1.Targeting ER lipid raft-associated 1 reveals a coordinated cholesterol-dependent vulnerability in hepatocellular carcinoma
Yiming ZHANG ; Yushan HOU ; Xinxin WANG ; Kaikun XU ; Pei JIANG ; Siqi WANG ; Huimin KANG ; Hu ZHANG ; Jingzhuo JIN ; Xiaofen HUANG ; Zifeng LIU ; Songpeng YANG ; Jiaqi LIU ; Lingqiang ZHANG ; Fuchu HE ; Chunyan TIAN ; Aihua SUN
Clinical and Molecular Hepatology 2026;32(2):866-883
Background/Aims:
Dysregulated cholesterol metabolism is a hallmark of hepatocellular carcinoma (HCC) that drives tumor initiation and progression. However, clinical targeting of cholesterol metabolism has yielded limited benefits due to stringent feedback in tumor cells. Identifying a central mediator capable of restoring cholesterol homeostasis within the cell’s intrinsically fine-tuned regulatory framework is urgently needed.
Methods:
We integrated a proteomic dataset from patients with cholesterol-dysregulated HCC into a global cholesterol metabolic regulatory network to identify potential therapeutic targets for disrupted cholesterol homeostasis. The prognostic significance of the candidate targets was further validated in an independent cohort through immunohistochemistry. Functional and mechanistic studies were conducted in vitro using HCC cell lines and in vivo using mouse models. The pharmacological efficacy of the candidate agent was evaluated in both subcutaneous and orthotopic HCC mouse models.
Results:
ER lipid raft-associated 1 (ERLIN1), a pivotal regulator of cholesterol metabolism reprogramming, was identified as an independent favorable prognostic indicator in HCC. ERLIN1 constrains HCC progression both in vitro and in vivo by stabilizing the INSIG1–SCAP–SREBP2 axis and maintaining the metabolic balance of intracellular cholesterol. Under hypoxia, impaired factor-inhibiting hypoxia-1-dependent hydroxylation of ASB11 at asparagine residues 90 and 92 enhances ASB11-mediated ERLIN1 degradation. Pharmacological targeting of this axis using zoledronic acid (ZoA) attenuated HCC progression by weakening the ASB11–ERLIN1 interaction and restoring cholesterol homeostasis.
Conclusions
ERLIN1 represents a druggable metabolic vulnerability in cholesterol-dysregulated HCC. Targeting the ASB11–ERLIN1 axis with the clinically approved ZoA reestablishes cholesterol homeostasis and offers a promising therapeutic strategy to overcome the current limitations of cholesterol-targeted HCC therapies.
2.Thiotepa-containing conditioning for allogeneic hematopoietic stem cell transplantation in children with inborn errors of immunity: a retrospective clinical analysis.
Xiao-Jun WU ; Xia-Wei HAN ; Kai-Mei WANG ; Shao-Fen LIN ; Li-Ping QUE ; Xin-Yu LI ; Dian-Dian LIU ; Jian-Pei FANG ; Ke HUANG ; Hong-Gui XU
Chinese Journal of Contemporary Pediatrics 2025;27(10):1240-1246
OBJECTIVES:
To evaluate the safety and efficacy of thiotepa (TT)-containing conditioning regimens for allogeneic hematopoietic stem cell transplantation (HSCT) in children with inborn errors of immunity (IEI).
METHODS:
Clinical data of 22 children with IEI who underwent HSCT were retrospectively reviewed. Survival after HSCT was estimated using the Kaplan-Meier method.
RESULTS:
Nine patients received a traditional conditioning regimen (fludarabine + busulfan + cyclophosphamide/etoposide) and underwent peripheral blood stem cell transplantation (PBSCT). Thirteen patients received a TT-containing modified conditioning regimen (TT + fludarabine + busulfan + cyclophosphamide), including seven PBSCT and six umbilical cord blood transplantation (UCBT) cases. Successful engraftment with complete donor chimerism was achieved in all patients. Acute graft-versus-host disease occurred in 12 patients (one with grade III and the remaining with grade I-II). Chronic graft-versus-host disease occurred in one patient. The incidence of EB viremia in UCBT patients was lower than that in PBSCT patients (P<0.05). Over a median follow-up of 36.0 months, one death occurred. The 3-year overall survival (OS) rate was 100% for the modified regimen and 88.9% ± 10.5% for the traditional regimen (P=0.229). When comparing transplantation types, the 3-year OS rates were 100% for UCBT and 93.8% ± 6.1% for PBSCT (P>0.05), and the 3-year event-free survival rates were 100% and 87.1% ± 8.6%, respectively (P>0.05).
CONCLUSIONS
TT-containing conditioning for allogeneic HSCT in children with IEI is safe and effective. Both UCBT and PBSCT may achieve high success rates.
Humans
;
Retrospective Studies
;
Transplantation Conditioning/methods*
;
Thiotepa/therapeutic use*
;
Hematopoietic Stem Cell Transplantation/adverse effects*
;
Male
;
Female
;
Child, Preschool
;
Infant
;
Child
;
Transplantation, Homologous
;
Graft vs Host Disease
;
Adolescent
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Study on quality standard of wine-processed Coptidis Rhizoma standard decoction
Huilin YANG ; Kaiwei HUANG ; Yanghua LI ; Suqin CAI ; Shuping XU ; Jiabao WEI ; Hui ZHANG ; Weizhi ZHAO ; Pei TAN
International Journal of Traditional Chinese Medicine 2025;47(9):1285-1292
Objective:To establish the quality standard of the standard decoction of wine-processed Coptidis Rhizoma by studying the extraction rate, fingerprint and component quantitative analysis.Methods:ccording to the Technical Requirements for Quality Control and Standard Formulation of Chinese Medicine Formula Granules, 15 batches of the standard decoction of wine-processed Coptidis Rhizoma were prepared, and the paste rate was determined; HPLC fingerprints of 15 batches of standard decoction of wine-processed Coptidis Rhizoma were established, and evaluated by combining similarity evaluation, clustering analysis, principal component analysis and orthogonal partial least squares discriminant analysis; the contents of berberine, epiberberine, pamadine, and safranine in the samples of the 15 batches were determined and analyzed their transfer rates.Results:A total of 15 batches of standard decoction samples were calibrated with 11 common peaks, referring to the recognition of 8 components. The similarity between the samples and the control product was greater than 0.900; the clustering analysis could cluster the 15 batches of samples into 2 classes; the results of the principal component analysis showed that the cumulative variance contribution rate of the 3 principal component factors was 89.388%; the OPLS-DA screened out the 3 components of the quality difference; the 15 batches of samples out of the paste rate was 15.7% -20.8%, and the mass fractions of berberine, epiberberine, safranine, and palmatine were 18.47%-24.38%, 2.82%-3.49%, 5.08%-6.69%, and 4.84%-6.68%, respectively, with transfer rates of 41.7%-61.7%, 46.9%-68.7%, 39.8%-61.5%, and 43.8%-65.2%.Conclusion:The fingerprint and content determination method established in this study is accurate, stable, simple, and can be used for the quality control and evaluation of the standard decoction of wine-processed Coptidis Rhizoma.
8.Long-term efficacy of CMV/EBV bivirus-specific T cells for viral co-reactivation after stem cell transplantation.
Xuying PEI ; Meng LV ; Xiaodong MO ; Yuqian SUN ; Yuhong CHEN ; Chenhua YAN ; Yuanyuan ZHANG ; Lanping XU ; Yu WANG ; Xiaohui ZHANG ; Xiaojun HUANG ; Xiangyu ZHAO
Chinese Medical Journal 2025;138(5):607-609
9.Development of an evaluation indicator system for access to cancer screening services: a Delphi study
Xin WANG ; Ayan MAO ; Xinyi ZHOU ; Pei DONG ; Yanjie LI ; Senyao CAI ; Yujie WU ; Huiyao HUANG ; Guoxiang LIU ; Wanghong XU ; Jiangmei QIN ; Wanqing CHEN ; Jufang SHI
Chinese Journal of Epidemiology 2025;46(2):307-315
Objective:To present an evaluation indicator system for access to cancer screening services.Methods:The evaluation indicator pool was constructed through a scoping review. The theoretical framework was constructed based on the multi-source indicators, and the qualitative expert consultation method was employed to form the initial version of the three-level evaluation indicator system. Delphi expert consultation method was conducted in two rounds to evaluate the relevance, importance, and availability of the proposed evaluation indicator system. The expert positive coefficient, authority coefficient, coordination degree of expert opinions, and concentration of expert opinions were subjected to analysis. Subsequently, the three-level evaluation indicator system for access to cancer screening services was adjusted and determined based on the boundary value method and the open opinions of experts. Finally, the combination weight method was employed to determine the weight.Results:The initial version of the indicator system comprised 3 primary (first-level) indicators, 11 secondary (second-level) indicators, and 46 tertiary (third-level) indicators. Delphi expert consultation was conducted for the initial version, and 17 experts ultimately completed it, exhibiting a positive coefficient of 100% and an authority coefficient of 0.87. In comparison to the initial round of consultation, Kendall's W coefficient ranges (0.15-0.43, all P<0.05) of relevance, importance, and availability scores for each tertiary indicator in the second round exhibited an improvement. The analysis of the importance dimension indicates that expert opinions are also more concentrated, as evidenced by an increase of 8.5% and 7.0% in the proportion of the tertiary indicators with an arithmetic mean above 8 and a full mark ratio above 0.5, respectively. The final evaluation indicator system comprises three primary indicators, with the weights of structure evaluation, process evaluation, and outcome evaluation being 0.338, 0.378, and 0.285, respectively. It also comprises 11 secondary indicators and 45 tertiary indicators. Conclusions:The evaluation indicator system developed in this article can be an effective evaluation tool for quantitative comparison of access to cancer screening services across different populations, cancer types, and before and after intervention. Furthermore, it is recommended that the system undergo continuous optimization concerning its application.
10.MR ultrashort echo time and T1W sequences for detecting bone erosions of gouty arthritis
Tong YU ; Xiaoli LI ; Pei NIE ; Ying CHEN ; Lin HAN ; Meihan CHEN ; Fengjiao LI ; Xin HUANG ; Changgui LI ; Wenjian XU
Chinese Journal of Medical Imaging Technology 2025;41(3):452-456
Objective To compare the value of ultrashort echo time(UTE)and T1W sequences for detecting bone erosions of gouty arthritis.Methods Forty-four gouty patients were prospectively enrolled,including 32 cases with affected feet and 12 cases with affected knee.MR UTE and T1W sequence scanning of the affected area were performed,and subjectively scoring of imaging quality of 2 kinds of MRI were evaluated,respectively.Then total number and total score of bone erosions of each case were calculated according to all affected bones.Taken DECT as reference standard,the efficacy of UTE and T1WI for detecting bone erosions was assessed through comparing with DECT using Kappa coefficient.Results The imaging quality score of T1WI was lower than that of DECT(all P<0.05),while no significant difference was found between UTE and DECT(all P>0.05).There was high agreement between UTE and DECT for detecting bone erosions(κ=0.949),while the agreement between T1WI and DECT ranged from good to high(κ=0.718 to 0.805).The total number and total score of bone erosions based on T1WI were significantly lower than those based on DECT(all P<0.05),while no significant difference was found between UTE and DECT(all P>0.05).Conclusion UTE was better than T1WI for detecting bone erosions of gouty arthritis.

Result Analysis
Print
Save
E-mail