1.Principles, technical specifications, and clinical application of lung watershed topography map 2.0: A thoracic surgery expert consensus (2024 version)
Wenzhao ZHONG ; Fan YANG ; Jian HU ; Fengwei TAN ; Xuening YANG ; Qiang PU ; Wei JIANG ; Deping ZHAO ; Hecheng LI ; Xiaolong YAN ; Lijie TAN ; Junqiang FAN ; Guibin QIAO ; Qiang NIE ; Mingqiang KANG ; Weibing WU ; Hao ZHANG ; Zhigang LI ; Zihao CHEN ; Shugeng GAO ; Yilong WU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(02):141-152
With the widespread adoption of low-dose CT screening and the extensive application of high-resolution CT, the detection rate of sub-centimeter lung nodules has significantly increased. How to scientifically manage these nodules while avoiding overtreatment and diagnostic delays has become an important clinical issue. Among them, lung nodules with a consolidation tumor ratio less than 0.25, dominated by ground-glass shadows, are particularly worthy of attention. The therapeutic challenge for this group is how to achieve precise and complete resection of nodules during surgery while maximizing the preservation of the patient's lung function. The "watershed topography map" is a new technology based on big data and artificial intelligence algorithms. This method uses Dicom data from conventional dose CT scans, combined with microscopic (22-24 levels) capillary network anatomical watershed features, to generate high-precision simulated natural segmentation planes of lung sub-segments through specific textures and forms. This technology forms fluorescent watershed boundaries on the lung surface, which highly fit the actual lung anatomical structure. By analyzing the adjacent relationship between the nodule and the watershed boundary, real-time, visually accurate positioning of the nodule can be achieved. This innovative technology provides a new solution for the intraoperative positioning and resection of lung nodules. This consensus was led by four major domestic societies, jointly with expert teams in related fields, oriented to clinical practical needs, referring to domestic and foreign guidelines and consensus, and finally formed after multiple rounds of consultation, discussion, and voting. The main content covers the theoretical basis of the "watershed topography map" technology, indications, operation procedures, surgical planning details, and postoperative evaluation standards, aiming to provide scientific guidance and exploration directions for clinical peers who are currently or plan to carry out lung nodule resection using the fluorescent microscope watershed analysis method.
2.Construction and validation of a prediction model for central lymph node metastasis of papillary thyroid carcinoma based on contrast-enhanced venous phase CT radiomics
Xingyun HE ; Chen LIU ; Junze DU ; Qian LI ; Kang CHEN ; Rui FAN ; Jian WANG
Journal of Army Medical University 2025;47(12):1367-1375
Objective To construct and validate an interpretable machine learning model integrating contrast-enhanced venous phase CT radiomics and clinical features for preoperative prediction of central lymph node metastasis(CLNM)of papillary thyroid carcinoma(PTC).Methods A case-control study was conducted on 243 histologically confirmed PTC patients.Among them,196 patients from the First Affiliated Hospital of Army Medical University were randomly allocated into a training set(n=137)and an internal validation set(n=59)at a 7:3 ratio,while the left 47 patients from No.958 Hospital of PLA Army were assigned into an external validation set.All participants completed standardized preoperative contrast-enhanced neck CT scanning.Quantitative radiomic features were systematically extracted from venous phase CT images through an open-source big data AI platform.Six machine learning classifiers,eXtreme Gradient Boosting(XGBoost),Support Vector Machine(SVM),Random Forest(RF),Logistic Regression(LR),k-Nearest Neighbors(KNN),and Decision Tree(DT)were implemented to construct clinical-radiomics integration models.The predictive performance was quantitatively assessed through receiver operating characteristic(ROC)curve analysis,with area under the curve(AUC)values calculated for training,internal validation,and external validation sets.Model interpretability was achieved using Shapley additive explanations(SHAP)framework,with particular focus on elucidating feature contributions in the best-performing model.Results The XGBoost model had an AUC value of 0.936(95%CI:0.895~0.976),0.832(95%CI:0.724~0.941),and 0.772(95%CI:0.632~0.912)in training,internal and external validation sets,respectively.SHAP analysis revealed age as the most influential clinical predictor,with younger patients showing higher CLNM risk(OR=0.968,P=0.042).Conclusion Our machine learning-based clinic-radiomic prediction model demonstrates satisfactory performance in predicting CLNM of PTC,providing valuable references for clinical decision-making.
3.Discovery of orally active and serine-targeting covalent inhibitors against hCES2A for ameliorating irinotecan-triggered gut toxicity.
Ya ZHANG ; Yufan FAN ; Yunqing SONG ; Guanghao ZHU ; Xinjuan LI ; Jian HUANG ; Xinrui GUO ; Changhai LUAN ; Dongning KANG ; Lu CHEN ; Zhangping XIAO ; Zhaobin GUO ; Hairong ZENG ; Dapeng CHEN ; Zhipei SANG ; Guangbo GE
Acta Pharmaceutica Sinica B 2025;15(10):5312-5326
Human carboxylesterase 2A (hCES2A) plays pivotal roles in prodrug activation and hydrolytic metabolism of ester-bearing chemicals. Targeted inhibition of intestinal hCES2A represents a feasible strategy to mitigate irinotecan-triggered gut toxicity (ITGT), but the orally active, selective, and efficacious hCES2A inhibitors are rarely reported. Here, a novel drug-like hCES2A inhibitor was developed via three rounds of structure-based drug design (SBDD) and structural optimization. Initially, donepezil was identified as a moderate hCES2A inhibitor from 2000 US Food and Drug Administration (FDA)-approved drugs. Following two rounds of SBDD and structural optimization, a donepezil derivative (B7) was identified as a strong reversible hCES2A inhibitor. Subsequently, nine B7 carbamates were rationally designed, synthesized and biologically assayed. Among all synthesized carbamates, C3 showed the most potent time-dependent inhibition on hCES2A (IC50 = 0.56 nmol/L), excellent specificity and favorable drug-like properties. C3 could covalently modify the catalytic serine of hCES2A with high selectivity, while this agent also showed favorable safety profiles, high intestinal exposure, and impressive effects for ameliorating ITGT in both human intestinal organoids and tumor-bearing mice. Collectively, this study showcases a rational strategy for developing drug-like and serine-targeting covalent inhibitors against target serine hydrolase(s), while C3 emerges as a promising orally active drug candidate for ameliorating ITGT.
4.Feasibility study on road-rail medical vehicles
Jian-kang WANG ; Pei TIAN ; Fan WU ; Yun-ming LI ; Xia ZHANG ; Mu YUAN ; Xiao-li XU
Chinese Medical Equipment Journal 2025;46(10):84-90
The feasibility for the development of road-rail medical vehicles was discussed.The gap between China's ground medical evacuation system and medical evacuation requirements was analyzed,and the limitations of the existing mobile medical units in China were introduced.The key points for developing road-rail medical vehicles were discussed.The road-rail medical vehicle would be an ideal tool for casualty treatment and rapid evacuation at war time and peace time,which could be a future development direction of the road-rail vehicle and medical train.[Chinese Medical Equipment Journal,2025,46(10):84-90]
5.Feasibility study on road-rail medical vehicles
Jian-kang WANG ; Pei TIAN ; Fan WU ; Yun-ming LI ; Xia ZHANG ; Mu YUAN ; Xiao-li XU
Chinese Medical Equipment Journal 2025;46(10):84-90
The feasibility for the development of road-rail medical vehicles was discussed.The gap between China's ground medical evacuation system and medical evacuation requirements was analyzed,and the limitations of the existing mobile medical units in China were introduced.The key points for developing road-rail medical vehicles were discussed.The road-rail medical vehicle would be an ideal tool for casualty treatment and rapid evacuation at war time and peace time,which could be a future development direction of the road-rail vehicle and medical train.[Chinese Medical Equipment Journal,2025,46(10):84-90]
6.Chinese expert consensus on postoperative follow-up for non-small cell lung cancer (version 2025)
Lunxu LIU ; Shugeng GAO ; Jianxing HE ; Jian HU ; Di GE ; Hecheng LI ; Mingqiang KANG ; Fengwei TAN ; Fan YANG ; Qiang PU ; Kaican CAI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(03):281-290
Surgical treatment is one of the key approaches for non-small cell lung cancer (NSCLC). Regular postoperative follow-up is crucial for early detection and timely management of tumor recurrence, metastasis, or second primary tumors. A scientifically sound and reasonable follow-up strategy not only extends patient survival but also significantly improves quality of life, thereby enhancing overall prognosis. This consensus aims to build upon the previous version by incorporating the latest clinical research advancements and refining postoperative follow-up protocols for early-stage NSCLC patients based on different treatment modalities. It provides a scientific and practical reference for clinicians involved in the postoperative follow-up management of NSCLC. By optimizing follow-up strategies, this consensus seeks to promote the standardization and normalization of lung cancer diagnosis and treatment in China, helping more patients receive high-quality care and long-term management. Additionally, the release of this consensus is expected to provide insights for related research and clinical practice both domestically and internationally, driving continuous development and innovation in the field of postoperative management for NSCLC.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail