1.Expert consensus on the clinical application of domestic ultra-high-definition medical endoscopes in cardiovascular surgery (2026 edition)
Junfei ZHAO ; Biaochuan HE ; Yun TENG ; Xiaohua LI ; Zerui CHEN ; Chungeng LIU ; Yijiu REN ; Chang CHEN ; Nianguo DONG ; Jimei CHEN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(06):857-865
This consensus focuses on the clinical application of domestic ultra-high-definition (UHD) medical endoscopes in cardiovascular surgery, addressing their clinical value, key technical aspects, and strategies for broader implementation. It traces the evolution of domestic endoscopic platforms from high-resolution imaging toward integrated advanced functionalities such as fluorescence imaging, three-dimensional visualization, and intelligent assistance. The document outlines standardized procedural steps and perioperative management pathways for minimally invasive endoscopic cardiovascular surgery and summarizes specific application scenarios and technical considerations in congenital heart disease, valvular disorders, coronary artery disease, arrhythmias, and cardiac tumors. Furthermore, recommendations are provided regarding professional training, multicenter collaboration, the establishment of clinical evaluation systems, and coordinated policy-industry support to promote standardized adoption and high-quality dissemination of domestic medical devices. Based on available evidence and expert agreement, 16 consensus statements are presented, aiming to offer authoritative and actionable guidance for clinical practice.
2.A cone beam CT study on the changes in oropharyngeal airway parameters and hyoid position in skeletal Class Ⅱ adult female patients with different vertical skeletal types treated with maxillary anterior teeth retraction with maximum anchorage
SHEN Jiaoxiang ; CHEN Zhaozheng ; LIN Yihui ; SU Jingjing ; HUANG Wenxia
Journal of Prevention and Treatment for Stomatological Diseases 2025;33(6):491-501
Objective:
To investigate the changes in oropharyngeal airway parameters and hyoid position in skeletal ClassⅡ adult female patients with different vertical skeletal types who were treated with maxillary anterior teeth retraction with maximum anchorage, and to provide a reference for orthodontic clinical diagnosis and treatment.
Methods:
This study was reviewed and approved by the Medical Ethics Committee, and informed consent was obtained from patients. Sixty adult female patients with skeletal ClassⅡ were selected and divided into a skeletal ClassⅡ normodivergent group and a skeletal ClassⅡ hyperdivergent group based on the patients’ mandibular plane angle. In both groups, the bilateral maxillary first premolars were extracted and the maxillary anterior teeth were retracted with maximum anchorage. Cone beam CT(CBCT) images were collected before and after treatment, and three-dimensional measurement software was used to analyze oropharyngeal airway-related parameters.
Results:
After retraction of the maxillary anterior teeth with maximum anchorage, the 10 parameters related to the oropharyngeal airway did not exhibit statistically significant differences in the normodivergent group (P>0.05), but the perpendicular distance from the highest point of the hyoid bone to the vertical line passing through the sella (H-X) value decreased (P<0.001). In the hyperdivergent group, the oropharyngeal area at the level of the epiglottis tip (OPA-E), anterior-posterior diameters of the oropharynx at the level of the epiglottis tip (E-AP), most constricted axial area of the oropharynx (OPA-MCA), and anterior-posterior diameters of MCA area of the oropharynx (MCA-AP) decreased after treatment (P<0.001). In addition, the oropharyngeal volume (OPV) decreased after treatment (P<0.05), and the perpendicular distance from the highest point of the hyoid bone to the horizontal line passing through the sella (H-Y) and the highest point of the hyoid bone to the epiglottis base (H-Eb) values increased after treatment (P<0.05).
Conclusion
After retraction of the maxillary anterior teeth with maximum anchorage, there is no change in the oropharyngeal airway in skeletal ClassⅡ normodivergent female adult patients, while skeletal ClassⅡhyperdivergent female adult patients have a risk of reduction in the oropharyngeal airway after maximuim anchorage retraction of the maxillary anterior teeth.
3.Single-center experience in the treatment of severe aortic stenosis with XcorTM transcatheter aortic valve replacement system: 1-year follow-up results.
Shengwen WANG ; Haozhong LIU ; Haijiang GUO ; Tong TAN ; Hanxiang XIE ; Xiang LIU ; Hailong QIU ; Jimei CHEN ; Huiming GUO ; Jian LIU
Journal of Zhejiang University. Medical sciences 2025;54(2):141-148
OBJECTIVES:
To analyze the early clinical outcomes of the XcorTM transcatheter aortic valve replacement (TAVR) system in treating severe aortic stenosis. This study has been registered at Chinese Clinical Trial Registry (ChiCTR2200065593).
METHODS:
This single-arm, prospective clinical trial enrolled patients with severe aortic stenosis treated with the XcorTM TAVR system at the Section of Heart Valve & Coronary Artery Surgery, Guangdong Provincial People's Hospital. Perioperative and follow-up parameters were compared to evaluate differences in hemodynamic outcomes. All-cause mortality, aortic regurgitation, paravalvular leakage, cerebrovascular events, and reoperation were analyzed.
RESULTS:
Thirty-two patients with severe aortic stenosis were included (20 males, 12 females), with (70.9±4.3) years old and a Society of Thoracic Surgeons (STS) score of 6.45% (6.07%, 7.28%). Notably, 87.5% of patients had New York Heart Association (NYHA) class≥Ⅲ. All patients underwent successful XcorTM bioprosthesis implantation, achieving an immediate technical success rate of 100.0% and device success rate of 96.9%. Mean aortic valve gradient decreased from (55.21±23.17) mmHg (1 mmHg=0.133 kPa) to (8.45±5.30) mmHg, peak aortic jet velocity decreased from (4.66±0.85) m/s to (1.99±0.48) m/s, aortic valve area increased from (0.66±0.21) cm² to (2.09±0.67) cm² (all P<0.01). Intraoperative ventricular fibrillation occurred in one patient, while one case exhibited moderate prosthetic valve regurgitation and paravalvular leakage post-procedure. At 12-month follow-up, sustained improvements were observed in cardiac function, left ventricular ejection fraction, hemodynamic parameters, and SF-12 quality-of-life scores (all P<0.01). All-cause mortality was 12.5% (4/32), with 13.8% (4/29) developing moderate paravalvular leakage.
CONCLUSIONS
The XcorTM TAVR system demonstrated favorable early outcomes in severe aortic stenosis patients, significantly improving symptoms and hemodynamics while exhibiting excellent performance in preventing malignant arrhythmias and coronary obstruction.
Humans
;
Male
;
Female
;
Aortic Valve Stenosis/surgery*
;
Transcatheter Aortic Valve Replacement/methods*
;
Aged
;
Follow-Up Studies
;
Prospective Studies
;
Treatment Outcome
;
Aged, 80 and over
;
Heart Valve Prosthesis
;
Middle Aged
4.Early results of modified double-orifice valve plasty via total thoracoscopy for partial atrioventricular septal defect
Hailong QIU ; Tianyu CHEN ; Zewen CHEN ; Zhanhao SU ; Miao TIAN ; Zhao CHEN ; Hongkun QING ; Shusheng WEN ; Jianzheng CEN ; Jimei CHEN ; Xiaohua LI
Chinese Journal of Thoracic and Cardiovascular Surgery 2025;41(6):328-333
Objective:To evaluate the safety, efficacy, advantages and disadvantages of the modified double-orifice valve plasty via total thoracoscopy for partial atrioventricular septal defect(PAVSD) through a retrospective analysis of early postoperative results.Methods:Patients diagnosed with PAVSD who underwent the standardized modified double-orifice valve plasty via total thoracoscopy between September 2023 and August 2024 were retrospectively enrolled. Baseline characteristics, surgical parameters, and follow-up outcomes were systematically analyzed.Results:A total of 14 patients(6 males, 8 females) were included, with a mean age of(32.9±15.5) years old and body weight of(55.1±11.6) kg. All procedures were successfully completed. The mean operative time, cardiopulmonary bypass time, and aortic cross-clamp time were(266.6±67.2) min, (160.7±34.2) min, and(97.0±31.1) min, respectively. Postoperative ICU stay, hospital stay, and total hospitalization duration were(1.7±1.1) days, (6.4±4.2) days, and(12.6±4.5) days, respectively. The mean follow-up duration was(7.9±3.6) months. Preoperatively, left atrioventricular valve regurgitation(LAVVR) was graded as mild, moderate, or severe in 5, 4, and 5 patients. Postoperatively, 13 patients exhibited mild or less LAVVR, with 1 case of moderate regurgitation. By 3 months, all patients demonstrated LAVVR of mild or lower severity, which remained stable through follow-up. Peak LAVV gradients were(4.6±2.7) mmHg(1 mmHg=0.133 kPa)(range: 1.8-10.2 mmHg) postoperatively, improving to(3.6±0.6) mmHg(3.2-4.0) mmHg at 1 year. Right atrioventricular valve regurgitation improved from preoperative moderate-severe(50.0%) to LAVVR of mild or lower severity in all patients by 3 months. No mortality, residual shunts, or high-grade atrioventricular block occurred through follow-up. By 1 month, NYHA functional class improved to Ⅰ in all patients, which remained stable through follow-up.Conclusion:Standardized modified double-orifice valve plasty via total thoracoscopy for PAVSD demonstrates safety, minimal invasiveness, and rapid recovery, with favorable early outcomes.
5.Establishment and evaluation of a new large animal model for fetal cardiopulmonary bypass
Kaiyu WANG ; Qingqing MENG ; Dasheng NING ; Chunfeng ZHU ; Jinjin YU ; Jimei CHEN ; Jian ZHUANG ; Haiyun YUAN
Chinese Journal of Thoracic and Cardiovascular Surgery 2025;41(10):599-605
Objective:In order to reduce the trauma associated with fetal cardiopulmonary bypass(F-CPB), Our team plans to develop a minimally invasive F-CPB through a small incision in the right axilla. The efficacy of this technique will be verified by using a big experimental animal model, thereby laying the foundation for fetal cardiac surgery supported by F-CPB in the future.Methods:Ten pregnant sheep were divided into F-CPB group(n=5) and control group(n=5). After fasting for 24 h, fetal lambs in the F-CPB group underwent a right axillary incision to establish F-CPB running for 1 h; The control group of fetal lambs only expose heart 1 h without F-CPB. Collect blood sample for laboratory test at the CPB vehicle before(T0), 30 min(T1), and 1 h after F-CPB running(T2) for the F-CPB group and through Superior Vena Cava before(T0), 30 min(T1), and 1 h after F-CPB running(T2) for the control group.Results:The blood routine indicators such as RBC, HCT, and Hb in the F-CPB group of fetal lambs decreased significantly during F-CPB, and their distribution showed significant statistical differences compared with the control group( P<0.05). There were no significant statistical differences in blood gas indicators such as pH, PO 2, PCO 2, and lactate concentration between the F-CPB group and the control group( P>0.05). There was no statistically significant difference in the concentration of cTnI in fetal lamb serum at each time point( P>0.05). There were significant statistical differences( P<0.05) in the distribution of fetal lamb Alb, γ-GGT, CK concentration and cholesterol concentration at various time points in the F-CPB group compared with the control group in liver function examination. In addition, the distribution of BUN in fetal lambs showed a significant difference between the two groups( P=0.006). Conclusion:A minimally invasive F-CPB via small incision in the right axilla is safe and feasible. The experimental animal model has demonstrated that this technique has minimal impact on the vital organ functions and internal environment of fetal lambs, thereby laying the foundation for clinical fetal cardiac surgery in the future.
6.Clinical and epidemiological characteristics of 12 patients tested with Candida auris
Hongfang ZHANG ; Jimei HU ; Mingxia CHEN ; Li YAN ; Qingfang KONG
Chinese Journal of Nosocomiology 2025;35(9):1417-1422
OBJECTIVE To analyze the clinical characteristics of the 12 patients tested with Candida auris in a three-A hospital so as to provide guidance for prevention and control of nosocomial C.auris infection.METHODS The specimens sources and departments where the C.auris strains were isolated as well as the drug resistance were retrospectively collected from Zhongda Hospital Affiliated to Southeast University between Sep.2023 and Jun.2024.The clinical characteristics of the patients with C.auris infection were summarized.The epidemiological survey was conducted for the possibility of its transmission in hospitals,and the corresponding modified preven-tion measures were put forward.RESULTS Among the 12 patients who were tested with C.auris,10 were male,and 2 were female;the age ranged between 21 and 92 years old.Most of the patients were complicated with multi-ple underlying diseases and had the history of repeated hospitalization as well as the history of invasive operation procedures such as tracheotomy,urinary catheterization,gastric tube indwelling and venoarterial catheterization;in the meantime,other multidrug-resistant organisms(MDROs)and fungi were tested in those patients,and the patients used multiple types of antibiotics.Totally 16 strains of C.auris were isolated from the 12 patients with C.auris tested,62.50%(10/16)of which were isolated from urine specimens,18.75%(3/16)were isolated from sputum specimens,and 6.25%(1/16)were isolated from deep venous catheter,tissue biopsy and wound swab specimens.All of the 16 strains of C.auris were resistant to fluconazole and sensitive to caspofungin;4 strains were resistant to amphotericin B.Totally 2 patients had Candida auris infection,one was pulmonary infection,and the other was urinary tract infection,and the infection rate was 16.67%;both patients were cured.There were 10 cases of colonization,and the colonization rate was 83.33%.The result of epidemiological survey indicated that the C.auris that was tested in the No.8 patient may originate from the No.4 patient who carelessly brought from outside the hospital due to poor implementation of standardized prevention measures.CONCLUSIONS The patients tested with C.auris usually have complicated medical backgrounds.Although the colonized C.auris strains are dominant among the strains in the hospital,the related departments need to intensify the implementation of pre-vention measures so as to prevent the transmission of C.auris and pay special attention to the early identification and management of imported pathogens.
7.Clinical and epidemiological characteristics of 12 patients tested with Candida auris
Hongfang ZHANG ; Jimei HU ; Mingxia CHEN ; Li YAN ; Qingfang KONG
Chinese Journal of Nosocomiology 2025;35(9):1417-1422
OBJECTIVE To analyze the clinical characteristics of the 12 patients tested with Candida auris in a three-A hospital so as to provide guidance for prevention and control of nosocomial C.auris infection.METHODS The specimens sources and departments where the C.auris strains were isolated as well as the drug resistance were retrospectively collected from Zhongda Hospital Affiliated to Southeast University between Sep.2023 and Jun.2024.The clinical characteristics of the patients with C.auris infection were summarized.The epidemiological survey was conducted for the possibility of its transmission in hospitals,and the corresponding modified preven-tion measures were put forward.RESULTS Among the 12 patients who were tested with C.auris,10 were male,and 2 were female;the age ranged between 21 and 92 years old.Most of the patients were complicated with multi-ple underlying diseases and had the history of repeated hospitalization as well as the history of invasive operation procedures such as tracheotomy,urinary catheterization,gastric tube indwelling and venoarterial catheterization;in the meantime,other multidrug-resistant organisms(MDROs)and fungi were tested in those patients,and the patients used multiple types of antibiotics.Totally 16 strains of C.auris were isolated from the 12 patients with C.auris tested,62.50%(10/16)of which were isolated from urine specimens,18.75%(3/16)were isolated from sputum specimens,and 6.25%(1/16)were isolated from deep venous catheter,tissue biopsy and wound swab specimens.All of the 16 strains of C.auris were resistant to fluconazole and sensitive to caspofungin;4 strains were resistant to amphotericin B.Totally 2 patients had Candida auris infection,one was pulmonary infection,and the other was urinary tract infection,and the infection rate was 16.67%;both patients were cured.There were 10 cases of colonization,and the colonization rate was 83.33%.The result of epidemiological survey indicated that the C.auris that was tested in the No.8 patient may originate from the No.4 patient who carelessly brought from outside the hospital due to poor implementation of standardized prevention measures.CONCLUSIONS The patients tested with C.auris usually have complicated medical backgrounds.Although the colonized C.auris strains are dominant among the strains in the hospital,the related departments need to intensify the implementation of pre-vention measures so as to prevent the transmission of C.auris and pay special attention to the early identification and management of imported pathogens.
8.Advances in prenatal interventional treatment for fetal congenital heart disease
Luoming HU ; Haiyun YUAN ; Jimei CHEN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(07):1022-1028
This review provides an overview of prenatal interventional treatments for fetal congenital heart disease (CHD), with a particular focus on the latest advancements in fetal aortic valvuloplasty (FAV) and fetal pulmonary valvuloplasty (FPV). FAV aims to improve left heart hemodynamics, prevent hypoplastic left heart syndrome (HLHS), and promote biventricular circulation. FPV seeks to improve the natural history of pulmonary atresia with intact ventricular septum (PA/IVS) and critical pulmonary stenosis with intact ventricular septum (CPS/IVS), alleviate right ventricular outflow tract obstruction, and promote biventricular circulation. This article discusses patient selection, technical details, risk assessment, and clinical outcomes for these procedures, highlighting the challenges in current research, including the lack of standardized patient selection criteria and long-term prognostic studies. Additionally, it emphasizes the opportunities and challenges of fetal cardiac intervention (FCI) development in China and proposes recommendations for future improvements and research directions.
9.Application of bicuspid pulmonary valve sewn by 0.1 mm expanded polytetrafluoroethylene in right ventricle outflow tract reconstruction
Jianrui MA ; Tong TAN ; Miao TIAN ; Jiazichao TU ; Wen XIE ; Hailong QIU ; Shuai ZHANG ; Jian ZHUANG ; Jimei CHEN ; Jianzheng CEN ; Shusheng WEN ; Haiyun YUAN ; Xiaobing LIU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(08):1127-1132
Objective To introduce a modified technique of right ventricular outflow tract (RVOT) reconstruction using a handmade bicuspid pulmonary valve crafted from expanded polytetrafluoroethylene (ePTFE) and to summarize the early single-center experience. Methods Patients with complex congenital heart diseases (CHD) who underwent RVOT reconstruction with a handmade ePTFE bicuspid pulmonary valve due to pulmonary regurgitation at Guangdong Provincial People’s Hospital from April 2021 to February 2022 were selected. Postoperative artificial valve function and right heart function indicators were evaluated. Results A total of 17 patients were included, comprising 10 males and 7 females, with a mean age of (18.18±12.14) years and a mean body weight of (40.94±19.45) kg. Sixteen patients underwent reconstruction with a handmade valved conduit, with conduit sizes ranging from 18 to 24 mm. No patients required mechanical circulatory support, and no in-hospital deaths occurred. During a mean follow-up period of 12.89 months, only one patient developed valve dysfunction, and no related complications or adverse events were observed. The degree of pulmonary regurgitation was significantly improved post-RVOT reconstruction and during follow-up compared to preoperative levels (P<0.001). Postoperative right atrial diameter, right ventricular diameter, and tricuspid regurgitation area were all significantly reduced compared to preoperative values (P<0.05). Conclusion The use of a 0.1 mm ePTFE handmade bicuspid pulmonary valve for RVOT reconstruction in complex CHD is a feasible, effective, and safe technique.
10.Screening and characterization of camelid-derived nanobodies against hemoglobin.
Ning ZHONG ; Wenhui LEI ; Zuying LIU ; Xiaoxiao XIE ; Lingjing ZHANG ; Tengchuan JIN ; Minjie CAO ; Yulei CHEN
Chinese Journal of Biotechnology 2025;41(4):1515-1534
Hemoglobin, the principal protein in red blood cells, is crucial for oxygen transport in the bloodstream. The quantification of hemoglobin concentration is indispensable in medical diagnostics and health management, which encompass the diagnosis of anemia and the screening of various blood disorders. Immunological methods, based on antigen-antibody interactions, are distinguished by their high sensitivity and accuracy. Consequently, it is necessary to develop hemoglobin-specific antibodies characterized by high specificity and affinity to enhance detection accuracy. In this study, we immunized a Bactrian camel (Camelus bactrianus) with human hemoglobin and subsequently constructed a nanobody library. Utilizing a solid-phase screening method, we selected nanobodies and evaluated the binding activity of the screened nanobodies to hemoglobin. Initially, human hemoglobin was used to immunize a Bactrian camel. Following four immunization sessions, blood was withdrawn from the jugular vein, and a nanobody library with a capacity of 2.85×108 colony forming units (CFU) was generated. Subsequently, ten hemoglobin-specific nanobody sequences were identified through three rounds of adsorption-elution-enrichment assays, and these nanobodies were subjected to eukaryotic expression. Finally, enzyme-linked immunosorbent assay and biolayer interferometry were employed to evaluate the stability, binding activity, and specificity of these nanobodies. The results demonstrated that the nanobodies maintained robust binding activity within the temperature range of 20-40 ℃ and exhibited the highest binding activity at pH 7.0. Furthermore, the nanobodies were capable of tolerating a 10% methanol solution. Notably, among the nanobodies tested, VHH-12 displayed the highest binding activity to hemoglobin, with a half maximal effective concentration (EC50) of 10.63 nmol/L and a equilibrium dissociation constant (KD) of 2.94×10-7 mol/L. VHH-12 exhibited no cross-reactivity with a panel of eight proteins, such as ovalbumin and bovine serum albumin, while demonstrating partial cross-reactivity with hemoglobin derived from porcine, goat, rabbit, and bovine sources. In this study, a hemoglobin-specific high-affinity nanobody was successfully isolated, demonstrating potential applications in disease diagnosis and health monitoring.
Animals
;
Camelus/immunology*
;
Single-Domain Antibodies/immunology*
;
Hemoglobins/immunology*
;
Humans
;
Peptide Library


Result Analysis
Print
Save
E-mail