1.Standardization Challenges in Outcome Evaluation Systems of Animal Experiments and Considerations for Core Outcome Set Construction Strategies
Qingyong ZHENG ; Yongjia ZHOU ; Tengfei LI ; Jianguo XU ; Chen TIAN ; Hui LIU ; Min TIAN ; Ziyu ZHOU ; Caihua XU ; Yating CUI ; Junfei WANG ; Jinhui TIAN
Laboratory Animal and Comparative Medicine 2026;46(1):138-148
Animal experimentation constitutes a critical link between basic research and clinical application, making its research quality and translational efficiency paramount. Although considerable progress has been made in standardizing operational procedures and ethical guidelines, the standardization of outcome evaluation systems has significantly lagged, creating a key bottleneck that constrains the quality of biomedical research and evidence synthesis. This deficiency is manifested by pronounced heterogeneity in outcome selection across similar studies, incomplete methodological reporting, and disparate criteria for result interpretation, which severely impairs the comparability of findings and the evidence integration. To cope with this challenge, this paper systematically introduces a mature methodological tool from clinical research–the core outcome set (COS)–and explores its construction strategies and application potential in the field of animal experimentation. Given the extensive diversity of animal experiments, a pragmatic strategy of "focusing on key areas, implementing phased pilots, and promoting gradual expansion" should be adopted. This approach prioritizes the development of domain-specific COS for disease areas characterized by high research volume, urgent translational needs, and well-established animal models. A multi-source integration pathway for COS development is detailed, comprising systematic literature searches, methodological appraisals, and expert consensus, with the feasibility of leveraging artificial intelligence (AI) to enhance efficiency also being examined. The development and promotion of such COS are not intended to restrict scientific exploration; rather, they aim to establish a new, tiered evaluation paradigm consisting of "core outcomes" (mandatory), "recommended outcomes" (encouraged), and "exploratory outcomes" (optional). This framework is expected not only to enhance research quality through standardization and to adhere to the "3R" principles but also to accelerate the accumulation of high-quality evidence. This, in turn, provides a solid foundation for higher-level evidence synthesis, ultimately facilitating the effective translation of basic research findings into clinical practice and providing an essential methodological framework for scientific advancement in relevant disciplines.
2.Impact of suture configuration and fixation type on biomechanical strength of rotator cuff repair:A factorial design study
Yinzhe CUI ; Zheng YAN ; Jia MA ; Zhefeng JIN ; Jiawen ZHAN ; Minshan FENG ; Guangwei LIU ; Jie YU ; Xu WEI ; Jiangtao SI ; Minghui ZHUANG ; Tao HAN ; Jianguo LI ; ZHANGKAIRUI ; Liguo ZHU
Chinese Journal of Sports Medicine 2025;44(9):729-737
Objective To explore the impact of suture configuration and fixation type on the biome-chanical strength of rotator cuff repair,using a factorial design study.Methods Sixteen fresh-frozen porcine shoulder samples were randomized into an anchorless double-row suture bridge transosseous su-tures(DS)group,an anchored double-row suture bridge transosseous-equivalent(DE)group,an an-chorless X-BOX construct transosseous sutures(XS)group,and an anchored X-BOX construct transos-seous-equivalent(XE)group,each of four,according to suture configuration(double-row suture bridge,traditional X-BOX construct)and fixation type(suture anchors,transosseous sutures).Then,their fatigue resistance(first-cycle excursion,gap length difference ratio,and the percentage of ex-posed footprints)and the failure strength(the maximum failure load and the re-tear type)were mea-sured using a biomechanical material testing machine.Results Different suture configurations affected failure strength(F=39.559,P<0.001),with the double-row suture bridge groups(693.07±58.35 N,746.76±138.57 N)showing significantly higher failure strength,compared to the traditional X-BOX groups(462.90±18.91 N,421.43±90.76 N).However,the fixation type did not significantly im-pact failure strength(F=1.161,P=0.302).Moreover,the suture configuration influenced the gap differ-ence ratio(F=7.781,P=0.016),but had no significant correlation with other fatigue resistance indica-tors(P>0.05).Meanwhile,failure strength and fatigue resistance were not correlated with fixation type,and the interaction between suture and fixation type(P>0.05).The incidence of failure types for the four suture configurations was as follows:Type I tendon tear:XS>XE>DS=DE;type II tendon tear:DS>XE>XS=DE;fixing material-related failure:DE>DS=XE=XS.Conclusion The failure strength and gap formation ratio in rotator cuff repair under fatigue loading are influenced by suture configuration,whereas no significant association has been observed with respect to fixation method,whether using transosseous sutures or suture anchors.
3.Phase Ⅲ, multicenter, randomized comparative study of LY01005 and Zoladex ? for patients with premenopausal breast cancer
Xiying SHAO ; Qingyuan ZHANG ; Zhaofeng NIU ; Man LI ; Jingfen WANG ; Zhanhong CHEN ; Ruizhen LUO ; Guangdong QIAO ; Jianguo WANG ; Liyuan QIAN ; Ronghua YANG ; Zhendong CHEN ; Jian WANG ; Yumin YAO ; Jianghua OU ; Tao SUN ; Qiao CHENG ; Yongsheng WANG ; Jian HUANG ; Hongying ZHAO ; Wuyun SU ; Zhong OUYANG ; Yu DING ; Lilin CHEN ; Sumei YANG ; Mengsheng CUI ; Aimin ZANG ; Enxiang ZHOU ; Peizhi FAN ; Jing ZHANG ; Qiang LIU ; Yuee TENG ; Hui LI ; Jianyun NIE ; Jin YANG ; Xiaojia WANG ; Zefei JIANG
Chinese Journal of Oncology 2025;47(4):340-348
Background:To compare the efficacy and safety of monthly administrations of gonadotropin releasing hormone (GnRH) agonists LY01005 and Zoladex ? in Chinese patients with premenopausal breast cancer. Methods:From October 2020 to November 2021, 188 premenopausal breast cancer patients were enrolled in 34 hospitals and randomized 1:1 to receive either LY01005 or Zoladex ? every 28 days for a total of three injections. All patients concomitantly received oral tamoxifen (TAM). The primary efficacy endpoint was cumulative probability of maintaining menopausal level [oestradiol (E2) ≤30 pg/ml] from day 29 to day 85. The second efficacy endpoint included changes in E2, luteinizing hormone (LH), and follicle-stimulating hormone (FSH) compared with the baseline. Pharmacokinetics (PK), pharmacodynamics (PD), and safety were analyzed. The study also evaluated the pharmacokinetic and pharmacodynamic characteristics of LY01005. Results:A total of 188 patients were randomised and 187 patients received either LY01005 or Zoladex ?. Cumulative probabilities of maintaining menopausal level (E2≤30 pg/ml) from day 29 to day 85 were 93.1% for LY01005 and 86.3% for Zoladex ?. The between-group difference was 6.8% (95% CI: -2.3%, 15.9%) and primary efficacy in the LY01005 group was not inferior to that in the Zoladex ? group. Changes in E2, LH, and FSH levels compared with the baseline were equivalent between the two groups (E2: 89.34% to 90.23% vs. 82.11% to 85.02%; LH: 88.89% to 95.52% vs. 89.70% to 97.02%; FSH: 75.36% to 80.85% vs.73.07% to 80.24%, respectively). After three consecutive doses of LY01005, the LH and FSH levels of the subjects showed a transient increase after the first dose, reached a peak on the second day and then started to decrease. The LH and FSH reached a lower level and remained at or below that level until the 85th day. Both treatments were well-tolerated. Conclusion:LY01005 is as effective as Zoladex ? in suppressing E2 to menopausal levels in Chinese patients with premenopausal breast cancer, with a similar safety profile.
4.Impact of suture configuration and fixation type on biomechanical strength of rotator cuff repair:A factorial design study
Yinzhe CUI ; Zheng YAN ; Jia MA ; Zhefeng JIN ; Jiawen ZHAN ; Minshan FENG ; Guangwei LIU ; Jie YU ; Xu WEI ; Jiangtao SI ; Minghui ZHUANG ; Tao HAN ; Jianguo LI ; ZHANGKAIRUI ; Liguo ZHU
Chinese Journal of Sports Medicine 2025;44(9):729-737
Objective To explore the impact of suture configuration and fixation type on the biome-chanical strength of rotator cuff repair,using a factorial design study.Methods Sixteen fresh-frozen porcine shoulder samples were randomized into an anchorless double-row suture bridge transosseous su-tures(DS)group,an anchored double-row suture bridge transosseous-equivalent(DE)group,an an-chorless X-BOX construct transosseous sutures(XS)group,and an anchored X-BOX construct transos-seous-equivalent(XE)group,each of four,according to suture configuration(double-row suture bridge,traditional X-BOX construct)and fixation type(suture anchors,transosseous sutures).Then,their fatigue resistance(first-cycle excursion,gap length difference ratio,and the percentage of ex-posed footprints)and the failure strength(the maximum failure load and the re-tear type)were mea-sured using a biomechanical material testing machine.Results Different suture configurations affected failure strength(F=39.559,P<0.001),with the double-row suture bridge groups(693.07±58.35 N,746.76±138.57 N)showing significantly higher failure strength,compared to the traditional X-BOX groups(462.90±18.91 N,421.43±90.76 N).However,the fixation type did not significantly im-pact failure strength(F=1.161,P=0.302).Moreover,the suture configuration influenced the gap differ-ence ratio(F=7.781,P=0.016),but had no significant correlation with other fatigue resistance indica-tors(P>0.05).Meanwhile,failure strength and fatigue resistance were not correlated with fixation type,and the interaction between suture and fixation type(P>0.05).The incidence of failure types for the four suture configurations was as follows:Type I tendon tear:XS>XE>DS=DE;type II tendon tear:DS>XE>XS=DE;fixing material-related failure:DE>DS=XE=XS.Conclusion The failure strength and gap formation ratio in rotator cuff repair under fatigue loading are influenced by suture configuration,whereas no significant association has been observed with respect to fixation method,whether using transosseous sutures or suture anchors.
5.Phase Ⅲ, multicenter, randomized comparative study of LY01005 and Zoladex ? for patients with premenopausal breast cancer
Xiying SHAO ; Qingyuan ZHANG ; Zhaofeng NIU ; Man LI ; Jingfen WANG ; Zhanhong CHEN ; Ruizhen LUO ; Guangdong QIAO ; Jianguo WANG ; Liyuan QIAN ; Ronghua YANG ; Zhendong CHEN ; Jian WANG ; Yumin YAO ; Jianghua OU ; Tao SUN ; Qiao CHENG ; Yongsheng WANG ; Jian HUANG ; Hongying ZHAO ; Wuyun SU ; Zhong OUYANG ; Yu DING ; Lilin CHEN ; Sumei YANG ; Mengsheng CUI ; Aimin ZANG ; Enxiang ZHOU ; Peizhi FAN ; Jing ZHANG ; Qiang LIU ; Yuee TENG ; Hui LI ; Jianyun NIE ; Jin YANG ; Xiaojia WANG ; Zefei JIANG
Chinese Journal of Oncology 2025;47(4):340-348
Background:To compare the efficacy and safety of monthly administrations of gonadotropin releasing hormone (GnRH) agonists LY01005 and Zoladex ? in Chinese patients with premenopausal breast cancer. Methods:From October 2020 to November 2021, 188 premenopausal breast cancer patients were enrolled in 34 hospitals and randomized 1:1 to receive either LY01005 or Zoladex ? every 28 days for a total of three injections. All patients concomitantly received oral tamoxifen (TAM). The primary efficacy endpoint was cumulative probability of maintaining menopausal level [oestradiol (E2) ≤30 pg/ml] from day 29 to day 85. The second efficacy endpoint included changes in E2, luteinizing hormone (LH), and follicle-stimulating hormone (FSH) compared with the baseline. Pharmacokinetics (PK), pharmacodynamics (PD), and safety were analyzed. The study also evaluated the pharmacokinetic and pharmacodynamic characteristics of LY01005. Results:A total of 188 patients were randomised and 187 patients received either LY01005 or Zoladex ?. Cumulative probabilities of maintaining menopausal level (E2≤30 pg/ml) from day 29 to day 85 were 93.1% for LY01005 and 86.3% for Zoladex ?. The between-group difference was 6.8% (95% CI: -2.3%, 15.9%) and primary efficacy in the LY01005 group was not inferior to that in the Zoladex ? group. Changes in E2, LH, and FSH levels compared with the baseline were equivalent between the two groups (E2: 89.34% to 90.23% vs. 82.11% to 85.02%; LH: 88.89% to 95.52% vs. 89.70% to 97.02%; FSH: 75.36% to 80.85% vs.73.07% to 80.24%, respectively). After three consecutive doses of LY01005, the LH and FSH levels of the subjects showed a transient increase after the first dose, reached a peak on the second day and then started to decrease. The LH and FSH reached a lower level and remained at or below that level until the 85th day. Both treatments were well-tolerated. Conclusion:LY01005 is as effective as Zoladex ? in suppressing E2 to menopausal levels in Chinese patients with premenopausal breast cancer, with a similar safety profile.
6.Pathogen spectrum of hospitalized severe acute respiratory infection cases in a sentinel hospital in Tongzhou District of Beijing from 2019 to 2022
Lin ZOU ; Chong ZHANG ; Ling TONG ; Jianming ZHANG ; Jianguo WANG ; Fang WANG ; Xiang GAO ; Shujuan CUI ; Daitao ZHANG
Chinese Journal of Microbiology and Immunology 2024;44(7):596-600
Objective:To investigate the pathogen spectrum and the epidemiological characteristics of hospitalized severe acute respiratory tract infection (SARI) cases in a sentinel hospital in Tongzhou District of Beijing from 2019 to 2022, and provide reference for scientific prevention and control of SARI.Methods:This study enrolled SARI patients in the Beijing Luhe Hospital from January 2019 to December 2022. Nasopharyngeal swabs or respiratory secretions of the patients were collected and analyzed by quantitative real-time PCR to detect the pathogens and their types. The epidemiological and clinical characteristics of the cases were analyzed.Results:In this study, 1 124 SARI cases were enrolled, of which 379 were positive for respiratory pathogens with a detection rate of 33.72%. Most of the SARI cases were positive for bacteria pathogens, and the detection rates of Mycoplasma pneumoniae, Streptococcus pneumoniae, and Stenotrophomonas maltophilia were high. Influenza A virus, parainfluenza virus, and respiratory syncytial virus were the main viral pathogens detected in the cases. There were significant differences in the number of cases and the detection rate of respiratory pathogens among different age groups (χ 2=555, P=0.000 1). The predominant pathogens in different years were different. Mycoplasma pneumoniae [27.27% (51/187)] and influenza A virus [17.65% (33/187), ] were the predominant pathogens in 2019; parainfluenza virus [16.67% (10/60)], Mycoplasma pneumoniae [11.67% (7/60)], and Haemophilus influenzae [11.67% (7/60)] were the predominant pathogens in 2020; Stenotrophomonas maltophilia [24.39% (20/82)] and respiratory syncytial virus [19.51% (16/82)] were the predominant pathogens in 2021; Stenotrophomonas maltophilia [20% (10/50)] and parainfluenza virus [12% (6/50)] were the predominant pathogens in 2022. Conclusions:Most of the SARI cases in Tongzhou district of Beijing from 2019 to 2022 are caused by bacteria. More attention should be paid to the prevalence of Stenotrophomonas maltophilia and Mycoplasma pneumoniae, as well as the prevalence of respiratory syncytial virus, parainfluenza virus, and influenza A virus. The predominant pathogens change every year from 2019 to 2022. Therefore, the prevention and control strategies should be made accordingly. This study provides basis data for the national respiratory multipathogen surveillance program.
7.Epidemiological characteristics of hand, foot, and mouth disease and its correlation with meteorological factors in Minhang District, Shanghai from 2014 to 2018
Xia ZHAO ; Jinsong CUI ; Yi ZHANG ; Jianguo TAN
Shanghai Journal of Preventive Medicine 2022;34(3):219-222
Objective To study the epidemiological features of hand, foot, and mouth disease (HFMD) in Minhang District of Shanghai and to explore the possible effects of meteorological factors on the onset of HFMD, aiming to provide a reference for the prevention and control of HFMD. Methods The incidence data of HFMD in Minhang District from 2014 to 2018 were collected for descriptive analysis. The data of meteorological factors that might affect HFMD were analyzed by Pearson analysis and multiple linear stepwise regression. Results The average incidence rate of HFMD in Minhang District from 2014 to 2018 was 271.51 per 100 000. The incidence of Huacao, Pujiang and Maqiao community were the highest. The incidence of HFMD in males was higher than in females and the 0‒5 age group had the largest number of cases, mainly in scattered children and children in kindergartens. The results of multiple linear stepwise regression analysis showed that the incidence of HFMD was negatively correlated with the weekly average air pressure ( b =-4.32, P =0.004), and was positively correlated with the weekly minimum temperature ( b =2.62, P =0.040) and the weekly average relative humidity ( b =1.71, P =0.010). The correlation with weekly average temperature, weekly maximum temperature, weekly precipitation, weekly average air pressure and weekly average water vapor pressure was not significant. Conclusion Meteorological factors in Minhang District of Shanghai are closely related to the occurrence of HFMD. Comprehensive measures should be taken to prevent and control HFMD.
8.Homogenization and optimization strategy for standard process of intensity-modulated radiotherapy for nasopharyngeal carcinoma
Guangrong YANG ; Bangyu LUO ; Yi WU ; Yajun WU ; Jindong QIAN ; Lirong ZHAO ; Xianlan ZHAO ; Ying ZHU ; Tianxiang CUI ; Liangzhi ZHONG ; Yibing ZHOU ; Xiaoping LI ; Enqiang LIU ; Jianguo SUN
Chinese Journal of Radiation Oncology 2020;29(8):619-624
Radiotherapy is the most common treatment for nasopharyngeal carcinoma, and the radiotherapy technique is essential for the prognosis of nasopharyngeal carcinoma. Due to the complexity of the structure of the intensity-modulated device and the accuracy of the clinical requirements of radiotherapy, it is inevitable that higher requirements will be imposed on the process of intensity-modulated radiotherapy. Currently, gaps exist in the radiotherapy equipment and personnel qualification among radiotherapy units, and thus the homogenization in the radiotherapy remains to be strengthened in China. With the application of radiotherapy information management system, digital medicine and artificial intelligence technologies in the field of radiotherapy, the original process fails to meet the application needs of the new precise radiotherapy technology. Therefore, this process is designed based on the existing radiotherapy procedures for nasopharyngeal carcinoma in combination with the latest developments in the field of radiotherapy, aiming to establish a novel standard process recommendation, ensuring the standardization and homogenization of radiotherapy and achieve the individualized intensity-modulated radiotherapy for nasopharyngeal carcinoma patients.
9.Recommendation on global prevention and control of coronavirus disease 2019 in the early stage
YI Heya ; LI Chuan ; WANG Peng ; CUI Zengwei ; XIA Jianguo ; DAI Shuyu ; LIANG Xiaofeng
Journal of Preventive Medicine 2020;32(4):325-329
Severe acute respiratory syndrome coronavirus(SARS-CoV-2)is highly infectious and people are generally susceptible to it. In this article,we reviewed current research into the epidemiological characteristics of coronavirus disease 2019(COVID-19),introduced China's effective prevention and control experience,preliminarily summarized the phased Results of China's fight against the COVID-19,and reviewed the early measures taken by Singapore,Japan,Italy,Iran and South Korea. We recommended China’s prevention and control measures in response to COVID-19 to the world;appealed to pay attention to non-drug interventions,to strengthen the cooperation and sharing of COVID-19 epidemic data and research,to improve the global ability in respond to public health emergencies,and to reduce the impact of COVID-2019 on the sustainable development of economy and society.
10.Research progress on the mechanism of radiation damage and prevention of neutron radiation
Lei LIU ; Jianguo CUI ; Jianming CAI
Chinese Journal of Radiological Medicine and Protection 2017;37(8):635-640
With the strengthening of nuclear weapon development and the expanding of neutron application in economic area,the injury accidents of neutron radiation are happening from time to time.Neutron exposure,with high linear energy transfer,has high casualty rate,severe symptom and poor prognosis.In comparison with low-LET radiation damage,neutron irradiation induced injuries are more difficult to rescue.This review focused on the recent research progresses of radiation effects,intrinsic mechanisms and clinical prevention measures of neutron radiation,and to provide a theoretical clue for establishing an effective prevention protocol of neutron radiation damage.


Result Analysis
Print
Save
E-mail