1.The effect of body mass index and inferior pulmonary ligament division on the residual lung expansion after right upper lobectomy: A retrospective cohort study in a single center
Guang MU ; Wenhao ZHANG ; Hongchang WANG ; Yan GU ; Chenghao FU ; Wentao XUE ; Shiyuan XIE ; Tong WANG ; Ke WEI ; Yang XIA ; Liang CHEN ; Jun WANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(02):261-266
Objective To analyze the effect of releasing the lower pulmonary ligament on right residual lung expansion after right upper lobe resection under different body mass index (BMI) levels. Methods The clinical data of patients who underwent thoracoscopic right upper lobe resection in the First Affiliated Hospital with Nanjing Medical University from 2021 to 2022 were retrospectively analyzed. Patients were divided into a group A (17 kg/m2<BMI≤23 kg/m2), a group B (23 kg/m2<BMI≤29 kg/m2) and a group C (BMI>29 kg/m2) according to BMI. The presence of residual cavity was judged by chest X-ray at 7-10 days after operation, the degree of compensation change of the right main bronchus angle was measured, and the changes in lung volume were determined by CT three-dimensional reconstruction. Results A total of 157 patients who underwent thoracoscopic right upper lobe resection were included, including 71 males and 86 females, with an average age of (59.7±11.2) years. There were 50 patients in the group A, 75 patients in the group B, and 32 patients in the group C. In the group A, compared with those without releasing the lower pulmonary ligament, patients with releasing had a lower incidence of postoperative residual cavity (P=0.016), greater changes in bronchus angle (P<0.001), and smaller changes in lung volume (P<0.001). In the group B and C, there was no significant effect of releasing the lower pulmonary ligament on postoperative residual cavity, bronchus angle, and lung volume changes (P>0.05). Conclusion For patients with thin and long body shape and low BMI, releasing the lower pulmonary ligament is helpful to promote the expansion of the residual lung after right upper lobe resection and reduce the occurrence of postoperative residual cavity in patients.
2.Expert consensus on peri-implant keratinized mucosa augmentation at second-stage surgery.
Shiwen ZHANG ; Rui SHENG ; Zhen FAN ; Fang WANG ; Ping DI ; Junyu SHI ; Duohong ZOU ; Dehua LI ; Yufeng ZHANG ; Zhuofan CHEN ; Guoli YANG ; Wei GENG ; Lin WANG ; Jian ZHANG ; Yuanding HUANG ; Baohong ZHAO ; Chunbo TANG ; Dong WU ; Shulan XU ; Cheng YANG ; Yongbin MOU ; Jiacai HE ; Xingmei YANG ; Zhen TAN ; Xiaoxiao CAI ; Jiang CHEN ; Hongchang LAI ; Zuolin WANG ; Quan YUAN
International Journal of Oral Science 2025;17(1):51-51
Peri-implant keratinized mucosa (PIKM) augmentation refers to surgical procedures aimed at increasing the width of PIKM. Consensus reports emphasize the necessity of maintaining a minimum width of PIKM to ensure long-term peri-implant health. Currently, several surgical techniques have been validated for their effectiveness in increasing PIKM. However, the selection and application of PIKM augmentation methods may present challenges for dental practitioners due to heterogeneity in surgical techniques, variations in clinical scenarios, and anatomical differences. Therefore, clear guidelines and considerations for PIKM augmentation are needed. This expert consensus focuses on the commonly employed surgical techniques for PIKM augmentation and the factors influencing their selection at second-stage surgery. It aims to establish a standardized framework for assessing, planning, and executing PIKM augmentation procedures, with the goal of offering evidence-based guidance to enhance the predictability and success of PIKM augmentation.
Humans
;
Consensus
;
Dental Implants
;
Mouth Mucosa/surgery*
;
Keratins
3.Boosting prediction of occupational stress among manufacturing employees by reconstructing cumulative fatigue features with Bayesian sparse autoencoder
Tao SONG ; Yuting ZHOU ; Xinyi LU ; Xinkai WEI ; Qingxin MENG ; Jianlin LOU ; Hongchang ZHOU ; Jin WANG ; Shuang LI
Journal of Environmental and Occupational Medicine 2025;42(12):1446-1455
Background Occupational stress has emerged as a critical public health concern affecting the physical and mental well-being of workers in the manufacturing sector. However, researchers typically evaluate its core driver—cumulative fatigue—using a crude binary “present/absent” variable, thereby overlooking the high-dimensional complexity and heterogeneity inherent in fatigue characteristics. This oversimplification constrains both the precision and predictive performance of occupational stress risk assessment model. Objective Leveraging a data-driven approach, to survey data on cumulative fatigue among manufacturing employees, and then use this new classification to develop and validate an occupational stress prediction model, with an ultimate aim of enhancing the accuracy and effectiveness of occupational stress assessment. Methods A set of cross-sectional survey data on
4.Comparative analysis on pulse diagnosis in traditional medicine in China and Myanmar
Wei LUO ; Hongchang LI ; Ningyi WEI
International Journal of Traditional Chinese Medicine 2025;47(9):1215-1219
A comparative analysis of TCM pulse diagnosis and Myanmar medicine pulse diagnosis. In the principle of pulse diagnosis, both of them recognize the heart as the power source of pulse, and attach importance to the running state of qi and blood/elements, but Myanmar medicine pays more attention to the dynamic balance of elements, and TCM focuses on the dialectical relationship between qi and blood. In terms of the diagnosis site, the diagnosis method of the lower limbs of Myanmar medicine, the diagnosis method of the pulsation of the medial foot and the lower ankle of the foot, respectively, is similar to the diagnosis method of the lower limbs of TCM, and the diagnosis method of the Taixi pulse in the diagnosis site and significance. It can evaluate the digestive ability of patients and judge whether the stomach is full or not. The blood test method of Myanmar medicine wrist is similar to the Cunkou diagnosis method of TCM in terms of location and method, but the significance is different. In the understanding of normal pulses, there are some similarities in the description of pulse position and pulse force of normal pulse, and both emphasize the change of pulse with season. In terms of disease pulse identification, 11 of the 20 common pathological blood (pulse condition) of Myanmar medicine are similar to the disease pulse of TCM in terms of morphology and main disease, but there are also obvious differences. In general, there is convergence in the theoretical basis of pulse diagnosis between China and Myanmar, and the pulse diagnosis system of Myanmar medicine can provide new ideas for TCM. It is suggested that the two countries should strengthen mutual learning, carry out cross-cultural objective joint research on pulse diagnosis, and promote the construction of relevant databases.
5.Effect of drinking hydrogen-rich water on preventing heat stroke of workers in special positions
Hongchang LI ; Wei JIANG ; Chuanfang LIU ; Fengxin YU
Journal of Navy Medicine 2025;46(7):683-687
Objective To observe the effect of drinking hydrogen-rich water on preventing heat stroke(HS)of workers in special positions.Methods A total of 384 workers in special positions were selected with cluster sampling in February 2022.They were assigned to control group or observation group by a random number table,with 192 cases in each group.Double-blind experiment method was adopted.On the basis of the prevention and health education of HS,routine protection and daily drinking water in the study subjects,the observation group drank 1.5 L of hydrogen-rich water every day(200-300 ml each time,5-7 times a day,the hydrogen concentration of hydrogen-rich water was 1 800 μg/L),and the control group drank 1.5 L of pure water every day(200-300 ml each time,5-7 times a day)for 6 months.On the day after the intervention,all the workers underwent 10 km weight-bearing cross-country training.During the intervention period,the incidences of HS and its precursor,the detection rate of heat tolerance difference before and after the intervention,core temperature,serum markers of heat intolerance,and inflammatory factors were observed.Results During the intervention period,the precursor of HS appeared in 2 patients(1.04%)in the observation group and 11 patients(5.73%)in the control group,and 1 patient(0.52%)was diagnosed with HS in the control group.The incidences of HS and its precursor in the observation group were lower than those in the control group(P<0.01).After the weight-bearing training,the core body temperature was increased in both groups(P<0.01),but the core body temperature in the observation group was lower than that in the control group(P<0.01).The detection rate of heat tolerance difference,serum heat intolerance markers(alanine aminotransferase,creatine kinase,and creatinine)and inflammatory factors(interleukin-1,interleukin-6,and tumor necrosis factor-α)in the observation group were lower than those in control group after intervention(P<0.05),and those before intervention(P<0.05).Conclusion Drinking hydrogen-rich water can improve the thermal tolerance of workers in special positions,and inhibit or reduce the inflammatory response caused by high heat.It can be used to prevent HS in special positions.
6.Application of laparoscopic contrast enhanced ultrasound in laparoscopic surgery for hepatocellular carcinoma combined with cirrhosis
Shu ZHU ; Hongchang LUO ; Jingyuan CHEN ; Shujun YANG ; Suxian WEI ; Dan WANG
Chinese Journal of Postgraduates of Medicine 2024;47(1):68-73
Objective:To explore the application value of laparoscopic contrast enhanced ultrasound in laparoscopic surgery for patients with hepatocellular carcinoma combined with cirrhosis.Methods:The clinical data of 71 patients with hepatocellular carcinoma combined cirrhosis from February 2018 to February 2020 in Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology were retrospectively analyzed. The patients underwent preoperative enhanced CT and multi-parameter MRI examination, followed by laparoscopic partial hepatectomy, and intraoperative laparoscopic contrast enhanced ultrasound examination. Based on histological examination and follow-up results, the diagnostic efficacy of preoperative imaging and preoperative imaging combined with intraoperative laparoscopic contrast enhanced ultrasound in patients with hepatocellular carcinoma combined with cirrhosis was compared.Results:Among the 71 patients, 69 completed laparoscopic surgery and 2 converted to open surgery. One hundred and ten HCC lesions were diagnosed by preoperative imaging examination, 105 lesions were detected by intraoperative ultrasound among them, of which 98 lesions were diagnosed as HCC by intraoperative laparoscopic contrast enhanced ultrasound. There were no statistically significant difference in sensitivity, specificity, accuracy, positive predictive value and negative predictive value between preoperative imaging and preoperative imaging combined with intraoperative laparoscopic contrast enhanced ultrasound in the diagnosis of malignant liver lesions: 94.4% (102/108) vs. 99.1% (107/108), 81.0% (34/42) vs. 66.7% (28/42), 90.6% (136/150) vs. 90.0% (135/150), 92.7% (102/110) vs. 88.4% (107/121) and 85.0% (34/40) vs. 96.6% (28/29), P>0.05. Laparoscopic contrast enhanced ultrasound revealed an additional 11 suspected malignant lesions, of which 5 lesions were histologically confirmed as HCC. Seven patients underwent surgical strategy changes. Conclusions:Laparoscopic contrast enhanced ultrasound in patients with HCC combined with cirrhosis during laparoscopic surgery can be used to detect, identify, accurately locate of the lesions and modify the surgical plan.
7.Analysis of accuracy and time for the two-in-one navigation registration technique in dynamic navigation implantation:an in vitro study
Min XU ; Shimin WEI ; Junyu SHI ; Hongchang LAI
Journal of Shanghai Jiaotong University(Medical Science) 2024;44(11):1433-1438
Objective·To assess the accuracy and time of the two-in-one registration technique by comparing it with the U-shaped tube registration in dynamic navigation implantation.Methods·Thirty standardized 3D-printed models with mandibular posterior sites missing a single tooth were randomly divided into three groups:two-in-one registration group,U-shaped tube registration group and free-hand implantation group,and the implant surgical plan was designed by the"YIZHIMEI"DCARER oral implant surgery navigation system.Cone beam CT before and after operation was taken.The implant platform deviation,implant apex deviation and angular deviation of the actual implant positions and the designed implant positions were measured.The operating time for using two-in-one registration technique and the U-shaped tube registration technique was recorded to evaluate the complexity of the two registration techniques.The one-way ANOVA and SNK(Student-Newman-Keuls)test were used to analyze the implant platform deviation,implant apex deviation and angular deviation of each group.Results·There were no statistically significant differences in implant platform deviation,implant apex deviation and angular deviation between the two-in-one registration group and the U-shaped tube registration group(P>0.05).However,the implant platform deviation,implant apex deviation and angular deviation of the two-in-one registration group and the U-shaped tube group were lower than those in the free-hand implantation group,and the differences were statistically significant(P<0.001).The operating time required for the two-in-one registration was shorter than that for the U-shaped tube registration process,and the difference was statistically significant(P<0.001).Conclusion·The accuracy of the two-in-one dynamic navigation registration technique used in implanting on a model of mandibular posterior sites missing a single tooth is similar to that of the U-shaped tube dynamic navigation registration technique.But the two-in-one registration takes less time for registration procedure than the U-shaped tube registration,and is easier to operate.
8.Phantom study based on MRI cine sequences: analysis of the accuracy of tumor motion range accuracy
Bing LI ; Yuan WANG ; Ronghu MAO ; Dong LIU ; Wenzheng SUN ; Xiangyue LIU ; Nan MENG ; Wei GUO ; Shuangliang CAO ; Xipan LI ; Chen CHENG ; Hui WU ; Hongyan TAO ; Dingjie LI ; Zhaoyang LOU ; Hongchang LEI ; Lingguang MENG ; Hong GE
Chinese Journal of Radiation Oncology 2024;33(12):1144-1151
Objective:To investigate the accuracy of magnetic resonance imaging (MRI) cine sequences in determining the range of tumor motion in radiotherapy, providing a basis for the precise delineation of the target volume in motion for radiation therapy.Methods:A modified chest motion phantom was placed in a MRI scanner, and a water-filled sphere was used to simulate a tumor. True fast imaging with steady precession (TrueFISP) MRI cine sequences from Siemens were used to capture the two-dimensional motion images of the simulated tumor. The phantom experiments were divided into three modes: head-foot motion mode, rotation motion mode, and actual respiratory waveform mode. In the head-foot motion mode, respiratory motion period (3, 4, 5, 6, 7 and 8 s), amplitude (5, 10 and 15 mm), and respiratory waveform of the simulated tumor (sin and cos4) were set, resulting in a total of 36 motion combinations. In the rotation motion mode, a cos4 waveform was used for respiration, with respiratory periods of 3, 4, 5, 6, 7 and 8 s, head-foot motion set amplitudes of 5, 10 and 15 mm, and anterior-posterior (AP) and left-right (LR) motion set amplitudes in three combinations ([2.5, 2.5] mm, [2.5, 5.0] mm, [5.0, 5.0] mm), resulting in a total of 54 motion combinations. In the actual respiratory waveform mode, respiratory waveforms of 5 randomly selected patients from Affiliated Cancer Hospital of Zhengzhou University were obtained. Under each motion combination, TrueFISP cine images (30 frames, with an acquisition time of 11 s per frame) were obtained. The code was used to automatically identify the two-dimensional coordinates of the center of the simulated tumor in each image, and sin and cos4 functions were separately employed to fit the tumor position in the motion direction, thereby obtaining the fitted motion period and amplitude. The difference between the maximum and minimum values of the tumor's center coordinates in the head-to-foot direction is taken as the range of movement, referred to as the calculated amplitude. For the actual respiratory waveform, the distance between the measured maximum and minimum positions is used to calculate the amplitude.Results:In the head-foot motion mode, the fitted amplitudes of both sin and cos4 waveforms deviated from the set amplitudes by 0-0.51 mm, with relative deviations of 0%-4.2%. The deviation range between the calculated amplitudes and the set amplitudes of the two waveforms were 0.08-0.94 mm, with relative deviations of 1.1%-6.3%. In the rotation motion mode, the fitted amplitudes deviated from the set amplitudes by 0-0.61 mm, with relative deviations of 0%-6.2%. And the deviation range between the calculated amplitudes and the set amplitudes were 0.16-0.94 mm, with relative deviations of 0%-6.3%. In the actual respiratory waveform motion mode, the deviation range between the calculated amplitudes and the set amplitudes were 0.10-0.48 mm, with relative deviations of 2.2%-8.6%.Conclusion:TrueFISP cine sequences show minimal deviations in determining the range of tumor head-foot motion and effectively captures the tumor's movement state, thereby providing important support for the precise definition of the tumor movement target area during radiotherapy .
9.Immunometabolic rewiring in macrophages for periodontitis treatment via nanoquercetin-mediated leverage of glycolysis and OXPHOS.
Yi ZHANG ; Junyu SHI ; Jie ZHU ; Xinxin DING ; Jianxu WEI ; Xue JIANG ; Yijie YANG ; Xiaomeng ZHANG ; Yongzhuo HUANG ; Hongchang LAI
Acta Pharmaceutica Sinica B 2024;14(11):5026-5036
Periodontitis is a chronic inflammatory disease marked by a dysregulated immune microenvironment, posing formidable challenges for effective treatment. The disease is characterized by an altered glucose metabolism in macrophages, specifically an increase in aerobic glycolysis, which is linked to heightened inflammatory responses. This suggests that targeting macrophage metabolism could offer a new therapeutic avenue. In this study, we developed an immunometabolic intervention using quercetin (Q) encapsulated in bioadhesive mesoporous polydopamine (Q@MPDA) to treat periodontitis. Our results demonstrated that Q@MPDA could reprogram inflammatory macrophages to an anti-inflammatory phenotype (i.e., from-M1-to-M2 repolarization). In a murine periodontitis model, locally administered Q@MPDA reduced the presence of inflammatory macrophages, and decreased the levels of inflammatory cytokines (IL-1β and TNF-α) and reactive oxygen species (ROS) in the periodontium. Consequently, it alleviated periodontitis symptoms, reduced alveolar bone loss, and promoted tissue repair. Furthermore, our study revealed that Q@MPDA could inhibit the glycolysis of inflammatory macrophages while enhancing oxidative phosphorylation (OXPHOS), facilitating the shift from M1 to M2 macrophage subtype. Our findings suggest that Q@MPDA is a promising treatment for periodontitis via immunometabolic rewiring.
10.A study on the suitability of HD-V2 film in ultra-high dose-rate electron beam dosimetry
Ronghu MAO ; Leijie MA ; Hongchang LEI ; Peng CHEN ; Bing LI ; Hui LUO ; Han LIU ; Xiuyan CHENG ; Wei GUO ; Hong GE
Chinese Journal of Radiation Oncology 2023;32(4):333-338
Objective:To evaluate the usability of Gafchromic HD-V2 film for dose dosimetry in the ultra-high dose-rate (UD) electron beam from a modified medical linac, and to investigate the response between the energy and dose-rate dependence to the film.Methods:The HD-V2 film was utilized to measure the average dose-rate of the UD electron beam. The measured result was compared with those by advanced Markus chamber and alanine pellets. And characteristics of the UD electron beam were also measured by HD-V2 film. Energy dependence of HD-V2 film at three beam energies (6 MV X-ray, 9 MeV and 16 MeV electron beam) was investigated by obtaining and comparing the calibration curves based on the clinical linear accelerator in the dose range of 10-300 Gy. The dose-rate dependence of HD-V2 film was also studied by varying the dose rate among 0.03 Gy/s, 0.06 Gy/s and 0.1 Gy/s, and range of 100-200 Gy/s.Results:The measured average maximum dose-rate of 9 MeV UD electron beam at source skin distance (SSD) 100 cm was approximately 121 Gy/s using HD-V2 film, consistent with the results by advanced Markus chamber and alanine pellets. The measured percentage depth dose (PDD) curve parameters of the UD electron beam were similar to the conventional 9 MeV beam. The off-axis dose distribution of the UD electron beam showed the highest central axis, and the dose was gradually decreased with the increase of off-axis distance. The energy dependence of HD-V2 film had no dependency of 6 MV and 9, 16 MeV while measuring the dose in the range from 20 to 300 Gy. The HD-V2 film had no significant dose-rate dependency at the dose rate of 0.03 Gy/s, 0.06 Gy/s and 0.1 Gy/s for the clinical linear accelerator. Likewise, there was also no dose-rate dependence in the range 100-200 Gy/s in the modified machine.Conclusion:HD-V2 film is suitable for measuring ultra-high dose rate electron beam, independent of energy and dose rate.

Result Analysis
Print
Save
E-mail