1.Practice and exploration of a full-cycle medical record quality management model
Yan YUAN ; Yanbing LU ; Jianjun LU ; Ying XIONG
Modern Hospital 2025;25(10):1532-1534,1538
Objective To explore effective management methods for improving the efficiency of medical record quality control and enhancing medical record quality.Methods Based on a medical record quality control system,a full-cycle medical record quality management model was constructed,encompassing"pre-task reminders,real-time quality control during treatment,in-hospital process control,submission verification upon discharge,post-discharge terminal quality control,and re-verification af-ter archiving."Results Medical records achieved 100%quality control,and their quality significantly improved.The defect rate of medical record front pages and the delayed writing rate of surgical records in the hospital's discharged medical records continued to decline in the year before system implementation,the first year after implementation,and the second year after im-plementation.The 3-day retrieval rate of medical records increased significantly in the first year after implementation,with statis-tically significant differences in all three indicators(front page defect rate:x2=114.966,P<0.001;delayed writing rate of sur-gical records:x2=8 056.614,P<0.001;3-day retrieval rate:x2=798.201,P<0.001).Conclusion The full-cycle medi-cal record management model based on a quality control system can effectively improve medical record quality and enhance man-agement efficiency.Future efforts should focus on integrating continuously optimized AI technology to strengthen system perform-ance.
2.Quality analysis of medical record home pages based on DRG/DIP dual dimensions
Ying XIONG ; Ziyi XIN ; Junfeng LIU ; Yan YUAN ; Zhuochen LIN ; Jianjun LU
Modern Hospital 2025;25(10):1535-1538
Objective To analyze the quality of medical record home pages for discharged patients in a tertiary hospital in Guangzhou in 2023 based on the dual dimensions of Diagnosis-Related Groups(DRG)and Disease Intervention Program(DIP),and to provide a basis for improving the refinement of medical record home page quality management.Methods Dis-charge medical records from a tertiary general hospital in 2023 were selected.All medical records were grouped using DRG,while medical records under Guangzhou medical insurance and cross-province medical insurance implemented under DIP were simulated for DIP grouping.The writing defects in the discharge medical records were analyzed,as well as the DRG grouping,RW,and DIP standard scores of medical records with home page filling defects.Results Among 172 230 discharge medical records,171 786 were grouped into DRG,91 768 were grouped into DIP,and 91 604 were grouped into both DRG and DIP.A significant positive correlation was found between RW and DIP standard scores(r2=0.681,P<0.001).Among the 91 604 medical records grouped into both DRG and DIP,1 942(2.12%)had writing defects,including 837(0.91%)with home page defects.DRG groups with more home page defect records included NC15,HK2,EJ13,EB15,HJ13,and RE19.Conclusion Quality defects in medical record home pages impact the accuracy of DRG and DIP grouping.Systematic measures such as strengthening medical record writing training and establishing scientific reward and punishment mechanisms should be implemented to provide data sup-port for the further advancement of DRG/DIP payment reform.
3.Analyzing correlations of volume percentage and metabolism of brain region in patients with Alzheimer disease based on FDG PET/MR
Yinyan ZHU ; Yan ZHANG ; Gan HUANG ; Mei XIN ; Peizhe YUAN ; Yue WANG ; Liangrong WAN ; Cheng WANG ; Gang HUANG ; Jianjun LIU ; Chenpeng ZHANG
Chinese Journal of Medical Imaging Technology 2025;41(2):203-206
Objective To investigate correlations of the ratio of specific brain region volume to total brain volume(ratio%),standard uptake value(SUV)of specific brain region based on 18F-FDG PET/MR examination in Alzheimer disease(AD)patients,as well as the relationship between changes of these two.Methods Fifty AD patients were retrospectively collected.Based on FDG PET/MR,the ratio%and the mean SUV(SUVmean)of 40 specific brain regions were obtained,and the correlation between ratio%and SUVmean for each region were evaluated.According to a database of normal brains,Z-scores for ratio%and SUVmean were calculated to represent structural and functional changes in AD patients,and the correlation between these 2 Z-scores was assessed.Results Correlations were found between ratio%and SUVmean,also between Z-scores of these two parameters in 29 brain regions(r=0.288 to 0.778,all P<0.05).Among them 7 brain regions,i.e.bilateral middle temporal gyrus,right fusiform gyrus,right hippocampus,right precuneus,left lingual gyrus and right parahippocampal gyrus exhibited correlation coefficients greater than 0.6.Conclusion There were some relationships between brain structural and metabolic functions and their changes in AD patients showed on FDG PET/MR.
4.Association of white blood cell count with venous thromboembo-lism:a two-way Mendelian randomization study
Zhanli GUO ; Yuan WANG ; Lei ZHANG ; Jiayuan LI ; Ruoning LI ; Ying DONG ; Jianjun SUN
Chinese Journal of Clinical Pharmacology and Therapeutics 2025;30(4):446-455
AIM:To explore the causal association between the counts of five types of white blood cells—neutrophils,monocytes,eosinophils,baso-phils,and lymphocytes—and venous thromboem-bolism(VTE).METHODS:Mendelian randomization(MR)analysis method was used,with genetic vari-ants associated with the five types of white blood cells as instrumental variables,and venous throm-boembolism occurrence risk as the outcome vari-able,inverse variance-weighted(IVW)method was employed as the primary analysis method,with MR-Egger regression,weighted median(WM),sim-ple model,and weighted mode methods used as supplements,to analyze the causal association be-tween the counts of five types of white blood cells and VTE,followed by reverse MR analysis.RE-SULTS:Neutrophil and lymphocyte counts are caus-ally associated with the risk of VTE.For neutrophil count,the IVW estimate(OR=0.867,95%CI:0.761-0.981,P=0.031),MR-Egger estimate(OR=0.754,95%CI:0.571-0.996,P=0.048),weighted median es-timate(OR=0.846,95%CI:0.729-0.981,P=0.027),and weighted model estimate(OR=0.748,95%CI:0.595-0.942,P=0.014)were calculated.For lympho-cyte count,the IVW estimate(OR=0.838,95%CI:0.741-0.949,P=0.005)and weighted median esti-mate(OR=0.024,95%CI:0.718-0.977,P=0.024)were calculated.Reverse MR analysis showed a causal association between the risk of VTE and neu-trophil count,the IVW estimate(OR=0.989,95%CI:0.980-0.999,P=0.024).CONCLUSION:Neutrophil and lymphocyte counts are related to the risk of VTE,and decrease in neutrophil and lymphocyte numbers may increase the risk of VTE.VTE occur-rence risk is associated with neutrophil count,and reducing the risk of VTE occurrence may increase neutrophil count.Further research is needed to un-derstand the underlying biological mechanisms be-hind this relationship.
5.Practice and exploration of a full-cycle medical record quality management model
Yan YUAN ; Yanbing LU ; Jianjun LU ; Ying XIONG
Modern Hospital 2025;25(10):1532-1534,1538
Objective To explore effective management methods for improving the efficiency of medical record quality control and enhancing medical record quality.Methods Based on a medical record quality control system,a full-cycle medical record quality management model was constructed,encompassing"pre-task reminders,real-time quality control during treatment,in-hospital process control,submission verification upon discharge,post-discharge terminal quality control,and re-verification af-ter archiving."Results Medical records achieved 100%quality control,and their quality significantly improved.The defect rate of medical record front pages and the delayed writing rate of surgical records in the hospital's discharged medical records continued to decline in the year before system implementation,the first year after implementation,and the second year after im-plementation.The 3-day retrieval rate of medical records increased significantly in the first year after implementation,with statis-tically significant differences in all three indicators(front page defect rate:x2=114.966,P<0.001;delayed writing rate of sur-gical records:x2=8 056.614,P<0.001;3-day retrieval rate:x2=798.201,P<0.001).Conclusion The full-cycle medi-cal record management model based on a quality control system can effectively improve medical record quality and enhance man-agement efficiency.Future efforts should focus on integrating continuously optimized AI technology to strengthen system perform-ance.
6.Quality analysis of medical record home pages based on DRG/DIP dual dimensions
Ying XIONG ; Ziyi XIN ; Junfeng LIU ; Yan YUAN ; Zhuochen LIN ; Jianjun LU
Modern Hospital 2025;25(10):1535-1538
Objective To analyze the quality of medical record home pages for discharged patients in a tertiary hospital in Guangzhou in 2023 based on the dual dimensions of Diagnosis-Related Groups(DRG)and Disease Intervention Program(DIP),and to provide a basis for improving the refinement of medical record home page quality management.Methods Dis-charge medical records from a tertiary general hospital in 2023 were selected.All medical records were grouped using DRG,while medical records under Guangzhou medical insurance and cross-province medical insurance implemented under DIP were simulated for DIP grouping.The writing defects in the discharge medical records were analyzed,as well as the DRG grouping,RW,and DIP standard scores of medical records with home page filling defects.Results Among 172 230 discharge medical records,171 786 were grouped into DRG,91 768 were grouped into DIP,and 91 604 were grouped into both DRG and DIP.A significant positive correlation was found between RW and DIP standard scores(r2=0.681,P<0.001).Among the 91 604 medical records grouped into both DRG and DIP,1 942(2.12%)had writing defects,including 837(0.91%)with home page defects.DRG groups with more home page defect records included NC15,HK2,EJ13,EB15,HJ13,and RE19.Conclusion Quality defects in medical record home pages impact the accuracy of DRG and DIP grouping.Systematic measures such as strengthening medical record writing training and establishing scientific reward and punishment mechanisms should be implemented to provide data sup-port for the further advancement of DRG/DIP payment reform.
7.Buccal acupuncture combined with stellate ganglion block for sleep improvement after colorectal cancer surgery in the elderly:a clinical study
Xiaoqing ZHANG ; Jiuyi LI ; Di WU ; Jianjun OUYANG ; Qiling ZHANG ; Hongbao TAN ; Bo YUAN ; Qian ZHAO ; Yimei PENG
Chinese Journal of General Surgery 2025;34(3):528-535
Background and Aims:Elderly patients undergoing laparoscopic radical resection of colon cancer often experience decreased sleep quality,which may hinder postoperative recovery.Although pharmacological interventions are commonly used in clinical practice to improve postoperative sleep,conventional medications may lead to adverse effects such as delirium and dependence.This study aimed to evaluate the effect of a non-pharmacological intervention—buccal acupuncture combined with ultrasound-guided stellate ganglion block(SGB)—on postoperative sleep quality in elderly patients.Methods:A total of 60 elderly patients who underwent laparoscopic radical resection of colon cancer at the Forth Hospital of Changsha from February to August 2024 were enrolled.Using a random number table,the patients were divided into two groups:30 in the control group(SGB alone)and 30 in the study group(SGB combined with buccal acupuncture).Perioperative mean arterial pressure(MAP),heart rate(HR),postoperative visual analogue scale(VAS)scores,Pittsburgh Sleep Quality Index(PSQI)scores,and the incidence of adverse events were recorded and analyzed.Results:There were no statistically significant differences in baseline characteristics between the two groups(all P>0.05).The study group showed significantly lower intraoperative and postoperative HR and MAP compared to the control group(all P<0.05).VAS scores at 6,24,and 48 h postoperatively,as well as PSQI scores on postoperative days 1,3,and 5,were significantly lower in the study group(all P<0.05).Additionally,the incidence of drowsiness was significantly reduced(P<0.05).No significant differences were found between the two groups in terms of nausea,vomiting,or agitation(all P>0.05).Conclusion:The combination of buccal acupuncture and SGB during the perioperative period can effectively improve postoperative sleep quality,alleviate pain,and reduce adverse reactions in elderly patients undergoing laparoscopic radical resection of colon cancer.This safe and effective non-pharmacological intervention holds promising clinical application value.
8.Comparative study of different image-guided systems in positioning error and placement outside the target area of radiotherapy for cervical cancer
Li LIU ; Chengwei YE ; Jianjun YUAN ; Yingui LUO ; Zhiyao LUO ; Wei ZENG ; Ling LI ; Huan LIU ; Yan LIU ; Miao HE
China Medical Equipment 2025;22(4):18-22
Objective:To compare and analyze the differences in positioning errors and placement outside the target area between two different image-guided systems(Halcyon and Synergy)in radiotherapy for cervical cancer.Methods:The data of 40 patients with cervical cancer who received treatment in Dezhou People's Hospital from March 2023 to June 2023 were retrospectively selected.Each patient was treated respectively with Halcyon linear accelerator and Synergy linear accelerator,with 20 cases for each treatment method.All patients underwent cone beam computed tomography(CBCT)at kV level to conduct image scanning before radiotherapy,and the obtained CBCT images were matched with the positioned CT images by online.The registration results of left and right(x),head and foot(y)and front and back(z)of three translation direction,and pitch(Rx),rotation(Ry)and deflection(Rz)directions of rotation direction were respectively obtained.The margin of planning target volume(MPTV)was calculated according to positioning expansion formula.The differences of positioning errors and target area expansion between Halcyon and Synergy image-guided systems were compared and analyzed.Results:Halcyon and Synergy image-guided systems obtained respectively 479 and 447 sets of CBCT images.The translational errors of Halcyon image-guided system on x,y,and z directions were respectively(-0.03±0.21),(0.12±0.63)and(0.02±0.15)cm,and the rotational errors of that on Rx,Ry and Rz directions were respectively(0.38±1.26)°,(-0.40±1.02)°,and(0.07±1.07)°.The translational errors of Synergy image-guided system were respectively(-0.07±0.18),(0.08±0.49)and(0.11±0.22)cm on the three directions,and the rotational errors of that were respectively(0.28±1.29)°,(-0.29±1.29)° and(-0.16±1.20)°.The translational error values on the y direction of both image-guided system were larger than that on x and z directions,and the absolute values of the range of translational errors of them were basically within 5 mm.There were no statistically significant difference in the positioning errors of rotation on Rx and Ry directions between Halcyon and Synergy image-guided systems(P>0.05),while there was a statistically significant difference in the positioning error of rotation on Rz direction between them(t=-3.06,P<0.05).The MPTV values of Halcyon image-guided system on x,y and z directions were respectively 0.4,1.4 and 0.3 cm,and those of Synergy image-guided system were respectively 0.4,0.9 and 0.5 cm.The expansion boundary of target area of Halcyon image-guided system on the y direction was larger than that of Synergy image-guided system,and that on other directions were all less or equal to 0.5 cm.Conclusion:The MPTV values of Halcyon and Synergy image-guided systems can meet clinical requirements in radiotherapy.The positioning errors and the tube current of the scan of Halcyon image-guided system were larger than those of Synergy image-guided system,but the scanning time and treatment time of that were significantly lower than those of Synergy image-guided system.Different treatment systems can be selected individually for patients according to their different conditions.
9.Research progress of vacuum compression molding technology in pharmaceutical fields
Yixuan WANG ; Xin CHEN ; Lian HE ; Congcong ZHANG ; Peiya SHEN ; Yuan GAO ; Jianjun ZHANG
Journal of China Pharmaceutical University 2025;56(5):654-660
Vacuum compression molding (VCM) is a novel technology supporting the research and development of pharmaceutical solid dispersions. It is widely applied due to its precision and convenience in sample preparation. This technology integrates the principles of heating, melting, cooling, and vacuum compression to transform solid powders into shaped solids directly. By selecting different molds, temperatures, and pressures, researchers can prepare samples with diverse characteristics. This paper presents an overview of the equipment composition and working principles of VCM technology, demonstrating its distinct advantages in the formulation screening process of amorphous solid dispersions through comparative analysis with hot melt extrusion using case studies, and introduces its applications in the development of drug delivery systems and rheological characterization analysis, with a perspective on the future development of its functions.
10.Analysis of the Influence of Different Scanning Conditions of Medical Linear Accelerator CBCT on Image Quality.
Li LIU ; Chengwei YE ; Jianjun YUAN ; Yingui LUO ; Zhiyao LUO ; Wei ZENG ; Ling LI ; Huan LIU ; Yan LIU
Chinese Journal of Medical Instrumentation 2025;49(2):176-180
OBJECTIVE:
To investigate the influence of different scanning conditions on the image quality of medical electron accelerator cone-beam computed tomography (CBCT) and provide a reference for the selection of scanning conditions for different body parts. Methods Set different scanning conditions, the Catphan 503 phantom was scanned using CBCT parameters to analyze the influence of spatial resolution, noise, uniformity, spatial geometric accuracy, and low-contrast resolution on the image quality of CBCT.
RESULTS:
For the head, chest, and abdomen, with the increase in scanning parameter values, the noise value decreased by 47.4%, 26.1%, and 51.3% respectively, and the uniformity values decreased by 30.2%, 26.6%, and 47.9% respectively. The low-contrast resolution values decreased by 50.6%, 34.2%, and 12.0%. The influence of different scanning conditions on spatial geometric accuracy and spatial resolution is not significant.
CONCLUSION
Different scanning parameters have a certain influence on the image quality of medical electron accelerator CBCT. Lower scanning parameters can be selected based on individual patients to reduce the additional radiation dose, providing a reference for the safe application of CBCT image guidance in radiotherapy.
Cone-Beam Computed Tomography/instrumentation*
;
Phantoms, Imaging
;
Particle Accelerators

Result Analysis
Print
Save
E-mail