1.Current quality status and management countermeasures of occupational health technical services in Zhejiang Province
Qiuliang XU ; Feng HAN ; Peng WANG ; Zhen ZHOU ; Fei LI ; Hongwei XIE ; Yong HU ; Weiming YUAN ; Lifang ZHOU ; Hua ZOU
Journal of Environmental and Occupational Medicine 2026;43(3):341-346
Background The quality of occupational health technical services is directly linked to the protection of workers' health rights and the efficacy of occupational disease prevention and control. However, the industry still faces critical challenges: sporadic instances of institutional non-compliance and persistent irregularities in professional practice continue to undermine overall service performance. Objective To assess the current quality status of occupational health technical services in Zhejiang Province and propose countermeasures for quality improvement, providing a scientific basis for policy optimization and service delivery quality enhancement. Methods A total of 69 occupational health technical service institutions in Zhejiang Province that obtained formal accreditation as of April 30, 2024, were sampled, including 3 public institutions and 66 private institutions (comprising 3 formerly Class-A, 28 formerly Class-B, 11 formerly Class-C, and 24 newly certified institutions). Following the Technical Protocol for Quality Monitoring of Occupational Health Technical Service in Zhejiang Province and the Technical Protocol for Proficiency Testing of Occupational Health Detection in Zhejiang Province, a quality assessment task force comprising national and provincial experts was established. Evaluation was conducted across four dimensions: qualification maintenance and compliance, standardization of technical services, authenticity of technical services, and proficiency testing, utilizing a combination of document review, on-site inspections, and technical skill assessments. Results The occupational health technical service institutions in Zhejiang Province were predominantly private entities (82.5%), with significant disparities in overall service quality. The pass rates for qualification maintenance and compliance, technical service standardization, technical service authenticity, and the excellence rate for laboratory proficiency testing were 81.5%, 80.7%, 97.3%, and 90.4%, respectively. Regarding qualification maintenance, the pass rates for "environmental conditions" (49.8%, 56.7%) and "instrumentation and equipment" (58.2%、65.6%) were significantly lower for formerly Class-C and newly certified institutions compared to other categories. In terms of technical standardization, "standardized on-site inspections" recorded the lowest pass rate (67.4%), with newly certified institutions at only 48.0%. Regarding technical service authenticity, formerly Class-C institutions exhibited issues such as missing raw chromatograms for blank samples (85.7% pass rate). In laboratory proficiency testing, public and formerly Class-A institutions achieved 100% excellence rates, but the performance of formerly Class-C and newly certified institutions was comparatively weak; specifically, the failure rate for organic analysis in formerly Class-C institutions reached 20%; the failure rate for dust testing items in newly certified institutions was 10.3%. Conclusion The overall quality of occupational health technical services in Zhejiang Province still requires significant improvement, particularly in basic institutional conditions, the standardization of on-site inspections, and laboratory proficiency in organic and dust analysis. Formerly Class-C and newly certified institutions should be the primary focus of quality management efforts. Differentiated regulatory strategies are recommended, alongside strengthening interim and ex-post supervision to gradually enhance the quality of occupational health technical services across all institutions.
2.The Specificity of Electroacupuncture at Different Acupoints in Promoting Cerebrospinal Fluid Flow in Mice
Yu SHI ; Qian HUA ; Tian-Tian PENG ; Yu-Xin NIE ; Zhao-Heng LIU ; Chen-Geng DENG ; Xu WANG
Progress in Biochemistry and Biophysics 2026;53(5):1154-1164
ObjectiveCerebrospinal fluid (CSF) plays a crucial role in maintaining the homeostasis of the central nervous system (CNS). CSF rapidly exchanges with interstitial fluid (ISF) via the glymphatic system within the brain parenchyma. CSF-ISF circulation and its associated mechanisms are often referred to as the brain lymphatic system. This system is connected directly to meningeal lymphatic vessels (mLVs), jointly performing the function of clearing metabolic waste from the CNS. Emerging evidence indicates that this system is closely associated with the onset and progression of neurodegenerative diseases (NDs) such as Alzheimer’s disease (AD). Importantly, abnormal CSF circulation is not only a downstream consequence of AD pathology, but also a risk factor. In AD, the dynamics of CSF flow within the CNS are diminished, immune dysregulation occurs, and this may increase the risk of AD by exacerbating the burden of amyloid β-protein (Aβ). In the mouse model of AD, impaired CSF flow compromises this clearance function, leading to cognitive deficits. Clinically, acupuncture at cognition-related acupoints is commonly used for the prevention and treatment of AD. However, whether its therapeutic effects are mediated through the modulation of CSF dynamics remains unclear. This study aimed to evaluate the impact of acupuncture on CSF flow and investigate its acupoint specificity. MethodsMice were randomly assigned to experimental groups for the different electroacupuncture groups with the following acupoints: Baihui point (GV 20), Ear point, Neiguan point (PC 6), and Tianshu point (ST 25). Wild-type mice on a C57BL/6J background were used as controls. Fluorescent tracer was injected into the cisterna magna to label CSF flow. Fluorescence imaging was employed to assess the distribution of CSF within the brain before and after acupuncture stimulation. ResultsFollowing tracer injection into the cisterna magna, fluorescence signals rapidly reached the cerebellum and medulla—the regions closest to the injection site. Fluorescence intensity was higher in ventral brain regions compared to dorsal regions, likely due to greater vascular density in ventral areas facilitating CSF-ISF exchange. Electroacupuncture at the GV 20 produced the most pronounced enhancement of CSF across the whole brain, while stimulation at the ST 25 primarily augmented flow within subcortical regions. In contrast, electroacupuncture at the Ear point or the PC 6 had no observable effect on CSF in mice. ConclusionElectroacupuncture promotes CSF flow into the brain parenchyma in an acupoint-specific manner, with GV 20 exhibiting the most pronounced enhancement of CSF dynamics. These findings suggest that acupuncture-mediated facilitation of CSF flow may represent a potential therapeutic strategy for preventing or delaying age-related cognitive decline.
3.The Specificity of Electroacupuncture at Different Acupoints in Promoting Cerebrospinal Fluid Flow in Mice
Yu SHI ; Qian HUA ; Tian-Tian PENG ; Yu-Xin NIE ; Zhao-Heng LIU ; Chen-Geng DENG ; Xu WANG
Progress in Biochemistry and Biophysics 2026;53(5):1154-1164
ObjectiveCerebrospinal fluid (CSF) plays a crucial role in maintaining the homeostasis of the central nervous system (CNS). CSF rapidly exchanges with interstitial fluid (ISF) via the glymphatic system within the brain parenchyma. CSF-ISF circulation and its associated mechanisms are often referred to as the brain lymphatic system. This system is connected directly to meningeal lymphatic vessels (mLVs), jointly performing the function of clearing metabolic waste from the CNS. Emerging evidence indicates that this system is closely associated with the onset and progression of neurodegenerative diseases (NDs) such as Alzheimer’s disease (AD). Importantly, abnormal CSF circulation is not only a downstream consequence of AD pathology, but also a risk factor. In AD, the dynamics of CSF flow within the CNS are diminished, immune dysregulation occurs, and this may increase the risk of AD by exacerbating the burden of amyloid β-protein (Aβ). In the mouse model of AD, impaired CSF flow compromises this clearance function, leading to cognitive deficits. Clinically, acupuncture at cognition-related acupoints is commonly used for the prevention and treatment of AD. However, whether its therapeutic effects are mediated through the modulation of CSF dynamics remains unclear. This study aimed to evaluate the impact of acupuncture on CSF flow and investigate its acupoint specificity. MethodsMice were randomly assigned to experimental groups for the different electroacupuncture groups with the following acupoints: Baihui point (GV 20), Ear point, Neiguan point (PC 6), and Tianshu point (ST 25). Wild-type mice on a C57BL/6J background were used as controls. Fluorescent tracer was injected into the cisterna magna to label CSF flow. Fluorescence imaging was employed to assess the distribution of CSF within the brain before and after acupuncture stimulation. ResultsFollowing tracer injection into the cisterna magna, fluorescence signals rapidly reached the cerebellum and medulla—the regions closest to the injection site. Fluorescence intensity was higher in ventral brain regions compared to dorsal regions, likely due to greater vascular density in ventral areas facilitating CSF-ISF exchange. Electroacupuncture at the GV 20 produced the most pronounced enhancement of CSF across the whole brain, while stimulation at the ST 25 primarily augmented flow within subcortical regions. In contrast, electroacupuncture at the Ear point or the PC 6 had no observable effect on CSF in mice. ConclusionElectroacupuncture promotes CSF flow into the brain parenchyma in an acupoint-specific manner, with GV 20 exhibiting the most pronounced enhancement of CSF dynamics. These findings suggest that acupuncture-mediated facilitation of CSF flow may represent a potential therapeutic strategy for preventing or delaying age-related cognitive decline.
4.Nontarget Screening and Identification of Novel Per-and Polyfluoroalkyl Substances in Cosmetics Using Ultra-High Performance Liquid Chromatography-High-Resolution Mass Spectrometry
Xin-Ling LI ; Tao YANG ; Wen-Yao LIANG ; Jian-Hua TAN ; Xian-Zhi PENG
Chinese Journal of Analytical Chemistry 2025;53(4):640-651,中插23-中插28
Cosmetics may be an important source of human exposure to per-and polyfluoroalkyl substances(PFASs),posing risks to human health.In this study,a nontarget screening method for PFASs in cosmetics was developed using ultra-high performance liquid chromatography-high-resolution mass spectrometry(UHPLC-Q-Orbitrap HRMS)based on the Kendrick mass defect(KMD).The sample was extracted by ultrasonic assisted extraction prior to being analyzed by UHPLC-Q-Orbitrap HRMS.Acquisition of HRMS data was achieved in both full scan and data-dependent(Full MS/dd MS2)mode.The data collected by HRMS were imported into an in-lab built R script for processing.Samples retained the mass spectra peaks with KMD values in the range of 0.85-1 or 0-0.15 for in-and out-of-library matching;when KMD deviation(δKMD)<0.001 and CF 2 mass error(δMS)<15 ppm,it was considered as a potential PFASs homologues.According to matches of parent ions(MS),fragment ions(MS2)and retention time(RT)with the in-house built PFASs database,the screened and identified potential PFASs were categorized to 5 confidence levels(CL1-CL5).A total of 15 kinds of PFASs homologues with confidence level of CL3 and above were screened from 13 cosmetics products and 8 cosmetic raw materials,including perfluoroalkyl alcohol,hydroperfluoroalkyl sulfonic acid,chloroperfluoroalkyl sulfonic acid,etc.with concentrations ranging from 1.9 ng/g to 98.1 ng/g.The nontarget screening method could be used to screen and identify PFASs homologues feasibly and therefore provided data basis for management and control of PFASs addition in cosmetics.
5.Research Progress on Electrochemical Sensing Techniques for Detection of Telomerase Activity
Hai-Tang YANG ; Peng-Hua SHU ; Wen-Lin LIU ; Wen-Bo MA ; Zi-Jun YANG ; Zhi-Feng DENG ; Xin-Yun ZHANG ; Wei WEI
Chinese Journal of Analytical Chemistry 2025;53(6):864-874
The telomere structure in the cell nucleus is crucial for maintaining the stability and functions of chromosomes.Telomerase is a ribonucleoprotein reverse transcriptase,which catalyzes the elongation of telomeres using its own RNA as a template,thereby counteracting the shortening of telomeres caused by chromosome replication and cell division.Due to its overexpression in over 85%of malignant tumor cells,telomerase has emerged as a highly promising biomarker and a novel target for cancer therapy.In recent years,given the importance of precise quantification of telomerase activity in guiding medical diagnosis and treatment strategies,researchers have developed various high-performance telomerase detection techniques.Among these,electrochemical biosensing technique has cause much attention due to its high sensitivity,operational convenience,rapid response,and ease of miniaturization.This paper focused on the latest advances in electrochemical sensing technique for detection of telomerase activity,aiming to provide inspiration for designing novel telomerase activity detection strategies by elucidating three unique properties of telomerase primer extension products.
6.Advances in Dual-response Adenosine Triphosphate Fluorescent Probes for Bioimaging
Qing-Yu XU ; Xiang LI ; Wei CAO ; Zhi-Hua PENG ; Jing-Bin ZENG
Chinese Journal of Analytical Chemistry 2025;53(8):1213-1225
Adenosine triphosphate(ATP),as the core energy metabolism molecule in living systems,has dynamic changes closely related to fundamental physiological processes.To meet the urgent demand for spatiotemporal ATP detection in vivo and in situ,the development of highly sensitive multifunctional synchronous sensing fluorescent probes has become a recent research focus.These dual-function probes achieve fluorescence detection of dual targets by designing recognition sites for ATP alongside biological factors or microenvironment parameters such as reactive oxygen/nitrogen/sulfur species,metal ions,and enzymes,enabling physiological/pathological state correlation analysis through bioimaging.This paper systematically reviews recent advances in fluorescent probes for the collaborative detection of ATP and key biomolecules.It specifically examines probe construction strategies based on specific molecular recognition mechanisms(e.g.,metal coordination competition,electrostatic interactions,and host-guest recognition),multi-modal optical signal transduction mechanisms(ratiometric fluorescence,fluorescence lifetime,and photodynamic therapy),and their applications in pathological models such as oxidative stress monitoring,metal homeostasis imbalance,and enzyme activity co-detection.Finally,from the perspective of molecular probe engineering,current challenges and future research directions are proposed to provide methodological support for precise analysis of ATP-related life process regulation networks.
7.Determination of Organic Fluorinated Amines in Oral Care Products by Ultra Performance Liquid Chromatography-Charged Aerosol Detector Coupled with Solid-Phase Extraction
Xiao-Fang LI ; Yan PENG ; Di XIN ; Wei ZHOU ; Xiao-Hong QIAO ; Hua-Jin SHI ; Lei ZHANG ; Guo-Qiang CAI ; Ying LIU
Chinese Journal of Analytical Chemistry 2025;53(8):1362-1370,中插100-中插105
The major components of Olaflur raw material were characterized using ultra performance liquid chromatography-quadrupole time-of-flight-mass spectrometry(UPLC-Q-TOF/MS).The results revealed that cetyl amine fluoride(C16-AmF),octadecene amine fluoride(C18:1-AmF),and octadecyl amine fluoride(Olaflur)were the main components.The contents of C16-AmF,C18:1-AmF,and Olaflur in oral care products were determined via ultra performance liquid chromatography-charged aerosol detector coupled with solid-phase extraction(SPE-UPLC-CAD).The oral care sample was dispersed evenly with a 50%ethanol aqueous solution,and then vortexed with ethanol.The supernatant was collected by centrifugation,concentrated to near dryness,and redissolved with ultrapure water.The re-dissolved sample was loaded onto a Poly-Sery HLB Pro SPE column for purification and elution.The acetonitrile eluate was collected and concentrated to 1.0 mL.Finally,a prepared test solution was separated on a Thermo Acclaim Surfactant Plus chromatographic column(2.1 mm×150 mm,3 μm).Acetonitrile and 100 mmol/L acetic acid-ammonium acetate aqueous solution(pH=4.8)were used as the mobile phases for gradient elution.The flow rate was 0.3 mL/min and cloumn temperature was maintained at 40℃.The sample was detected using a charged aerosol detector,and quantified using an external standard method.The experimental results indicated that the three organic fluorinated amines showed good linear relationship in their respective concentration ranges.The correlation coefficients(r)were greater than 0.99.The limit of detection(LOD)and the limit of quantification(LOQ)of C16-AmF were 2.0 and 8.0 μg/mL,respectively.The LOD and LOQ of C18:1-AmF were 2.0 and 8.0 μg/mL,respectively.The LOD and LOQ of Olaflur were 3.0 μg/mL and 10.0 μg/mL,respectively.The spiked recoveries of the three organic fluorinated amines were 84.3%-104.2%,with relative standard deviations(RSDs)of 4.93%-5.82%.The 28 batches of commercial oral care samples were detected by this method and the results indicated that three organic fluorinated amines were detected in 18 samples and the total content were 22.2-11477.8 μg/g.This method had high sensitivity and good reproducibility.It was suitable for verifying the authenticity of the claims of oral care products promoted with Olaflur as the main efficacy ingredient and selling point,and provided a valuable reference for establishing and improving the standard analytical method for Olaflur.
8.A Sensitive Lateral Flow Immunoassay for Detection of Interleukin-6 Using Carbon Dots-Mesoporous Silica Nanocomposite Fluorescent Probes
Yue-Qian YANG ; Peng-Yue WANG ; Jia-Qi REN ; Xiao PAN ; Feng-Hua TAN ; Yu-Jie MA ; Cong-Ying WEN ; Jing-Bin ZENG
Chinese Journal of Analytical Chemistry 2025;53(9):1467-1475
In this study,a sensitive lateral flow immunoassay(LFIA)platform based on carbon dots-mesoporous silica nanocomposite(CD-MSNs)fluorescent probes was constructed for high-performance detection of inflammatory marker interleukin-6(IL-6).Green fluorescent carbon dots(CDs)were prepared by hydrothermal method with 3,9-perylenic acid and 3-aminopropyltriethoxysilane(APTES)as raw materials,and highly fluorescent CD-MSNs composites were then constructed by encapsulating the prepared CDs in mesoporous silica nanoparticles(MSNs).Fluorescent probes were prepared by covalent coupling of CD-MSNs with IL-6 antibody.Fluorescent immunochromatographic test strips were constructed by spraying IL-6 capture antibody and goat anti-mouse IgG on nitrocellulose membrane as detection line(T-line)and quality control line(C-line),respectively.The fluorescence immunoassay analyzer was used to quantitatively detect the fluorescence intensity of T-line,and the experimental results showed that the LFIA platform based on this probe had a good linear relationship in IL-6 concentration range of 102-106 pg/mL,and the detection limit was 64 pg/mL,which was two orders of magnitude more sensitive than that of the traditional colloidal gold test strips.This method effectively solved the issue of insufficient sensitivity of traditional LFIA technique,and provided a rapid and highly sensitive detection method for early diagnosis of inflammatory diseases.
9.Exploration on the diuretic mechanism of Zhuling Decoction on ADRN mice from CDK18/STUB1/AQP2 pathway
Wenfeng XU ; Fan WU ; Yajun PENG ; Qun TANG ; Xuhua LI ; Hua HU
International Journal of Traditional Chinese Medicine 2025;47(5):624-629
Objective:To observe the diuretic effects of Zhuling Decoction on mice with adriamycin nephropathy (ADRN); To explore its mechanism.Methods:Totally 32 SPF male C57BL/6 mice were divided into a blank group of 7 mice and a model group of 25 mice using a random number table method. ADRN model was prepared by single tail vein injection of 0.01 g/kg of amphotericin. Two weeks later, the successfully modeled mice were divided into a model group (7 mice), a furosemide group (8 mice), and a Zhuling Decoction group (8 mice). The blank group and model group mice were given equal volumes of injection water by gavage. The furosemide group was given 2.6 mg/kg of furosemide by gavage, and the Zhuling Decoction group was given 6.5 g/kg of Zhuling Decoction by gavage, once a day, for 8 consecutive weeks. Changes in body weight and urine output of mice were observed. A biochemical analyzer was used to detect 24-hour urinary protein quantification and blood potassium and SCr levels in mice. HE staining was used to observe pathological changes in mouse kidneys, and immunohistochemistry and Western blot were used to detect the homology of cyclin dependent kinase 18 (CDK18), STIP1, and the expressions of U-box protein 1 (STUB1) and aquaporin 2 (AQP2) in mouse kidney tissue cells.Results:Compared with the model group, both the furosemide and Zhuling Decoction groups exhibited increased 24-hour urine output ( P<0.05); compared with the model group and furosemide group, Zhuling Decoction group showed reduced average optical density values and protein expressions of CDK18 and AQP2 ( P<0.05) and increased STUB1 average optical density value and protein expression ( P<0.05). Conclusion:Zhuling Decoction can increase 24-hour urine output in ADRN mice, and the mechanism may be related to down-regulation of CDK18 and AQP2 protein expressions and up-regulation of STUB1 protein expression, thereby modulating the CDK18/STUB1/AQP2 pathway and reducing water reabsorption.
10.An Amphibians-Derived Protein Provides Novel Biotherapeutics for Various Wounds Treatment
Hao-Ran CHEN ; Nan ZHOU ; Yu-Da LIU ; Li-Hua PENG
Biomolecules & Therapeutics 2025;33(2):399-407
Acute burns and chronic wounds frequently fail to heal owing to various reasons. Most drugs currently used for wound therapy in clinical practice have notable drawbacks, making their application a substantial concern. For instance, anti-inflammatory drugs can exert multisystem toxicity, and cellular therapies are costly and difficult to retain. In recent years, natural functional proteins derived from animals and plants have gained increasing attention owing to their unique biological activities, low cost, and broad application prospects in wound therapy. Herein, we isolated a new protein (JH015Y) from amphibians and demonstrated its excellent wound repair and regeneration properties compared with those of epidermal growth factor, both in vitro and in vivo. JH015 protein increased the proliferative ability of human keratinocytes and skin fibroblasts by 47.73 and 41.40%, respectively. In vivo, the medium-dose (0.5 mg/dose) groups of JH015Y protein demonstrated accelerated wound healing from day 4, with wound healing rates 1.26, 1.27, and 1.14 times that of the blank group in acute wounds, burn wounds, and diabetic ulcer, respectively. Histological analysis of Masson-stained sections indicated that the JH015Y protein contributed to collagen deposition on the wound surface, markedly reduced inflammatory cell infiltration, and exhibited low biological toxicity. Accordingly, the JH015Y protein is a promising biotherapeutic agent for accelerated wound repair and regeneration.

Result Analysis
Print
Save
E-mail