1.Analysis of the application status of prescription pre-review systems in Yunnan province
Fan XU ; Wenjie YIN ; Kejia LI ; Zhengfu LI ; Jie CHEN ; Meixian WU ; Ruixiang CHEN ; Songmei LI ; Guowen ZHANG ; Te LI
China Pharmacy 2026;37(1):6-10
OBJECTIVE To investigate the application status of prescription pre-review systems in healthcare institutions of Yunnan province, evaluate their system functions and management capabilities, and provide a practical basis for promoting rational drug use. METHODS A questionnaire survey was conducted among public healthcare institutions at or above the secondary level in Yunnan province to investigate the deployment status of the systems. A capability maturity assessment framework was constructed, encompassing 6 dimensions and 39 indicators, including real-time prescription review, prescription correlation review, rule setting, evidence-based information support, prescription authority management, and system operation management. This framework was then used to evaluate the institutions that had implemented the pre-review systems. RESULTS A total of 100 valid questionnaires were collected, with 37 institutions having adopted prescription pre-review systems, mainly tertiary hospitals. The system predominantly adopted a modular architecture and was embedded into the hospital information system through application programming interfaces and middleware, providing certain capabilities for real-time prescription risk identification. Evaluation results indicated that basic functions such as reviewing indications, contraindications, and drug compatibility performed well, while deficiencies remained in functions related to parenteral nutrition prescription, review of drug dosage for specific diseases, individual patient characteristic recognition, and rule setting. Moreover, the construction of review centers and establishment of management systems were also not well-developed. CONCLUSIONS The overall application rate of prescription pre-review systems in Yunnan province remains low. System functions and management mechanisms require further improvement. It is recommended to enhance information infrastructure in lower-level institutions and explore regionally unified review models to promote standardized and intelligent development of prescription review practices.
2.Effects and molecular mechanisms of Abelmoschi Corolla and its active flavonoids in the treatment of diabetic nephropathy
Journal of China Pharmaceutical University 2026;57(1):115-121
Abelmoschi Corolla is extensively applied in managing diabetic nephropathy (DN) and other renal conditions due to its diuretic and detoxifying properties. The primary bioactive constituents of Abelmoschi Corolla are flavonoids, including notably rutin, hyperoside, isoquercitrin, hibifolin, myricetin, quercetin 3-O-β-D-glucuronide, and quercetin. These flavonoid components can influence the pathological progression of DN via a multi-target synergistic mechanism, effectively reducing proteinuria levels. This review examines the roles of Abelmoschi Corolla and its flavonoid components in modulating the key pathological aspects of DN and their underlying mechanisms, and briefly discusses the metabolic patterns of its bioactive components and the research progress in combined medication, aiming to provide a forward-looking scientific foundation for further investigating the molecular mechanisms and clinical applications of Abelmoschi Corolla in DN treatment.
3.Effect of sitravatinib on a mouse model of carbon tetrachloride-induced liver fibrosis and its mechanism
Huan ZHANG ; Xiangyu WU ; Qianwen ZHAO ; Fajuan RUI ; Nan GENG ; Rui JIN ; Jie LI
Journal of Clinical Hepatology 2026;42(3):600-607
ObjectiveTo investigate the therapeutic effect of sitravatinib on carbon tetrachloride (CCl4)-induced liver fibrosis in mice. MethodsA total of 30 male C57BL/6J mice, aged 8 weeks, were randomly divided into control group, CCl4 model group, and low- (5 mg/kg), middle- (10 mg/kg), and high-dose (20 mg/kg) sitravatinib groups. All mice except those in the control group were given intraperitoneal injection of CCl4 for 4 consecutive weeks to induce liver fibrosis, and since the first day of modeling, the mice in the low-, middle-, and high-dose sitravatinib groups were given sitravatinib at the corresponding dose by gavage every day. The serum levels of total cholesterol (TC), triglyceride (TG), and alanine aminotransferase (ALT) were measured for the mice in each group; hepatic hydroxyproline content was measured; HE staining, Masson staining, and Sirius Red staining were used to observe liver histopathological changes; quantitative real-time PCR and Western blot were used to measure the mRNA and protein expression levels of α-smooth muscle actin (α-SMA) and collagen type I alpha 1 (Col1a1) in liver tissue. The therapeutic effect of sitravatinib was assessed based on the above results. A one-way analysis of variance was used for comparison of continuous data between multiple groups, and the least significant difference t-test was used for further comparison between two groups. ResultsCompared with the control group, the model group had significant increases in the levels of TC, TG, and ALT (all P<0.05), and there were no significant differences in the levels of TC, TG, and ALT between the model group and the low-, middle-, and high-dose sitravatinib groups (all P>0.05). Hepatic hydroxyproline content decreased after sitravatinib intervention, with a significant difference between the middle-/high-dose sitravatinib groups and the CCl4 model group (both P<0.05). Histopathological staining showed that the sitravatinib treatment groups had a reduction in collagen deposition, along with thinning and fragmentation of fibrous septa, and in the high-dose sitravatinib group, 4 mice had a fibrosis stage of S0—S1 and 2 mice had a fibrosis stage of S2—S3, suggesting a certain degree of alleviation of liver fibrosis degree compared with the CCl4 model group (mainly S3—S4). The measurement of related molecules showed that sitravatinib downregulated the mRNA and protein expression levels of α-SMA and Col1a1 (all P<0.05). ConclusionSitravatinib can effectively alleviate CCl4-induced liver fibrosis in mice, possibly by inhibiting hepatic stellate cell activation and collagen synthesis.
4.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
5.Association Between MTHFR C677T Gene Polymorphism and Hypertension, Hyperhomocysteinemia and Hyperlipidemia in Tibet Region
Pengchang LI ; Danni MU ; Zhijuan LIU ; Xiaoxing LIU ; Puchi ZEJI ; Liping TIAN ; Honglei LI ; Li'an HOU ; Dandan LI ; Jie WU ; Ling QIU
Medical Journal of Peking Union Medical College Hospital 2026;17(1):280-285
To explore the correlation between MTHFR C677T gene polymorphism and hypertension, hyperhomocysteinemia(Hcy), and hyperlipidemia in the Tibetan population of Tibet. Using a cluster sampling method, participants from high-altitude regions including Ngari Prefecture, Lhasa City, and Nyingchi City in Tibet were enrolled. Differences in MTHFR C677T genotype distribution among individuals with hypertension, HHcy, and hyperlipidemia were analyzed, and multivariate logistic regression was performed to assess the association between these conditions and the TT genotype. A total of 574 eligible subjects were included, with a mean age of 40.64±12.67 years. Males accounted for 46.7%(268/574) and females 53.3%(306/574). Regional distribution was 34.8%(200/574) from Nyingchi City, 33.1%(190/574) from Lhasa City, and 32.1%(184/574) from Ngari Prefecture. Mean systolic and diastolic blood pressures were 117.89±18.98 mm Hg and 79.74±14.88 mm Hg, respectively. The frequency of the TT genotype was significantly higher in the hypertension group than in the non-hypertension group(12.32% The MTHFR C677T TT genotype is significantly associated with hypertension and hyperhomocysteinemia in the Tibetan population, suggesting that this polymorphism may be a genetic risk factor for these diseases in high-altitude regions.
6.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
7.Investigation of an outbreak of group A human G9P [8] rotavirus infectious diarrhea among adults in Chongqing
Yang WANG ; Yuan KONG ; Ning CHEN ; Lundi YANG ; Jiang LONG ; Qin LI ; Xiaoyang XU ; Wei ZHENG ; Hong WEI ; Jie LU ; Quanjie XIAO ; Yingying BA ; Wenxi WU ; Qian XU ; Ju YAN
Shanghai Journal of Preventive Medicine 2025;37(8):663-668
ObjectiveTo investigate and analyze an outbreak of rotavirus infectious diarrhea in a prison in Chongqing Municipality, to provide a basis for adult rotavirus surveillance and prevention, and to explore the public health problems in special settings. MethodsA retrospective survey was conducted to collect and analyze data on individual cases with diarrheal disease on-site. The clinical characteristics, as well as the temporal, spatial and geographical distribution patterns of the epidemic were described. Multi-pathogen detection tests were conducted both on diarrhea cases and environmental samples, with viral genotyping performed on positive samples. A case-control analysis was performed to identify the causes of the outbreak, and an SEIR model was adopted to predict the outbreak trend and evaluate the effectiveness of interventions. ResultsA total of 65 cases were found among the inmates, with an attack rate of 2.03%. The predominant clinical manifestations included diarrhea (89.23%), watery stool (73.85%), and dehydration (18.46%). The epidemic curve indicated a “human-to-human” transmission pattern, with an average incubation period of 5‒6 days. The attack rates among chefs in the main canteen (80.00%, 8/10) and caterers (28.33%, 17/60) were significantly higher than those of other inmates (P<0.05). Multi-pathogen polymerase chain reaction (PCR) testing detected positive for group A rotavirus, with the viral genotyping identified as G9P [8] strain. Factors such as unprotected "bare-handed" food distribution among cases with diarrhea (OR=9.512, 95%CI: 4.261‒21.234) and close contact with diarrhea cases (OR=3.656, 95%CI: 1.719‒7.778) were the possible cause of the outbreak. The SEIR model (r0=5, α=0.3, β1=0.08, β2=0.04) was constructed using prison inmates as susceptible population, aiming at fitting the initial transmission trend of the outbreak, and the epidemic rate declined rapidly after intervention measures were implemented (rt≈0). ConclusionThis rare rotavirus infection diarrhea outbreak among adults in confined settings suggests that the construction of public health prevention and control systems in prison may be overlooked. Cross infection during meal processing and distribution in the canteens of such settings is likely to be the cause of the outbreak. Given the potential neglect of public heath system construction in special settings, it is imperative to enhance the surveillance and monitoring of rotavirus and other intestinal multi-pathogens among adults, as well as the construction of public health prevention and control systems in these special settings.
8.The effectiveness and safety of a percutaneous controllable curved plasma radiofrequency ablation device of nucleus pulposus
Hao ZHOU ; Qianyi ZHANG ; Jiajie LU ; Tao WU ; Yituo CHEN ; Qichen ZHANG ; Xilei LI ; Haikang CAI ; Jie TANG
Chinese Journal of Clinical Medicine 2025;32(4):659-664
Objective To verify the safety and effectiveness of a new percutaneous controllable curved plasma radiofrequency instrument for nucleus pulposus ablation. Methods A new percutaneous controllable curved plasma radiofrequency instrument were designed (controllable curved group), and its ablation effect was compared with the currently used straight head non-bendable plasma ablation instrument (non-bendable group) on gross specimens. The ablation instrument was placed through the right intervertebral foramen, and continuous ablation on the same intervertebral disc was conducted for three times. The ablation range and trajectory were recorded, and the temperature changes in the front, back, left, and right of the ablation center during and 15 seconds after ablation were monitored by the inserted temperature probe. Results There were no difference in temperature changes in the front, back, right regions of the ablation center during and 15 seconds after ablation between the two groups. The temperature changes in the left region of the ablation center both during and 15 seconds after 3rd ablation were larger than those in the non-bendable group (P<0.01). Compared with the non-bendable group, the controllable curved group achieved angle control and larger single ablation area (2.282 5 mm² vs 1.135 8 mm², P<0.000 1). Conclusions This new percutaneous controllable curved plasma ablation instrument can achieve angle control and ablation on the side opposite to the puncture site, increase ablation volume, and is safe.
9.Trend in disease burden of lung cancer in cancer registration areas of Guizhou Province from 2017 to 2021
ZHOU Jie ; ZHANG Ji ; JI Wei ; REN Yujin ; WU Yanli ; LI Ling
Journal of Preventive Medicine 2025;37(10):985-990
Objective:
To investigate trends of incidence, mortality, and years of life lost (YLL) rate of lung cancer in cancer registration areas of Guizhou Province from 2017 to 2021, so as to provide references for formulating lung cancer prevention and control strategies and reducing the disease burden of lung cancer.
Methods:
The qualified lung cancer registration data from cancer registration areas of Guizhou Province from 2017 to 2021 were collected, the crude incidence and mortality of lung cancer were calculated by urban/rural areas, genders and ages. The standardized incidence and standardized mortality was calculated using the age structure of the standard population from the Fifth National Population Census in 2000. YLL was calculated using the standard life table from the Global Burden of Disease Study 2019. The disease burden of lung cancer was assessed using incidence, mortality, and YLL rate, and the trend in the disease burden of lung cancer from 2017 to 2021 was calculated using annual percent change (APC).
Results :
From 2017 to 2021, the crude incidence, standardized incidence, crude mortality, standardized mortality, YLL and YLL rate in Guizhou Province were 53.13/100 000, 37.58/100 000, 42.77/100 000, 29.44/100 000, 98.19 thousand person-years and 10.95‰, respectively. The standardized incidence and standardized mortality of lung cancer were higher in rural areas than in urban areas (39.45/100 000 vs. 34.23/100 000, 30.68/100 000 vs. 27.18/100 000). The standardized incidence and standardized mortality of lung cancer were higher in males than in females (49.34/100 000 vs. 26.47/100 000, 41.31/100 000 vs. 18.28/100 000). The crude incidence and crude mortality of lung cancer increased with age, peaking in the 80-<85 age group (360.84/100 000) and the ≥85 age group (414.85/100 000), respectively. From 2017 to 2021, the standardized incidence demonstrated downward trends in the total population, urban areas and males (APC=-6.590%, -5.829%, and -6.729%, all P<0.05). The standardized mortality demonstrated downward trends in urban areas and females (APC=-3.710% and -5.378%, both P<0.05). The YLL rate also showed downward trends in urban areas and females (APC=-3.957% and -3.631%, both P<0.05).
Conclusions
From 2017 to 2021, the overall disease burden of lung cancer in registration areas of Guizhou Province showed a decreasing trend. However, the disease burden remained relatively heavier in rural areas and males, with a relatively gradual change.
10.Assessment of the implementation of Radiation shielding requirements for radiotherapy room—Part 4: Radiotherapy room of 252Cf neutron afterloading (GBZ/T 201.4-2015)
Yuze YANG ; Hongfang WANG ; Haoxian YANG ; Quan WU ; Mingsheng LI ; Bala HARI ; Yongzhong MA ; Zechen FENG ; Bin BAI ; Jie GAO ; Wei ZHOU ; Weixu HUANG ; Zhengjie SHI ; Hezheng ZHAI
Chinese Journal of Radiological Health 2025;34(5):660-665
Objective To track and evaluate the implementation and application of the occupational health standard Radiation shielding requirements for radiotherapy room—Part 4: Radiotherapy room of 252Cf neutron afterloading (GBZ/T 201.4-2015) by radiation health technical service agencies, medical institutions, health supervision agencies, and radiotherapy facility design units, and to provide a scientific basis for the further revision and implementation of this standard. Methods Following the Guideline for health standards tracking evaluation (WS/T 536-2017) and the project implementation plan, relevant practitioners were randomly selected for a questionnaire survey. The survey primarily focused on their awareness, standard training, application, and revision suggestions of GBZ/T 201.4-2015. The results were summarized and analyzed. Results A total of 168 evaluation questionnaires were collected from relevant practitioners in 28 provinces. Only 31.6% of the respondents reported being “well familiar” or “ familiar” with the standard, 27.4% of the respondents believed that the standard was widely used, and 45.2% of the respondents believed that the standard could meet the needs of their work. Only 14.9% of the respondents had received relevant training on the standard, more than half of the respondents had not applied the standard within the past 10 years, and 45.2% of the respondents believed that the standard "needs to be revised". Conclusion Due to the small number of californium-252 neutron afterloading radiotherapy devices in operation on the market, the overall awareness of the standard is low, suggesting that relevant authorities need to strengthen training and publicity of the standard, and that certain sections of the standard need to be revised or merged.


Result Analysis
Print
Save
E-mail