1.Epidemiological survey of osteoporosis in Beijing over the past decade: a single-center analysis of dual-energy X-ray absorptiometry scans from 30 599 individuals.
Ying ZHOU ; Danyang ZHANG ; Lifan WU ; Guishan WANG ; Jiedan MU ; Chengwen CUI ; Xiuxiu SHI ; Jige DONG ; Yu WANG ; Wangli XU ; Xiao LI
Journal of Southern Medical University 2025;45(3):443-452
OBJECTIVES:
To analyze bone mass distribution and the factors affecting bone mass in a general Chinese Han cohort undergoing physical examinations at our center.
METHODS:
We retrospectively collected the data of bone mineral density (BMD) measurements from 30 599 healthy Han Chinese adults (age≥20 years) who underwent dual-energy X-ray absorptiometry scans at our hospital from July, 2013 to July, 2023. Basic parameters including height, body weight, and gender were recorded, and descriptive statistics and correlation analyses were performed using R software.
RESULTS:
In this cohort, the male individuals had a mean peak BMD of 1.00±0.12 g/cm2 in the lumbar vertebrae, 0.94±0.14 g/cm2 in the femoral neck, and 0.99±0.13 g/cm2 in the total hip, significantly higher than the values in the female individuals [0.99±0.12 g/cm2 in the lumbar vertebrae (P=0.022), 0.79±0.11 g/cm2 in the femoral neck (P<0.001), and 0.88±0.11 g/cm2 in the total hip (P<0.001)]. In the overall cohort, the BMD values of the lumbar spine and femur decreased with age after reaching their peak levels. There was a positive correlation between BMD value and body mass index (BMI) in both male and female individuals. The 2013-2014 period recorded the lowest BMD values in the lumbar, hip, and femoral neck, which tended to increase steadily in the following years (2015-2023).
CONCLUSIONS
Our data suggest that the BMD values vary among different populations, and future multi-center studies using more accurate BMD detection technology are warranted to capture the variation patterns of BMD with demographic characteristics of specific populations.
Humans
;
Bone Density
;
Absorptiometry, Photon
;
Male
;
Female
;
Retrospective Studies
;
Osteoporosis/diagnostic imaging*
;
Adult
;
Middle Aged
;
Lumbar Vertebrae/diagnostic imaging*
;
China/epidemiology*
;
Femur Neck/diagnostic imaging*
;
Aged
;
Beijing/epidemiology*
;
Young Adult
2.Construction of Electrochemical Sensor Based on Praseodymium Hexacyanoferrate Modified Graphite Electrode and Its Application for Cysteine Determination
Yuanwen ZHONG ; Mouhong LIN ; Jiedan ZHOU ; Yingju LIU
Chinese Journal of Analytical Chemistry 2010;38(2):229-232
Praseodymium hexacyanoferrate film was modified on the graphite electrode by cyclic voltammetry in the solution of PrCl_3 and K_3Fe(CN)_6. Its electrochemical properties, including the influence of different scan rates, ions, and K~+ concentrations on the film, were studied. The membrane was characterized by IR and XPS. In IR spectrum, the vibration of cyano group verified from the formation of the film on the electrode. In XPS spectrum, the splitting of Fe2p_(1/2) )and Fe2p_(3/2)) showed that the valence of iron has been changed in the film formation, and a proper electropolymerization mechanism was put forward. The results showed the PrHCF film have some electrocatalytic activity to the oxidation of cysteine. The detection conditions for cysteine such as the potential and pH were also discussed.

Result Analysis
Print
Save
E-mail