1.The role of magnetocardiography in the diagnosis and efficacy assessment of coronary microvascular dysfunction
Jiaqi MA ; Danbo LU ; Zhangwei CHEN ; Ao CHEN ; Congcong PAN ; Juying QIAN ; Jianying MA
Chinese Journal of Clinical Medicine 2026;33(1):31-37
Objective To explore the non-invasive diagnostic criteria of magnetocardiography (MCG) for coronary microvascular dysfunction (CMVD), and its value in dynamically assessing drug treatment for CMVD. Methods Patients who presented with chest tightness or chest pain at Zhongshan Hospital, Fudan University from September 2024 to March 2025 were consecutively enrolled, and all of whom had non-obstructive coronary arteries on angiography. Using the coronary angiography-derived index of microcirculatory resistance (caIMR) as the gold standard, patients were divided into a normal microcirculation group (caIMR≤40 U) and a CMVD group (caIMR>40 U). MCG testing was performed using a domestic device (MD-U041001, Mind Medical). Patients in the CMVD group received adenosine treatment and underwent repeat MCG after medication. Differences in MCG parameters between the two groups were analyzed, and a diagnostic model was established. The value of the diagnostic model was analyzed using receiver operating characteristic (ROC) curves. Results A total of 311 patients were included, with 135 in the normal microcirculation group and 176 in the CMVD group. The CMVD group had a significantly higher proportion of males (61.9% vs 47.4%, P=0.012), and lower high-density lipoprotein cholesterol (HDL-C) levels ([1.16±0.31] mmol/L vs [1.24±0.29] mmol/L, P=0.029) than the normal group. Eleven MCG parameters showed significant differences between the two groups (P<0.05), among which increased values of mfm_QR_epav, mfm_RS_epmse, space_zeroRTrot, as well as decreased value of mfm_QR_v1 were independent predictors of CMVD. The diagnostic model based on these 11 MCG parameters yielded an area under the curve (AUC) of 0.688 (95%CI 0.629-0.747). The integrated diagnostic model combining clinical risk factors (male, smoking history, HDL-C) with MCG parameters had an AUC of 0.701 (95%CI 0.643-0.759). After adenosine treatment, patients in the CMVD group showed significant decreases in mfm_QR_epav (P=0.010), mfm_RS_sad (P=0.013), and mfm_RS_epmse (P=0.046). Conclusions The model based on MCG parameters demonstrates good diagnostic ability for CMVD; dynamic changes in MCG parameters following adenosine intervention may serve as potential objective indicators for evaluating microcirculatory treatment efficacy.
2.Evaluation of the alveolar ridge preservation effect of immediate implantation using the improved CBCT measuring method
Xiang GUO ; Jianying ZHANG ; Yiming WANG ; Zhen MA ; Yang XUE ; Hongzhi ZHOU ; Kaijin HU ; Tiange DENG
Journal of Practical Stomatology 2025;41(3):372-379
Objective:To evaluate the alveolar ridge preservation effect of immediate implantation at extraction site with the im-proved CBCT measuring method.Methods:Eighty patients with extraction site were divided into test group A,B,C and control group.The patients were treated by means of immediate implant placement combined with large flap surgery,guided bone regener-ation(GBR)using mass Bio-Oss bone particles in the group A(the thickness of facial bone wall<1 mm);The patients were trea-ted by means of immediate implant placement combined without flap surgery and bone graft in the group B(the thickness of facial bone wall ≥1 mm and<2 mm)and C(the thickness of facial bone wall ≥2 mm),the CGF was implanted in the jumping space only when the thickness of jumping space was>2 mm.In the control group,the alveolar sockets healed naturally without any in-tervention or treatment.CBCT was taken before surgery,immediately after surgery,and 6 months after surgery to evaluate the height and width of alveolar bone,the thickness of facial bone wall and jumping space.Results:The reduction of alveolar ridge height in group A,B,C and control group was(0.41±0.13,0.94±0.18,0.59±0.12,1.31±0.19)mm,The reduction of alveolar ridge width in group A,B,C and control group was(0.93±0.10,1.48±0.21,1.12±0.17,1.66±0.16)mum.The re-sults of four groups were statistically different(F=177.0,P<0.001;F=125.3,P<0.001).The alveolar ridge thickness of facial bone wall in group A,B,C and con-trol group was(0.98±0.25,2.39±0.28)mm,(1.43±0.52,2.10±0.33)mm,(2.17±0.41,2.79±0.27)mm before surgery and six months after immediate implantation.The results of each group were statistically different between before surgery and six months after immediate implantation(t=16.45,P<0.001;t=7.357,P<0.001;t=5.488,P<0.001).Patients in three test groups had the thickness of jumping space>2 mm and ≤2 mm,and the reduction of alveolar ridge width was(0.78±0.18,0.88±0.17)mm.The results were statistically different(t=17.18,P=0.018).Conclusion:The alveolar ridge preservation was obtained by means of immediate implant placement combined with large flap surgery,guided bone regeneration(GBR)using mass Bio-Oss bone particles at extraction site with the thickness of facial bone wall<1 mm;The alveolar ridge preservation was obtained without flap surgery and GBR at extraction site with the thickness of facial bone wall≥1 mm.The preservation of soft and hard tissue was better in the axial palatal side of immediate implantation with the thickness of jumping space>2 mm than that with the thickness of jumping space≤2 mm.
3.Evaluation of the alveolar ridge preservation effect of immediate implantation using the improved CBCT measuring method
Xiang GUO ; Jianying ZHANG ; Yiming WANG ; Zhen MA ; Yang XUE ; Hongzhi ZHOU ; Kaijin HU ; Tiange DENG
Journal of Practical Stomatology 2025;41(3):372-379
Objective:To evaluate the alveolar ridge preservation effect of immediate implantation at extraction site with the im-proved CBCT measuring method.Methods:Eighty patients with extraction site were divided into test group A,B,C and control group.The patients were treated by means of immediate implant placement combined with large flap surgery,guided bone regener-ation(GBR)using mass Bio-Oss bone particles in the group A(the thickness of facial bone wall<1 mm);The patients were trea-ted by means of immediate implant placement combined without flap surgery and bone graft in the group B(the thickness of facial bone wall ≥1 mm and<2 mm)and C(the thickness of facial bone wall ≥2 mm),the CGF was implanted in the jumping space only when the thickness of jumping space was>2 mm.In the control group,the alveolar sockets healed naturally without any in-tervention or treatment.CBCT was taken before surgery,immediately after surgery,and 6 months after surgery to evaluate the height and width of alveolar bone,the thickness of facial bone wall and jumping space.Results:The reduction of alveolar ridge height in group A,B,C and control group was(0.41±0.13,0.94±0.18,0.59±0.12,1.31±0.19)mm,The reduction of alveolar ridge width in group A,B,C and control group was(0.93±0.10,1.48±0.21,1.12±0.17,1.66±0.16)mum.The re-sults of four groups were statistically different(F=177.0,P<0.001;F=125.3,P<0.001).The alveolar ridge thickness of facial bone wall in group A,B,C and con-trol group was(0.98±0.25,2.39±0.28)mm,(1.43±0.52,2.10±0.33)mm,(2.17±0.41,2.79±0.27)mm before surgery and six months after immediate implantation.The results of each group were statistically different between before surgery and six months after immediate implantation(t=16.45,P<0.001;t=7.357,P<0.001;t=5.488,P<0.001).Patients in three test groups had the thickness of jumping space>2 mm and ≤2 mm,and the reduction of alveolar ridge width was(0.78±0.18,0.88±0.17)mm.The results were statistically different(t=17.18,P=0.018).Conclusion:The alveolar ridge preservation was obtained by means of immediate implant placement combined with large flap surgery,guided bone regeneration(GBR)using mass Bio-Oss bone particles at extraction site with the thickness of facial bone wall<1 mm;The alveolar ridge preservation was obtained without flap surgery and GBR at extraction site with the thickness of facial bone wall≥1 mm.The preservation of soft and hard tissue was better in the axial palatal side of immediate implantation with the thickness of jumping space>2 mm than that with the thickness of jumping space≤2 mm.
4.Research Progress on Artemisinin and Its Derivatives to Improve Female Reproductive Diseases
Jianying CHANG ; Mingyue WEI ; Jingjing LI ; Zilong CHEN ; Yujin MA ; Huifeng MA ; Lei ZHANG ; Tao JIANG ; Chuanxin LIU ; Hongwei JIANG
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(11):3386-3399
The female reproductive system is essential for sustaining reproductive endocrine homeostasis,however,its vulnerability to various endogenous and exogenous insults,including pathological conditions,pharmacological agents,genetic predispositions,and environmental factors,often results in compromised fertility.The existing protective approaches(including surgical interventions,hormonal replacement therapies,and assisted reproductive techniques)are constrained by several limitations,such as adverse therapeutic effects,technical complexities,and their incapacity to reverse ovarian senescence.Artemisinin and its derivatives(ARTs),characterized by their unique endoperoxide bridge configuration,have exhibited outstanding therapeutic performance across multiple domains including malaria treatment,anticancer therapy,inflammation modulation,and parasitic infection control.Emerging research has identified their novel protective capabilities against various reproductive system pathologies.This comprehensive review systematically elucidates the molecular mechanisms underlying artemisinin-based interventions in reproductive pathologies and evaluates their clinical translation prospects,thereby proposing innovative strategies for the development of next-generation fertility-protective agents with enhanced safety and efficacy profiles.
5.Research Progress on Artemisinin and Its Derivatives to Improve Female Reproductive Diseases
Jianying CHANG ; Mingyue WEI ; Jingjing LI ; Zilong CHEN ; Yujin MA ; Huifeng MA ; Lei ZHANG ; Tao JIANG ; Chuanxin LIU ; Hongwei JIANG
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(11):3386-3399
The female reproductive system is essential for sustaining reproductive endocrine homeostasis,however,its vulnerability to various endogenous and exogenous insults,including pathological conditions,pharmacological agents,genetic predispositions,and environmental factors,often results in compromised fertility.The existing protective approaches(including surgical interventions,hormonal replacement therapies,and assisted reproductive techniques)are constrained by several limitations,such as adverse therapeutic effects,technical complexities,and their incapacity to reverse ovarian senescence.Artemisinin and its derivatives(ARTs),characterized by their unique endoperoxide bridge configuration,have exhibited outstanding therapeutic performance across multiple domains including malaria treatment,anticancer therapy,inflammation modulation,and parasitic infection control.Emerging research has identified their novel protective capabilities against various reproductive system pathologies.This comprehensive review systematically elucidates the molecular mechanisms underlying artemisinin-based interventions in reproductive pathologies and evaluates their clinical translation prospects,thereby proposing innovative strategies for the development of next-generation fertility-protective agents with enhanced safety and efficacy profiles.
6.Expert consensus on perioperative clinical nursing standards for patients undergoing percutaneous renal biopsy (2024 edition)
Yan WANG ; Junye TIAN ; Yuan HAN ; Liyun CAO ; Fude ZHOU ; Ruxia WANG ; Yanmeng GUAN ; Dong PANG ; Jingfen JIN ; Yanming DING ; Ting CHEN ; Xiaohong YIN ; Jing HUANG ; Dengyan MA ; Jianying LI ; Chunyue LI
Chinese Journal of Modern Nursing 2025;31(19):2521-2528
To provide scientific guidance and standardization for perioperative clinical nursing practice in patients undergoing percutaneous renal biopsy, relevant evidence on percutaneous renal biopsy nursing care was systematically retrieved and synthesized through an evidence-based approach. After two rounds of Delphi expert consultation and expert panel discussions, expert consensus on perioperative clinical nursing standards for patients undergoing percutaneous renal biopsy (hereinafter referred to as the "Consensus") was developed. The Consensus includes three primary themes: preoperative care, intraoperative care, and postoperative care, encompassing 21 secondary themes. It is characterized by scientific rigor, practical applicability, and comprehensiveness, and serves as a valuable reference and guide for clinical nursing professionals across medical institutions.
7.Expert consensus on perioperative clinical nursing standards for patients undergoing percutaneous renal biopsy (2024 edition)
Yan WANG ; Junye TIAN ; Yuan HAN ; Liyun CAO ; Fude ZHOU ; Ruxia WANG ; Yanmeng GUAN ; Dong PANG ; Jingfen JIN ; Yanming DING ; Ting CHEN ; Xiaohong YIN ; Jing HUANG ; Dengyan MA ; Jianying LI ; Chunyue LI
Chinese Journal of Modern Nursing 2025;31(19):2521-2528
To provide scientific guidance and standardization for perioperative clinical nursing practice in patients undergoing percutaneous renal biopsy, relevant evidence on percutaneous renal biopsy nursing care was systematically retrieved and synthesized through an evidence-based approach. After two rounds of Delphi expert consultation and expert panel discussions, expert consensus on perioperative clinical nursing standards for patients undergoing percutaneous renal biopsy (hereinafter referred to as the "Consensus") was developed. The Consensus includes three primary themes: preoperative care, intraoperative care, and postoperative care, encompassing 21 secondary themes. It is characterized by scientific rigor, practical applicability, and comprehensiveness, and serves as a valuable reference and guide for clinical nursing professionals across medical institutions.
8.Biomimetic dual-cell membrane nanoprobes employed for bimodal fluorescence-MR imaging of pancreatic cancer
Yanqi ZHONG ; Yingying MA ; Wenzheng LU ; Heng ZHANG ; Yuxi GE ; Peng WANG ; Jing ZHAO ; Jianying QIAN ; Jingxiao CHEN ; Shudong HU
Chinese Journal of Nuclear Medicine and Molecular Imaging 2025;45(2):88-93
Objective:To construct fused cancer cell/neutrophil membrane-coated polydopamine nanoparticles chelated with manganese ions (Ⅱ) (PMNP@FMs) and explore the potential for targeted pancreatic cancer fluorescence imaging and MRI.Methods:Cancer cell membranes fused with neutrophil membranes were encapsulated on the surface of polydopamine nanoparticles chelated with manganese ions (Ⅱ) (PMNPs) to prepare PMNP@FMs. The morphology, structure, and MRI performance of the product were characterized. The cytotoxicity of PMNP@FMs towards human pancreatic cancer cells (PANC-1) and normal human pancreatic ductal epithelial cells (hTERT-HPNE) was evaluated using cell counting kit (CCK)-8, and in vivo toxicity was assessed in healthy mice. PANC-1 pancreatic cancer xenograft nude mouse models were established for in vivo fluorescence imaging and MRI. Data were analyzed using the independent-sample t test, repeated measures analysis of variance and the least significance difference method. Results:PMNP@FMs exhibited a core-shell structure with a diameter of (112.81±8.64) nm, negative surface charge, and good dispersibility. The T 1 relaxivity of PMNPs was 18.81±0.22, which was 4.1 times higher than that of gadopentetate dimeglumine (Gd-DTPA) (4.55±0.24; t=75.54, P<0.001). Co-culture of PMNPs and PMNP@FMs with hTERT-HPNE and PANC-1 cells for 24 h resulted in cell viability above 90% within the concentration range of 0-500 μg/ml. PMNP@FMs did not affect mouse survival and showed no apparent organ damage. In vivo fluorescence imaging and MRI revealed that PMNP@FMs accumulated highly in tumors and reached the peak 24 h post intravenous administration (relative MR signal: 1.35±0.01, fluorescence intensity: (1.20±0.25)×10 10), surpassing the peak observed in the control group (1.22±0.01, (3.87±0.50)×10 9;F values: 11.03-188.01, t values: 18.20, 5.64, all P<0.05), with hepatic metabolism being the primary route of clearance. Conclusion:PMNP@FMs demonstrate a potential for targeted pancreatic cancer fluorescence imaging and MRI, offering promising prospect for precise diagnosis of early-stage pancreatic cancer.
9.Biomimetic dual-cell membrane nanoprobes employed for bimodal fluorescence-MR imaging of pancreatic cancer
Yanqi ZHONG ; Yingying MA ; Wenzheng LU ; Heng ZHANG ; Yuxi GE ; Peng WANG ; Jing ZHAO ; Jianying QIAN ; Jingxiao CHEN ; Shudong HU
Chinese Journal of Nuclear Medicine and Molecular Imaging 2025;45(2):88-93
Objective:To construct fused cancer cell/neutrophil membrane-coated polydopamine nanoparticles chelated with manganese ions (Ⅱ) (PMNP@FMs) and explore the potential for targeted pancreatic cancer fluorescence imaging and MRI.Methods:Cancer cell membranes fused with neutrophil membranes were encapsulated on the surface of polydopamine nanoparticles chelated with manganese ions (Ⅱ) (PMNPs) to prepare PMNP@FMs. The morphology, structure, and MRI performance of the product were characterized. The cytotoxicity of PMNP@FMs towards human pancreatic cancer cells (PANC-1) and normal human pancreatic ductal epithelial cells (hTERT-HPNE) was evaluated using cell counting kit (CCK)-8, and in vivo toxicity was assessed in healthy mice. PANC-1 pancreatic cancer xenograft nude mouse models were established for in vivo fluorescence imaging and MRI. Data were analyzed using the independent-sample t test, repeated measures analysis of variance and the least significance difference method. Results:PMNP@FMs exhibited a core-shell structure with a diameter of (112.81±8.64) nm, negative surface charge, and good dispersibility. The T 1 relaxivity of PMNPs was 18.81±0.22, which was 4.1 times higher than that of gadopentetate dimeglumine (Gd-DTPA) (4.55±0.24; t=75.54, P<0.001). Co-culture of PMNPs and PMNP@FMs with hTERT-HPNE and PANC-1 cells for 24 h resulted in cell viability above 90% within the concentration range of 0-500 μg/ml. PMNP@FMs did not affect mouse survival and showed no apparent organ damage. In vivo fluorescence imaging and MRI revealed that PMNP@FMs accumulated highly in tumors and reached the peak 24 h post intravenous administration (relative MR signal: 1.35±0.01, fluorescence intensity: (1.20±0.25)×10 10), surpassing the peak observed in the control group (1.22±0.01, (3.87±0.50)×10 9;F values: 11.03-188.01, t values: 18.20, 5.64, all P<0.05), with hepatic metabolism being the primary route of clearance. Conclusion:PMNP@FMs demonstrate a potential for targeted pancreatic cancer fluorescence imaging and MRI, offering promising prospect for precise diagnosis of early-stage pancreatic cancer.
10.Safety Analysis of Coronary Artery Stent Rotational Atherectomy
Junshan LI ; Li YU ; Yaoming SONG ; Jianying MA ; Bo LUAN ; Mingduo ZHANG ; Yong DONG ; Jingjing RONG ; Hongwei PAN ; Changlu WANG
Chinese Circulation Journal 2024;39(7):669-675
Objectives:To analyze the safety of coronary artery stent rotational atherectomy due to stent underexpansion,in-stent restenosis,stent deformation,stent damage,and guide wire entrapment. Methods:A total of 19 patients with coronary artery disease who underwent coronary artery stent rotational atherectomy for the above reasons in 7 large heart centers in China from 2016 to 2022 were collected.Their baseline data,procedure process data,procedural complications,the occurrence of procedure-related adverse events(type 4a myocardial infarction,emergency coronary artery bypass grafting,and all-cause death)during hospitalization and major adverse cardiovascular events(MACE,including target vessel revascularization,stroke,all-cause death,and recurrent myocardial infarction)during post-discharge follow-up were retrospectively collected. Results:The mean age of the 19 patients was 70(64,73)years,and 13 patients were males.The mean left ventricular ejection fraction was(56.89±8.76)%.Radial artery approach was used in 13 patients,11 patients used 1 burr during the intervention period,6 patients used 2 burrs,and 2 patients used 3 burrs.The average times of burr passing through the lesion was(7.00±4.23)times.The surgical success rate was 100%,and the immediate lumen acquired area was(1.23±0.78)mm2.Drug-eluting stents were successfully implanted in all patients after spinning.Coronary slow blood flow occurred in 1 case after rotational grinding,which was improved after drug treatment.The burr was entrapmented in 3 cases and successfully pulled out after operation.No coronary artery perforation,coronary artery dissection,coronary artery spasm,emergency thoracotomy,or death occurred during the operation,and no procedure-related adverse events occurred during hospitalization.During 3 to 24 months of follow-up,1 patient underwent target vessel revascularization,and there were no MACE in other patients. Conclusions:Coronary artery stent rotational atherectomy in patients with stent underexpansion,in-stent restenosis,stent deformation,stent damage,and guide wire entrapment,is a feasible option,with a high surgical success rate and satisfactory safety.None of the patients experienced MACE during long-term follow-up.

Result Analysis
Print
Save
E-mail