1.Quality of care among patients with acute heart failure at the emergency room and adherence of physicians at the University of the Philippines – Philippine General Hospital to the division of cardiovascular medicine – heart failure pathway:A retrospective cohort study.
Mark John D. Sabando ; Felix Eduardo R. Punzalan ; Frances Dominique V. Ho ; Tam Adrian P. Aya-ay ; Kevin Paul Da. Enriquez ; Marie Kirk A. Maramara ; Ronald Allan B. Roderos ; Lauren Kay M. Evangelista
Acta Medica Philippina 2026;60(2):22-32
OBJECTIVES
Clinical pathways (CPs) ensure adherence to heart failure (HF) management guidelines. To optimize quality care in a low resource setting, an evidence-based care pathway for the management of acute HF was implemented at the emergency department (ED) of the Philippine General Hospital (PGH), the designated national tertiary hospital and referral center. This study aimed to describe the characteristics of adults with acute HF admitted at the ED and evaluate the quality of care they received, measured using physician adherence to the hospital’s acute heart failure CP.
METHODSThis was a retrospective, descriptive cohort study. We reviewed the inpatient charts of all adult patients with acute HF admitted to the ED of the PGH and referred to the Division of Cardiovascular Medicine between December 1, 2022 and May 31, 2023. Quality of care was assessed based on adherence to quality indicators adapted from routine and conditional order sets detailed in the pathway. Descriptive statistics was utilized to describe patient characteristics, quality of care, and outcomes.
RESULTSTwo hundred thirty-six (236) patients were included, with a mean age of 51.8 years. Majority were male (53.4%); hypertension (61.4%) and ischemic heart disease (53.8%) were the most common comorbidities, and infection the most common precipitant of decompensation (60.6%). There were optimal adherence rates to routine orders, which included referrals to Internal Medicine and Cardiology, baseline vital signs monitoring, fluid intake and output monitoring, chest radiograph, complete blood count, blood urea nitrogen, sodium, potassium, prothrombin time, partial thromboplastin time, arterial blood gas, urinalysis, and N-terminal pro b-type natriuretic peptide. Conditional orders, such as oxygen support, focused echocardiography, thyroid - stimulating hormone, and the use of vasopressors, diuretics, and venous thromboembolism prophylactic agents, were optimally performed when warranted. However, we noted suboptimal adherence to certain resource-intensive conditional orders, such as hourly monitoring of urine output (61.4%), hooking to cardiac monitor (53.8%), and performance of 12-lead ECG within 10 minutes (56.8%). Further, only 43.9% of patients were referred to the intensive care unit. Troponin I, calcium, magnesium, and albumin were ordered in excess.
CONCLUSIONOverall adherence rate of physicians to the hospital’s Acute Heart Failure Pathway was satisfactory. Work is needed to improve adherence to hourly urine output monitoring, consistent hooking to cardiac monitor, and timely performance of 12-lead ECG – an effort that begins with expanding in-hospital diagnostic equipment and human resource supply. We recommend continuous pathway implementation with periodic evaluation and stakeholder feedback to further improve quality of care.
Human ; Male ; Female ; Middle Aged: 45-64 Yrs Old ; Adult ; Albumins ; Blood ; Blood Urea Nitrogen ; Calcium ; Cardiology ; Chart ; Charts ; Cohort Studies ; Critical Care ; Critical Pathways ; Diagnostic Equipment ; Disease ; Diuretics ; Echocardiography ; Electrocardiography ; Emergencies ; Emergency Service, Hospital ; Equipment And Supplies ; Evaluation Studies As Topic ; Feedback ; Heart ; Heart Diseases ; Heart Failure ; Hormones ; Hospitals ; Hospitals, General ; Humans ; Hypertension ; Indicators And Reagents ; Infection ; Infections ; Inpatients ; Intensive Care Units ; Internal Medicine ; Lead ; Magnesium ; Male ; Medicine ; Myocardial Ischemia ; Natriuretic Peptide, Brain ; Natriuretic Peptides ; Nitrogen ; Overall ; Oxygen ; Partial Thromboplastin Time ; Patients ; Peptides ; Philippines ; Physicians ; Potassium ; Prothrombin ; Prothrombin Time ; Quality Of Health Care ; Referral And Consultation ; Sodium ; Statistics ; Tertiary Care Centers ; Thorax ; Thromboembolism ; Thromboplastin ; Thyroid Gland ; Time ; Troponin ; Troponin I ; Universities ; Urea ; Urinalysis ; Urine ; Venous Thromboembolism ; Vital Signs ; Work ; Workforce
2.Analysis of recurrent cervical abscess: a case report.
Junxin WANG ; Hui WANG ; Maogang SUN ; Endong ZHANG ; Zhonghua ZHANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(6):574-577
This report presents a case of esophageal fistula with recurrent cervical abscess as the initial symptom. The patient underwent anterior cervical fracture reduction and internal fixation in 2021 due to trauma. In 2023, the patient received radiofrequency ablation for bilateral thyroid lobe lesions, after which recurrent cervical abscesses occurred over an 8-month period. Fiberoptic laryngoscopy with the biopsy channel insufflation method revealed a large esophageal fistula at the esophageal inlet. After removing the internal fixation plate, the patient received daily wound care, and serial fiberoptic laryngoscopy revealed spontaneous healing of the esophageal fistula. During the 1-year follow-up, no recurrence of cervical abscess was observed, and the esophageal fistula healed well.
Humans
;
Abscess
;
Recurrence
;
Neck
;
Female
;
Adult
;
Fracture Fixation, Internal
3.Biomechanical analysis of a novel bridging plate for treating Rockwood III acromioclavicular joint dislocation.
Yancai CHEN ; Gaofeng ZHANG ; Shubo LI ; Nianxiang LUO ; Yi ZHANG
Journal of Southern Medical University 2025;45(5):1103-1112
OBJECTIVES:
To assess the biomechanical performance of a novel bridging plate for treating Rockwood III acromioclavicular joint dislocation.
METHODS:
A novel bridging plate structure was designed based on CT data from a patient with Rockwood type III acromioclavicular joint dislocation, and a finite element model of the bridging plate-acromioclavicular joint interaction was constructed. The stress and deformation characteristics and biomechanical compatibility of the plate under post-reduction, normal loading, and impact loading conditions were analyzed to evaluate its fixation mechanism and clinical advantages.
RESULTS:
The stiffness of the bridging system was 27.78 N/mm, close to that of acromioclavicular joint ligaments (26.05 N/mm) and meeting the requirements for flexible deformation. Under normal loading, the maximum stress in the bridging system was 88.29 MPa to sustain physiological activities; under impact loading, the maximum stress reached 480 MPa, and the cable underwent plastic deformation to dissipate energy and effectively buffer local stress concentrations, thereby reducing the risk of rigid bone fractures. The high-stress regions in the bone primarily occurred at the edges of the C1-C4 screw holes. The maximum bone stress was 0.762 MPa under normal loading and 5.963 MPa under impact loading, accounting for 2.86% and 1.66% of the corresponding bolt stresses, respectively.
CONCLUSIONS
The novel bridging plate is better adapted to biomechanical characteristics of the acromioclavicular joint compared to traditional internal fixation. This fixation system provides sufficient stability while allowing physiological micromotion to facilitate postoperative rehabilitation. Significant flexible deformation can occur at the connection between the fixation ring and the cable, and brittle materials should not be used in this region. The issue of stress concentration at the C1-C4 screw holes requires special attention in its clinical application.
Acromioclavicular Joint/surgery*
;
Humans
;
Bone Plates
;
Biomechanical Phenomena
;
Finite Element Analysis
;
Joint Dislocations/surgery*
;
Fracture Fixation, Internal/methods*
4.Biomechanical analysis of three kinds of rigid internal fixation methods for condylar head fractures.
Junhui SUN ; Duoduo LAN ; Dong WANG ; Yao XU ; Zeyu WANG ; Chenchen ZHANG ; Kai ZHANG ; Tao XU
West China Journal of Stomatology 2025;43(1):126-132
OBJECTIVES:
This study aims to analyze the biomechanics of three kinds of rigid internal fixation methods for condylar head fractures.
METHODS:
A three dimensional finite element model of the normal mandible was constructed. It was then used to prepare condylar head fracture finite element model and three kinds of rigid internal fixation finite element model (unilateral tension screw, bilateral tension screw, tension screw+titanium plate). The mechanical characteristics and changes of the mandible condyle under the same mechanical conditions were compared among the three different rigid internal fixation methods.
RESULTS:
The maximum equivalent stress and displacement of the non-free end of condyle under the rigid internal fixation method of unilateral tension screw were 71.03 MPa and 4.72 mm, respectively. The maximum equivalent stress and displacement of the free end of condyle were 78.45 MPa and 4.50 mm, respectively. The maximum stress of fracture suture was 3.27 MPa. The maximum equivalent stress and displacement of the non-free end of condyle under the rigid internal fixation method of bilateral tension screw were 70.52 MPa and 4.00 mm, respectively. The maximum equivalent stress and displacement of the free end of condyle were 72.49 MPa and 3.85 mm, respectively. The maximum stress of fracture suture was 2.33 MPa. The maximum equivalent stress and maximum displacement of the non-free end of condyle under the rigid internal fixation method of tension screw+titanium plate were 67.26 MPa and 2.66 mm, respectively. The maximum equivalent stress and maximum displacement of the free end of condyle were 69.66 MPa and 2.50 mm, respectively. The maximum stress of fracture suture was 2.18 MPa.
CONCLUSIONS
The tension screw+titanium plate rigid internal fixation method is the most conducive to biomechanical distribution for condylar head fractures.
Fracture Fixation, Internal/instrumentation*
;
Mandibular Condyle/surgery*
;
Biomechanical Phenomena
;
Bone Screws
;
Finite Element Analysis
;
Humans
;
Mandibular Fractures/surgery*
;
Bone Plates
;
Titanium
;
Stress, Mechanical
5.Early warning model of postoperative infection of internal fixation device in maxillofacial fracture based on the synthetic minority over-sampling technique algorithm.
Jinfeng JIANG ; Haiyan WANG ; Yanfeng SHI ; Ke XU
West China Journal of Stomatology 2025;43(6):837-844
OBJECTIVES:
This study investigates independent risk factors for postoperative internal fixation device infection in patients with maxillofacial fractures and proposes an early warning model based on the synthetic minority over-sampling technique (SMOTE) algorithm.
METHODS:
A total of 1 104 patients who underwent surgical treatment for maxillofacial fractures at Oral and Maxillofacial Surgery Department, Affiliated Hospital of Nantong University from January 2021 to December 2024 were retrospectively analyzed. The patients were divided into two groups based on the presence of postoperative internal fixation device infection: the infection group (27 cases) and non-infection group (1 077 cases). Clinical data from both groups were collected and subjected to statistical analysis. Univariate and binary Logistic regression analysis were used to identify risk factors for postoperative internal fixation device infection in maxillofacial fractures. Subsequently, a Logistic regression model was established, and the dataset was improved based on the SMOTE algorithm to construct an early warning model with the improved dataset. The prediction performance of the models was compared and validated.
RESULTS:
Among the 1 104 patients who underwent surgical treatment for maxillofacial fractures, 27 cases of postoperative internal fixation device infections were identified, corresponding to an infection rate of 2.45% (27/1 104). Age, diabetes history, fracture severity, and oral hygiene status were all identified as risk factors for postoperative internal fixation device infections in maxillofacial fractures (all P<0.05). The prediction model based on the original data (P1). The prediction model based on the SMOTE algorithm (P2). Receiver operating characteristic (ROC) curve analysis shows that the area under curve (AUC) for the P2 model was 0.882, the P1 model was 0.861, indicating the superior predictive performance of the P2 model. The DeLong test results show that the difference in AUC between the two models was statistically significant (P<0.05).
CONCLUSIONS
Age, diabetes history, postoperative fracture severity, and oral hygiene status are all risk factors for infections associated with internal fixation devices after maxillofacial fracture surgery. The proposed early warning model demonstrated good predictive performance. Medical professionals can utilize this model to effectively intervene and anticipate infections related to internal fixation devices after maxillofacial fracture surgery.
Humans
;
Algorithms
;
Retrospective Studies
;
Male
;
Female
;
Fracture Fixation, Internal/instrumentation*
;
Risk Factors
;
Middle Aged
;
Adult
;
Logistic Models
;
Surgical Wound Infection/epidemiology*
;
Aged
;
Internal Fixators/adverse effects*
;
Maxillofacial Injuries/surgery*
;
Adolescent
6.The epidemiology and distribution of hand fractures in Singapore.
Jin Xi LIM ; Lan Anh Thi LE ; Jared Ze Yang YEH ; Jia Jun Justin BOEY ; Vaikunthan RAJARATNAM
Singapore medical journal 2025;66(9):476-480
INTRODUCTION:
The aim of this study was to elucidate the epidemiology and distribution of hand fractures in Singapore.
METHODS:
A total of 701 hand fractures in 596 patients aged 21 years and above from a single centre were reviewed from 2010 to 2011. Details regarding the patient demographics, occupation, mechanism of injury, associated injuries and treatment were obtained.
RESULTS:
Hand fractures were particularly significant in patients between the ages of 21 and 40 years 58.9% of the total cases. The relative risk of hand fractures in males was 5.5 times greater than that in females. The majority of hand fractures occurred at the workplace (47.7%), with crush injury being the main mechanism of injury (33.6%). The most common locations of hand fracture were the little finger ray (31.2%) and distal phalanges (37.7%). There were 170 cases that underwent surgical fixation, which accounted for 24.3% of all fractures. Fixation rate was similar for both closed and open fractures but was significantly higher in the proximal and middle phalanges compared to the distal phalanx and metacarpal ( P < 0.001). With regards to surgical fixation methods, wires were commonly used in either tuft fractures (100.0%) or intra-articular fractures (69.9%), whereas plates and screws were commonly used in shaft fractures (65.5%).
CONCLUSION
The most significant population that sustained hand fractures in Singapore are young to middle-aged males who are skilled manual workers. The most commonly involved ray and location of hand fractures are the little finger ray and the distal phalanges, respectively, as they are in a relatively more exposed location.
Humans
;
Singapore/epidemiology*
;
Male
;
Female
;
Adult
;
Middle Aged
;
Fractures, Bone/surgery*
;
Hand Injuries/surgery*
;
Young Adult
;
Aged
;
Hand Bones/injuries*
;
Retrospective Studies
;
Fracture Fixation, Internal
7.Biomechanical study on wing shaped titanium plate fixation of acetabular anterior column and posterior hemi-transverse fracture under multiple working conditions.
Jianwu ZHANG ; WURIKAIXI AIYITI ; Gang LYU ; MAIMAIAILI YUSHAN ; Zhiqiang MA ; Chao MA
Journal of Biomedical Engineering 2025;42(2):351-358
This article aims to compare and analyze the biomechanical differences between wing-shaped titanium plates and traditional titanium plates in fixing acetabular anterior column and posterior hemi-transverse (ACPHT) fracture under multiple working conditions using the finite element method. Firstly, four sets of internal fixation models for acetabular ACPHT fractures were established, and the hip joint stress under standing, sitting, forward extension, and abduction conditions was calculated through analysis software. Then, the stress of screws and titanium plates, as well as the stress and displacement of the fracture end face, were analyzed. Research has found that when using wing-shaped titanium plates to fix acetabular ACPHT fractures, the peak stress of screws decreases under all working conditions, while the peak stress of wing-shaped titanium plates decreases under standing and sitting conditions and increases under forward and outward extension conditions. The relative displacement and mean stress of the fracture end face decrease under all working conditions, but the values are higher under forward and outward extension conditions. Wing-shaped titanium plates can reduce the probability of screw fatigue failure when fixing acetabular ACPHT fractures and can bear greater loads under forward and outward extension conditions, improving the mechanical stability of the pelvis. Moreover, the stress on the fracture end surface is more conducive to stimulating fracture healing and promoting bone tissue growth. However, premature forward and outward extension rehabilitation exercises should not be performed.
Titanium
;
Bone Plates
;
Humans
;
Acetabulum/surgery*
;
Fracture Fixation, Internal/methods*
;
Biomechanical Phenomena
;
Finite Element Analysis
;
Bone Screws
;
Fractures, Bone/surgery*
;
Stress, Mechanical
;
Working Conditions
8.Three-dimensional binding treatment for avulsion fractures of inferior pole of patella utilizing suture anchor.
Hongqing HE ; Ningkai LI ; Meng LIU ; Jiating LIN ; Qiang WANG ; Yinchang ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):26-31
OBJECTIVE:
To explore the feasibility and effectiveness of suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique for avulsion fractures of the inferior pole of the patella.
METHODS:
A clinical data of 38 patients with avulsion fractures of the inferior pole of the patella, who met the selective criteria and were admitted between September 2021 and April 2023, was retrospectively analyzed. The fractures were treated with suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique in 18 cases (group A) and steel wire tension-band fixation in 20 cases (group B). There was no significant difference in terms of age, gender, cause of fracture, side of fracture, and disease duration between the two groups ( P>0.05). The length of incision, operation time, occurrence of complications, the range of motion of knee joint, and Böstman score of knee joint at last follow-up were recorded. The fracture healing was evaluated through X-ray films and the time of fracture healing was recorded.
RESULTS:
All incisions healed by first intention. The length of incision was significantly shorter in group A than in group B ( P<0.05). There was no significant difference in the operation time between the two groups ( P>0.05). All patients were followed up 12-24 months (mean, 16.1 months). X-ray films showed that all fractures healed and there was no significant difference in the healing time between the two groups ( P>0.05). At last follow-up, the range of motion and Böstman score of the knee joint in group A were significantly better than those in group B ( P<0.05). During follow-up, 1 patient (5.6%) in group A had one anchor mild prolapse and 3 patients (15.0%) occured internal fixation irritation in group B. But there was no significant difference in the incidence of complications between the two groups ( P>0.05).
CONCLUSION
For the avulsion fractures of the inferior pole of the patella, the suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique has advantages of reliable fixation, small incision, avoidance of secondary operation to remove internal fixator, and fewer complications, with definite effectiveness.
Humans
;
Male
;
Female
;
Patella/surgery*
;
Suture Anchors
;
Fracture Fixation, Internal/instrumentation*
;
Adult
;
Retrospective Studies
;
Middle Aged
;
Fractures, Avulsion/surgery*
;
Treatment Outcome
;
Young Adult
;
Range of Motion, Articular
;
Fracture Healing
;
Adolescent
;
Suture Techniques
;
Knee Joint/physiopathology*
9.TiRobot-assisted minimally invasive treatment of coracoid process fractures of scapula.
Yonghong DAI ; Qingyu LI ; Yanhui ZENG ; Zhengjie WU ; Chunpeng ZHAO ; Junqiang WANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):40-46
OBJECTIVE:
To explore effectiveness of TiRobot-assisted screw implantation in the treatment of coracoid process fractures of the scapula.
METHODS:
A retrospective analysis was conducted on the clinical data from 24 patients with coracoid process fractures of the scapula admitted between September 2019 and January 2024 and met selection criteria. Among them, 12 patients underwent TiRobot-assisted screw implantation (robot group) and 12 underwent manual screw implantation (control group) during internal fixation. There was no significant difference ( P>0.05) in baseline data such as gender, age, body mass index, disease duration, cause of injury, coracoid process fracture classification, and proportion of patients with associated injuries between the two groups. The incision length, operation time, intraoperative blood loss, hospital stay, accuracy of screw placement, coracoid process fracture healing time, and complications were recorded and compared, as well as pain visual analogue scale (VAS) score, and Constant-Murley score at last follow-up.
RESULTS:
The intraoperative blood loss and incision length in the robot group were significantly lower than those in the control group ( P<0.05); however, there was no significant difference in operation time and hospital stay between the two groups ( P>0.05). All patients were followed up 8-27 months (mean, 17.5 months), and the difference in follow-up time between the two groups was not significant ( P>0.05). At last follow-up, the VAS score for shoulder pain in the robot group was signifncatly lower compared to the control group, and the Constant-Murley score was significantly higher ( P<0.05). In the robot group, 16 screws were implanted intraoperatively, while 13 screws were implanted in the control group. Radiographic re-evaluation showed that the excellent and good rate of screw implantation was higher in the robot group (93.8%, 15/16) than in the control group (61.5%, 8/13), but the difference in the precision of screw implantation between the two groups was not significant ( P>0.05). Four patients in the robot group and 1 in the control group achieved double screws fixation; however, the difference in achieving double screws fixation between the two groups was not significant ( P>0.05). All fractures healed in both groups with 1 case of malunion in the control group. There was no significant difference in healing time between the two groups ( P>0.05). During follow-up, 1 patient in the control group experienced screw loosening and displacement. There was no significant difference in the incidence of screw loosening and fracture malunion between the two groups ( P>0.05).
CONCLUSION
Compared with manual screw implantation, TiRobot-assisted minimally invasive treatment of coracoid process fractures of the scapula can reduce intraoperative blood loss, shorten incision length, alleviate pain, and obtain better promote shoulder joint functional recovery.
Humans
;
Male
;
Female
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Minimally Invasive Surgical Procedures/instrumentation*
;
Adult
;
Middle Aged
;
Fractures, Bone/surgery*
;
Bone Screws
;
Coracoid Process/surgery*
;
Robotic Surgical Procedures/methods*
;
Scapula/surgery*
;
Treatment Outcome
;
Operative Time
;
Young Adult
;
Length of Stay
;
Blood Loss, Surgical
10.Treatment of irreducible intertrochanteric femoral fractures in elderly by novel bone hook combined with finger-guided technique.
Zenghui ZHANG ; Tichao HAN ; Wei LI ; Yangyang ZHOU ; Junjun LIU ; Nannan LI ; Tiantian REN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):53-58
OBJECTIVE:
To investigate the feasibility and effectiveness of the novel bone hook combined with finger-guided technique in the treatment of irreducible intertrochanteric femoral fractures in elderly.
METHODS:
Between January 2021 and August 2023, 23 elderly patients with irreducible intertrochanteric femoral fractures were treated with the novel bone hook combined with finger-guided technique. There were 10 males and 13 females; the age ranged from 68 to 93 years (mean, 76.2 years). The time from injury to operation ranged from 36 to 76 hours (mean, 51.2 hours). According to the classification standard proposed by TONG Dake et alin 2021, there were 10 cases of typeⅠA, 1 case of typeⅠB, 6 cases of type ⅡA, 4 cases of type ⅡB, and 2 cases of type ⅡC. The operation time, intraoperative blood loss, intraoperative fluoroscopy frequences, and quality of fracture reduction were recorded. The fracture healing time and occurrence of postoperative complications were observed during follow-up. At last follow-up, the Harris scoring system was used to evaluate the hip joint function.
RESULTS:
The operation time was 42-95 minutes (mean, 52.1 minutes). The intraoperative blood loss was 40-420 mL (mean, 126.5 mL). Intraoperative fluoroscopy was performed 14-34 times (mean, 20.7 times). According to the criteria proposed by Chang et al, the quality of fracture reduction was rated as good in 20 cases and acceptable in 3 cases. All patients were followed up 6-20 months (mean, 10.2 months). X-ray film showed that all fractures healed with the healing time of 3.0-5.5 months (mean, 4.0 months). At last follow-up, the Harris score of the hip joint ranged from 82 to 97 points (mean, 90.4 points). Among them, 14 cases were rated as excellent and 9 cases as good. No complication such as coxa vara, cutting of the cephalomedullary nail, nail withdrawal, or nail breakage occurred during follow-up.
CONCLUSION
The treatment of elderly patients with irreducible intertrochanteric femoral fractures by using the novel bone hook combined with finger-guided technique can achieve high-quality fracture reduction and fixation, and has a good effectiveness.
Humans
;
Male
;
Female
;
Aged
;
Aged, 80 and over
;
Hip Fractures/diagnostic imaging*
;
Fracture Fixation, Internal/instrumentation*
;
Fracture Healing
;
Treatment Outcome
;
Operative Time
;
Fracture Fixation, Intramedullary/instrumentation*
;
Bone Nails
;
Postoperative Complications/epidemiology*
;
Feasibility Studies
;
Fingers


Result Analysis
Print
Save
E-mail