1.An exploratory study on the effect of ultrasonic waves against Aedes albopictus larvae
Shuqing JIN ; Xinyi CAI ; Heyi WEN ; Jian FAN ; Hui CAO ; Tianyu SHA ; Hongxia LIU ; Yuan FANG ; Qiang GAO
Shanghai Journal of Preventive Medicine 2026;38(7):550-555
ObjectiveTo evaluate the larvicidal effect of ultrasonic waves against Aedes albopictus larvae at various exposure parameters (distance and time), and to preliminarily investigate the effects of different containers (water volume and depth) and ultrasonic devices on the larvicidal efficacy, so as to provide experimental evidence for the application of ultrasound-based mosquito control technology. MethodsUnder controlled laboratory conditions, two commercially available ultrasonic devices [40 kHz/300 W and (50±5) kHz/70 W] were used to systematically examine the effects of exposure distance (20, 40, 60, 80, and 100 cm), exposure duration (1, 3, 6, 15 and 60 min), larval instar(Ⅰ‒Ⅱ and Ⅲ‒Ⅳ), and container type on the immediate mortality of Aedes albopictus larvae collected from urban areas of Shanghai. Statistical analysis of the mortality rates of larvae among different experimental groups was performed using the chi-square test. ResultsUltrasonic exposure exerted a detectable larvicidal effect against Aedes albopictus larvae of all instars. For early-instar larvae, exposure time significantly affected mortality at all tested distances (20, 40, 60, 80 and 100 cm), with χ² values ranging from 25.57 to 32.74 ( all P<0.001). No significant distance effect was observed in the first and second instar larvae after short-term exposure (1 and 3 min; P>0.05). However, a distance-dependent effect emerged from 6 min onward (P<0.05). During short-term exposure (1 min and 3 min) at close range (20 cm and 40 cm), the immediate mortality of the third and fourth instar larvae was higher than that of the first and second instar larvae. Conversely, during prolonged exposure (15 min and 60 min), the first and second instar larvae exhibited significantly higher mortality than that of the third and fourth instar larvae. These results indicated that larval mortality was jointly influenced by exposure duration and distance. Preliminary experiments indicated that larvicidal efficacy in shallow water was lower than that in deep water. No significant difference in larvicidal effect was observed between the two ultrasonic devices with different frequencies and power outputs. ConclusionUnder laboratory conditions, ultrasound can effectively kill Aedes albopictus larvae, and the larvicidal effect is jointly influenced by larval instar, exposure distance, and aquatic environment. Compact ultrasonic devices show potential for field application in biological mosquito control.
2.Comparison of Acute Hemodynamics,Left Ventricular Fluid and Energy Losses Between Different Pacing Sites of the Cardiac Conduction System in Beagles
Yiran HU ; Han JIN ; Hui LI ; Sijing CHENG ; Sixian WENG ; Hao HUANG ; Juwei YANG ; Yu YU ; Ligang DING ; Min GU ; Hongxia NIU ; Wei HUA
Chinese Circulation Journal 2025;40(1):82-89
Objectives:Comparative analysis of the beagles acute-phase electrocardiographic,hemodynamic,left ventricular flow field status,and energy consumption characteristics of pacing at different sites of conduction system may help to elucidate the scientific mechanism of left bundle branch pacing(LBBP)as a option of physiological pacing therapy.Methods:Eight healthy adult beagles were used in this study.Initially,an active fixation lead was implanted in the right atrial appendage,followed by implantation of another active fixation lead at the right ventricular apex,distal His bundle,and left bundle septal branch,respectively.After connecting a dual-chamber pacemaker,electrocardiographic and acute phase hemodynamic parameters under sinus rhythm,right ventricular apex pacing(RVAP),distal His bundle pacing(DHBP),and LBBP states were collected and analyzed.Three complete cardiac cycles of standard apical three-chamber color Doppler dynamic images were acquired under vector flow mapping(VFM)mode.Offline analysis was performed on obtained parameters including isovolumic contraction period,rapid ejection period,isovolumic relaxation period,rapid filling period,atrial contraction period,and left ventricular intracavitary energy consumption.These parameters were compared under pacing at different sites and the linear correlations of major parameters were analyzed.Results:The QRS duration of baseline intrinsic sinus rhythm,RVAP,DHBP and LBBP were(45.0±4.0)ms,(98.4±6.2)ms,(50.0±4.5)ms and(62.0±4.7)ms,respectively.The LBBP-QRS duration was significantly wider than intrinsic sinus rhythm and DHBP,but significantly narrower than RVAP(all P<0.01).Compared with baseline AOO mode(the pacing rate was performed at 10 beats/min above the intrinsic heart rate),the change of acute phase maximum left ventricular pressure rise rate(LVdP/dtmax)in RVAP,DHBP and LBBP was([-7.89±5.67]% ),([0.74±2.05]% )and([-0.14±3.59]% ),respectively.There was no significant difference in LVdP/dtmax changes between DHBP and LBBP(P=0.667),but both pacing modalities were significantly better than RVAP(all P<0.01).The average energy consumption of the left ventricle under RVAP was significantly higher than that of intrinsic sinus rhythm,DHBP,and LBBP in isovolumic contraction period,rapid ejection period,isovolumic relaxation period,rapid filling period,and atrial contraction period(all P<0.01).However,there was no statistically significant difference in energy consumption among intrinsic sinus rhythm,DHBP,and LBBP during the above five phases(all P>0.05).DHBP and LBBP did not show a significant increase in the number of left ventricular vortices,vortex area,and circulation intensity compared to intrinsic sinus rhythm,and LBBP did not show a significant increase in vortex area and circulation intensity compared to DHBP.Conclusions:Although LBBP canines significantly prolonged the paced QRS duration,it showed no significant differences in acute phase left ventricular hemodynamics,left ventricular flow field status,and energy consumption compared to intrinsic sinus rhythm and DHBP.Performance of LBBP was superior to RVAP.This study may contribute to revealing the theoretical basis of LBBP as a feasible physiological pacing therapy.
3.Strengthening the Construction of Clinical Quality Control System for MRI Equipment to Ensure Their Efficacy in Clinical Application
Hongxia YIN ; Chengwei LI ; Yawen LIU ; Hui XU ; Yu ZHANG ; Zhenchang WANG
Chinese Journal of Medical Imaging 2025;33(6):583-586
With the rapid increase in the ownership of MRI equipment in China,quality control,particularly in clinical usage aspects,has become critically important.For clinical quality control of MRI systems,it is essential to establish comprehensive workflow principles encompassing multiple elements such as personnel,equipment,standards,tools and methodologies.To advance the standardization and widespread adoption of clinical quality control for MRI equipment,efforts must focus on strengthening regulatory frameworks,advancing phantom research,development and enhancing professional expertise.Concurrently,continuous improvements in training programs and supervision mechanisms are necessary to ensure the effective implementation of MRI clinical quality control practices.Furthermore,in the era of digital healthcare,clinical quality assurance for MRI equipment is evolving toward automation and intelligent solutions,providing higher-quality and more efficient assurance for clinical applications.
4.Automatic Measurement Method for Spatial Resolution of MRI Based on the ACR Phantom
Yu ZHANG ; Hongxia YIN ; Yawen LIU ; Pengling REN ; Yanjun HU ; Tianxin CHENG ; Zhenghan YANG ; Zhenchang WANG ; Hui XU
Chinese Journal of Medical Imaging 2025;33(6):595-600,606
Purpose To measure the spatial resolution in MRI quality control testing automatically based on the American College of Radiology(ACR)phantom using the support vector machine(SVM)method,and the feasibility,accuracy and measurement speed of this method are explored.Materials and Methods Quality control tests were performed using eight MRI devices at Beijing Friendship Hospital of Capital Medical University.A retrospective study was conducted on 71 MRI quality control test images collected based on ACR phantoms between 2017 and 2019.The images were preprocessed by binarization,extraction region of interest and so on.An SVM-based classification model was constructed for analyzing the spatial resolution of dot arrays in row and column directions.The dataset was randomly split into a training set and a test set.The generalization performance of the classification model in this study was evaluated through accuracy,precision,recall and F1 score on the test set.Comparing the results of spatial resolution measurements obtained by both manual and automatic method,we demonstrated the feasibility and accuracy of the method.Additionally,the time taken for the automatic spatial resolution measurement was recorded.Results In this study,the proposed method of automatically measuring the spatial resolution of ACR phantom test images using SVM was feasible,high accuracy and short time.In classification performance test,the accuracy of the spatial resolution of the row directional latices was 95%,the precision was 100%.The accuracy of the spatial resolution of the column directional latices was 97%,the precision was 100%.Among the test cases,the results of automatic measurements matched those of manual measurements in 13 out of 14 cases.On average,automatic spatial resolution measurement took 0.158 seconds per case.Conclusion This study achieves automatic measurement of spatial resolution in MRI quality control based on the ACR phantom using SVM method.The method demonstrates high accuracy and fast measurement speeds,holding significant implications for future rapid MRI quality control stability testing.
5.Automatic Detection of Quality Control Performance of Radio Frequency Coils Based on ACR Phantom
Yawen LIU ; Hongxia YIN ; Yu ZHANG ; Pengling REN ; Yanjun HU ; Hui XU ; Zhenghan YANG ; Zhenchang WANG
Chinese Journal of Medical Imaging 2025;33(6):601-606
Purpose To explore an automatic detection method for quality control performance indicators of radio frequency coils based on American College of Radiology(ACR)phantom,and verify its accuracy stability and computational efficiency.Materials and Methods A retrospective study was conducted on 50 quality control images collected based on ACR phantom in Beijing Friendship Hospital,Capital Medical University from May 2017 to July 2019.The measurement and calculation methods of signal noise ratio(SNR),percent image uniformity(PIU)and percent signal ghosting(PSG)were used to automatically calculate the above indicators using a self-designed program in Python.A simple linear regression analysis on the automatically calculated SNR,PSG and PIU values compared to the manually measured results was performed,and Bland-Altman analysis was used to calculate the percentage difference to evaluate the consistency and bias between the performance indicators calculated by the two methods.The time consumption of two detection methods was compared to verify their computational complexity and efficiency.Results There was a strong correlation between the performance indicators SNR,PSG and PIU of radio frequency coils measured and calculated automatically and manually(r=0.991 4,0.992 8 and 0.909 8,all P<0.0001).The Bland-Altman results showed that most of the data fall within the 95%confidence interval and were evenly distributed.In terms of computational complexity and efficiency,compared to the complex manual delineation and calculation of 2-3 minutes per case,automatic detection could simultaneously obtain SNR,PSG and PIU values in less than 1 second.Conclusion The automatic and manual measurement methods have good consistency,and the automatic detection method is easy to operate,which is helpful for the daily quality control work and performance monitoring of radio frequency coils.
6.National bloodstream infection bacterial resistance surveillance report 2023: Gram-positive bacteria
Chaoqun YING ; Jinru JI ; Zhiying LIU ; Qing YANG ; Haishen KONG ; Jiangqin SONG ; Hui DING ; Yanyan LI ; Yuanyuan DAI ; Haifeng MAO ; Pengpeng TIAN ; Lu WANG ; Yongyun LIU ; Yizheng ZHOU ; Jiliang WANG ; Yan JIN ; Donghong HUANG ; Hongyun XU ; Peng ZHANG ; Xinhua QIANG ; Hong HE ; Lin ZHENG ; Junmin CAO ; Zhou LIU ; Ying HUANG ; Yan GENG ; Haiquan KANG ; Dan LIU ; Guolin LIAO ; Lixia ZHANG ; Fenghong CHEN ; Yanhong LI ; Baohua ZHANG ; Haixin DONG ; Xiaoyan LI ; Donghua LIU ; Qiuying ZHANG ; Xuefei HU ; Liang GUO ; Sijin MAN ; Dijing SONG ; Rong XU ; Youdong YIN ; Kunpeng LIANG ; Aiyun LI ; Zhuo LI ; Hongxia HU ; Guoping LU ; Jinhua LIANG ; Qiang LIU ; Yinqiao DONG ; Jilu SHEN ; Shuyan HU ; Liang LUAN ; Jian LI ; Ling MENG ; Dengyan QIAO ; Xiusan XIA ; Bo QUAN ; Dahong WANG ; Chunhua HAN ; Xiaoping YAN ; Fei LI ; Shifu WANG ; Ping SHEN ; Yunbo CHEN ; Yonghong XIAO
Chinese Journal of Clinical Infectious Diseases 2025;18(2):118-132
Objective:To report the nationwide surveillance results of pathogenic profiles and antimicrobial resistance patterns of Gram-positive bloodstream infections in China in 2023.Methods:The clinical isolates of Gram-posttive bacteria from blood cultures were collected in member hospitals of National Bloodstream Infection Bacterial Resistant Investigation Collaborative System(BRICS)during January to December 2023. Antimicrobial susceptibility testing was performed using the dilution method recommended by the Clinical and Laboratory Standards Institute(CLSI). Statistical analyses were conducted using WHONET 5.6 and SPSS 25.0 software.Results:A total of 4 385 Gram-positive bacterial isolates were obtained from 60 participating center. The top five pathogens were Staphylococcus aureus( n=1 544,35.2%),coagulase-negative Staphylococci( n=1 441,32.9%), Enterococcus faecium( n=574,13.1%), Enterococcus faecalis( n=385,8.8%),and α-hemolytic Streptococci( n=187,4.3%). The prevalence of methicillin-resistant Staphylococcus aureus(MRSA)and methicillin-resistant coagulase-negative Staphylococci(MRCNS)was 26.2%(405/1 544)and 69.8%(1 006/1 441),respectively. Notably,all Staphylococci remained susceptible to glycopeptide or daptomycin. Staphylococcus aureus demonstrated excellent susceptibility(>97.0%)to cephalobiol,rifampicin,trimethoprim-sulfamethoxazole,linezolid,minocycline,tigecycline,and eravacycline. No Enterococcus exhibiting resistance to linezolid were detected. Glycopeptide resistance was uncommon but more frequent in Enterococcus faecium(resistance to vancomycin and teicoplanin:both 1.7%)compared to Enterococcus faecalis(both 0.3%). The detection rates of MRSA and MRCNS exhibited significant regional variations across the country( χ2=17.674 and 148.650,respectively,both P<0.001). No vancomycin-resistant Enterococci were detected in central China. Institutional comparison demonstrated higher prevalence of MRSA( χ2=14.111, P<0.001)and MRCNS( χ2=4.828, P=0.028)in provincial hospitals than that in municipal hospitals. Socioeconomic analysis identified elevated detection rates of both MRSA( χ2=18.986, P<0.001)and MRCNS( χ2=4.477, P=0.034)in less developed regions(per capita GDP
7.National bloodstream infection bacterial resistance surveillance report (2023) : Gram-negative bacteria
Jinru JI ; Zhiying LIU ; Chaoqun YING ; Qing YANG ; Haishen KONG ; Jiangqin SONG ; Hui DING ; Yanyan LI ; Yuanyuan DAI ; Haifeng MAO ; Pengpeng TIAN ; Lu WANG ; Yongyun LIU ; Yizheng ZHOU ; Jiliang WANG ; Yan JIN ; Donghong HUANG ; Hongyun XU ; Peng ZHANG ; Xinhua QIANG ; Hong HE ; Lin ZHENG ; Junmin CAO ; Zhou LIU ; Ying HUANG ; Yan GENG ; Haiquan KANG ; Dan LIU ; Guolin LIAO ; Lixia ZHANG ; Fenghong CHEN ; Yanhong LI ; Baohua ZHANG ; Haixin DONG ; Xiaoyan LI ; Donghua LIU ; Qiuying ZHANG ; Xuefei HU ; Liang GUO ; Sijin MAN ; Dijing SONG ; Rong XU ; Youdong YIN ; Kunpeng LIANG ; Aiyun LI ; Zhuo LI ; Hongxia HU ; Guoping LU ; Jinhua LIANG ; Qiang LIU ; Yinqiao DONG ; Jilu SHEN ; Shuyan HU ; Liang LUAN ; Jian LI ; Ling MENG ; Dengyan QIAO ; Xiusan XIA ; Bo QUAN ; Dahong WANG ; Chunhua HAN ; Xiaoping YAN ; Fei LI ; Shifu WANG ; Ping SHEN ; Yunbo CHEN ; Yonghong XIAO
Chinese Journal of Clinical Infectious Diseases 2025;18(1):47-62
Objective:To report the results of bacterial resistant investigation collaborative system(BRICS)on the distribution and antimicrobial resistance profile of clinical Gram-negative bacteria isolates from bloodstream infections in China in 2023,and provide reference for clinical tretment of bloodstream infections and prevention and control of bacterial resistance.Methods:The clinical isolates of Gram-negative bacteria from blood cultures in member hospitals of BRICS were collected during January 2023 to December 2023. Antibiotic susceptibility tests were conducted by agar dilution or broth dilution methods recommended by Clinical and Laboratory Standards Institute(CLSI). WHONET 5.6 and SPSS 25.0 were used to analyze the data.Results:During the study period,11 492 strains of Gram-negative bacteria were collected from 60 hospitals,of which 10 098(87.9%)were Enterobacterales and 1 394(12.1%)were non-fermentative bacteria. The top 5 bacterial species were Escherichia coli(50.0%), Klebsiella pneumoniae(26.1%), Pseudomonas aeruginosa(5.1%), Acinetobacter baumannii complex(5.0%)and Enterobacter cloacae complex(4.1%). The ESBL-producing rates in Escherichia coli, Klebsiella pneumoniae and Proteus mirablilis were 46.8%(2 685/5 741),18.3%(549/2 999)and 44.0%(77/175),respectively. The prevalence of carbapenem-resistant Escherichia coli(CREC)and carbapenem-resistant Klebsiella pneumoniae(CRKP)were 1.3%(76/5 741)and 15.0%(450/2 999);32.9%(25/76)and 78.0%(351/450)of CREC and CRKP were sensitive to ceftazidime/avibactam combination,respectively. 94.7%(72/76)and 90.2%(406/450)of CREC and CRKP were sensitive to aztreonam/avibactam combination. Furthermore,57.9%(44/76)and 79.1%(356/450)were sensitive to imipenem/relebactam combination. The prevalence of carbapenem-resistant Acinetobacter baumannii(CRAB)complex was 64.6%(370/573),while more than 80.0% of CRAB complex was sensitive to tigecycline,eravacycline and polymyxin B. The prevalence of carbapenem-resistant Pseudomonas aeruginosa(CRPA)was 17.0%(99/581). There were differences in the composition ratio of Gram-negative bacteria in bloodstream infections and the prevalence of important Gram-negative bacteria resistance among different regions in China,with statistically significant differences in the prevalence of CREC,CRKP,CRPA and CRAB complex( χ2=10.6,28.6,10.8 and 19.3, P<0.05). The prevalence of ESBL-producing Escherichia coli, CREC,CRAB complex and CRKP were higher in provincial hospitals than those in municipal hospitals( χ2=12.5,9.8,12.7 and 57.8,all P<0.01). Conclusions:Gram-negative bacteria are the main pathogens causing bloodstream infections in China,and Escherichia coli is ranked in the top,while the trend of Klebsiella pneumoniae increases continuously with time. CRKP infection shows a slow upward trend,CREC infecton maintains a low prevalence level,and CRAB complex infection continues to exhibit a high prevalence rate. The composition and resistance patterns of pathogens causing bloodstream infections vary to some extent across different regions and levels of hospitals in China.
8.Analysis of the correlation between sex hormones and micropenis after mild hypospadias surgery in children
Jiayi WANG ; Haiyang ZHANG ; Lijuan GUO ; Hui LIU ; Hongxia LIU ; Ru JIA ; Yakai LIU ; Dan SU ; Cuiping SONG
Chinese Journal of Applied Clinical Pediatrics 2025;40(8):619-624
Objective:To analyze the correlation between sex hormone levels and micropenis after mild hypospadias surgery in children.Methods:A case control study was carried out.The clinical data of 71 children aged 1 to 13 years who underwent mild hypospadias surgery at the First Affiliated Hospital of Xinxiang Medical University from April 2022 to April 2024 were analyzed.Preoperatively, the children were divided into a mild hypospadias group (Group A) and a mild hypospadias with micropenis group (Group B) based on the stretched penile length (SPL).Prolactin, follicle-stimulating hormone (FSH), luteinizing hormone (LH), progesterone, and testosterone (TES) levels of the 2 groups were measured.Multivariate Logistic regression analysis was used to construct a risk prediction model.The discrimination capability of the model was evaluated using the receiver operating characteristic (ROC) curve.SPL and sex hormone levels were measured again 6 months after surgery.The children were divided into a normal penile group (Group AA) and a micropenis group (Group BB) after mild hypospadias according to SPL.Multivariate Logistic regression analysis was used to construct a risk prediction model, which was evaluated using the ROC curve.Results:The levels of FSH, LH and TES in group A before the operation were 3.28(2.02, 4.46) IU/L, 0.53(0.25, 0.79) IU/L and 25.24(17.94, 36.67) ng/dL, respectively, and those in group B were 1.42(1.10, 1.84) IU/L, 0.14(0.09, 0.23) IU/L and 15.73 (12.92, 17.00) ng/dL, respectively.The difference was all statistically significant (all P<0.05).Multivariate Logistic regression analysis showed statistical significance ( OR=0.515, 95% CI: 0.271-0.977; OR=0.035, 95% CI: 0.002-0.542; OR=0.883, 95% CI: 0.796-0.980).The area under the ROC curve (AUC) of the prediction model was 0.906, with a sensitivity of 75.00% and a specificity of 95.74%.The levels of FSH, LH and TES in the postoperative AA group were 2.97 (1.88, 4.28) IU/L, 0.46 (0.23, 0.78) IU/L and 20.92 (17.34, 33.27) ng/dL, respectively.The median levels of FSH, LH and TES in the BB group were 1.52 (1.27, 1.82) IU/L, 0.17 (0.12, 0.26) IU/L and 15.08(11.68, 16.68) ng/dL, respectively.The difference was all statistically significant (all P<0.05).Multivariate Logistic regression analysis showed statistical significance ( OR=0.484, 95% CI: 0.236-0.992; OR=0.061, 95% CI: 0.004-0.939; OR=0.891, 95% CI: 0.795-0.999).The AUC of the prediction model constructed was 0.877, with a sensitivity of 94.12% and a specificity of 68.52%. Conclusions:Lower FSH, LH and TES levels are risk factors for the micropenis after mild hypospadias surgery, and preoperative hormone levels have higher predictive value.
9.Strengthening the Construction of Clinical Quality Control System for MRI Equipment to Ensure Their Efficacy in Clinical Application
Hongxia YIN ; Chengwei LI ; Yawen LIU ; Hui XU ; Yu ZHANG ; Zhenchang WANG
Chinese Journal of Medical Imaging 2025;33(6):583-586
With the rapid increase in the ownership of MRI equipment in China,quality control,particularly in clinical usage aspects,has become critically important.For clinical quality control of MRI systems,it is essential to establish comprehensive workflow principles encompassing multiple elements such as personnel,equipment,standards,tools and methodologies.To advance the standardization and widespread adoption of clinical quality control for MRI equipment,efforts must focus on strengthening regulatory frameworks,advancing phantom research,development and enhancing professional expertise.Concurrently,continuous improvements in training programs and supervision mechanisms are necessary to ensure the effective implementation of MRI clinical quality control practices.Furthermore,in the era of digital healthcare,clinical quality assurance for MRI equipment is evolving toward automation and intelligent solutions,providing higher-quality and more efficient assurance for clinical applications.
10.Automatic Measurement Method for Spatial Resolution of MRI Based on the ACR Phantom
Yu ZHANG ; Hongxia YIN ; Yawen LIU ; Pengling REN ; Yanjun HU ; Tianxin CHENG ; Zhenghan YANG ; Zhenchang WANG ; Hui XU
Chinese Journal of Medical Imaging 2025;33(6):595-600,606
Purpose To measure the spatial resolution in MRI quality control testing automatically based on the American College of Radiology(ACR)phantom using the support vector machine(SVM)method,and the feasibility,accuracy and measurement speed of this method are explored.Materials and Methods Quality control tests were performed using eight MRI devices at Beijing Friendship Hospital of Capital Medical University.A retrospective study was conducted on 71 MRI quality control test images collected based on ACR phantoms between 2017 and 2019.The images were preprocessed by binarization,extraction region of interest and so on.An SVM-based classification model was constructed for analyzing the spatial resolution of dot arrays in row and column directions.The dataset was randomly split into a training set and a test set.The generalization performance of the classification model in this study was evaluated through accuracy,precision,recall and F1 score on the test set.Comparing the results of spatial resolution measurements obtained by both manual and automatic method,we demonstrated the feasibility and accuracy of the method.Additionally,the time taken for the automatic spatial resolution measurement was recorded.Results In this study,the proposed method of automatically measuring the spatial resolution of ACR phantom test images using SVM was feasible,high accuracy and short time.In classification performance test,the accuracy of the spatial resolution of the row directional latices was 95%,the precision was 100%.The accuracy of the spatial resolution of the column directional latices was 97%,the precision was 100%.Among the test cases,the results of automatic measurements matched those of manual measurements in 13 out of 14 cases.On average,automatic spatial resolution measurement took 0.158 seconds per case.Conclusion This study achieves automatic measurement of spatial resolution in MRI quality control based on the ACR phantom using SVM method.The method demonstrates high accuracy and fast measurement speeds,holding significant implications for future rapid MRI quality control stability testing.

Result Analysis
Print
Save
E-mail