1.Short- to medium-term safety and efficacy of the implantable Corheart 6 left ventricular assist system in patients with end-stage heart failure
Zhibing QIU ; Xiaochun SONG ; Liangpeng LI ; Hongwei SHI ; Liqiong XIAO ; Yunzhang WU ; Xiaosong RONG ; Jidan FAN ; Liang WEI ; Xin CHEN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(05):639-645
Objective To investigate the efficacy and safety of the Corheart 6 left ventricular assist system in patients with end-stage heart failure. Methods A retrospective study was conducted on patients with end-stage heart failure who were treated with Corheart 6 left ventricular assist system from March 2022 to June 2024 in 4 hospitals in Jiangsu Province. The efficacy of the device was evaluated by comparing changes in clinical indicators at preoperative, discharge, 3-month postoperative, and 6-month postoperative timepoints, including the New York Heart Association (NYHA) functional classification, left ventricular ejection fraction (LVEF), and left ventricular end-diastolic diameter (LVEDD). The safety of the device was assessed by analyzing the intraoperative position and orientation of the blood pump inlet cannula, as well as the incidence of adverse events. Results In this study, 39 patients were collected, including 34 males and 5 females with a mean age of (56.4±12.5) years, ranging from 20 to 75 years. There was no operative death. There was no death in postoperative 3 months with a survival rate of 100.0%. There were 3 deaths in 6 months postoperatively, with a survival rate of 92.3%. All patients had a preoperative NYHA cardiac function classification of class Ⅳ. The NYHA cardiac function class of the patients improved (P<0.05) at discharge, 3 and 6 months after surgery when compared to the preoperative period. LVEF was significantly higher at 3 months after surgery than that during the preoperative period (P<0.05). LVEDD was significantly smaller at discharge, 3 and 6 months after surgery than that during the preoperative period (P<0.05). The safety evaluation's findings demonstrated that all 39 patients' intraoperative blood pump inlet tubes were oriented correctly, the artificial blood vessel suture sites were appropriate, there were no instances of device malfunction or pump thrombosis, or instances of bleeding or hemolysis, and the rate of the remaining adverse events was low. Conclusion With a low rate of adverse events and an excellent safety profile, the Corheart 6 left ventricular assist system can efficiently enhance cardiac function in patients with end-stage heart failure. It also has considerable clinical uses.
2.Guidelines for the diagnosis and treatment of prurigo nodularis.
Li ZHANG ; Qingchun DIAO ; Xia DOU ; Hong FANG ; Songmei GENG ; Hao GUO ; Yaolong CHEN ; Chao JI ; Chengxin LI ; Linfeng LI ; Jie LI ; Jingyi LI ; Wei LI ; Zhiming LI ; Yunsheng LIANG ; Jianjun QIAO ; Zhiqiang SONG ; Qing SUN ; Juan TAO ; Fang WANG ; Zhiqiang XIE ; Jinhua XU ; Suling XU ; Hongwei YAN ; Xu YAO ; Jianzhong ZHANG ; Litao ZHANG ; Gang ZHU ; Fei HAO ; Xinghua GAO
Chinese Medical Journal 2025;138(22):2859-2861
3.Expert consensus on the prevention and treatment of radiochemotherapy-induced oral mucositis.
Juan XIA ; Xiaoan TAO ; Qinchao HU ; Wei LUO ; Xiuzhen TONG ; Gang ZHOU ; Hongmei ZHOU ; Hong HUA ; Guoyao TANG ; Tong WU ; Qianming CHEN ; Yuan FAN ; Xiaobing GUAN ; Hongwei LIU ; Chaosu HU ; Yongmei ZHOU ; Xuemin SHEN ; Lan WU ; Xin ZENG ; Qing LIU ; Renchuan TAO ; Yuan HE ; Yang CAI ; Wenmei WANG ; Ying ZHANG ; Yingfang WU ; Minhai NIE ; Xin JIN ; Xiufeng WEI ; Yongzhan NIE ; Changqing YUAN ; Bin CHENG
International Journal of Oral Science 2025;17(1):54-54
Radiochemotherapy-induced oral mucositis (OM) is a common oral complication in patients with tumors following head and neck radiotherapy or chemotherapy. Erosion and ulcers are the main features of OM that seriously affect the quality of life of patients and even the progress of tumor treatment. To date, differences in clinical prevention and treatment plans for OM have been noted among doctors of various specialties, which has increased the uncertainty of treatment effects. On the basis of current research evidence, this expert consensus outlines risk factors, clinical manifestations, clinical grading, ancillary examinations, diagnostic basis, prevention and treatment strategies and efficacy indicators for OM. In addition to strategies such as basic oral care, anti-inflammatory and analgesic agents, anti-infective agents, pro-healing agents, and photobiotherapy recommended in previous guidelines, we also emphasize the role of traditional Chinese medicine in OM prevention and treatment. This expert consensus aims to provide references and guidance for dental physicians and oncologists in formulating strategies for OM prevention, diagnosis, and treatment, standardizing clinical practice, reducing OM occurrence, promoting healing, and improving the quality of life of patients.
Humans
;
Chemoradiotherapy/adverse effects*
;
Consensus
;
Risk Factors
;
Stomatitis/etiology*
4.Exploring the mechanism of Xiaoaiping Injection inhibiting autophagy in prostate cancer based on proteomics.
Qiuping ZHANG ; Qiuju HUANG ; Zhiping CHENG ; Wei XUE ; Shoushi LIU ; Yunnuo LIAO ; Xiaolan LI ; Xin CHEN ; Yaoyao HAN ; Dan ZHU ; Zhiheng SU ; Xin YANG ; Zhuo LUO ; Hongwei GUO
Chinese Journal of Natural Medicines (English Ed.) 2025;23(1):64-76
Xiaoaiping (XAP) Injection demonstrates the anti-prostate cancer (PCa) effects, yet the underlying mechanism remains unclear. This study aims to investigate the impact of XAP on PCa and elucidate its mechanism of action. PCa cell proliferation was evaluated using a cell counting kit-8 (CCK-8) assay. Cell apoptosis was assessed through Hoechst staining and Western blotting assays. Proteomics technology was employed to identify key molecules and significant signaling pathways modulated by XAP in PCa cells. To further validate potential key genes and important pathways, a series of assays were conducted, including acridine orange (AO) staining, transmission electron microscopy, and immunofluorescence assays. The molecular mechanism of XAP against PCa in vivo was examined using a PC3 xenograft mouse model. Results demonstrated that XAP significantly inhibited cell proliferation in multiple PCa cell lines. In C4-2 and prostate cancer cell line-3 (PC3) cells, XAP induced cellular apoptosis, evidenced by reduced B-cell lymphoma 2 (Bcl-2) levels and elevated Bcl-2-associated X (Bax) levels. Proteomic, immunofluorescence, and quantitative reverse transcription-polymerase chain reaction (qRT-PCR) investigations revealed a strong correlation between forkhead box O3a (FoxO3a) autophagic degradation and the anti-PCa action of XAP. XAP hindered autophagy by reducing the expression levels of autophagy-related protein 5 (Atg5)/autophagy-related protein 12 (Atg12) and enhancing FoxO3a expression and nuclear translocation. Furthermore, XAP exhibited potent anti-PCa action in PC3 xenograft mice and triggered FoxO3a nuclear translocation in tumor tissue. These findings suggest that XAP induces PCa apoptosis via inhibition of FoxO3a autophagic degradation, potentially offering a novel perspective on XAP injection as an effective anticancer therapy for PCa.
Male
;
Humans
;
Prostatic Neoplasms/physiopathology*
;
Autophagy/drug effects*
;
Animals
;
Drugs, Chinese Herbal/pharmacology*
;
Proteomics
;
Mice
;
Apoptosis/drug effects*
;
Cell Line, Tumor
;
Cell Proliferation/drug effects*
;
Forkhead Box Protein O3/genetics*
;
Xenograft Model Antitumor Assays
;
Mice, Nude
;
Mice, Inbred BALB C
5.Bioactivity-guided discovery of antiviral templichalasins A‒C from the endophytic fungus Aspergillus templicola.
Teng CAI ; Jingzu SUN ; Wenxuan CHEN ; Qiang HE ; Baosong CHEN ; Yulong HE ; Peng ZHANG ; Yanhong WEI ; Hongwei LIU ; Xiaofeng CAI
Chinese Journal of Natural Medicines (English Ed.) 2025;23(6):754-761
The bioactivity-guided isolation of potentially active natural products has been widely utilized in pharmaceutical discovery. In this study, by screening fungal extracts against coxsackievirus B3 (CVB3), three new aspochalasins, templichalasins A‒C (1‒3), along with six known aspochalasins (4‒9) were isolated from an active extract derived from the endophytic fungus Aspergillus templicola LHWf045. Compound 1 features a unique 5/6/5/7/5 pentacyclic ring system, while compounds 2 and 3 possess unusual 5/6/6/7 tetracyclic skeletons. Their structures were characterized through extensive spectroscopic analyses, electronic circular dichroism (ECD) calculations, and single-crystal X-ray diffraction analysis. Additionally, we demonstrated that compound 4 can be readily converted into compounds 1‒3 under mild acidic conditions and proposed a plausible mechanism for this conversion. Bioactivity evaluation of compounds 1‒9 against CVB3 revealed the inhibitory effects of all compounds against the virus. Notably, compound 9 exhibited superior antiviral activity, surpassing the commercial drug ribavirin in selectivity index (SI) value.
Antiviral Agents/isolation & purification*
;
Aspergillus/chemistry*
;
Molecular Structure
;
Enterovirus B, Human/drug effects*
;
Endophytes/chemistry*
;
Cytochalasins/isolation & purification*
;
Drug Discovery
;
Humans
6.Investigation on the basic situation of pre-analytical quality management in blood station laboratories in North China
Jing SUN ; Hongwei GE ; Zhengmin LIU ; Qianqian QIN ; Wei HAN ; Tong PAN ; Dongli JIAO ; Xiaolan DONG ; Rui WANG
Chinese Journal of Blood Transfusion 2025;38(11):1514-1520
Objective: To investigate the basic situation of pre-analytical quality management in blood station laboratories in North China, and to provide baseline data for promoting the homogenization and standardization of these pre-analytical processes in each blood station laboratory. Methods: A cross-sectional status survey was designed based on the quality management regulations of blood stations, ISO15189 standards and relevant quality management requirements. This survey covering various aspects including laboratory general situation, sample collection and temporary storage, transportation, reception, and quality continuous improvement situations. Data analysis was performed on the survey results of each laboratory. Results: All the 38 blood station laboratories in North China had established a pre-analytical quality management system framework and implemented basic pre-analytical quality control activities; however, there were differences in implementation. 1) Among the 12 basic quality items, 3 items were monitored by all the investigated laboratories (100%), 6 items were monitored by the vast majority of laboratories (about 90%), and 3 items were monitored by a portion of laboratories (about 60%). There were no significant differences in the monitoring index among the three regions and among different types of laboratories (P>0.05). 2) Among the total of 26 items in the three key processes before testing (sample collection and storage, transportation, reception and processing), 12 items were monitored by all laboratories (100%), 11 items were monitored by the vast majority of laboratories (about 90%), and 3 items were monitored by a portion of laboratories (about 75%). There were no significant differences in monitoring index among different regions and types of laboratories (P>0.05). Conclusion: This survey provides a reference and basis for the gap analysis of the pre-analytical process quality management in 38 blood station laboratories across North China. It facilitates laboratories in identifying pre-analytical quality problems, resolving problems, preventing errors, and ensuring that the quality of blood samples before testing meets the established requirements. It lays a foundation for the homogenization of pre-analytical quality management in regional blood stations.
7.Analysis of unqualified pre-analytical samples in blood station laboratories in North China
Zhengmin LIU ; Hongwei GE ; Qianqian QIN ; Wei HAN ; Tong PAN ; Dongli JIAO ; Xiaolan DONG ; Rui WANG
Chinese Journal of Blood Transfusion 2025;38(11):1521-1528
Objective: To determine the frequency and main reasons of unqualified samples by analyzing the quality of pre-analytical samples in blood stations in North China, thereby providing a reference and basis for gap analysis in the implementation of pre-analytical process quality management for participating laboratories and ensuring that only high-standard and high-quality blood samples proceed to testing. Methods: Data on the quality of pre-analytical samples from blood station laboratories in North China was collected via questionnaire. Statistical analysis were performed on: 1) the basic information of samples quality monitoring in the laboratories; 2) the distribution of the overall pre-analytical unqualified rate of samples and the pre-analytical unqualified rate of samples in each laboratory; 3) the distribution of reasons for sample disqualification. Results: 1) The overall pre-analytical unqualified rate of samples in blood station laboratories in North China was 4.55, with a total sigma level of 5.39σ. The 25th, 50th and 75th percentiles (P25, P50, P75) for the total unqualified rate were 0.00, 1.10 and 5.96, respectively. The corresponding percentiles for the Sigma level were 5.34σ, 5.71σ, and 6.00σ, respectively. The pre-analytical unqualified rate of serological and nucleic acid samples (4.89 vs 4.22) showed a significant difference (χ
=9.575, P<0.05). 2) The average unqualified rate of samples in region A, B and C was 1.71, 9.50 and 12.64 (χ
=1 590.721, P<0.05), and the sigma level was 5.66σ, 5.21σ and 5.16σ, respectively. 3) The main reasons for unqualified serological samples were chylous blood (72.65%), hemolysis (17.39%), abnormal hematocrit (5.80%), and insufficient volume (3.50%). The main reasons for the unqualified nucleic acid samples were chylous blood (78.26%), hemolysis (8.84%), failure to centrifuge as required (5.01%), abnormal hematocrit (4.66%), and insufficient volume (1.92%). Conclusion: In North China, the quality indicators for the pre-analytical processes in blood station laboratories are generally well-managed. Laboratories in region A outperformed the national average in pre-analytical specimen quality control. However, participating laboratories exhibit gaps in implementing pre-analytical quality management. Through effective analysis of pre-analytical process quality metrics and inter-laboratory comparisons, laboratories can identify discrepancies and address shortcomings. By establishing clear quality objectives, they can achieve continuous improvement and ensure the validity of test results.
8.Investigation on the management of hemolytic and lipemic samples in the preanalytical phase in blood station laboratories in North China
Jing SUN ; Hongwei GE ; Zhengmin LIU ; Qianqian QIN ; Wei HAN ; Tong PAN ; Dongli JIAO ; Xiaolan DONG ; Rui WANG
Chinese Journal of Blood Transfusion 2025;38(11):1529-1534
Objective: To investigate the assessment criteria and subsequent handling practices of hemolytic and lipemic blood samples before testing in blood screening laboratories in North China, and to provide data to support the standardization of their management in blood station laboratories. Methods: Data on the preanalytical management of hemolytic and lipemic samples from 38 laboratories were collected. The details of management on the criteria and verificatioon for assessment, the assessment methods, and subsequent handling procedures of hemolytic and lipemic samples in blood station laboratories were analyzed. Results: 1) All 38 blood station laboratories monitored serological and nucleic acid samples for hemolysis and lipemia in pre-analytical phase. 2) The criteria and methods for assessing hemolytic and lipemic samples varied among the laboratories of the 38 blood stations. 15 laboratories (39.47%) followed manufacturer's instructions, 9 laboratories (23.68%) formulated their own criteria, and 14 laboratories (36.84%) referred to the criteria of other laboratories. 16 laboratories (42.11%) verified the criteria for assessing hemolytic and lipemic samples, with significant variations in verification rate across laboratories from different regions (P<0.05). For the assessment methods, visual inspection was used by 28 laboratories (73.68%) for hemolytic samples and by 27 laboratories (71.05%) for lipemic samples; the colorimetric card method was used by 10 laboratories (26.32%) for assessing both hemolytic and lipemic samples; the instrumental method was used by 1 laboratory (2.63%) for assessing lipemic samples.3) The handling procedures for hemolytic and lipemic samples varied significantly and followed a gradient distribution pattern among 38 laboratories (including accepting samples for testing, accepting samples for concession testing, re-collecting samples, and rejecting samples and halting testing). With increasing severity of hemolysis and lipemia, more laboratories halted testing, and relatively fewer laboratories accepted samples for normal testing. 5 laboratories (13.16%) applied different handling procedures on serological and nucleic acid samples. Conclusion: This survey provides a reference and basis for analyzing gaps in the management of hemolytic and lipemic samples during the preanalyical phase in blood station laboratories in North China. It enables laboratories to identify the problems and deficiencies in the management of hemolytic and lipemic samples, to ensure preanalytical samples quality meets the established requirements, and to lay a foundation for promoting the homogenization and standardization of the regional sample quality management mode.
9.Values of different DIC scoring systems in early diagnosis and prognosis prediction of coagulation dysfunc-tion in sepsis patients
Fangmin GENG ; Yuandan HE ; Wenjuan LI ; Qianqian LIU ; Hongwei ZHANG ; Zhangping LU ; Lianhua WEI
The Journal of Practical Medicine 2024;40(2):248-252
Objective To evaluate five types of DIC scoring systems based on sepsis patients,to explore the values of different DIC scoring systems in the occurrence and prognosis of DIC in sepsis patients,and to compare the applicability of different DIC scoring systems for sepsis complicated with DIC.Methods Laboratory indexes and clinical data from sepsis patients who had been hospitalized in Gansu Provincial People's Hospital from December 1,2019 to December 31,2021 were retrospectively analyzed within 24 hours.Five types of DIC scoring systems were used to score,and the difference of diagnostic rate and discharge outcome in sepsis patients with different severity was compared.The ROC curves of five DIC scoring systems were established to evaluate the accu-racy of DIC in sepsis patients.Results The fatality rate of sepsis increased with the severity of sepsis(P<0.05).There were statistically significant differences in discharge outcomes between DIC and non-DIC in the five scoring systems(P<0.05).JMHW,CDSS and part of ISTH were detected in JAAM cases,while ISTH was detected in non-dominant ISTH cases.ISTH,JAAM,JMHW,CDSS,and non-dominant ISTH5 scoring systems were used to diagnose DIC,and absence of full health restoration and death were 3.0,3.8,4.2,3.9,and 3.0 times higher than non-DIC cases,respectively.Conclusion JAAM scoring system has higher diagnostic rate and sensitivity for adult sepsis.CDSS and JMHW scoring systems are more accurate in predicting the prognosis of sepsis patients.
10.A review of structural modification and biological activities of oleanolic acid.
Huali YANG ; Minghui DENG ; Hongwei JIA ; Kaicheng ZHANG ; Yang LIU ; Maosheng CHENG ; Wei XIAO
Chinese Journal of Natural Medicines (English Ed.) 2024;22(1):15-30
Oleanolic acid (OA), a pentacyclic triterpenoid, exhibits a broad spectrum of biological activities, including antitumor, antiviral, antibacterial, anti-inflammatory, hepatoprotective, hypoglycemic, and hypolipidemic effects. Since its initial isolation and identification, numerous studies have reported on the structural modifications and pharmacological activities of OA and its derivatives. Despite this, there has been a dearth of comprehensive reviews in the past two decades, leading to challenges in subsequent research on OA. Based on the main biological activities of OA, this paper comprehensively summarized the modification strategies and structure-activity relationships (SARs) of OA and its derivatives to provide valuable reference for future investigations into OA.
Oleanolic Acid
;
Structure-Activity Relationship
;
Anti-Inflammatory Agents/pharmacology*
;
Triterpenes
;
Anti-Bacterial Agents/pharmacology*

Result Analysis
Print
Save
E-mail