1.Research Progressin Application of Ultrasound in the Diagnosis and Treatment of Greater Trochanteric Pain Syndrome.
Fan WU ; Yi MAO ; Chun-Bao LI ; Long-Tao YAN ; Ming-Bo ZHANG
Acta Academiae Medicinae Sinicae 2025;47(2):289-294
Greater trochanteric pain syndrome(GTPS)is a disease caused by structural lesions of the muscles,fascia,ligaments,and bursae near the greater trochanter of the femur.GTPS causes lateral hip joint pain,severely affecting patients' quality of life.Ultrasound has many advantages,such as real-time diagnosis,portable operation,non-radiation,and high resolution,demonstrating a high application value in the diagnosis and interventional therapy of GTPS.This article reviews the current status of ultrasound in the diagnosis and interventional therapy of GTPS and prospects its application.
Humans
;
Ultrasonography
;
Femur/diagnostic imaging*
;
Hip Joint/diagnostic imaging*
;
Arthralgia/therapy*
2.Postoperative urinary retention following hip or knee arthroplasty under spinal anaesthesia with intrathecal morphine: a retrospective cohort study.
Elad DANA ; Oz BEN-ZUR ; Sara DICHTWALD ; Guy FEIGIN ; Noa BRIN ; Michael MARKUSHEVICH ; Brian FREDMAN ; Yaron Shraga BRIN
Singapore medical journal 2025;66(9):481-485
INTRODUCTION:
Postoperative urinary retention (POUR) frequently complicates the course of patients following hip and knee arthroplasty. Intrathecal morphine (ITM) was identified as a significant risk factor for POUR. The objective of this study was to investigate the incidence and risk factors for POUR in fast-track total joint arthroplasty (TJA) under spinal anaesthesia (SA) with ITM.
METHODS:
We conducted a retrospective study of our institutional joint registry of patients who underwent primary TJA under SA with ITM between October 2017 and May 2021. Preoperative (baseline demographics) and perioperative data were collected. The primary outcome was the incidence of POUR after 8 h or earlier, either due to lack of voiding or according to patient's complaints of bladder distension. Univariate and adjusted analyses were performed to identify predictors of POUR.
RESULTS:
Sixty-nine patients who underwent total knee arthroplasty (TKA) and 36 patients who underwent total hip arthroplasty (THA) under SA with ITM were included in the study. POUR requiring bladder catheterisation was diagnosed in 21% of patients. Independent predictors of POUR were age over 65 years and male gender.
CONCLUSIONS
SA with ITM for TJA is associated with high rates of POUR in males older than 65 years of age. Other previously identified risk factors such as intraoperative fluid administration or comorbidities may not be as influential.
Humans
;
Retrospective Studies
;
Male
;
Urinary Retention/epidemiology*
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Anesthesia, Spinal/adverse effects*
;
Female
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Morphine/adverse effects*
;
Aged
;
Middle Aged
;
Risk Factors
;
Postoperative Complications/epidemiology*
;
Injections, Spinal
;
Incidence
;
Analgesics, Opioid/adverse effects*
;
Aged, 80 and over
3.Effectiveness analysis of arthroscopic outside-in release for gluteal muscle contracture in supine position.
Di JIA ; Qiguo RAN ; Fei SUN ; Kun ZHANG ; Yanlin LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(7):848-854
OBJECTIVE:
To compare the effectiveness of arthroscopic outside-in release for gluteal muscle contracture (GMC) in supine position versus lateral decubitus position.
METHODS:
The clinical data of 34 GMC patients meeting selection criteria between January 2022 and May 2023 were retrospectively analyzed. Arthroscopic contracture band release was performed in the lateral decubitus position (lateral group, n=14) or the supine position (supine group, n=20). No significant difference ( P>0.05) was observed between groups in baseline data, including gender, age, body mass index, preoperative GMC functional quantitative score, modified Harris hip score (mHHS), visual analogue scale (VAS) pain score, and hip flexion/adduction range of motion (ROM). The total operation time, release procedure time, non-release procedure time, intraoperative blood loss, hospital stay, and postoperative complications were recorded and compared. Functional outcomes (GMC functional quantitative score, mHHS score, VAS score, hip flexion/adduction ROM) were evaluated preoperatively and at 3, 12, and 24 months postoperatively.
RESULTS:
All incisions healed by first intention without major vascular or neurological complications. In the lateral group, 3 patients developed patchy bruising on bilateral buttocks and posterior thighs at 3 days after operation, which resolved after 2 weeks of ice packs and ultrasonic therapy. The supine group demonstrated significantly shorter total operation time, non-release procedure time, hospital stay, and reduced intraoperative blood loss versus the lateral group ( P<0.05). No significant difference was found in release procedure time ( P>0.05). All patients were followed up 24 months. Both groups showed significant improvements ( P<0.05) in mHHS score, GMC functional quantitative score, VAS score, and hip adduction/flexion ROM at all postoperative timepoints compared to preoperative values, with no significant intergroup differences ( P>0.05).
CONCLUSION
Both surgical positions effectively improve hip function in GMC patients. However, the supine position offers significant advantages over the lateral decubitus position in operation time, anesthesia management, intraoperative blood loss control, and reduced hospital stay.
Humans
;
Male
;
Female
;
Arthroscopy/methods*
;
Retrospective Studies
;
Buttocks/surgery*
;
Adult
;
Range of Motion, Articular
;
Supine Position
;
Treatment Outcome
;
Middle Aged
;
Contracture/surgery*
;
Muscle, Skeletal/surgery*
;
Young Adult
;
Operative Time
;
Hip Contracture/surgery*
;
Patient Positioning/methods*
4.Diagnostic value of 99mTc-MDP three-phase bone scintigraphy combined with C-reaction protein for periprosthetic joint infection.
Guojie LIU ; Xiaolan SONG ; Pei ZHAI ; Shipeng SONG ; Weidong BAO ; Yawei DUAN ; Wei ZHANG ; Yafeng LIU ; Yongqiang SUN ; Shuailei LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1180-1186
OBJECTIVE:
To investigate the diagnostic efficacy of 99mTc-MDP three-phase bone scintigraphy (TPBS) combined with C-reactive protein (CRP) for periprosthetic joint infection (PJI).
METHODS:
The clinical data of 198 patients who underwent revision surgery of artificial joint between January 2017 and January 2024 and received TPBS examination before surgery were retrospectively analyzed. There were 77 males and 121 females with an average age of 63.74 years ranging from 24 to 92 years. There were 90 cases of hip arthroplasty and 108 cases of knee arthroplasty. PJI was diagnosed according to the 2013 American Musculoskeletal Infection Society (MSIS) standard diagnostic criteria. The sensitivity, specificity, accuracy, negative predictive value (NPV), and positive predict value (PPV) were calculated. The receiver operating characteristic (ROC) curve was used to compare the diagnostic performance of the three methods, and the area under curve (AUC) was used to evaluate the diagnostic performance.
RESULTS:
According to the 2013 MSIS criteria, 116 cases were diagnosed as PJI, and the remaining 82 cases were aseptic loosening. The cases of PJI diagnosed by TPBS, CRP, and TPBS-CRP were 125, 109, and 137 respectively, and the cases of aseptic loosening were 73, 89, and 61 respectively. The sensitivity, accuracy, NPV, and PPV of TPBS-CRP combination in the diagnosis of PJI were higher than those of TPBS and CRP, but the specificity was lower than that of TPBS and CRP. ROC curve analysis further showed that the AUC value of TPBS-CRP combination was better than that of TPBS and CRP. The severity of bone defect and the duration of symptoms in patients with false positive TPBS diagnosis were worse than those in patients with true negative TPBS diagnosis (P<0.05), but there was no significant difference in the survival time of prosthesis between the two groups (P>0.05). Among the patients diagnosed with PJI by TPBS, CRP, and TPBS-CRP, 49, 35, and 54 patients had received antibiotic treatment 2 weeks before diagnosis, respectively. There was no significant difference in the diagnostic accuracy of TPBS and TPBS-CRP before diagnosis between patients treated with and without antibiotics and those not treated (P>0.05). The diagnostic accuracy of antibiotic therapy before CRP diagnosis was significantly lower than that of untreated patients (P<0.05).
CONCLUSION
TPBS and CRP have limited specificity in differentiating PJI from aseptic loosening. The TPBS-CRP combination diagnostic method can synergize the local bone metabolic characteristics and systemic inflammatory response to achieve higher diagnostic accuracy, but caution should be exercised in patients with severe bone defects and longer symptom duration.
Humans
;
Prosthesis-Related Infections/blood*
;
Middle Aged
;
Male
;
Female
;
Aged
;
C-Reactive Protein/metabolism*
;
Retrospective Studies
;
Adult
;
Radionuclide Imaging/methods*
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Aged, 80 and over
;
Technetium Tc 99m Medronate
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Sensitivity and Specificity
;
Knee Prosthesis/adverse effects*
;
ROC Curve
;
Reoperation
;
Radiopharmaceuticals
;
Young Adult
5.2024 American Academy of Orthopaedic Surgeons (AAOS) Clinical Practice Guideline: Management of Osteoarthritis of the Hip (summary) interpretation.
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1325-1332
Hip osteoarthritis (OA) is a significant disease worldwide that causes functional impairment and reduced quality of life. With the aging of the population and the increasing prevalence of obesity, its disease burden is becoming increasingly heavy. In December 2023, the American Academy of Orthopaedic Surgeons (AAOS) released the updated Clinical Practice Guideline for the Management of Osteoarthritis of the Hip (summary). Based on evidence-based medicine, this guideline provides systematic recommendations for the diagnosis and treatment of hip OA. This article will comprehensively interpret the guideline, compare it with relevant domestic expert consensus in China, analyze the consistency and differences in disease management strategies between the two, and provide references for clinical practice.
Humans
;
Academies and Institutes
;
Arthroplasty, Replacement, Hip
;
China
;
Evidence-Based Medicine
;
Orthopedic Surgeons
;
Orthopedics
;
Osteoarthritis, Hip/surgery*
;
Quality of Life
;
United States
6.Anteromedial cortical support reduction in treatment of trochanteric femur fractures: a ten-year reappraisal.
Sunjun HU ; Shouchao DU ; Shimin CHANG ; Wei MAO ; Zhenhai WANG ; Kewei TIAN ; Tao LIU ; Yunfeng RUI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1501-1509
OBJECTIVE:
This review summarized the first 10-year progresses and controversies in the concept of anteromedial cortical support reduction, to provide references for further study and clinical applications.
METHODS:
Relevant domestic and foreign literature on cortical support reduction was extensively reviewed to summarize the definition of positive, neutral, and negative support, anteromedial cortices at the inferior corner, intraoperative technical tips for fracture reduction, radiographic assessment at different periods, comparison between positive versus neutral and medial versus anterior support, and the clinical efficacy of Chang reduction quality criteria (CRQC) and postoperative stability score.
RESULTS:
Anteromedial cortical support reduction was only focused on the cortex of anteromedial inferior corner, with no concern the status of lateral wall or lesser trochanter. Anteromedial cortex was seldom involved by fracture comminution, it was thicker, denser, and stronger, and was the key for mechanical buttress of the head-neck fragment to share compression load. Positive, neutral, and negative support were also called "extramedullary, anatomic, and intramedullary reduction", respectively. There was hardly seen parallel cortical apposition, but characterized by some kinds of head-neck rotation, for example 10°-15° flexed rotation for positive cortical contact and support. Due to intraoperative compression and postoperative impaction, the status of cortical support may be changed at different time of radiographic examination. The positive medial cortex support was more reliable with less reduction loss than its neutral counterpart, and the anterior cortex contact was more predictive than the medial cortex for final results. As incorporation the bearing of cortex apposition and using a 4-point score, CRQC demonstrated more efficacy and was gradually accepted and applied in the evaluation of trochanteric fracture reduction quality. Postoperative stability score (8 points) provided a assessment tool for early weight-bearing in safety to prevent mechanical failure.
CONCLUSION
Anteromedial cortical support reduction is a key point for stability reconstruction in the treatment of trochanteric femur fractures. Evidence has definitely shown that non-negative (positive and neutral) is superior to negative (loss of cortical support). There is a tendency that positive cortex support is superior to neutral, but high quality study with large sample size is needed for a clear conclusion.
Humans
;
Femur/diagnostic imaging*
;
Fracture Fixation, Internal/methods*
;
Hip Fractures/diagnostic imaging*
;
Treatment Outcome
;
Fracture Fixation, Intramedullary/methods*
7.Early follow-up study on three-dimensional-printed customized porous acetabular components for reconstructing extensive acetabular bone defects in primary total hip arthroplasty.
Shangkun TANG ; Zhuangzhuang LI ; Xin HU ; Linyun TAN ; Hao WANG ; Yitian WANG ; Minxun LU ; Fan TANG ; Yi LUO ; Yong ZHOU ; Chongqi TU ; Li MIN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1543-1550
OBJECTIVE:
To evaluate the feasibility and short-term effectiveness of three-dimensional (3D)-printed customized porous acetabular components for reconstruction of extensive acetabular bone defects during primary total hip arthroplasty (THA).
METHODS:
The clinical data of 8 patients with extensive acetabular bone defects, who were treated with 3D-printed individualized porous acetabular components between July 2018 and January 2022, were retrospectively analyzed. The cohort comprised 4 males and 4 females with an average age of 48 years ranging from 34 to 56 years. Acetabular bone defects were classified as Paprosky type ⅢA in 3 cases and type ⅢB in 5 cases. The causes of acetabular destruction were hip tuberculosis (5 cases), pigmented villonodular synovitis (2 cases), and syphilitic arthritis (1 case). Visual analogue scale (VAS) score and Harris hip score (HHS) were used to evaluate the pain relief and hip function before and after operation. Reconstruction outcomes were further assessed by imaging results [X-ray film and Tomosynthesis Shimadzumetal artefact reduction technology (T-SMART)], and the mechanical properties were evaluated by finite element analysis.
RESULTS:
The operation time ranged from 174 to 195 minutes (mean, 187 minutes), and intraoperative blood loss ranged from 390 to 530 mL (mean, 465 mL). All 8 patients were follow-up 26-74 months (mean, 44 months). Among the 5 patients with tuberculosis, none experienced postoperative recurrence. At last follow-up, the VAS score was 0.3±0.5 and the HHS score was 87.9±3.7, both significantly improved compared to preoperative values ( t=25.170, P<0.001; t=-28.322, P<0.001). X-ray films at 2 years after operation demonstrated satisfactory matching between the 3D-printed customized acetabular component and the acetabulum. The postoperative center of rotation of the operated hip was shifted by (2.1±0.5) mm horizontally and (2.0±0.7) mm vertically relative to the contralateral side, with both offsets showing significant differences compared to preoperative values ( t=24.700, P<0.001; t=55.230, P<0.001). T-SMART imaging showed satisfactory osseointegration at the implant-host bone interface. No complications such as aseptic loosening or screw breakage was observed during follow-up. Finite element analysis showed that the acetabular component had good mechanical properties.
CONCLUSION
The application of 3D-printed individualized porous acetabular components in the reconstruction of extensive acetabular bone defects demonstrated precise anatomical reconstruction, stable mechanical support, and good functional performance in short-term follow-up, offering a potential alternative for acetabular defect reconstruction in primary THA.
Humans
;
Middle Aged
;
Male
;
Female
;
Printing, Three-Dimensional
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Acetabulum/diagnostic imaging*
;
Adult
;
Follow-Up Studies
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Porosity
;
Treatment Outcome
;
Plastic Surgery Procedures/methods*
8.Effectiveness of arthroscopic treatment for femoroacetabular impingement syndrome combined with ligamentum teres injury.
Siyu HAN ; Song LI ; Di JIA ; Yanlin LI ; Guofeng CAI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1551-1555
OBJECTIVE:
To investigate the effectiveness of hip arthroscopy in the treatment of patients with femoroacetabular impingement (FAI) syndrome combined with ligamentum teres injury.
METHODS:
A retrospective analysis was conducted on 23 patients (23 hips) with Cam-type FAI syndrome combined with ligamentum teres injury who met the selection criteria between April 2022 and May 2024. The cohort included 12 males and 11 females, with a mean age of 29.16 years (range, 16-57 years). According to Tönnis classification, there were 5 cases of grade 0, 10 cases of grade Ⅰ, and 8 cases of grade Ⅱ in hip osteoarthritis. The disease duration ranged from 6 to 24 months, with an average of 12 months. Under hip arthroscopy, hypertrophic synovium and the damaged ligamentum teres were debrided, while the torn labrum and cartilage were repaired, and femoral head-neck osteoplasty was performed to eliminate impingement, restore the normal morphology of the acetabulum and femoral head-neck, and suture the joint capsule. Acetabular lateral center-edge angle (LCEA) and α angle (reflecting the degree of non-sphericity at the femoral head-neck junction) were measured before and after operation, and the modified Harris hip score (mHHS), the International Hip Outcome Tool-12 (IHOT-12), and the visual analogue scale (VAS) score for pain were evaluated.
RESULTS:
The operation was successfully completed in all patients. The incisions healed by first intention after operation, and there was no perioperative complications such as iatrogenic cartilage injury, fracture, infection, neurovascular traction injury, or lower extremity venous thrombosis. All the 23 patients were followed up 12-24 months, with an average of 14.6 months. The pain of hip joint significantly relieved, and the function of hip joint improved; no complication such as joint stiffness, joint instability, and osteonecrosis of the femoral head occurred. The α angle, VAS score, mHHS score, and IHOT-12 score at last follow-up were significantly better than those before operation ( P<0.05); there was no significant difference in LCEA compared to preoperative value ( P>0.05).
CONCLUSION
Hip arthroscopy is a safe and effective treatment for patients with FAI syndrome combined with ligamentum teres injury, which can achieve satisfactory effectiveness.
Humans
;
Femoracetabular Impingement/complications*
;
Arthroscopy/methods*
;
Adult
;
Male
;
Female
;
Retrospective Studies
;
Middle Aged
;
Adolescent
;
Treatment Outcome
;
Young Adult
;
Hip Joint/surgery*
;
Acetabulum/surgery*
;
Round Ligaments/surgery*
;
Range of Motion, Articular
9.Preoperative diagnostic efficacy of novel blood markers white blood cell ratio and fibrinogen levels in periprosthetic joint infection.
Geng-Yao ZHU ; Chao MA ; Guang-Wang LIU ; Jia-Zheng MAN
China Journal of Orthopaedics and Traumatology 2025;38(1):55-60
OBJECTIVE:
To investigate the clinical utility of novel of new hematological markers in the preoperative diagnosis of periprosthetic joint infection (PJI).
METHODS:
A retrospective analysis was conducted on a total of 149 patients who underwent revision of total hip arthroplasty (THA) or total knee arthroplasty (TKA) at a single center between January 2016 and June 2022, including 63 males and 86 females, aged from 47 to 93 years old with an average of (69.5±11.8) years old. Of them, 46 were diagnosed as PJI(PJI group), including 22 males and 24 females. The mean age was (71.3±12.5) years old. The body mass index (BMI) was (26.4±3.1) kg·m-2. And 103 patients were diagnosed as aseptic prosthesis loosening (aseptic group), including 41 males and 62 females. The mean age was (68.7±11.4) years old. The BMI was (25.8±3.5) kg·m-2. Preoperatively analyzed clinical parameters included C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), albumin, globulin, albumin-to-globulin ratio (AGR), plasma D-dimer, and plasma fibrinogen. The receiver operating characteristic curve (ROC), sensitivity, and specificity analysis were employed to compare the diagnostic value of each blood marker in preoperative PJI diagnosis.
RESULTS:
In the PJI group, the levels of CRP were 16.6 (7.6, 4.5) mg·L-1, ESR was 17.0 (12.8, 35.5) mm·h-1, plasma D-dimer was 1.0 (0.5, 3.1) μg·L-1, and plasma fibrinogen was 4.2 (3.2, 3.1) mg·L-1;all of which were higher compared to the aseptic group with CRP at 4.2 (2.6, 7.8) mg·L-1, ESR at 12.0(8.0, 20.0 )mm·h-l, D-dimer at 0.4(0.2, 0.7)μg·L-1, and fibrinogen at 2.8(2.4, 3.3 ) g·L-1(P<0.05). However, the albumin level of 35.3 (32.3, 37.5) g·L-1 and the WBC ratio of 1.0(0.9, 1.1) in the PJI group were significantly lower compared to the aseptic group with levels of 39.8 (36.1, 41.8) g·L-1 and 1.4 (1.3, 1.5), respectively (P<0.05). Only the area under the curve (AUC) of AGR and plasma fibrinogen were greater than 0.8. The optimal predictive cut-1off, AUC, sensitivity and specificity were 3.4 g·L-1, 0.820, 69.57% and 84.47% for plasma fibrinogen; 1.18, 0.813, 82.61% and 78.64% for AGR, respectively.
CONCLUSION
AGR and plasma fibrinogen are promising blood markers for improving the diagnosis of PJI.
Humans
;
Female
;
Fibrinogen/metabolism*
;
Male
;
Middle Aged
;
Aged
;
Prosthesis-Related Infections/blood*
;
Retrospective Studies
;
Biomarkers/blood*
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Leukocyte Count
10.Risk factors for cutout failure in geriatric intertrochanteric fracture patients after cephalomedullary nail fixation.
You-Liang HAO ; Fang ZHOU ; Hong-Quan JI ; Yun TIAN ; Zhi-Shan ZHANG ; Yan GUO ; Yang LYU ; Zhong-Wei YANG ; Guo-Jin HOU
China Journal of Orthopaedics and Traumatology 2025;38(2):141-147
OBJECTIVE:
To determine risk factors for cutout failure in geriatric intertrochanteric fracture patients after cephalomedullary nail fixation.
METHODS:
A retrospective review of 518 elderly patients who underwent cephalomedullary nail fixation for intertrochanteric fractures between January 2008 and August 2018 was conducted, including 167 males and 351 females, age from 65 to 97 years old. All patients were followed up for at least one year after surgery and divided into a healed group and a cutout group based on whether the hip screw cutout occurred. Among all patients, 10 cases experienced hip screw cutout. The general information, surgical data, and radiological data of the two groups were compared, and risk factors influencing hip screw cutout were analyzed. Propensity score matching was then performed on the cutout group based on gender, age, body mass index(BMI), and American Society of Anesthesiologists(ASA), and 40 patients from the healed group were matched at a ratio of 1∶4. Key risk factors affecting hip screw cutout were further analyzed. Multivariable logistic regression analysis was conducted to evaluate associations between variables and cutout failure.
RESULTS:
There were no statistically significant differences between the healed group and the cutout group in terms of age, gender, BMI, ASA, and AO classification. However, statistically significant differences were observed between the two groups in terms of reduction quality(P=0.003) and tip-apex distance(TAD), P<0.001. Multivariate analysis identified poor reduction quality OR=23.138, 95%CI(2.163, 247.551), P=0.009 and TAD≥25 mm OR=30.538, 95%CI(2.935, 317.770), P=0.004 as independent risk factors for cutout failure.
CONCLUSION
The present study identified poor reduction quality and TAD≥25 mm as factors for cutout failure in geriatric intertrochanteric fractures treated with cephalomedullary nails. Further studies are needed to calculate the optimal TAD for cephalomedullary nails.
Humans
;
Male
;
Female
;
Hip Fractures/surgery*
;
Aged, 80 and over
;
Aged
;
Risk Factors
;
Retrospective Studies
;
Fracture Fixation, Intramedullary/adverse effects*
;
Bone Nails
;
Bone Screws

Result Analysis
Print
Save
E-mail