1.Expert Consensus on Neurocritical Care Monitoring and Management in Beijing and Tibet(2025)
Drolma PHURBU ; Wenjin CHEN ; Heng ZHANG ; Jian ZHANG ; Xiaomeng WANG ; Guoying LIN ; Wenjun PAN ; Xiying GUI ; Xin CAI ; Chodron TENZIN ; Jianlei FU ; Qianwei LI ; TSEYANG ; Yijun LIU ; Bo LIU ; Tsering DROLMA ; Yudron SONAM ; KYILV ; Samdrup TSERING ; Wa DA ; Juan GUO ; Cheng QIU ; Huan CHEN ; Xiaoting WANG ; Yangong CHAO ; Dawei LIU ; Wenzhao CHAI ; Chenggong HU ; Wanhong YIN ; Shihong ZHU
Medical Journal of Peking Union Medical College Hospital 2026;17(1):59-72
Neurocritical care involves complex pathophysiological mechanisms, and its incidence is higher, injuries are more severe, and treatment is more challenging in high-altitude environments. This consensus, based on the latest domestic and international evidence-based medical data, establishes a standardized, goal-oriented framework for neurocritical care management applicable in high-altitude regions and nationwide. The consensus was developed following international standards for evidence quality assessment and underwent two rounds of Delphi expert consultation, resulting in 32 recommendation statements covering three parts: management systems, monitoring and assessment, and core strategies. Key updates include: advocating for the establishment of independent neurocritical care units and implementing precise tiered diagnosis and treatment based on the "Five Differences in Critical Care" concept; constructing a "trinity" multimodal brain monitoring system centered on cerebral blood flow, cerebral oxygenation, and brain function, emphasizing routine bedside transcranial Doppler ultrasound, cerebral oximetry, and continuous electroencephalography monitoring; shifting management strategies from mild hypothermia therapy to targeted temperature management, and defining the "446" target management pathway for the supercritical stage; emphasizing the assessment of static and dynamic cerebrovascular autoregulation functions through multimodal methods to achieve individualized optimal mean arterial pressure management; elevating cerebrospinal fluid management goals to the level of "glymphatic system" function maintenance; implementing a multidisciplinary collaborative, whole-process management model focusing on patients' long-term neurological functional outcomes; de-escalation criteria include multidimensional indicators such as recovery of brain structure, restoration of cerebrovascular autoregulation, improvement in cerebrospinal fluid dynamics, and reduction in biomarker levels; and integrating cutting-edge technologies like artificial intelligence into post-critical care management and rehabilitation planning. This consensus systematically integrates the entire process of neurocritical care management, reflecting the modern connotation of goal-oriented, dynamic, and multimodal integration in neurocritical care medicine. It aims to adapt to new trends such as deepening understanding of pathophysiological mechanisms, the integration of medicine and engineering, and the empowerment of artificial intelligence, thereby further advancing the discipline of critical care medicine.
2.Two cases of rare K phenotype caused by the KEL c.715G>T mutation
Jing LI ; Jing ZHANG ; Zhixia CHENG ; Jian DU ; Xiaoling ZHANG
Chinese Journal of Blood Transfusion 2026;39(4):526-533
Objective: To investigate the serological identification and blood group gene sequencing analysis of two rare cases of K
phenotype producing high-frequency antigen antibodies (anti-Ku), and to study the serological interrelationship between K
cells and the high-frequency antigen antibody anti-KL. Methods: Serological methods were used to identify the antigen phenotypes of the ABO, Rh, and Kell blood group systems and to screen for and identify unexpected antibodies in the two patients. The characteristics of the unexpected antibodies were verified by the indirect antiglobulin test (IAT) using papain or dithiothreitol (DTT) -treated screening cells. The titer of anti-Ku was determined via the tube method using DTT-treated plasma. The Kell blood group genotype was determined by gene sequencing. The distinctive antigenicity of K
cells was validated through their reactivity with anti-KL in IAT, and absorption-elution techniques were employed to corroborate the type of anti-KL. Results: Serological findings: Case 1 was blood group O, CCDee; Case 2 was blood group A, CCDee. Both cases exhibited the Kell phenotype: K-k-, Kp (a-b-). High-frequency antigen antibodies were detected in the plasma of both patients. The reactivity of these antibodies was slightly enhanced with papain-treated screening cells but became negative with DTT-treated cells. The anti-Ku (IgG) titer for Case 1 was 64. For Case 2, the anti-Ku (IgM) titer was<1, and the anti-Ku (IgG) titer was 32. Gene sequencing revealed that both cases harbored a homozygous c.715G>T mutation in the KEL gene, corresponding to the genotype KEL02N.24, consistent with the rare K
phenotype. The unique high expression of the Kx antigen on K
cells was confirmed through the antibody characteristics of anti-KL. Absorption-elution techniques demonstrated that K
cells could separate anti-Km and anti-Kx, thereby supporting the classification of anti-KL. Conclusion: Serological and molecular biological assays identified both patients as having the rare Kell-null (K
) phenotype. If such rare blood types go undetected in transfusion medicine, the administration of standard blood products can readily induce the production of high-frequency antigen antibodies such as anti-Ku, potentially leading to a transfusion crisis due to the subsequent difficulty in finding compatible blood. The serological relationship between K
cells and anti-KL clarified the characteristic high expression of the Kx antigen on K
phenotype erythrocytes and concurrently supported the typological features of the rare high-frequency antibody anti-KL. This represents the first such verified report in China.
3.Comprehensive evaluation of benign and malignant pulmonary nodules using combined biological testing and imaging assessment in 1 017 patients: A retrospective cohort study
Lei ZHANG ; Zihao LI ; Nan LI ; Jun CHENG ; Feng ZHANG ; Pinghui XIA ; Wang LÜ ; ; Jian HU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(01):60-66
Objective By combining biological detection and imaging evaluation, a clinical prediction model is constructed based on a large cohort to improve the accuracy of distinguishing between benign and malignant pulmonary nodules. Methods A retrospective analysis was conducted on the clinical data of the 32 627 patients with pulmonary nodules who underwent chest CT and testing for 7 types of lung cancer-related serum autoantibodies (7-AABs) at our hospital from January 2020 to April 2024. The univariate and multivariate logistic regression models were performed to screen independent risk factors for benign and malignant pulmonary nodules, based on which a nomogram model was established. The performance of the model was evaluated using receiver operating characteristic (ROC) curves, calibration curves, and decision curve analysis (DCA). Results A total of 1 017 patients with pulmonary nodules were included in the study. The training set consisted of 712 patients, including 291 males and 421 females, with a mean age of (58±12) years. The validation set included 305 patients, comprising 129 males and 176 females, with a mean age of (58±13) years. Univariate ROC curve analysis indicated that the combination of CT and 7-AABs testing achieved the highest area under the curve (AUC) value (0.794), surpassing the diagnostic efficacy of CT alone (AUC=0.667) or 7-AABs alone (AUC=0.514). Multivariate logistic regression analysis showed that radiological nodule diameter, nodule nature, and CT combined with 7-AABs detection were independent predictors, which were used to construct a nomogram prediction model. The AUC values for this model were 0.826 and 0.862 in the training and validation sets, respectively, demonstrating excellent performance in DCA. Conclusion The combination of 7-AABs with CT significantly enhances the accuracy of distinguishing between benign and malignant pulmonary nodules. The developed predictive model provides strong support for clinical decision-making and contributes to achieving precise diagnosis and treatment of pulmonary nodules.
4.Intrahepatic cholangiocarcinoma tumor size classification based on prognostic analysis: a retrospective multicenter study
Jiaqian CHEN ; Hongzhi LIU ; Lingtian MENG ; Weiping ZHOU ; Zhangjun CHEN ; Jianying LOU ; Shuguo ZHENG ; Xinyu BI ; Jianming WANG ; Wei GUO ; Fuyu LI ; Jian WANG ; Yamin ZHENG ; Jingdong LI ; Shi CHENG
Journal of Surgery Concepts & Practice 2025;30(4):332-338
Objective To retrospectively analyze multicenter data from domestic sources, aiming to explore the link between intrahepatic cholangiocarcinoma (ICC) tumor size and prognosis, establishing a classification system based on tumor size. Methods Between December 2011 and September 2018, 280 ICC patients from 13 hospitals were included. The tumor size prognosis cutoff was identified by the minimum P-value method, and the classification's overall survival related effectiveness was assessed by Kaplan-Meier analysis. Results All 280 patients were divided into the group of tumor maximum diameter ≤4 cm and >4 cm. Tumor size was confirmed as an independent prognosis factor by multivariate COX regression analysis (HR=2.110, 95% CI: 1.358-3.280). Conclusions The tumor size dichotomy classification system based on the Chinese patient group can expediently predict ICC prognosis and offers an important basis for selecting post-operative individualized adjuvant therapy and follow up plans.
5.Changes in characteristics of gut fungal microbiota and their correlation with clinical indicators in patients with polycystic kidney disease
Zhanjie HOU ; Yusong GE ; Bo TANG ; Yuanyuan LEI ; Li TANG ; Hongfei JIANG ; Jincheng JIAN ; Jinbo CHENG ; Shiming YANG
Journal of Army Medical University 2025;47(8):836-846
Objective To investigate the diversity and composition of gut fungi microbiota in patients with polycystic kidney disease(PKD)and its correlation with clinical indicators.Methods A total of 44 PKD patients,44 patients with non-polycystic chronic kidney disease(NPCKD)and 22 healthy controls(HC)admitted to our hospital from February 2023 to February 2024 were recruited.ITS1 DNA sequencing was applied to analyze the gut fungal composition.Bioinformatics analysis was used to compare the diversity and structural differences of fungi among the 3 groups.Pearson correlation analysis was performed to analyze the relationship between gut fungi and clinical indicators.Results There were no significant differences in baseline characteristics(gender,age,body mass index,etc.)among the 3 groups,but statistical differences were seen in terms of serum indicators(such as serum creatinine,blood urea nitrogen,uric acid,estimated glomerular filtration rate,etc.)(P<0.01).Alpha diversity analysis showed no significant difference was seen between the PKD and HC groups,but the PKD group had significant differences to the NPCKD group(P<0.01).Beta diversity analysis revealed significant differences among the 3 groups and in pairwise comparisons(P=0.001).Fungi composition analysis found that the abundance of Candida was significantly higher in the PKD group than the other 2 groups(P<0.01),while the abundances of Aspergillus and Cladosporium were significantly lower in the PKD group than the HC group(P<0.05).Linear discriminant analysis(LEFSe)indicated that Candida was significantly enriched,while Aspergillus and Cladosporium were significantly reduced in the PKD group.Correlation analysis revealed that the abundance of Cladosporium was negatively correlated with cyst diameter and immunoglobulin light chain Kappa/Lambda ratio in the PKD group(P<0.05),while the abundance of Candida was positively correlated with liver/kidney cyst diameter(P<0.01).Conclusion PKD patients exhibit characteristic changes in gut fungi diversity and composition.The abundances of Cladosporium and Candida are closely associated with clinical indicators of PKD patients.
6.Effect of intestinal air cavity on dose distribution of volumetric intensity modulated arc therapy for cervical cancer
Jiayi XU ; Jian GUAN ; Rui HU ; Ying LI ; Cheng LI
International Journal of Biomedical Engineering 2025;48(2):145-151
Objective:To investigate the effect of intestinal air cavity on dose distribution of volumetric intensity modulated arc therapy (VMAT) for cervical cancer.Methods:A total of 10 patients who underwent radiotherapy for cervical cancer at Suzhou Municipal Hospital from January to May 2021 were retrospectively analyzed. For each patient, the same optimization parameters were used to design both a normal full-arc plan and a field avoidance-region plan. The intestinal air cavity identified on computed tomography (CT) imaging was outlined as a separate structure. The dose distribution of the two plans were compared before and after changing the CT value (the electron density of the intestinal air cavity) to 0, using a paired t-test. Additionally, consecutive three-week cone beam CT (CBCT) images were collected for each patient. The intestinal air cavities from the three-week CBCT images were mapped onto the original CT, and the dose distributions of both plans were calculated on the CBCT images. The differences in dose distributions compared to the original plan were analyzed to assess plan robustness. Results:The 105% prescription dose coverage of the target volume ( V105) [(43.62±5.18)%)] within the target area for the field avoidance-region plan was greater than that for the normal full-arc plan [(36.38±10.20)%], with a statistically significant difference ( P<0.05). After modifying the electron density of the intestinal air cavity, the dose distribution in the target area worsened for both plans. However, the V100 and V105 for the field avoidance-region plan [(?0.64±0.58)%, (?2.16±1.66)%] were smaller than those for the normal full-arc plan [(?2.52±1.91)%, (?6.79±2.02)%], with a statistically significant difference (both P<0.05).The V30 for the small intestine in the field avoidance-region plan [(40.28±4.77)%] was lower than that in the normal full-arc plan [(42.63±4.82)%]. The V40 for the rectum [(61.70±15.39)%] and the V20 [(36.32±3.09)%, (35.06±5.32)%] and V30 [(17.76±3.05)%, (16.67±8.14)%] for the left and right femoral heads were higher than those in the normal full-arc plan {(59.72±15.13)%, [(31.36±3.97)%, (27.00±7.79%)] and [(12.99±4.55)%, (11.11±7.20)%]}, respectively, with a statistically significant differences (all P<0.05). The changes in V105 on the weekly CBCT images [(3.27±2.91)%, (2.07±2.93)%, (2.14±2.08)%] and V100 on the second and third weeks′ images [(0.44±0.54)%, (0.54±0.50)%] for the field avoidance-region plan were smaller than those for the normal full-arc plan [(8.22±5.87)%, (5.31±3.97)%, (6.91±3.34)% and (1.70±1.53)%, (2.22±1.97)%], with a statistically significant difference (all P<0.05). Conclusions:The field avoidance-region plan demonstrates higher robustness and better small bowel protection than the normal full-arc plan. The influence of intestinal air cavities on dose distribution should be considered during VMAT planing for cervical cancer to guide optimal plan selection.
7.Analysis of dosimetric characteristics of proton radiotherapy in 1 case of whole central nervous system tumor
Shizhang WU ; Man HU ; Tianyuan DAI ; Chengqiang LI ; Cheng TAO ; Jinghao DUAN ; Jinhu CHEN ; Tong BAI ; Tian KONG ; Jian ZHU
Journal of International Oncology 2025;52(7):434-440
Objective:To explore the dosimetric characteristics of intensity modulated proton therapy (IMPT), intensity modulated radiation therapy (IMRT) and tomotherapy (TOMO) techniques applied in the irradiation of pediatric whole central nervous system tumors.Methods:Taking the target area of a 14-year-old pediatric patient clinically diagnosed with atypical teratoid/rhabdomyoid tumor, meningeal metastasis by Shandong Cancer Hospital and Institute, and undergoing craniospinal irradiation (CSI) as an example, IMPT, IMRT and TOMO plans were designed respectively based on the clinical prescription of the target area and the limit requirements of organs at risk (OARs). The conformal index (CI), homogeneity index (HI) and gradient index (GI) of each planning target volume, as well as the dose volume index of normal tissues, were evaluated to compare the dosimetric characteristics of the three types of plans.Results:The CI (0.71), HI (0.05) and GI (3.13) of the IMPT plan were comparable to those of IMRT plan (0.80, 0.08, 3.14). The HI (0.03) and GI (2.54) of the TOMO plan were excellent, which were all within the clinically acceptable range. The irradiation dose to parallel organs in the IMPT plan was lower than that in the IMRT and TOMO plan. In the IMPT plan, V 5 of lungs was 2.9%, IMRT plan was 37.6%, and TOMO plan was 43.5%. The D mean of liver in the IMPT plan was 0.01 Gy (RBE), IMRT plan was 6.12 Gy, and TOMO plan was 6.39 Gy. In the IMPT plan, none of the bladder, rectum, and femoral head received the dose, while there was low-dose radiation in both IMRT and TOMO plan. For serial organs adjacent to and within the target area, the D max of spinal cord and brainstem in IMPT plan was 39.89 and 39.88 Gy (RBE), respectively; in IMRT plan, they were 39.43 and 38.59 Gy, respectively; and in TOMO plan, they were 38.41 and 37.69 Gy, respectively. The low-dose area in the IMPT plan was significantly better than the photon radiotherapy plans. Among them, the absolute volume IMPT plan occupied by 10% of the prescribed dose area in the patient's body was reduced by 70.10% compared with IMRT plan and 76.96% compared with TOMO plan; the 30% prescribed dose volume IMPT plan was reduced by 53.49% compared with IMRT plan and 62.51% compared with TOMO plan; the 50% prescribed dose volume IMPT plan was reduced by 39.06% compared with IMRT plan and 42.23% compared with TOMO plan. Conclusions:The IMPT plan demonstrated significantly reduced low-dose exposure and lower doses to parallel OARs compared to both IMRT and TOMO plans in pediatric CSI. The CI, HI and GI of the three plans can all meet the clinical requirements. However, for serial organs adjacent to and within the target area, the D max of the IMPT plan may be higher than that of IMRT and TOMO plans.
8.Analysis of dosimetric characteristics of proton radiotherapy in 4 cases of breast cancer
Chengqiang LI ; Yungang WANG ; Yishan YU ; Shizhang WU ; Cheng TAO ; Xingmin MA ; Tianyuan DAI ; Jinghao DUAN ; Jinhu CHEN ; Tong BAI ; Jian ZHU
Journal of International Oncology 2025;52(7):448-454
Objective:To explore the dosimetric characteristics of proton and photon radiotherapy in the treatment of breast cancer.Methods:Four female breast cancer patients who needed radiotherapy at Shandong Cancer Hospital and Institute from January 2024 to May 2024 were selected as the research subjects. The target area ranges of 4 patients were left-sided breast cancer with lymph node involvement, left-sided breast cancer with lymph node involvement and internal mammary node, right-sided breast cancer with lymph node involvement and internal mammary node and synchronous bilateral breast cancer. Intensity modulated proton therapy (IMPT) and intensity modulated radiation therapy (IMRT) plans were designed respectively based on the prescribed dose in the target area and the limits of organs at risk (tomotherapy plan for bilateral breasts). The conformity index (CI), homogeneity index (HI), gradient index (GI) and organs at risk doses were evaluated. The dosimetric characteristics of IMPT and photon radiotherapy were compared.Results:Both IMPT and photon radiotherapy plans of the 4 breast cancer cases met the clinical dose requirements. The HI value of IMPT plans (0.10-0.14) was comparable to that of photon radiotherapy plans (0.10-0.12), and the average CI of the photon radiotherapy plans was 0.10 higher than that of the IMPT plans, and the average GI was 0.55 lower than that of the IMPT plans. The D mean of ipsilateral lung and heart of IMPT was lower, especially in the low-dose area (V 0-3), which was significantly lower than the photon radiotherapy plans, D mean of ipsilateral lung was reduced by 12.2%, 6.1%, 16.1% and 34.8%, respectively, D mean of heart was reduced by 47.2%, 57.0%, 72.4% and 83.0%, respectively. The ipsilateral lung V 20 of IMPT was not lower than photon radiotherapy plans (unilateral breast: IMPT was 30.0%-34.0%, IMRT was 29.0%-35.9%) . Conclusions:IMPT significantly reduces the D mean to the ipsilateral lung and heart while ensuring dose coverage of the target in breast cancer, preventing more volume of surrounding normal tissues from being irradiated. However, IMPT does not show much more advantage than photon radiotherapy plans in the ipsilateral lung V 20.
9.Analysis of dosimetric characteristics of proton radiotherapy in 3 cases of abdominal and pelvic tumors
Jinghao DUAN ; Jinbo YUE ; Cheng TAO ; Shizhang WU ; Chengqiang LI ; Tianyuan DAI ; Jinhu CHEN ; Tong BAI ; Jian ZHU
Journal of International Oncology 2025;52(7):455-461
Objective:To explore the dosimetric characteristics of intensity modulated proton therapy (IMPT) and intensity modulated radiation therapy (IMRT) for typical abdominal and pelvic tumors.Methods:Three patients with abdominal and pelvic tumors (one case each of liver cancer, cervical cancer, and prostate cancer) admitted to Shandong Cancer Hospital and Institute from January to June 2024 were selected as the research subjects. IMPT and IMRT plans were designed for each case based on clinical target volume (CTV) and organs at risk (OARs) constraints. Dosimetric parameters, including conformity index (CI), homogeneity index (HI), and gradient index (GI) for target coverage, as well as OARs dose metrics, were evaluated. The volume of additional dose deposition in the body was compared by assessing regions receiving 10%, 30%, and 50% of the prescription dose.Results:For all three cases, IMRT plan demonstrated higher CI values (0.82, 0.81, and 0.86) compared to IMPT plan (0.61, 0.62, and 0.43). IMPT plan yielded lower HI values (0.053, 0.075, and 0.020) than IMRT plan (0.060, 0.120, and 0.080) and lower GI values (3.45, 2.63, and 3.80 vs. 7.28, 4.76, and 4.66 for IMRT plan). In liver cancer, IMPT plan reduced the D mean of normal liver tissues and right kidney by 37.8% and 78.5%, respectively, and decreased the D max of spinal cord by 13.2%. For cervical cancer, IMPT plan reduced the V 30 of the small bowel by 22.0%, D mean of the bladder, rectum and bone marrow by 15.7%, 14.3% and 12.6%, and spinal cord D max by 4.8%. In prostate cancer, IMPT plan lowered bladder and rectal D mean by 14.9% and 36.5%, respectively, but resulted in an increase of 35.3% and 6.1% in the D mean and V 40 of the left femoral head, respectively, and an increase of 23.6% and 10.8% in the D mean and V 40 of the right femoral head, respectively. IMPT plan reduced the volumes receiving 10%, 30%, and 50% of the prescription dose by 48.9%-64.8%, 22.0%-47.0%, and 22.0%-57.7%, respectively, compared to IMRT plan. Conclusions:Comparison between IMPT and IMRT plans for abdominopelvic tumors: IMPT plan offers advantages in reducing doses to normal organs such as the liver, kidneys, spinal cord, small intestine, rectum, and bladder. However, its advantage is less pronounced regarding the dose to the femoral heads. IMPT plan notably minimizes additional dose deposition within the body.
10.Study on dosimetric characteristics of proton radiotherapy in 3 cases of head and neck tumors
Weijie LI ; Tianyuan DAI ; Man HU ; Shizhang WU ; Chengqiang LI ; Cheng TAO ; Jinghao DUAN ; Jinhu CHEN ; Tong BAI ; Guohui WEI ; Jian ZHU
Journal of International Oncology 2025;52(10):646-652
Objective:To investigate the dosimetric characteristics of intensity modulated proton therapy (IMPT) and photon volumetric modulated arc therapy (VMAT) in typical head and neck malignant tumors.Methods:Three types of typical head and neck tumors (nasopharyngeal carcinoma, parotid gland carcinoma, laryngeal carcinoma) treated at Shandong Cancer Hospital and Institute from December 2023 to December 2024 were taken as research subjects. IMPT and VMAT radiotherapy plans were created according to clinical prescription requirements of target and organs at risk limits respectively. The conformity index (CI), homogeneity index (HI) and gradient index (GI) for target coverage of two radiotherapy plans were evaluated for 3 patients, as well as the dosimetric indicators of organs at risk.Results:The CI of IMPT for nasopharyngeal carcinoma, parotid gland carcinoma and laryngeal carcinoma were 0.70, 0.72 and 0.67, respectively. The HI were 0.11, 0.08 and 0.08, respectively. The GI were 3.08, 2.49 and 3.75, respectively. The CI of VMAT plans were 0.77, 0.82 and 0.91, respectively. The HI were 0.12, 0.10 and 0.04, respectively. The GI were 3.67, 2.63 and 3.45, respectively. The results showed that CI of IMPT plan was slightly lower than that of VMAT plan, and HI of IMPT plan was comparable to that of VMAT plan, the GI of the IMPT plan for patients with nasopharyngeal carcinoma and parotid gland carcinoma was lower than that of the VMAT plan, and the GI of the IMPT plan for patient with laryngeal carcinoma was higher than that of the VMAT plan, and all were within the clinically acceptable range. The IMPT plan has demonstrated significant dose advantages in the treatment of nasopharyngeal carcinoma, parotid gland carcinoma and laryngeal carcinoma. For patient with nasopharyngeal carcinoma, the IMPT plan reduced the D max of the left and right crystals by 54.1% and 50.4%, respectively, compared to VMAT plan, and reduced the D mean of the oral and laryngeal tissues by 40.5% and 49.6%, respectively. For patient with parotid gland carcinoma, IMPT plan reduced the D max of the brainstem and spinal cord by 66.2% and 40.5%, respectively, compared to VMAT plan. For patient with laryngeal carcinoma, IMPT reduced spinal cord D max by 77.0%, while thyroid cartilage D mean increased by 8.0% compared to VMAT plan. For the additional dose in the patients' body, taking the absolute volumes occupied by the prescribed dose areas of 10%, 30%, and 50% in the patients' body as examples, IMPT plan of nasopharyngeal carcinoma patient decreased by 29.7%, 29.6%, and 34.9% compared to VMAT plan, respectively. IMPT plan of parotid gland carcinoma patient decreased by 61.0%, 39.7%, and 17.4% compared to VMAT plan, respectively. IMPT plan of laryngeal carcinoma patient decreased by 63.9%, 31.7%, and 4.1% compared to VMAT plan, respectively. Conclusions:Compared with VMAT plan, IMPT plan can effectively reduce the irradiation dose of most organs at risk near the target of head and neck tumors, but the dose of string organs close to the target area may be higher, which needs attention.

Result Analysis
Print
Save
E-mail