1.Study on quality standard of wine-processed Coptidis Rhizoma standard decoction
Huilin YANG ; Kaiwei HUANG ; Yanghua LI ; Suqin CAI ; Shuping XU ; Jiabao WEI ; Hui ZHANG ; Weizhi ZHAO ; Pei TAN
International Journal of Traditional Chinese Medicine 2025;47(9):1285-1292
Objective:To establish the quality standard of the standard decoction of wine-processed Coptidis Rhizoma by studying the extraction rate, fingerprint and component quantitative analysis.Methods:ccording to the Technical Requirements for Quality Control and Standard Formulation of Chinese Medicine Formula Granules, 15 batches of the standard decoction of wine-processed Coptidis Rhizoma were prepared, and the paste rate was determined; HPLC fingerprints of 15 batches of standard decoction of wine-processed Coptidis Rhizoma were established, and evaluated by combining similarity evaluation, clustering analysis, principal component analysis and orthogonal partial least squares discriminant analysis; the contents of berberine, epiberberine, pamadine, and safranine in the samples of the 15 batches were determined and analyzed their transfer rates.Results:A total of 15 batches of standard decoction samples were calibrated with 11 common peaks, referring to the recognition of 8 components. The similarity between the samples and the control product was greater than 0.900; the clustering analysis could cluster the 15 batches of samples into 2 classes; the results of the principal component analysis showed that the cumulative variance contribution rate of the 3 principal component factors was 89.388%; the OPLS-DA screened out the 3 components of the quality difference; the 15 batches of samples out of the paste rate was 15.7% -20.8%, and the mass fractions of berberine, epiberberine, safranine, and palmatine were 18.47%-24.38%, 2.82%-3.49%, 5.08%-6.69%, and 4.84%-6.68%, respectively, with transfer rates of 41.7%-61.7%, 46.9%-68.7%, 39.8%-61.5%, and 43.8%-65.2%.Conclusion:The fingerprint and content determination method established in this study is accurate, stable, simple, and can be used for the quality control and evaluation of the standard decoction of wine-processed Coptidis Rhizoma.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Thiotepa-containing conditioning for allogeneic hematopoietic stem cell transplantation in children with inborn errors of immunity: a retrospective clinical analysis.
Xiao-Jun WU ; Xia-Wei HAN ; Kai-Mei WANG ; Shao-Fen LIN ; Li-Ping QUE ; Xin-Yu LI ; Dian-Dian LIU ; Jian-Pei FANG ; Ke HUANG ; Hong-Gui XU
Chinese Journal of Contemporary Pediatrics 2025;27(10):1240-1246
OBJECTIVES:
To evaluate the safety and efficacy of thiotepa (TT)-containing conditioning regimens for allogeneic hematopoietic stem cell transplantation (HSCT) in children with inborn errors of immunity (IEI).
METHODS:
Clinical data of 22 children with IEI who underwent HSCT were retrospectively reviewed. Survival after HSCT was estimated using the Kaplan-Meier method.
RESULTS:
Nine patients received a traditional conditioning regimen (fludarabine + busulfan + cyclophosphamide/etoposide) and underwent peripheral blood stem cell transplantation (PBSCT). Thirteen patients received a TT-containing modified conditioning regimen (TT + fludarabine + busulfan + cyclophosphamide), including seven PBSCT and six umbilical cord blood transplantation (UCBT) cases. Successful engraftment with complete donor chimerism was achieved in all patients. Acute graft-versus-host disease occurred in 12 patients (one with grade III and the remaining with grade I-II). Chronic graft-versus-host disease occurred in one patient. The incidence of EB viremia in UCBT patients was lower than that in PBSCT patients (P<0.05). Over a median follow-up of 36.0 months, one death occurred. The 3-year overall survival (OS) rate was 100% for the modified regimen and 88.9% ± 10.5% for the traditional regimen (P=0.229). When comparing transplantation types, the 3-year OS rates were 100% for UCBT and 93.8% ± 6.1% for PBSCT (P>0.05), and the 3-year event-free survival rates were 100% and 87.1% ± 8.6%, respectively (P>0.05).
CONCLUSIONS
TT-containing conditioning for allogeneic HSCT in children with IEI is safe and effective. Both UCBT and PBSCT may achieve high success rates.
Humans
;
Retrospective Studies
;
Transplantation Conditioning/methods*
;
Thiotepa/therapeutic use*
;
Hematopoietic Stem Cell Transplantation/adverse effects*
;
Male
;
Female
;
Child, Preschool
;
Infant
;
Child
;
Transplantation, Homologous
;
Graft vs Host Disease
;
Adolescent
8.Standardized scheme for deploying and withdrawing surgical module of new-type tent hospital system
Zeng-biao SU ; Bin-hong PEI ; Er-xiang XU ; Hai-ying CHEN ; Jia-na CHEN ; Jin-shen PAN ; Yi-feng HUANG ; Qian XU
Chinese Medical Equipment Journal 2025;46(2):74-79
Objective To explore the scheme for the deployment and withdrawal of the surgical module of the new-type tent hospital system.Methods A set of standardized scheme for deploying and withdrawing the surgical module of the new-type tent hosital system was proposed and implemented in terms of labor division,operation precedure,operation technique and precaution.The operating time,number of operational errors and number of equipment damages were recorded for each of the five deployment and withdrawal operations before and after the program was executed,and the team members'immediate heart rate,percentage of maximum heart rate(MHR)and rating of perceived exercise(RPE)at the end of the operation were recorded after the program was implemented.SPSS 26.0 software was used for statistical analysis.Results The standardized scheme had the deployment time shortened from(85.15±11.430)min to(58.23±8.513)min,withdrawal time decreased from(65.36±9.369)min to(48.92±7.129)min,with the differences being statistically significant(P<0.05);the numbers of operatio-nal errors and equipment damages were both reduced when compared with those before the implementation of the schemce;the immediate heart rate of the team members at the end of the operation ranged from 43 to 157 beats/min,with an average value of 151.1 beats/min,the individual MHR percentages were from 75%to 87%,with an average value of 81.1%,and the RPE scores were from 14 to 17,with an average value of 15.3,which all could be categorized as moderate-operation intensity.Condusion The standardized deployment and withdrawal scheme for the surgical module meets the needs of actual combat and training assessment,and thus is worthy promoting in medical institutions equipped with the surgical module of the new-type tent hosital system.[Chinese Medical Equipment Journal,2025,46(2):74-79]
9.Guideline for the prevention of intraoperative acquired pressure injury in paraplegic patients with spinal cord injury (version 2025)
Aijun XU ; Shuixia LI ; Bo CHEN ; Mengyuan YE ; Lejiao LANG ; Ning NING ; Lin ZHANG ; Changqing LIU ; Zhonglan CHEN ; Weihu MA ; Weishi LI ; Xiaoning WANG ; Dongmei BIAN ; Jiancheng ZENG ; Xin WANG ; Yuan GAO ; Yaping CHEN ; Jiali CHEN ; Yun HAN ; Xiuting LI ; Yang ZHOU ; Xiaojing SU ; Qiong ZHANG ; Tianwen HUANG ; Ping ZHANG ; Hua LIN ; Xingling XIAO ; Ruifeng XU ; Fanghui DONG ; Bing HAN ; Luo FAN ; Yanling PEI ; Suyun LI ; Xiaoju TAN ; Rongchen GUO ; Yefang ZOU ; Xiaoyun HAN ; Junqin DING ; Yi WANG ; Shuhua DENG ; Jinli GUO ; Yinhua LIANG ; Yuan CEN ; Xiaoqin LIU ; Junru CHEN ; Haiyang YU ; Lunlan LI ; Ying REN ; Yunxia LI ; Jianli LU ; Ying YING ; Lan WEI ; Yin WANG ; Qinhong XU ; Yanqin ZHANG ; Yang LYU ; Shijun ZHANG ; Sui WENJIE ; Sanlian HU ; Shuhong YANG ; Guoqing LI ; Jingjing AN ; Baorong HE ; Leling FENG
Chinese Journal of Trauma 2025;41(6):530-541
Paraplegia caused by spinal cord injury is a serious neurological complication, for which surgery is currently the main treatment method. Due to different surgical approaches, patients are usually expected to maintain a passive prone position for a long time or switch between the supine and prone positions. Affected by multiple factors such as neurogenic sensory disorders, pathological changes in muscle tone and operative duration, the risk of intraoperative acquired pressure injury (IAPI) is significantly increased. Current clinical prevention strategies for IAPI in these patients predominantly focus on localized pressure relief during positioning, lacking systematic, standardized comprehensive prevention protocols or evidence-based guidelines. To address it, Department of Nursing, Orthopedics Branch, China International Exchange and Promotive Association for Medical and Health Care, Spinal Trauma Professional Committee, Orthopedics Branch, Chinese Medical Doctor Association, Nursing Group of Spine and Spinal Cord Professional Committee of Chinese Association of Rehabilitation Medicine organized experts in relevant fields to formulate Guideline for the prevention of intraoperative acquired pressure injury in paraplegic patients with spinal cord injury ( version 2025), based on evidence-based medical evidence and latest research results and clinical practice at home and abroad. Eleven recommendations were put forward from the aspects of preoperative risk assessment, intraoperative prevention strategies, postoperative handover and monitoring, and supportive mechanisms for IAPI prevention, aiming to standardize the prevention measures and management strategies of IAPI in paraplegic patients with spinal cord injury and accelerate the recovery of patients and improve the therapeutic effect.
10.Development of an evaluation indicator system for access to cancer screening services: a Delphi study
Xin WANG ; Ayan MAO ; Xinyi ZHOU ; Pei DONG ; Yanjie LI ; Senyao CAI ; Yujie WU ; Huiyao HUANG ; Guoxiang LIU ; Wanghong XU ; Jiangmei QIN ; Wanqing CHEN ; Jufang SHI
Chinese Journal of Epidemiology 2025;46(2):307-315
Objective:To present an evaluation indicator system for access to cancer screening services.Methods:The evaluation indicator pool was constructed through a scoping review. The theoretical framework was constructed based on the multi-source indicators, and the qualitative expert consultation method was employed to form the initial version of the three-level evaluation indicator system. Delphi expert consultation method was conducted in two rounds to evaluate the relevance, importance, and availability of the proposed evaluation indicator system. The expert positive coefficient, authority coefficient, coordination degree of expert opinions, and concentration of expert opinions were subjected to analysis. Subsequently, the three-level evaluation indicator system for access to cancer screening services was adjusted and determined based on the boundary value method and the open opinions of experts. Finally, the combination weight method was employed to determine the weight.Results:The initial version of the indicator system comprised 3 primary (first-level) indicators, 11 secondary (second-level) indicators, and 46 tertiary (third-level) indicators. Delphi expert consultation was conducted for the initial version, and 17 experts ultimately completed it, exhibiting a positive coefficient of 100% and an authority coefficient of 0.87. In comparison to the initial round of consultation, Kendall's W coefficient ranges (0.15-0.43, all P<0.05) of relevance, importance, and availability scores for each tertiary indicator in the second round exhibited an improvement. The analysis of the importance dimension indicates that expert opinions are also more concentrated, as evidenced by an increase of 8.5% and 7.0% in the proportion of the tertiary indicators with an arithmetic mean above 8 and a full mark ratio above 0.5, respectively. The final evaluation indicator system comprises three primary indicators, with the weights of structure evaluation, process evaluation, and outcome evaluation being 0.338, 0.378, and 0.285, respectively. It also comprises 11 secondary indicators and 45 tertiary indicators. Conclusions:The evaluation indicator system developed in this article can be an effective evaluation tool for quantitative comparison of access to cancer screening services across different populations, cancer types, and before and after intervention. Furthermore, it is recommended that the system undergo continuous optimization concerning its application.

Result Analysis
Print
Save
E-mail