1.Single-center experience in the treatment of severe aortic stenosis with XcorTM transcatheter aortic valve replacement system: 1-year follow-up results.
Shengwen WANG ; Haozhong LIU ; Haijiang GUO ; Tong TAN ; Hanxiang XIE ; Xiang LIU ; Hailong QIU ; Jimei CHEN ; Huiming GUO ; Jian LIU
Journal of Zhejiang University. Medical sciences 2025;54(2):141-148
OBJECTIVES:
To analyze the early clinical outcomes of the XcorTM transcatheter aortic valve replacement (TAVR) system in treating severe aortic stenosis. This study has been registered at Chinese Clinical Trial Registry (ChiCTR2200065593).
METHODS:
This single-arm, prospective clinical trial enrolled patients with severe aortic stenosis treated with the XcorTM TAVR system at the Section of Heart Valve & Coronary Artery Surgery, Guangdong Provincial People's Hospital. Perioperative and follow-up parameters were compared to evaluate differences in hemodynamic outcomes. All-cause mortality, aortic regurgitation, paravalvular leakage, cerebrovascular events, and reoperation were analyzed.
RESULTS:
Thirty-two patients with severe aortic stenosis were included (20 males, 12 females), with (70.9±4.3) years old and a Society of Thoracic Surgeons (STS) score of 6.45% (6.07%, 7.28%). Notably, 87.5% of patients had New York Heart Association (NYHA) class≥Ⅲ. All patients underwent successful XcorTM bioprosthesis implantation, achieving an immediate technical success rate of 100.0% and device success rate of 96.9%. Mean aortic valve gradient decreased from (55.21±23.17) mmHg (1 mmHg=0.133 kPa) to (8.45±5.30) mmHg, peak aortic jet velocity decreased from (4.66±0.85) m/s to (1.99±0.48) m/s, aortic valve area increased from (0.66±0.21) cm² to (2.09±0.67) cm² (all P<0.01). Intraoperative ventricular fibrillation occurred in one patient, while one case exhibited moderate prosthetic valve regurgitation and paravalvular leakage post-procedure. At 12-month follow-up, sustained improvements were observed in cardiac function, left ventricular ejection fraction, hemodynamic parameters, and SF-12 quality-of-life scores (all P<0.01). All-cause mortality was 12.5% (4/32), with 13.8% (4/29) developing moderate paravalvular leakage.
CONCLUSIONS
The XcorTM TAVR system demonstrated favorable early outcomes in severe aortic stenosis patients, significantly improving symptoms and hemodynamics while exhibiting excellent performance in preventing malignant arrhythmias and coronary obstruction.
Humans
;
Male
;
Female
;
Aortic Valve Stenosis/surgery*
;
Transcatheter Aortic Valve Replacement/methods*
;
Aged
;
Follow-Up Studies
;
Prospective Studies
;
Treatment Outcome
;
Aged, 80 and over
;
Heart Valve Prosthesis
;
Middle Aged
2.Early clinical outcomes of the domestic KokaclipTM transcatheter edge-to-edge mitral valve repair system for severe degenerative mitral regurgitation: A single-arm, prospective, single-group target value clinical trial
Tong TAN ; Bingqi FU ; Peijian WEI ; Nianjin XIE ; Haozhong LIU ; Xiaoyi LI ; Shengwen WANG ; Haijiang GUO ; Jian LIU ; Jimei CHEN ; Jian ZHUANG ; Huiming GUO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(02):269-275
Objective To summarize and analyze the preliminary clinical outcomes of the KokaclipTM transcatheter edge-to-edge mitral valve repair system for severe degenerative mitral regurgitation (DMR). Methods This study was a single-arm, prospective, single-group target value clinical trial that enrolled patients who underwent the KokaclipTM transcatheter edge-to-edge repair (TEER) system for DMR in the Department of Heart Surgery of Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute from June 2022 to January 2023. Differences in the grade of mitral regurgitation (MR) during the perioperative and follow-up periods were compared, and the incidences of adverse events such as all-cause death, thoracotomy conversion, reoperation, and severe recurrence of MR during the study period were investigated. Results The enrolled patient population consisted of 14 (50.0%) females with a mean age of 70.9±5.4 years. Twenty-eight (100.0%) patients were preoperatively diagnosed with typeⅡ DMR, with a prolapse width of 12.5 (11.0, 16.1) mm, a degree of regurgitation 4+ leading to pulmonary venous reflux, and a New York Heart Association cardiac function class≥Ⅲ. All patients completed the TEER procedure successfully, with immediate postoperative improvement of MR to 0, 1+, and 2+ grade in 2 (7.1%), 21 (75.0%), and 5 (17.9%) patients, respectively. Mitral valve gradient was 2.5 (2.0, 3.0) mm Hg. Deaths, thoracotomy conversion, or device complications such as unileaflet clamping, clip dislodgement, or leaflet injury were negative. Twenty-eight (100.0%) patients completed at least 3-month postoperative follow-up with a median follow-up time of 5.9 (3.6, 6.8) months, during which patients had a mean MR grade of 1.0+ (1.0+, 2.0+) grade and a significant improvement from preoperative values (P<0.001). There was no recurrence of ≥3+ regurgitation, pulmonary venous reflux, reoperation, new-onset mitral stenosis, or major adverse cardiovascular events. Twenty-two (78.6%) patients’ cardiac function improved to classⅠorⅡ. Conclusion The domestic KokaclipTM TEER system has shown excellent preliminary clinical results in selected DMR patients with a high safety profile and significant improvement in MR. Additional large sample volume, prospective, multicenter studies, and long-term follow-up are expected to validate the effectiveness of this system in the future.
3.Diagnosis and surgical treatment of high-risk anomalous aortic origin of coronary artery
Hujun CUI ; Jimei CHEN ; Shushui WANG ; Jianzheng CEN ; Gang XU ; Shusheng WEN ; Xiaobing LIU ; Jian ZHUANG
Chinese Journal of Surgery 2024;62(3):242-247
Objective:To analyze the diagnosis and surgical treatment of high-risk anomalous aortic origin of coronary artery (AAOCA).Methods:This is a retrospective case series study. From January 2016 to July 2023, 24 cases of high-risk AAOCA underwent surgical treatment in Department of Cardiac Surgery, Guangdong Provincial People's Hospital. There were 18 males and 6 females, operatively aged ( M (IQR)) 13 (26) years (range: 0.3 to 57.0 years). They were confirmed by cardiac ultrasound and cardiac CT, all of which had anomalous coronary running between the aorta and the pulmonary artery. There were 15 cases of the right coronary artery from the left aortic sinus of Valsalva, 6 cases of left coronary artery from the right aortic sinus of Valsalva, 3 cases of the sigle coronary artery. Only 3 patients had no obvious related symptoms (2 cases were complicated with a positive exercise stress test and 1 case with other intracardiac malformations), 21 cases had a history of chest tightness, chest pain, or syncope after exercise. Three patients suffered syncope after exercise and underwent cardiopulmonary resuscitation (2 cases were treated with an extracorporeal membrane oxygenerator (ECMO)). The gap from the first symptom to the diagnosis was 4.0 (11.5) months (range: 0.2 to 84.0 months). The detection rate of coronary artery abnormalities suggested by the first cardiac ultrasound was only 37.5% (9/24). Seven patients were complicated with other cardiac diseases (4 cases with congenital heart defects, 2 cases with coronary atherosclerotic heart disease, 1 case with mitral valve disease). Results:All 24 patients underwent surgical treatment (23 cases underwent abnormal coronary artery unroofing, 1 case underwent coronary artery bypass grafting), and 5 patients underwent other intracardiac malformation correction at the same time. There were no death or surgery related complications in the hospital for 30 days after the operation. A patient with preoperative extracorporeal cardiopulmonary resuscitation was continuously assisted by ECMO after emergency AAOCA correction and had complications such as limb ischemia necrosis and renal dysfunction after the operation. During the follow-up of 2.2 (3.3) years (range: 1 month to 7.2 years), one patient who previously underwent percutaneous transluminal coronary angioplasty with a stent implant experienced significant postoperative symptomatic relief, and the other discharged patients had no related symptoms.Conclusions:The accurate rate of initial diagnosis for high-risk AAOCA is still low, but the risk of cardiovascular accidents is high. For sports-related chest pain and other symptoms, more attention should be paid to the detection of AAOCA, especially for adolescents. Exercise stress testing can be helpful in evaluating the cardiovascular risk of asymptomatic AAOCA. Instant surgical treatment can achieve satisfactory curative effects.
4.Diagnosis and surgical treatment of high-risk anomalous aortic origin of coronary artery
Hujun CUI ; Jimei CHEN ; Shushui WANG ; Jianzheng CEN ; Gang XU ; Shusheng WEN ; Xiaobing LIU ; Jian ZHUANG
Chinese Journal of Surgery 2024;62(3):242-247
Objective:To analyze the diagnosis and surgical treatment of high-risk anomalous aortic origin of coronary artery (AAOCA).Methods:This is a retrospective case series study. From January 2016 to July 2023, 24 cases of high-risk AAOCA underwent surgical treatment in Department of Cardiac Surgery, Guangdong Provincial People's Hospital. There were 18 males and 6 females, operatively aged ( M (IQR)) 13 (26) years (range: 0.3 to 57.0 years). They were confirmed by cardiac ultrasound and cardiac CT, all of which had anomalous coronary running between the aorta and the pulmonary artery. There were 15 cases of the right coronary artery from the left aortic sinus of Valsalva, 6 cases of left coronary artery from the right aortic sinus of Valsalva, 3 cases of the sigle coronary artery. Only 3 patients had no obvious related symptoms (2 cases were complicated with a positive exercise stress test and 1 case with other intracardiac malformations), 21 cases had a history of chest tightness, chest pain, or syncope after exercise. Three patients suffered syncope after exercise and underwent cardiopulmonary resuscitation (2 cases were treated with an extracorporeal membrane oxygenerator (ECMO)). The gap from the first symptom to the diagnosis was 4.0 (11.5) months (range: 0.2 to 84.0 months). The detection rate of coronary artery abnormalities suggested by the first cardiac ultrasound was only 37.5% (9/24). Seven patients were complicated with other cardiac diseases (4 cases with congenital heart defects, 2 cases with coronary atherosclerotic heart disease, 1 case with mitral valve disease). Results:All 24 patients underwent surgical treatment (23 cases underwent abnormal coronary artery unroofing, 1 case underwent coronary artery bypass grafting), and 5 patients underwent other intracardiac malformation correction at the same time. There were no death or surgery related complications in the hospital for 30 days after the operation. A patient with preoperative extracorporeal cardiopulmonary resuscitation was continuously assisted by ECMO after emergency AAOCA correction and had complications such as limb ischemia necrosis and renal dysfunction after the operation. During the follow-up of 2.2 (3.3) years (range: 1 month to 7.2 years), one patient who previously underwent percutaneous transluminal coronary angioplasty with a stent implant experienced significant postoperative symptomatic relief, and the other discharged patients had no related symptoms.Conclusions:The accurate rate of initial diagnosis for high-risk AAOCA is still low, but the risk of cardiovascular accidents is high. For sports-related chest pain and other symptoms, more attention should be paid to the detection of AAOCA, especially for adolescents. Exercise stress testing can be helpful in evaluating the cardiovascular risk of asymptomatic AAOCA. Instant surgical treatment can achieve satisfactory curative effects.
5.Efficient genome editing in medaka (Oryzias latipes) using a codon-optimized SaCas9 system.
Yuewen JIANG ; Qihua PAN ; Zhi WANG ; Ke LU ; Bilin XIA ; Tiansheng CHEN
Journal of Zhejiang University. Science. B 2024;25(12):1083-1096
The clustered regularly interspaced short palindromic repeats (CRISPR)/CRISPR-associated protein 9 (Cas9) system, belonging to the type II CRISPR/Cas system, is an effective gene-editing tool widely used in different organisms, but the size of Streptococcus pyogenes Cas9 (SpCas9) is quite large (4.3 kb), which is not convenient for vector delivery. In this study, we used a codon-optimized Staphylococcus aureus Cas9 (SaCas9) system to edit the tyrosinase (tyr), oculocutaneous albinism II (oca2), and paired box 6.1 (pax6.1) genes in the fish model medaka(Oryzias latipes), in which the size of SaCas9 (3.3 kb) is much smaller and the necessary protospacer-adjacent motif (PAM) sequence is 5'-NNGRRT-3'. We also used a transfer RNA (tRNA)-single-guide RNA (sgRNA) system to express the functional sgRNA by transcription eitherin vivo or in vitro, and the combination of SaCas9 and tRNA-sgRNA was used to edit the tyr gene in the medaka genome. The SaCas9/sgRNA and SaCas9/tRNA-sgRNA systems were shown to edit the medaka genome effectively, while the PAM sequence is an essential part for the efficiency of editing. Besides, tRNA can improve the flexibility of the system by enabling the sgRNA to be controlled by a common promoter such as cytomegalovirus. Moreover, the all-in-one cassette cytomegalovirus (CMV)-SaCas9-tRNA-sgRNA-tRNA is functional in medaka gene editing. Taken together, the codon-optimized SaCas9 system provides an alternative and smaller tool to edit the medaka genome and potentially other fish genomes.
Animals
;
Oryzias/genetics*
;
Gene Editing/methods*
;
CRISPR-Cas Systems
;
Codon
;
RNA, Guide, CRISPR-Cas Systems/genetics*
;
Monophenol Monooxygenase/genetics*
;
CRISPR-Associated Protein 9/genetics*
;
RNA, Transfer/genetics*
;
Staphylococcus aureus/genetics*
;
PAX6 Transcription Factor/genetics*
6.Can lung ultrasound replace the chest X-ray? A prospective multicenter study
Yangming QU ; Shuyu SI ; Huiqing SUN ; Pingyang CHEN ; Qianshen ZHANG ; Li MA ; Zhaoqing YIN ; Min XIAO ; Jimei WANG ; Xirong GAO ; Ling LIU ; Jinxing FENG ; Yanping ZHU ; Di JIN ; Jing ZHANG ; K. Shoo LEE ; Hui WU
Chinese Pediatric Emergency Medicine 2023;30(11):834-839
Objective:To analyze the accuracy of lung ultrasound and chest X-ray in the diagnosis of neonatal pulmonary disease.Methods:We prospectively collected newborns that needed chest X-ray examination to diagnose pulmonary disease from twelve neonatal intensive care units across the country between June 2019 and April 2020.Each newborn was examined by lung ultrasound within two hours after chest X-ray examination.All chest X-ray and lung ultrasound images were independently read by a radiologist and a sonographer.When there was a disagreement, a panel of two experienced physicians made a final diagnosis based on the clinical history, chest X-ray and lung ultrasound images.Results:A total of 1 100 newborns were enrolled in our study.The diagnostic agreement between chest X-ray and lung ultrasound(Cohen′s kappa coefficient=0.347) was fair.Lung ultrasound(area under the curve=0.778; 95% CI 0.753-0.803) performed significantly better than chest X-ray(area under the curve=0.513; 95% CI 0.483-0.543) in the diagnosis of transient tachypnea of the newborn( P<0.001). The accuracy of lung ultrasound in diagnosing neonatal respiratory distress syndrome, meconium aspiration syndrome, pneumonia and neonatal pulmonary atelectasis was similar to that of chest X-ray. Conclusion:Lung ultrasound, as a low-cost, simple and radiation-free auxiliary examination method, has a diagnostic accuracy close to or even better than that of chest X-ray, which may replace chest X-ray in the diagnosis of some neonatal lung diseases.It should be noted that both chest X-ray and lung ultrasound can only be used as auxiliary means for the diagnosis of lung diseases, and it is necessary to combine imaging with the clinical history and presentation.
7.Advance in perinatal management of fetuses with abnormal cardiac physiological shunts
Chinese Journal of Perinatal Medicine 2023;26(10):872-877
Prior to birth, fetal pulmonary vessels are constricted and fetal lungs and liver are not fully functional. Ductus arteriosus, foramen ovale, and ductus venosus, which are unique cardiovascular structures of fetuses, constitute a parallel circulatory system. A comprehensive understanding of the outcomes of fetuses with abnormal cardiac physiological shunts and improving perinatal management are of great significance in reducing the risk of fetal and neonatal mortality. This review primarily describes the etiology, pathophysiology, treatment strategies, and prognosis of abnormal cardiac physiological shunts in fetuses.
8.Congenital alveolar synechiae with cleft palate: A case report
Zijun WANG ; Jingjing CHEN ; Jimei SU
STOMATOLOGY 2023;43(3):248-251
An oral synechia is a fibrous or soft tissue adhesion between the maxilla and the mandible. These synechiae can appear at various locations in the oral cavity, with alveolar synechia being one of the manifestations. Alveolar synechia is a rare congenital deformity and often accompanied by additional congenital defects, such as cleft lip or palate, microglossia, micrognathia, or TMJ anomalies. Among these, cleft palate is the most common. A case of congenital alveolar synechiae with cleft palate is reported. The child is in good condition after surgical treatment. The etiology and treatment are discussed.
9.Expert consensus on the use of human serum albumin in adult cardiac surgery.
Fei XIANG ; Fuhua HUANG ; Jiapeng HUANG ; Xin LI ; Nianguo DONG ; Yingbin XIAO ; Qiang ZHAO ; Liqiong XIAO ; Haitao ZHANG ; Cui ZHANG ; Zhaoyun CHENG ; Liangwan CHEN ; Jimei CHEN ; Huishan WANG ; Yingqiang GUO ; Nan LIU ; Zhe LUO ; Xiaotong HOU ; Bingyang JI ; Rong ZHAO ; Zhenxiao JIN ; Robert SAVAGE ; Yang ZHAO ; Zhe ZHENG ; Xin CHEN
Chinese Medical Journal 2023;136(10):1135-1143
10.Preliminary clinical outcomes of the domestic Renatus® balloon-expandable valve system for the treatment of severe aortic stenosis: A prospective cohort study
Tong TAN ; Hongxiang WU ; Bingqi FU ; Nianjin XIE ; Haijiang GUO ; Xin ZANG ; Xiaoyi LI ; Haozhong LIU ; Ruobing WANG ; Jian LIU ; Huanlei HUANG ; Jimei CHEN ; Jian ZHUANG ; Huiming GUO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2023;30(02):214-220
Objective To evaluate the early clinical outcomes of the Renatus® balloon-expandable valve in the treatment of severe aortic stenosis. Methods From November 2021 to April 2022, a total of 38 patients who received Renatus® balloon-expandable valve for severe aortic stenosis in Guangdong Provincial People's Hospital were included. There were 22 males and 16 females, with an average age of 73.7±5.3 years. Mean aortic gradient and peak aortic jet velocity at baseline, post-procedure, and follow-up were compared. Clinical outcomes including all-cause mortality, perivalvular leakage, serious adverse cardiovascular events and the occurrence of permanent pacemaker implantation were assessed. Results All patients completed the procedure successfully without conversion to thoracotomy or perioperative death. The post-implant mean aortic pressure gradient was decreased from 41.5 (27.8, 58.8) mm Hg to 6.0 (3.0, 8.0) mm Hg, and the peak aortic jet velocity was also decreased from 4.1±0.9 m/s to 1.7±0.4 m/s (P<0.001). Pacemakers were required in 2 (5.3%) patients. The median follow-up time was 27.5 (23.0, 87.5) d, with a follow-up rate of 100.0%. The mean aortic gradient was 8.0 (7.0, 10.8) mm Hg and peak aortic jet velocity was 2.0±0.3 m/s, showing significant improvement compared with those in the preoperative period (P<0.001). No severe aortic regurgitation or paravalvular leak was observed. There was no serious cardiovascular adverse event or reoperative event during the study period. Conclusion Transcatheter aortic valve replacement with the domestic Renatus® balloon-expandable valve system is a safe and effective procedure for selected patients with severe aortic stenosis who are at high risk or not candidates for surgical aortic valve replacement.