1.Health risk assessment of fluoride and trichloromethane in drinking water in rural schools in Guizhou Province
JIAN Zihai, ZHANG Jianhua, SU Minmin, CHEN Xuanhao, YUAN Minlan, YANG Dan, CHEN Gang
Chinese Journal of School Health 2025;46(1):134-137
Objective:
To analyze the distribution characteristics of fluoride and trichloromethane in drinking water in rural schools in Guizhou Province and assess their health risks, so as to provide a scientific basis for ensuring the safety of drinking water in rural schools.
Methods:
During the dry season (March to May) and wet season (July to September) of 2020 to 2022, 788 rural primary and secondary schools in agricultural counties (districts) in Guizhou Province were selected for investigation by using a direct sampling method. A total of 1 566 drinking water samples were collected from these schools, and the mass concentrations of fluoride and trichloromethane in the water samples were detected. The Mann-Whitney U test was used for intergroup comparison, and a health risk assessment model was employed to evaluate the health risks of students oral intake of fluoride and trichloromethane.
Results:
From 2020 to 2022, the mass concentrations of fluoride and trichloromethane in the drinking water of rural schools in Guizhou Province all met the standards, and the ranges were no detection to 0.99 mg/L and (no detection to 0.06)×10 -3 mg/L, respectively. The mass concentrations of fluoride in dry and wet seasons were 0.05(0.05,0.10), 0.05(0.05,0.10) mg/L, the mass concentrations of trichloromethane were [0.02(0.02,1.00)]×10 -3 , [0.02(0.02,1.00)]×10 -3 mg/L, the mass concentrations of fluoride in factory water and terminal water were 0.05(0.05,0.05), 0.05(0.05,0.10) mg/L, and the differences were not statistically significant ( Z=-0.04, -0.88, - 0.98 , P >0.05). There was a statistically significant difference in the mass concentration of trichloromethane between factory water and peripheral water [0.02(0.02,0.02)×10 -3 , 0.02(0.02,1.05)×10 -3 mg/L]( Z=-2.16, P < 0.05 ). The non-carcinogenic risk assessment values for students oral exposure to fluoride and trichloromethane were in the range of 0.01(0.01,0.03)-0.03(0.03,0.06) and [0.26( 0.26 ,14.54)]×10 -4 -[0.52(0.52,48.62)]×10 -4 , respectively, all of which were at acceptable levels; the carcinogenic risk assessment values for oral exposure to trichloromethane were in the range of [0.08(0.08, 4.51 )]×10 -7 -[0.16(0.16,15.07)]×10 -7 , indicating a low risk.
Conclusions
The health risks of students expore to fluoride and trichloromethane in drinking water in rural schools of Guizhou Province are low. It is necessary to strengthen the standardized management of disinfection in some rural drinking water projects and the monitoring of fluoride in water sources to reduce the exposure risk to children.
2.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
3.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
4.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
5.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
6.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
7.Expert consensus on whole-process management of drug traceability codes in medical institutions of Sichuan province
Qianghong PU ; Yilan HUANG ; Yilong LIU ; Xiaosi LI ; Lin YUAN ; Jiangping YU ; Bo JIANG ; Peng ZHANG ; Qiang SU ; Liangming ZHANG ; Jie WAN ; Li CHEN ; Qian JIANG ; Jianhua FAN ; Yong YANG
China Pharmacy 2025;36(24):3017-3022
OBJECTIVE To provide standardized whole-process guidance on drug traceability codes for medical institutions in Sichuan province, ensuring medication safety and compliance with medical insurance supervision requirements. METHODS Based on evidence-based principles and expert consensus, Expert Consensus on Whole-process Management of Drug Traceability Codes in Medical Institutions of Sichuan Province (hereinafter referred to as the Consensus) was formulated through systematic literature review, field investigations, establishment of a multidisciplinary expert committee and multiple rounds of questionnare consultation via the modified Delphi method, and finalized through consensus meetings. RESULTS & CONCLUSIONS The Consensus clarifies key operating procedures for code verification, code assignment and code return, whole-process operational standards for drug warehouse acceptance and storage, drug warehouse outbound delivery and pharmacy acceptance check, drug distribution and dispensing in pharmacy and intravenous admixture center, medication administration in nursing units and examination departments, as well as drug return process. Key recommendations are proposed such as improving the core functions of the drug traceability system, unifying the hospital-wide traceability code database, strengthening the management of traceability codes for backup medications, establishing a management organization and institutional framework, and optimizing the architectural design and data governance requirements of the drug traceability system. The release of the Consensus will provide scientific, standardized and implementable practical guidelines for medical institutions of Sichuan province, helping to improve closed-loop management of the drug traceability system, strengthen medication safety and fulfil medical insurance fund supervision.
8.Impact of 177Lu-DOTATATE therapy on radiation exposure of ward healthcare staff and accompanying persons
Xuesong SU ; Jinming ZHANG ; Jianhua GENG ; Yingmao CHEN ; Gaofeng LI ; Xuejuan WANG
Chinese Journal of Radiological Health 2024;33(5):510-516
Objective To investigate air radioactivity contamination, surface contamination, ambient dose equivalent rates, and radiation doses to individuals in the treatment room during 177Lu-DOTATATE therapy. Methods A ward for 177Lu-DOTATATE therapy was selected in the nuclear medicine department of a general hospital. Air and surface radioactivity samples were collected before and after therapy for four patients. Ambient dose equivalent rates were measured around the four patients following the initiation of 177Lu-DOTATATE therapy. Measurements were taken at distances of 0.1, 0.3, 0.5, and 1−4 m (with 0.5 m intervals) from the right lateral midsection of the patient’s torso. The measurement time points included 5, 15, and 30 min after initiation of administration, as well as 0−4 h (with 1 h intervals), 24 h, and 48 h post-administration. Radiation exposure doses for personnel at different distances from the patients were calculated for each time interval. Results The results of radioactive aerosol detection for all four patients during and after the administration of 177Lu-DOTATATE were similar to those before administration. Surface contamination was not detected at the measurement locations except for patient number 2. The ambient dose equivalent rates increased with increasing injection dose during the administration. However, the ambient dose equivalent rates decreased significantly within one hour after administration. At the end of the administration, the average ambient dose equivalent rate at a distance of one meter for the four patients was 42.931 μSv/h. From the start of administration to four hours post-administration, personnel maintaining a distance of one meter from the patient received a total radiation dose of 167.64 μSv. Conclusion Air radioactivity contamination does not occur during 177Lu-DOTATATE therapy. However, measures should be taken before the commencement of therapy to address potential surface contamination. Both accompanying persons and healthcare staff receive radiation doses below the stipulated dose constraints throughout the treatment process. Therefore, it is necessary to implement appropriate measures to minimize the radiation exposure of healthcare staff.
9.Impact of 177Lu-DOTATATE therapy on radiation exposure of ward healthcare staff and accompanying persons
Xuesong SU ; Jinming ZHANG ; Jianhua GENG ; Yingmao CHEN ; Gaofeng LI ; Xuejuan WANG
Chinese Journal of Radiological Health 2024;33(5):510-516
Objective To investigate air radioactivity contamination, surface contamination, ambient dose equivalent rates, and radiation doses to individuals in the treatment room during 177Lu-DOTATATE therapy. Methods A ward for 177Lu-DOTATATE therapy was selected in the nuclear medicine department of a general hospital. Air and surface radioactivity samples were collected before and after therapy for four patients. Ambient dose equivalent rates were measured around the four patients following the initiation of 177Lu-DOTATATE therapy. Measurements were taken at distances of 0.1, 0.3, 0.5, and 1−4 m (with 0.5 m intervals) from the right lateral midsection of the patient’s torso. The measurement time points included 5, 15, and 30 min after initiation of administration, as well as 0−4 h (with 1 h intervals), 24 h, and 48 h post-administration. Radiation exposure doses for personnel at different distances from the patients were calculated for each time interval. Results The results of radioactive aerosol detection for all four patients during and after the administration of 177Lu-DOTATATE were similar to those before administration. Surface contamination was not detected at the measurement locations except for patient number 2. The ambient dose equivalent rates increased with increasing injection dose during the administration. However, the ambient dose equivalent rates decreased significantly within one hour after administration. At the end of the administration, the average ambient dose equivalent rate at a distance of one meter for the four patients was 42.931 μSv/h. From the start of administration to four hours post-administration, personnel maintaining a distance of one meter from the patient received a total radiation dose of 167.64 μSv. Conclusion Air radioactivity contamination does not occur during 177Lu-DOTATATE therapy. However, measures should be taken before the commencement of therapy to address potential surface contamination. Both accompanying persons and healthcare staff receive radiation doses below the stipulated dose constraints throughout the treatment process. Therefore, it is necessary to implement appropriate measures to minimize the radiation exposure of healthcare staff.
10.Visualization of nasal powder distribution using biomimetic human nasal cavity model.
Jiawen SU ; Yan LIU ; Hongyu SUN ; Abid NAEEM ; Huipeng XU ; Yue QU ; Caifen WANG ; Zeru LI ; Jianhua LU ; Lulu WANG ; Xiaofeng WANG ; Jie WU ; Lixin SUN ; Jiwen ZHANG ; Zhigang WANG ; Rui YANG ; Li WU
Acta Pharmaceutica Sinica B 2024;14(1):392-404
Nasal drug delivery efficiency is highly dependent on the position in which the drug is deposited in the nasal cavity. However, no reliable method is currently available to assess its impact on delivery performance. In this study, a biomimetic nasal model based on three-dimensional (3D) reconstruction and three-dimensional printing (3DP) technology was developed for visualizing the deposition of drug powders in the nasal cavity. The results showed significant differences in cavity area and volume and powder distribution in the anterior part of the biomimetic nasal model of Chinese males and females. The nasal cavity model was modified with dimethicone and validated to be suitable for the deposition test. The experimental device produced the most satisfactory results with five spray times. Furthermore, particle sizes and spray angles were found to significantly affect the experimental device's performance and alter drug distribution, respectively. Additionally, mometasone furoate (MF) nasal spray (NS) distribution patterns were investigated in a goat nasal cavity model and three male goat noses, confirming the in vitro and in vivo correlation. In conclusion, the developed human nasal structure biomimetic device has the potential to be a valuable tool for assessing nasal drug delivery system deposition and distribution.


Result Analysis
Print
Save
E-mail