1.Establishment and evaluation of a method for simultaneous analysis of fluconazole,linezolid,voriconazole and contezolid by liquid chromatography-tandem mass spectrometry
Jiexin LIU ; Lei CAO ; Yingfei PENG ; Jiaqian QIN ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Clinical Laboratory Science 2025;43(4):241-245
Objective To establish and validate a method for simultaneous analysis of fluconazole,linezolid,voriconazole and cont-ezolid by liquid chromatography-tandem mass spectrometry,and conduct preliminary assessment its value of application value in clinical therapeutic drug monitoring.Methods Using an isotopic internal standard method,the serum samples were pretreated with protein precipitation.The supernatant was diluted after centrifugation,and detected by liquid chromatography-tandem mass spectrometer.Refer-ring to the Recommendations for Clinical Application of Liquid Chromatography-Mass Spectrometry(LC-MS)and Clinical and Labora-tory Standards Instituhe(CLSI)C62A,the performance of the LC-MS method was verified,including quantitation limits,linearity,trueness,precision,matrix effect,carry-over,interference,dilution consistency and stability.The blood samples from patients who were treated with fluconazole,linezolid,voriconazole,and contezolid were collected and measured for trough or peak concentrations.Results The quantitation limits of fluconazole,linezolid,voriconazole and contezolid by this method were 1 μg/mL,0.25 μg/mL,0.25 μg/mL and 0.1 μg/mL,respectively.The linear ranges were 1-100 μg/mL,0.25-25 μg/mL,0.25-25 μg/mL,and 0.1-10μg/mL,respectively.The recovery rates were 103.0%-105.7%,103.1%-108%,102.4%-106.2%and 101.0%-109.9%,respectively.The precisions,expressed as coefficient of variation(CV),were 1.7%-3.4%,2.1%-4.8%,1.9%-3.1%,and 3.1%-6.8%,respective-ly.No obvious matrix effect,carry-over contamination and interference were found.The dilution consistency and stability were satisfac-tory.The concentrations of fluconazole,linezolid and voriconazole within the reference interval accounted for 49.1%,52.5%and 80.7%of the total samples,respectively.The peak concentration of contezolamide was(14.02±4.94)μg/mL(n=4),and the trough concen-tration was(0.34±0.20)μg/mL(n=5).Conclusion In this study,a method for simultaneous analysis of the concentrations of flu-conazole,linezolid,voriconazole and contezolid was successfully established and verified by liquid chromatography-tandem mass spec-trometry.This method is simple,rapid,and suitable for therapeutic drug monitoring,and providing a basis for the optimization of drug regimens.
2.A cross-sectional study of retrospective clinical liquid chromatography-tandem mass spectrometry detection consistency comparison program
Wenda CHEN ; Jiexin LIU ; Yingfei PENG ; Fangjun CHEN ; Jiaqian QIN ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Laboratory Medicine 2025;48(12):1565-1570
Objective:? To summarize the achievements in improving the consistency of clinical liquid chromatography-tandem mass spectrometry (LC-MS/MS) testing results.Methods:? From 2021 to 2024, Zhongshan Hospital Affiliated to Fudan University recruited laboratories voluntarily participating in the MSHP (Clinical LC-MS/MS Testing Consistency Program). As of Batch 202404, a total of 76 laboratories had enrolled, including 60 medical institutions (all tertiary hospitals) and 16 third-party laboratories. Test items were established, and comparative samples were distributed regularly-each item′s samples covered three concentrations (high, medium, and low). Samples were shipped via cold chain and tested within one week. Our laboratory′s measurements served as the target, with participating labs′ results within ±25% of the target deemed qualified. Passing-Bablok regression and Bland-Altman analysis were used to assess consistency.Results:Taking 3-MT (3-methoxytyramine) as an example, the coefficients of variation (CVs) for the project′s three concentration levels improved from 17.00%, 47.18%, and 4.88% in the first comparative batch to 9.59%, 9.59%, and 6.1% in Batch 202404. Passing-Bablok regression results for the 5 units participating in 3-MT testing showed that Laboratory A had proportional bias but no systematic bias (regression slope [95% CI]: 0.903 [0.862-0.952]; intercept [95% CI]: 0.912 [-1.921-6.073]). The remaining laboratories exhibited no proportional or systematic bias with the target (Laboratory B: slope 1.031 [0.961-1.147], intercept-0.733 [-4.641-8.272]; Laboratory C: slope 0.982 [0.940-1.009], intercept-0.576 [-2.675-1.891]; Laboratory D: slope 0.973 [0.939-1.066], intercept-1.168 [-6.108-1.649]; Laboratory E: slope 0.999 [0.905-1.051], intercept-1.876 [-6.111-3.508]). Bland-Altman analysis indicated that all 5 laboratories′ results generally showed good consistency with the target. Through quality feedback and optimizing sample preparation concentrations, result consistency was enhanced.? Conclusion:? Clinical LC-MS/MS testing consistency programs contribute to improving the comparability of test results.
3.Establishment and evaluation of a method for simultaneous analysis of fluconazole,linezolid,voriconazole and contezolid by liquid chromatography-tandem mass spectrometry
Jiexin LIU ; Lei CAO ; Yingfei PENG ; Jiaqian QIN ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Clinical Laboratory Science 2025;43(4):241-245
Objective To establish and validate a method for simultaneous analysis of fluconazole,linezolid,voriconazole and cont-ezolid by liquid chromatography-tandem mass spectrometry,and conduct preliminary assessment its value of application value in clinical therapeutic drug monitoring.Methods Using an isotopic internal standard method,the serum samples were pretreated with protein precipitation.The supernatant was diluted after centrifugation,and detected by liquid chromatography-tandem mass spectrometer.Refer-ring to the Recommendations for Clinical Application of Liquid Chromatography-Mass Spectrometry(LC-MS)and Clinical and Labora-tory Standards Instituhe(CLSI)C62A,the performance of the LC-MS method was verified,including quantitation limits,linearity,trueness,precision,matrix effect,carry-over,interference,dilution consistency and stability.The blood samples from patients who were treated with fluconazole,linezolid,voriconazole,and contezolid were collected and measured for trough or peak concentrations.Results The quantitation limits of fluconazole,linezolid,voriconazole and contezolid by this method were 1 μg/mL,0.25 μg/mL,0.25 μg/mL and 0.1 μg/mL,respectively.The linear ranges were 1-100 μg/mL,0.25-25 μg/mL,0.25-25 μg/mL,and 0.1-10μg/mL,respectively.The recovery rates were 103.0%-105.7%,103.1%-108%,102.4%-106.2%and 101.0%-109.9%,respectively.The precisions,expressed as coefficient of variation(CV),were 1.7%-3.4%,2.1%-4.8%,1.9%-3.1%,and 3.1%-6.8%,respective-ly.No obvious matrix effect,carry-over contamination and interference were found.The dilution consistency and stability were satisfac-tory.The concentrations of fluconazole,linezolid and voriconazole within the reference interval accounted for 49.1%,52.5%and 80.7%of the total samples,respectively.The peak concentration of contezolamide was(14.02±4.94)μg/mL(n=4),and the trough concen-tration was(0.34±0.20)μg/mL(n=5).Conclusion In this study,a method for simultaneous analysis of the concentrations of flu-conazole,linezolid,voriconazole and contezolid was successfully established and verified by liquid chromatography-tandem mass spec-trometry.This method is simple,rapid,and suitable for therapeutic drug monitoring,and providing a basis for the optimization of drug regimens.
4.A cross-sectional study of retrospective clinical liquid chromatography-tandem mass spectrometry detection consistency comparison program
Wenda CHEN ; Jiexin LIU ; Yingfei PENG ; Fangjun CHEN ; Jiaqian QIN ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Laboratory Medicine 2025;48(12):1565-1570
Objective:? To summarize the achievements in improving the consistency of clinical liquid chromatography-tandem mass spectrometry (LC-MS/MS) testing results.Methods:? From 2021 to 2024, Zhongshan Hospital Affiliated to Fudan University recruited laboratories voluntarily participating in the MSHP (Clinical LC-MS/MS Testing Consistency Program). As of Batch 202404, a total of 76 laboratories had enrolled, including 60 medical institutions (all tertiary hospitals) and 16 third-party laboratories. Test items were established, and comparative samples were distributed regularly-each item′s samples covered three concentrations (high, medium, and low). Samples were shipped via cold chain and tested within one week. Our laboratory′s measurements served as the target, with participating labs′ results within ±25% of the target deemed qualified. Passing-Bablok regression and Bland-Altman analysis were used to assess consistency.Results:Taking 3-MT (3-methoxytyramine) as an example, the coefficients of variation (CVs) for the project′s three concentration levels improved from 17.00%, 47.18%, and 4.88% in the first comparative batch to 9.59%, 9.59%, and 6.1% in Batch 202404. Passing-Bablok regression results for the 5 units participating in 3-MT testing showed that Laboratory A had proportional bias but no systematic bias (regression slope [95% CI]: 0.903 [0.862-0.952]; intercept [95% CI]: 0.912 [-1.921-6.073]). The remaining laboratories exhibited no proportional or systematic bias with the target (Laboratory B: slope 1.031 [0.961-1.147], intercept-0.733 [-4.641-8.272]; Laboratory C: slope 0.982 [0.940-1.009], intercept-0.576 [-2.675-1.891]; Laboratory D: slope 0.973 [0.939-1.066], intercept-1.168 [-6.108-1.649]; Laboratory E: slope 0.999 [0.905-1.051], intercept-1.876 [-6.111-3.508]). Bland-Altman analysis indicated that all 5 laboratories′ results generally showed good consistency with the target. Through quality feedback and optimizing sample preparation concentrations, result consistency was enhanced.? Conclusion:? Clinical LC-MS/MS testing consistency programs contribute to improving the comparability of test results.
5.Evaluation of the safety and efficacy of mitomycin C-perfluorooctyl bromide liposome nanoparticles in the treatment of human pterygium fibroblasts
Tao LI ; Lingshan LIAO ; Shenglan ZHU ; Juan TANG ; Xiaoli WU ; Qilin FANG ; Ying LI ; Biao LI ; Qin TIAN ; Junmei WAN ; Yi YANG ; Yueyue TAN ; Jiaqian LI ; Juan DU ; Yan ZHOU ; Dan ZHANG ; Xingde LIU
Recent Advances in Ophthalmology 2024;44(2):100-105
Objective To prepare a nano drug(PFOB@Lip-MMC)with liposome as the carrier,liquid perfluorooc-tyl bromide(PFOB)as core and mitomycin C(MMC)loading on the liposome shell and study its inhibitory effect on the proliferation of human pterygium fibroblasts(HPFs).Methods The thin film dispersion-hydration ultrasonic method was used to prepare PFOB@Lip-MMC and detect its physical and chemical properties.Cell Counting Kit-8,Cam-PI cell viability staining and flow cytometry were employed to detect the impact of different concentrations of PFOB@Lip-MMC on the via-bility of HPFs.DiI fluorescence labeled PFOB@Lip-MMC was used to observe the permeability of the nano drug to HPFs under a laser confocal microscope.After establishing HPF inflammatory cell models,they were divided into the control group(with sterile phosphate-buffered saline solution added),PFOB@Lip group(with PFOB@Lip added),MMC group(with MMC added),PFOB@Lip-MMC group(with PFOB@Lip-MMC added)and normal group(with fresh culture medi-um added)according to the experimental requirements.After co-incubation for 24 h,flow cytometer was used to detect the apoptosis rate of inflammatory cells,and the gene expression levels of interleukin(IL)-1β,prostaglandin E2(PGE2),tumor necrosis factor(TNF)-α and vascular endothelial growth factor(VEGF)in cells were analyzed by PCR.Results The average particle size and Zeta potential of PFOB@Lip-MMC were(103.45±2.17)nm and(27.34±1.03)mV,respec-tively,and its entrapped efficiency and drug loading rate were(72.85±3.28)%and(34.27±2.04)%,respectively.The sustained-release MMC of drug-loaded nanospheres reached(78.34±2.92)%in vitro in a 24-hour ocular surface environ-ment.The biological safety of PFOB@Lip-MMC significantly improved compared to MMC.In terms of the DiI fluorescence labeled PFOB@Lip-MMC,after co-incubation with inflammatory HPFs for 2 h,DiI fluorescence labeling was diffusely dis-tributed in the cytoplasm of inflammatory HPFs.The apoptosis rate of inflammatory HPFs in the PFOB@Lip-MMC group[(77.23±4.93)%]was significantly higher than that in the MMC group[(51.62±3.28)%].The PCR examination results showed that the gene transcription levels of IL-1 β,PGE2,TNF-α and VEGF in other groups were significantly reduced com-pared to the control group and PFOB@Lip group,with the most significant decrease in the PFOB@Lip-MMC group(all P<0.05).Conclusion In this study,a novel nano drug(PFOB@LIP-MMC)that inhibited the proliferation of HPFs was successfully synthesized,and its cytotoxicity was significantly reduced compared to the original drugs.It has good bio-compatibility and anti-inflammatory effects,providing a new treatment approach for reducing the recurrence rate after pte-rygium surgery.
6.Liquid chromatography-tandem mass spectrometry (LC-MS/MS) based assay for the quantification of melatonin in human serum
Yingfei PENG ; Zhenxin WANG ; Fangjun CHEN ; Jiaqian QIN ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Laboratory Medicine 2024;47(7):812-818
Objective:The aim of this study was to develop and validate a new liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the quantification of melatonin in human serum.Methods:We describe the performance and validation of melatonin by LC-MS/MS. 182 serum samples from the patients diagnosed with Sleep disturbance who visited the Department of Psychiatry at Zhongshan Hospital affiliated to Fudan University from February 2022 to March 2023(56 males,162 females,mean age [45.51±16.31]years), as well as 182 healthy individuals were included(87 males,95 females,mean age [48.55±11.93]years). The two groups were used to assess the application of serum melatonin levels as a diagnostic indicator for sleep disorders (SDs). The liquid chromatography mass spectrometry (LC-MS) system with an chromatography column (2.1×100 mm, 1.8 μm) was used for separation. The column temperature was set at 35 ℃, as well as the mobile phase consisting of a 0.1% formic acid aqueous solution and pure acetonitrile. The flowing rate was set at 0.4 ml/min for gradient elution. The LC-MS/MS method was validated according to guidance documents, including the following parameters: specificity, selectivity, matrix effect, carryover contamination and reproducibility, lower limit of measuring interval, linearity, precision, recovery rate, dilution consistency, and serum sample stability. Then, it was subsequently employed to profile melatonin changes in Sleep disturbance.Results:The lower limit of quantification for melatonin was 1 pg/ml, and the linear range of detection was 1 pg/ml to 500 pg/ml ( r=0.999). The intra-day and intra-batch precision, expressed as the coefficient of variation ( CV), was within the range from 3.07% to 6.86%, which met the requirement of less than 15%. The recovery rate of the spiked samples ranged from 105.91% to 116.30%. The level of serum melatonin in the sleep disturbance group was significantly lower than that in the healthy control group ([2.00(1.00,3.28)] vs [8.35(4.28,14.80)] pg/ml, P<0.001). Conclusions:The LC-MS/MS method we developed for the quantification of melatonin is clinical practicable.
7.Magnetic nanoparticle method for detecting circulating tumor cells of lung cancer: A pilot study
XU Yuan ; LIANG Naixin ; LIU Hongsheng ; LI Li ; HUANG Cheng ; QIN Yingzhi ; BING Zhongxing ; PENG Jiaqian ; LI Wenzhe ; YANG Yanlian ; HU Zhiyuan ; LI Shanqing
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2018;25(8):691-695
Objective To explore the diagnostic value of circulating tumor cells (CTC) measured by magnetic nanoparticle method in lung cancer. Methods (1) We measured binding capability of A549 or NCI-H1965 cell lines with recognition peptide and capture efficiency by adding tumor cells into the whole blood of healthy human. (2) We measured CTC of 34 patients suspected with lung cancer, and the counting results of CTC were compared with the following pathological results. Results (1) The binding capability was 80.0%±6.0% for A549 and 70.1%±4.8% for H1957, while the capture efficiency was 57.3%±7.0% for A549 and 37.3%±6.1% for H1975. (2) CTCs were identified in 71.9% of patients with lung cancer. The specificity was 83.3%, and area under receiver operating characteristic (ROC) curve was 0.792 (P=0.003). Conclusion CTC measured by magnetic nanoparticle method has promising application in the diagnosis of lung cancer.
8.Development of a LC-MS/MS method for determination of plasma aldosterone and its performance evaluation
Jiaqian QIN ; Fangjun CHEN ; Yingfei PENG ; Jiong WU ; Chunyan ZHANG ; Beili WANG ; Wei GUO ; Baishen PAN
Chinese Journal of Laboratory Medicine 2017;40(4):247-252
Objective We are going to establish a robust liquid chromatography-tandem mass spectrometric(LC-MS/MS) method for plasma aldosterone assay.Methods 324 healthy individuals were enrolled in Zhongshan Hospital from February to April in 2016 for reference interval survey.The signallinearity,lower limits of quantitation,precision and accuracy of LC-MS/MS have been evaluated.Results from LC-MS/MS and RIA methods were compared.Software SPSS17.0 software was used for statistical analysis.Results The performance characteristics for the method in terms of linearity,lowerlimits of quantitation,precision and accuracy were verified.Linear range of ALD were between 25-2000 pg/ml;the LC-MS/MS assay had a limit of quantitation of 20 pg/ml for ALD;the intra-and inter-assay CV of ALD were <10% and <6%,respectively;the recovery of ALD from serum samples ranged between 97.3 and 105.8% The reference value of ALD in health people ranged between 21-211.6 pg/ml The regression equation by LC-MS/MS (X) and RIA (Y) was:Y =0.271X + 138.900(r=0.43;n=322).Conclusion LC-MS/MS method is robust and reliable for the analysis of aldosterone in plasma and suitable for clinical application.
9.Efficacy analysis of targeted therapy combined with surgery in the treatment of recurrent and metastatic gastrointestinal stromal tumor.
Xiaodong GAO ; Anwei XUE ; Yong FANG ; Ping SHU ; He LI ; Jiaqian LING ; Li WANG ; Yingyong HOU ; Kuntang SHEN ; Jing QIN ; Yihong SUN ; Xinyu QIN ;
Chinese Journal of Gastrointestinal Surgery 2016;19(11):1282-1285
OBJECTIVETo investigate the efficacy of targeted therapy combined with surgery in the treatment of recurrent and metastatic gastrointestinal stromal tumor(GIST).
METHODSClinicopathological and followed-up data of 318 patients with recurrent and metastatic GIST admitted in Zhongshan Hospital between January 2000 and December 2015 were analyzed retrospectively. According to different treatment methods, the patients were divided into four groups: surgery group (operation alone, 44 cases), target therapy group (imatinib alone, 108 cases), target therapy combined with surgery group (imatinib plus operation, 139 cases), other therapy group (chemotherapy, Chinese medicine and others, 27 cases). The progression-free survival (PFS) and overall survival (OS) of four groups were compared.
RESULTSThe baseline informations, such as age, gender, primary site, et al, were not significantly different (all P>0.05), but the recurrent and metastatic site was significantly different among 4 groups (P=0.000). The medial PFS of surgery group, target therapy group, target therapy combined with surgery was 16(95%CI: 4.9 to 27.0) months, 44 (95%CI: 30.9 to 57.1) months, 35 (95%CI: 26.5 to 43.5) months, respectively, and the latter 2 groups had significantly longer PFS than surgery group(P=0.000), while no significant difference was found between target therapy group and target combined with surgery group (P=0.251). The median OS of surgery group, target therapy group, target therapy combined with surgery, and other therapy group was 24 (95%CI: 9.0 to 39.0) months, 69(95%CI: 40.8 to 97.2) months, 92(95%CI: 78.0 to 106.0) months, 12(95%CI: 9.5 to 14.5) months. Target therapy group and target therapy combined with surgery group had significantly longer OS than surgery and other therapy groups (P=0.000), while the target therapy combined with surgery group had significantly longer OS than target therapy group(P=0.028).
CONCLUSIONTarget therapy combined with surgery can prolong the survival of recurrent and metastatic GIST patients.
Antineoplastic Agents ; therapeutic use ; Benzamides ; Combined Modality Therapy ; Disease-Free Survival ; Female ; Gastrointestinal Stromal Tumors ; drug therapy ; pathology ; surgery ; Humans ; Imatinib Mesylate ; therapeutic use ; Male ; Middle Aged ; Piperazines ; Pyrimidines ; Retrospective Studies
10.Clinicopathological features of small gastrointestinal stromal tumors.
Xiaodong GAO ; Anwei XUE ; Yong FANG ; Ping SHU ; Jiaqian LING ; Jianwei HU ; Yingyong HOU ; Kuntang SHEN ; Jing QIN ; Yihong SUN ; Xinyu QIN
Chinese Journal of Gastrointestinal Surgery 2015;18(4):338-341
OBJECTIVETo investigate the clinicopathological features of small gastrointestinal stromal tumors(GISTs) and to evaluate the efficacy of endoscopic therapy for GISTs.
METHODSClinicopathological and follow-up data of 418 patients with GISTs undergoing endoscopic therapy in the Zhongshan Hospital between January 2009 and July 2014 were analyzed retrospectively. All the cases were evaluated by the NIH risk classification and AIFP classification, and were grouped according to the tumor size and location. Nuclear atypia and mitotic count were used to evaluate the biological behavior of small GIST. Efficacy of endoscopic therapy was analyzed with follow-up data.
RESULTSOut of 418 patients, GISTs located in the esophagus was 14(3.3%), in the stomach 389(93.1%), in the duodenum 5(1.2%), in the rectum 10(2.4%). A total of 412(98.6%) patients were mainly spindle cells, and mitosis was not found in 320(76.5%) patients. In 389 small stomach GIST, 245(58.6%) were in fundic region. Cases were divided into four groups according to the size and the result revealed the bigger the size, the more the mitotic count. Nuclear atypia in the 1.5-1.9 cm group was significantly higher compared to other groups. Cases were divided into four groups according to the location and the result revealed the mitotic count was not associated to the location. While the nuclear atypia of stomach GIST was significantly higher than that of esophageal GIST and the nuclear atypia of rectum GIST was significantly higher than that of other positions. The median follow-up was 32(4-69) months. One case(gastric fundus GIST, >1.5 cm) presented local recurrence 23 months after operation and underwent endoscopic resection again. No recurrence or metastasis was found in other patients.
CONCLUSIONSEndoscopic resection technique is effective for small GISTs patients. The small GISTs with 0.4 cm diameter or less are often benign and should be followed up for long time. The small GISTs with 0.5 cm diameter or more possess the risk of malignancy, then surgical resection should be performed. Rectum small GISTs (except for 0.4 cm diameter or less) have worse biological behavior and should be removed.
Gastrointestinal Neoplasms ; Gastrointestinal Stromal Tumors ; Humans ; Neoplasm Recurrence, Local ; Retrospective Studies

Result Analysis
Print
Save
E-mail