(95.37% vs 83.33%). The Kappa values for the agreement between HRCT, DW-MRI, and CT-MRI segmentation localization and pathological results were 0.444, 0.667, and 0.907 respectively. The chi-square paired t-test confirmed statistically significant diagnostic differences between groups(P<0.001). Results demonstrated that CT-MRI significantly outperformed HRCT and DW-MRI in diagnostic efficacy for segmental localization of primary posterior congenital middle ear cholesteatoma. Conclusion:High-resolution temporal bone CT combined with DW-MRI fusion technology demonstrates higher sensitivity, specificity, and accuracy in the diagnosis and spatial localization of middle ear cholesteatoma than single imaging modalities. It can provide more precise evaluation of lesion scope for endoscopic surgery, showing important clinical application value.
Humans
;
Cholesteatoma, Middle Ear/diagnostic imaging*
;
Tomography, X-Ray Computed
;
Temporal Bone/diagnostic imaging*
;
Diffusion Magnetic Resonance Imaging
;
Female
;
Male
;
Adult
;
Sensitivity and Specificity
;
Middle Aged
;
Endoscopy
6.Expert consensus on the clinical strategies for orthodontic treatment with clear aligners.
Yan WANG ; Hu LONG ; Zhihe ZHAO ; Ding BAI ; Xianglong HAN ; Jun WANG ; Bing FANG ; Zuolin JIN ; Hong HE ; Yuxin BAI ; Weiran LI ; Min HU ; Yanheng ZHOU ; Hong AI ; Yuehua LIU ; Yang CAO ; Jun LIN ; Huang LI ; Jie GUO ; Wenli LAI
International Journal of Oral Science 2025;17(1):19-19
Clear aligner treatment is a novel technique in current orthodontic practice. Distinct from traditional fixed orthodontic appliances, clear aligners have different material features and biomechanical characteristics and treatment efficiencies, presenting new clinical challenges. Therefore, a comprehensive and systematic description of the key clinical aspects of clear aligner treatment is essential to enhance treatment efficacy and facilitate the advancement and wide adoption of this new technique. This expert consensus discusses case selection and grading of treatment difficulty, principle of clear aligner therapy, clinical procedures and potential complications, which are crucial to the clinical success of clear aligner treatment.
Humans
;
Consensus
;
Orthodontic Appliance Design
;
Orthodontic Appliances, Removable
;
Tooth Movement Techniques/methods*
;
Malocclusion/therapy*
;
Orthodontics, Corrective/instrumentation*
8.Formulation and Explanation of the Standard for Drug Quality Problems Handling
Jiadan YANG ; Yongqing CHEN ; Long MENG ; Jin LU ; Zilang LUO ; Feng QIU ; Jiancun ZHEN
Herald of Medicine 2025;44(5):708-711
Drug quality problems seriously threaten the life and health of patients,drug quality problems handling is an important part of pharmaceutical management in medical institutions,and strengthening the management of drug quality problems in medical institutions can provide a strong guarantee for drug safety of patients.This standard was compiled by the Pharmaceutical Affairs Commission of the Chinese Hospital Association,and the process included problems identification,framework development,manuscript writing,opinions gathering,expert argumentation and deliberation,and standards development.The standard regulates the basic requirements,coping strategies,quality control and continuous improvement of drug quality problems handling in medical institutions.This article elaborates on the methods and contents of formulating standards for drug quality problems handling,to pro-vide reference and inspiration for medical institutions to carry out drug quality problems handling.
9.Expert consensus on clinical treatment of acute radiation syndrome from external irradiation
Li LIANG ; Long YUAN ; Changlin YU ; Qingjie LIU ; Yulong LIU ; Wenfeng YANG ; Jin WANG ; Weixu HUANG ; Ying LIU ; Cuiping LEI ; Huifang CHEN ; Ximing FU ; Baoshan CAO ; Mopei WANG ; Zhaohui ZHANG ; Yu XIAO ; Yamei CHEN ; Quanfu SUN
Chinese Journal of Radiological Medicine and Protection 2025;45(9):827-839
China emerges as a major country in nuclear energy development and the application of nuclear and radiologic technology. The diagnosis and treatment of acute radiation syndrom (ARS) caused by external irradiation represent a core function in the country′s medical rescue of nuclear and radiological emergencies. Clinically, ARS manifests hematopoietic, gastrointestinal, cutaneous, and central nervous system syndromes, with specific clinical manifestations, signs, severity, and prognosis strongly correlated with radiation dose. China has established a number of national and provincial centers for treating radiation-induced damage. Nevertheless, most medical staff have limited experience in ARS treatment. This consensus presents a summary of recent experience in treating ARS of China. In combination with recommendations from international organizations such as the World Health Organization (WHO), this consensus proposes key evidence of critical clinical issues of ARS, covering all links in the rescue of external irradiation-induced ARS. Initially, clinical diagnosis, syndromes, and severe degrees should be determined based on clinical symptoms and dose estimates. It is necessary to normalize clinical treatment measures for hematopoietic recovery, gastrointestinal injury treatment, infection control, symptomatic treatment, and multi-organ function preservation. To this end, this consensus offers cautions. This consensus provides principles of treatment with traditional Chinese medicine, psychological intervention, and follow-up. Additionally, it highlights multidisciplinary collaboration. It is recommended that this consensus be applied in relevant treatment centers.
10.The value of amide proton transfer imaging in evaluating lymph-vascular space invasion of cervical cancer
Chongshuang YANG ; Jin YANG ; Bo WANG ; Min WU ; Minggui LONG ; Yingbin LUO ; Tianliang SHI
Journal of Practical Radiology 2025;41(5):801-804
Objective To investigate the value of amide proton transfer(APT)imaging in evaluating lymph-vascular space inva-sion(LVSI)of cervical cancer.Methods A retrospective analysis was conducted on the data of cervical cancer patients with patho-logically confirmed LVSI status.Based on the presence of LVSI,the patients were divided into LVSI positive group and LVSI nega-tive group.All patients underwent diffusion weighted imaging(DWI)and APT imaging before treatment,and the apparent diffusion coefficient(ADC)and APT values of the lesions were measured.An independent sample t-test was used to compare the differences in ADC and APT values between the two groups.The sensitivity,specificity and area under the curve(AUC)of ADC,APT and ADC+APT in predicting LVSI were observed by receiver operating characteristic(ROC)curve,and the diagnostic performance of the three was compared by DeLong test.Results A total of 78 patients were included,of which 54 were LVSI negative and 24 were LVSI positive.The ADC values in the LVSI positive group were significantly lower than those in the LVSI negative group(P<0.001),while the APT values in the LVSI positive group were significantly higher than those in the LVSI negative group(P<0.001).The sensitivities of ADC,APT and ADC+APT in predicting LVSI were 79.17%,83.33% and 87.50%,respectively,the specificities were 75.93%,55.56% and 77.78%,respectively,and the AUC were 0.828,0.759 and 0.868,respectively,indicating that the diag-nostic performance of ADC+APT was better than that of ADC and APT alone(P<0.001).Conclusion APT imaging can preop-eratively predict the presence of LVSI status in cervical cancer.When combined with ADC,its diagnostic accuracy is higher than that of APT alone,providing a new approach for evaluating LVSI in cervical cancer.

Result Analysis
Print
Save
E-mail