1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Discussion on processing time for Polygonatum kingianum based on analysis of correlation between sugar components and color changes
GUO Hong ; YAO Rui ; LI Zhe ; FAN Jing ; WANG Ying ; GUO Xiaohan ; CHEN Jia ; DUAN Baozhong ; YANG Jianbo ; JING Wenguang ; CHENG Xianlong ; WEI Feng
Drug Standards of China 2026;27(1):0083-0091
Objective: To investigate the correlation between color parameters (L*, a*, b*, Eab*) and the contents of reducing sugars, total polysaccharides, total oligosaccharides, as well as four saccharides (fructose, glucose, sucrose, and kestose) during the nine cycles of steaming and sun-drying processing of Polygonatum kingianum, and to preliminarily explore the optimal processing duration.
Methods: The color changes were objectively evaluated using a colorimeter. The anthrone-sulfuric acid method was employed to determine total polysaccharides and oligosaccharides. The 3,5-dinitrosalicylic acid (DNS) colorimetric method was used to measure total reducing sugar content. High-performance liquid chromatography coupled with charged aerosol detection (HPLC-CAD) was applied for quantitative analysis of fructose, glucose, sucrose, and kestose. Multivariate statistical analysis was conducted to assess samples from different processing stages.
Results: Significant variations in color and component contents were observed across processing stages. The herbal pieces progressively darkened with increased processing cycles: brightness (L*) and total color difference (Eab*) initially decreased then stabilized, while a* (red-green) and b* (yellow-blue) values first increased then declined. Total polysaccharides and oligosaccharides showed overall decreasing trends, whereas reducing sugars initially increased before stabilizing. Fructose and glucose levels rose continuously, while sucrose and kestose decreased progressively, becoming undetectable after five cycles.
Conclusion: The chromatic alteration and saccharide composition of P. kingianum showed significant correlation with processing duration. Both total color difference (Eab*) and reducing sugar content stabilized after four processing cycles (12 hours), suggesting that four cycles of steaming and sun-drying may represent the optimal processing duration.
3.Analytical research on processing techniques of Polygoni Multiflori Radix Praeparata based on chemical composition and color changes correlation
YAO Rui ; GUO Hong ; LI Zhe ; GUO Xiaohan ; ZHANG Xiaoshu ; DUAN Baozhong ; YANG Jianbo ; CHEN Jia ; JING Wenguang ; CHENG Xianlong ; WEI Feng
Drug Standards of China 2026;27(1):0100-0108
Objective: To investigate the correlation between the color parameters (L*, a*, b*, Eab* values) of Polygoni Multiflori Radix Praeparata powder prepared by different processing techniques and the contents of 2,3,5,4’-tetrahydroxystilbene-2-O-β-D-glucopyranoside, emodin, physcion, emodin-8-O-β-D-glucopyranoside, physcion-8-O-β-D-glucopyranoside.
Methods: The L*, a*, b* and Eab* values of Polygoni Multiflori Radix Praeparata powder prepared by different processing techniques were determined by spectrophotometer, and the contents of the five components were determined by high performance liquid chromatography. Secondly, SPSS 26.0 software and Simca 14.1 software were used to analyze the correlation.
Results: Through the hierarchical cluster analysis (HCA), it was found that the steamed samples and black bean steamed samples could be obviously divided into two categories: raw products and processed products. The processed products could be further divided into 2-8 h and 12-48 h. Pearson correlation analysis showed that the content of stilbene glycoside was significantly positively correlated with L*, a* and b* values (P<0.01). The a* value was significantly positively correlated with the content of emodin and physcion (P<0.01). Emodin-8-O-β-D-glucoside was positively correlated with L* value and b* value, while physcion-8-O-β-D-glucoside was negatively correlated with a* value. Partial least squares discriminant analysis (PLS) showed that 2,3,5,4’-tetrahydroxystilbene-2-O-β-D-glucoside (VIP=1.69) and emodin-8-O-β-D-glucoside (VIP=1.06) were the key variables affecting chromaticity characteristics (P<0.01).
Conclusion: The three processes of steaming, black bean steaming and black bean stewing are consistent in composition transformation and chromaticity variation, and stilbene glycoside can be used as a specific index component to characterize the processed color. Chromatic parameters can effectively reflect the processing progression and serve as quality monitoring indicators during production.
4.Predictive value of albumin,hemoglobin,and multifactorial model for poor postoperative prognosis in elderly patients with meningiomas
Yan-Yu GONG ; Hong QU ; Si-Zhe FENG ; Chun-Yong YU ; Jin-Wei DU ; Jin JIANG
Medical Journal of Chinese People's Liberation Army 2025;50(4):418-426
Objective To explore the predictive value of albumin,hemoglobin and multifactorial model for poor postoperative prognosis in elderly patients with meningioma.Methods A retrospective analysis was conducted on 253 elderly patients who underwent meningioma surgery and were transferred to the neurosurgical intensive care unit(NICU)at General Hospital of Northern Theater Command from January 2019 to September 2021,serving as the modeling cohort.Another 227 elderly patients who were treated in NICU after meningioma surgery from November 2021 to June 2023 were used as the validation cohort.Patients in the modeling cohort were categorized into good prognosis group[Glasgow Coma Scale(GCS)score>7,n=161]and poor prognosis group(GCS≤7,n=92)based on the GCS.Univariate and multifactorial logistic regression analyses were performed on the modeling cohort to identify independent risk factors,and a multifactorial model for predicting poor postoperative prognosis in elderly patients with meningioma was constructed based on these factors.The predictive efficacy and accuracy of the model were evaluated using the area under the receiver operating characteristic(ROC)curve(AUC),sensitivity,specificity,Hosmer-Lemeshow goodness-of-fit test,and calibration curves.The predictive value of postoperative albumin,hemoglobin,and the multifactorial models for postoperative prognosis in elderly meningioma patients was assessed using restricted cubic spline modeling(RCS),decision curves(DCA),and validated using an external validation cohort to assess the stability of the model.Results Meningioma WHO grade Ⅱand Ⅲ(OR=3.994,95%CI 1.963-8.126),postoperative hypoalbuminemia(OR=2.194,95%CI 1.079-4.462),and postoperative anemia(OR=2.117,95%CI 1.096-4.089)were identified as independent risk factors for poor postoperative prognosis in elderly meningioma patients(P<0.05),while the use of analgesic/sedative medications was a protective factor(OR=0.388,95%CI 0.201-0.748,P<0.05).The Hosmer-Lemeshow test indicated that the constructed multifactorial model had a good fit accuracy(P=0.161).The AUC for predicting poor postoperative prognosis in elderly meningioma patients for postoperative albumin and hemoglobin were 0.545(95%CI 0.472-0.617)and 0.632(95%CI 0.561-0.702),respectively,and showed a nonlinear dose-response relationship with prognosis(P<0.01).DCA analysis results showed that the net benefit rate of multifactorial model was higher than that of postoperative albumin and hemoglobin when the threshold probabilities were between 0.10 and 0.90.The AUC for predicting postoperative prognosis in the elderly meningioma patients in the modeling and validation cohorts were 0.810 and 0.819,respectively,and their calibration curves suggested good discrimination and accuracy.Conclusions Meningioma WHO grades Ⅱ and Ⅲ,postoperative anemia and hypoalbuminemia are independent risk factors for poor postoperative prognosis in elderly meningioma patients,while the use of analgesic/sedative drugs is a protective factor.The multifactorial model constructed based on these factors has a good predictive efficacy and credibility,and can be used as a reference for clinical decision-making.
5.Preparation of γ-Polyglutamic Acid Complex Medical Coating and Analysis of Its Antibacterial Properties
Ke LUAN ; Dong-Hua XU ; Ming-Zhe WANG ; Xu ZHANG ; Qiu-Yan YAN ; De-An SHI ; Rui WANG ; Heng-Chong SHI ; Hong XU
Chinese Journal of Analytical Chemistry 2025;53(7):1196-1203
Medical device related infections caused by bacteria are common complications in clinical practice,and preventing bacterial colonization on the surface of medical materials is one of the important challenges in the medical field.Therefore,there is an urgent need to construct medical coatings that combine antibacterial properties and biocompatibility.In this study,a γ-polyglutamic acid(γ-PGA)complex with long-chain alkyl quaternary ammonium salts formed by electrostatic and hydrophobic interactions was prepared,which was insoluble in water but soluble in organic solvents(e.g.,ethanol),and was capable of constructing antimicrobial coatings on the surfaces of medical materials in a simple and efficient manner.The bactericidal effect of the coating was verified using viable bacteria counting experiments,and the results showed that the bactericidal rate of the coated thermoplastic polyurethane(TPU)membrane against Staphylococcus aureus was greater than 99.9%compared with that of the uncoated TPU membrane.In addition,a cytotoxicity assay was performed using the L929 fibroblast and cell proliferation detection kit(CCK-8),which showed that the survival rate of L929 fibroblasts on coated TPU was greater than 90%.Meanwhile,the hemolysis rate of coated erythrocytes was tested using fresh rabbit red blood cells(RBCs),and the hemolysis rate on the coated TPU surface was 1.5%.The above results indicated that the coating had good biocompatibility.The preparation method of medical antibacterial coating reported in this study provided a new idea for preventing bacterial infections related to implantable/interventional medical devices.
6.Creation and Exploration of the"Organized Fill-in-the-Blank Format"Disci-pline Construction Model for Forensic Medicine in the New Era
Zhi-Wen WEI ; Hong-Xing WANG ; Jun-Hong SUN ; Hao-Liang FAN ; Hong-Liang SU ; Le-Le WANG ; Wen-Ting HE ; Zhe CHEN ; Jie ZHANG ; Xiang-Jie GUO ; Ji LI ; Geng-Qian ZHANG ; Xin-Hua LIANG ; Jiang-Wei YAN ; Qiang-Qiang ZHANG ; Cai-Rong GAO ; Ying-Yuan WANG ; Hong-Wei WANG ; Jun XIE ; Bo-Feng ZHU ; Ke-Ming YUN
Journal of Forensic Medicine 2025;41(1):25-29
Forensic medicine has been designated as a first-level discipline,presenting new opportunities and challenges for the development of forensic medicine.Since the 1980s,the establishment of foren-sic medicine discipline and the cultivation of high-level forensic talents have become hot topics in the development of forensic medicine in China.Since the 13th Five-Year Plan,the forensic team of Shanxi Medical University has been aiming at the forefront,proposing the development goals of"Five First-class"and the discipline development path"Six Major Achievements".It has selected benchmark disci-plines,identified gaps in disciplinary development,unified thoughts,formulated completion timelines,concentrated superior resources,assigned tasks to individuals,and created an"Organized Fill-in-the-Blank Format"forensic medicine discipline construction model with the characteristics of the new era.The construction model of forensic medicine has achieved good results in the goals,discipline frame-work,scientific research,talent cultivation,discipline team and platform construction,forming a rela-tively complete discipline construction and management system,and accumulating valuable experience for the construction of first-level discipline and high-level talent cultivation of forensic medicine.
7.Translational Research of Electromagnetic Fields on Diseases Related With Bone Remodeling: Review and Prospects
Peng SHANG ; Jun-Yu LIU ; Sheng-Hang WANG ; Jian-Cheng YANG ; Zhe-Yuan ZHANG ; An-Lin LI ; Hao ZHANG ; Yu-Hong ZENG
Progress in Biochemistry and Biophysics 2025;52(2):439-455
Electromagnetic fields can regulate the fundamental biological processes involved in bone remodeling. As a non-invasive physical therapy, electromagnetic fields with specific parameters have demonstrated therapeutic effects on bone remodeling diseases, such as fractures and osteoporosis. Electromagnetic fields can be generated by the movement of charged particles or induced by varying currents. Based on whether the strength and direction of the electric field change over time, electromagnetic fields can be classified into static and time-varying fields. The treatment of bone remodeling diseases with static magnetic fields primarily focuses on fractures, often using magnetic splints to immobilize the fracture site while studying the effects of static magnetic fields on bone healing. However, there has been relatively little research on the prevention and treatment of osteoporosis using static magnetic fields. Pulsed electromagnetic fields, a type of time-varying field, have been widely used in clinical studies for treating fractures, osteoporosis, and non-union. However, current clinical applications are limited to low-frequency, and research on the relationship between frequency and biological effects remains insufficient. We believe that different types of electromagnetic fields acting on bone can induce various “secondary physical quantities”, such as magnetism, force, electricity, acoustics, and thermal energy, which can stimulate bone cells either individually or simultaneously. Bone cells possess specific electromagnetic properties, and in a static magnetic field, the presence of a magnetic field gradient can exert a certain magnetism on the bone tissue, leading to observable effects. In a time-varying magnetic field, the charged particles within the bone experience varying Lorentz forces, causing vibrations and generating acoustic effects. Additionally, as the frequency of the time-varying field increases, induced currents or potentials can be generated within the bone, leading to electrical effects. When the frequency and power exceed a certain threshold, electromagnetic energy can be converted into thermal energy, producing thermal effects. In summary, external electromagnetic fields with different characteristics can generate multiple physical quantities within biological tissues, such as magnetic, electric, mechanical, acoustic, and thermal effects. These physical quantities may also interact and couple with each other, stimulating the biological tissues in a combined or composite manner, thereby producing biological effects. This understanding is key to elucidating the electromagnetic mechanisms of how electromagnetic fields influence biological tissues. In the study of electromagnetic fields for bone remodeling diseases, attention should be paid to the biological effects of bone remodeling under different electromagnetic wave characteristics. This includes exploring innovative electromagnetic source technologies applicable to bone remodeling, identifying safe and effective electromagnetic field parameters, and combining basic research with technological invention to develop scientifically grounded, advanced key technologies for innovative electromagnetic treatment devices targeting bone remodeling diseases. In conclusion, electromagnetic fields and multiple physical factors have the potential to prevent and treat bone remodeling diseases, and have significant application prospects.
8.Finite element analysis of three internal fixation modalities for treatment of Pauwels type Ⅲ femoral neck fractures under different loading conditions
Zhenggang LI ; Xuehong SHANG ; Zhang WU ; Hong LI ; Chaojun SUN ; Huadong CHEN ; Zhe SUN ; Yi YANG
Chinese Journal of Tissue Engineering Research 2025;29(3):455-463
BACKGROUND:There is still no consensus on the optimal internal fixation for the treatment of Pauwels Ⅲ femoral neck fracture,and most of the related finite element analyses have been performed using a single simplified loading condition,and the biomechanical properties of commonly used internal fixation devices need to be further investigated. OBJECTIVE:To analyze the biomechanical characteristics of Pauwels Ⅲ femoral neck fractures treated with cannulated compression screw,dynamic hip screw,and femoral neck system by finite element method under different loading conditions of single-leg standing loads and sideways fall loads. METHODS:The DICOM data of healthy adult femur were obtained by CT scanning,imported into Mimics 15.0 software to obtain the rough model of bone tissue.The data exported from Mimics were optimized by Geomagics software,and then three internal fixation models were built and assembled with the femur model according to the parameters of the clinical application of the cannulated compression screw,dynamic hip screw,and femoral neck system by using Pro/E software.Finally,the three internal fixation models were imported into Ansys software for loading and calculation to analyze the stress distribution and displacement of the femur and the internal fixation under different working conditions of single-leg standing loads and sideways fall loads,as well as the stress characteristics of the calcar femorale and Ward's triangle. RESULTS AND CONCLUSION:(1)Under the single-leg standing load and the sideways fall load,the proximal femoral stress of the three internal fixation models was mainly distributed above the fracture end of the femoral neck.The peak stress of the proximal femoral end,fracture end,Ward triangle,and calcar femorale of the three internal fixation models were the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(2)Under the single-leg standing load and the sideways fall load,the peak displacement of the proximal femur of the three internal fixation models was all located at the top of the femoral head,and the peak displacement was the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(3)The peak displacement of the three internal fixation models was all located at the top of the internal fixation device under the single-leg standing and sideways fall loading conditions,and the peak displacement values were the smallest in the femoral neck system internal fixation model and the largest in the cannulated compression screw internal fixation model.(4)The internal fixation stress of the three internal fixation models was mainly distributed in the area near the fracture end of the internal fixation device under the single-leg standing and sideways fall loads,and the peak value of internal fixation stress was the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(5)These results suggest that the mechanical stability of the femoral neck system is the best,but there may be a risk of stress shielding of the fracture end and calcar femorale.The stress of the internal fixation device of the femoral neck system is more dispersed,and the risk of internal fixation break is lower.
9.Loss-of-function mutations in Chinese Han patients with familial benign chronic pemphigus are associated with an earlier age at onset
Xueying WANG ; Zhenzhen WANG ; Zhe WANG ; Zihao MI ; Lele SUN ; Hong LIU ; Furen ZHANG
Chinese Journal of Dermatology 2025;58(3):221-227
Objective:To expand the mutation spectrum of familial benign chronic pemphigus (HHD), and to deeply explore the relationship between clinical phenotypes and genotypes.Methods:HHD patients were retrospectively collected from the Department of Dermatology, Hospital for Skin Diseases, Shandong First Medical University from January 2018 to October 2023, and their clinical data and blood samples were also collected. Sanger sequencing and Whole-exome sequencing were performed on 34 HHD patients. Mutations in the ATP2C1 gene were classified into loss-of-function mutations (including frameshift mutations, nonsense mutations, and splicing mutations) and missense mutations. The relationship between clinical phenotypes and genetic mutation types was analyzed using Fisher's exact test or two-independent-sample t test, and further verified by meta-analysis. Results:The 34 HHD patients were all of Chinese Han nationality, including 20 males and 14 females, and their ages ranged from 35 to 77 years. Pathogenic mutations in the ATP2C1 gene were successfully identified in all the 34 patients, including 29 independent mutations, among which there were 9 frameshift mutations, 8 splicing mutations, 6 missense mutations, and 6 nonsense mutations. The age at onset was significantly earlier in the loss-of-function mutation group (37.62 ± 10.10 years) than in the missense mutation group (49.63 ± 14.90 years; t = 2.62, P = 0.013). However, there were no significant differences in gender, family history, disease seasonality, disease severity, or disease progression among patients with different mutation types (all P > 0.05). Meta-analysis showed that the age at onset was significantly earlier in Chinese Han patients with HHD carrying loss-of-function mutations than in those carrying missense mutations (mean difference: -4.61 years, 95% CI: -8.68 - -0.53 years, P = 0.030) . Conclusion:Chinese Han patients with HHD carrying loss-of-function mutations in the ATP2C1 gene showed significantly earlier ages at onset compared with those carrying missense mutations.
10.A multicenter retrospective study of secondary transport on extracorporeal membrane oxygenation in critically ill children
Zhe ZHAO ; Ye CHENG ; Xiaohong WU ; Yingyue LIU ; Mai LI ; Xiaoyu HE ; Wenzhe CHENG ; Feng WANG ; Yuxiong GUO ; Mingxia ZHANG ; Guodong HUANG ; Guoping LU ; Yuhan CHEN ; Kenan FANG ; Xiaoyang HONG
Chinese Journal of Pediatrics 2025;63(3):243-248
Objective:To evaluate the safety and efficacy of secondary transport on extracorporeal membrane oxygenation (ECMO) for critically ill children.Methods:This was a retrospective cohort study. Data from 222 pediatric patients who underwent ECMO transport from May 2019 to May 2024 at 5 ECMO centers and Chinese Database of Pediatric Extracorporeal Life Support Organization were collected. The cases were divided into primary and secondary transport groups by nature of transport. The clinical data, including demographics, ECMO indications, transport distance, pre-transport lab results, prognosis and complications were analyzed. Two independent samples t-test, Wilcoxon test, and χ2 test or Fisher′s exact probability method were used to compare the differences between 2 groups and evaluate the safety and efficacy of secondary transport. Results:Among the 222 children transported with ECMO, there were 135 males and 87 females, with an age of 3.0 (0.2, 7.0) years. There were 202 cases in the primary transport group and 20 cases in the secondary transport group. All secondary transport patients had failed attempts at weaning ECMO before transfer. The patients in the secondary transport group were older, had higher rates of surgical cannulation, circulatory support, and pre-ECMO lactate levels compared to the primary transport group (7.0 (2.8, 10.0) vs. 3.0 (0.2, 6.0) years old, 55.0% (11/20) vs. 3.6% (7/202), 80.0% (16/20) vs. 41.6% (84/202), (10±4) vs. (7±6) mmol/L, Z=3.41, χ 2=66.31, 10.99, t=2.24, all P<0.05). In the secondary transport group, the vasoactive-inotropic scores of patients on circulatory support and the oxygenation index for patients requiring respiratory support were higher than those in the primary transport group (83±33 vs. 82±68, 51.0±1.8 vs. 37.4±10.2, t=2.36, 2.63, respectively; both P<0.05). There were no statistically significant differences between the 2 groups in sex, transport distance, pre-ECMO creatinine, arterial blood gas BE values, and ECMO duration (all P>0.05). No life-threatening complications occurred during the transport in either group. Two patients in the secondary transport group underwent heart transplantation, and 1 patient underwent radiofrequency ablation. The overall survival rate between the 2 groups showed no statistically significant difference (45.0% (9/20) vs. 55.4% (112/202), χ2=1.15, P>0.05). Conclusions:Secondary ECMO transport for critically ill children don't increase mortality or life-threatening complications during transport. ECMO patients who cannot receive effective treatment locally can benefit from secondary transport to an advanced ECMO center provides further treatment opportunities.

Result Analysis
Print
Save
E-mail