1.Comparative study of cardiac morphology, size and function between fetuses with tetralogy of Fallot and fetuses with malalignment ventricular septal defect and pulmonary stenosis by multi-parameter quantitative echocardiography
Shuli YANG ; Bowen ZHAO ; Mei PAN ; Xiaohui PENG ; Ran CHEN ; Yuanshi TIAN ; Min DI ; Heqing GUO
Chinese Journal of Ultrasonography 2025;34(2):139-148
Objective:To analyze the differences in heart size,shape and function between fetuses with tetralogy of Fallot(TOF)and fetuses with malalignment ventricular septal defect(VSD)and pulmonary stenosis(PS)(named as,mild TOF)by fetal heart quantification(fetal HQ)and multi-parameter fetal echocardiography.Methods:From June 2021 to June 2023,50 fetuses with TOF(TOF group)diagnosed by fetal echocardiography at the Department of Diagnostic Ultrasound & Echocardiography Sir Run Run Shaw Hospital,Zhejiang University College of Medicine and 34 fetuses with VSD and PS matched to gestational age(mild TOF group)were retrospectively selected. Cardiovascular parameters were measured by 2D echocardiography,M-mode echocardiography and fetal HQ,including aortic dimension(AO)and its Z-score(AO Z-score),pulmonary artery diameter(PA)and its Z-score(PA Z-score),PA/AO ratio,main pulmonary artery diameter(MPA)and its Z-score(MPA Z-score),left pulmonary artery diameter(LPA)and its Z-score(LPA Z-score),right pulmonary artery diameter(RPA)and its Z-score(RPA Z-score),McGoon index(MGI),tricuspid annular diameter(TV)and its Z-score(TV Z-score),mitral annular diameter(MV)and its Z-score(MV Z-score),and MV/TV ratio. Measurements of global ventricular morphologic parameters included cardiac axis,left and right ventricular transverse diameters(LVW,RVW)and their ratio(LVW/RVW),left and right ventricular long diameters(LVL,RVL)and LVL/RVL ratio,left and right ventricular areas(LVA,RVA)and LVA/RVA ratio,global spherical index(GSI)and its Z-score,four chamber view transverse diameter(4CV-Width-ED),four chamber view end-diastolic longitudinal diameter(4CV-Length-ED),four chamber view end-diastolic area(4CV-Area-ED). Measurements of left and right global ventricular functional parameters included fractional left ventricular and right ventricular area changes(LVFAC,RVFAC),left ventricular ejection fraction(LVEF),left ventricular and right ventricular global longitudinal strains(LVGLS,RVGLS);end diastolic width diameter(Width-ED),SI and fractional shortening rate(FS)of 24 segments of left and right ventricles. The differences of the above parameters between the two groups were analyzed and compared,and the relationships between absolute values of GLS in left and right ventricles of TOF fetus and PA Z-score,MPA Z-score and PA/AO were analyzed. Binary Logistic regression model was used to select the best variables,and ROC curve was adopted to analyze the predictive values of ultrasonic parameter variables on TOF.Results:There were statistically significant differences in MV,TV,RVW,RVL,LVL,LVA,RVA,4CV-Length-ED,LVGLS,RVGLS,RVFAC,PA/AO,MPA,RPA,LPA,MGI,PA and PA Z-score between TOF group and mild TOF group(all P<0.05). The Width-ED values of all segments of left ventricle were statistically different between TOF group and mild TOF group(all P<0.05). There were statistical differences in SI between LV segments 4~6 and 8~24,and RV segments 1~21(all P<0.05). The FS values between the 8th and 10th to 18th segments of RV revealed statistical differences(all P<0.05). There were no statistical differences in the other parameters(all P>0.05). The absolute value of LVGLS in TOF fetuses was positively correlated with PA Z-score,MPA Z-score and PA/AO( r = 0.313,0.344,0.304,all P<0.05),and the absolute value of RVGLS was positively correlated with PA Z-score,MPA Z-score,and PA/AO( r = 0.323,0.334,0.357,all P<0.05). Binary Logistic regression model analysis confirmed that LVGLS,RVFAC and PA/AO were predictive variables. ROC curve analysis showed that the areas under the curves of LVGLS,RVFAC and PA/AO for predicting TOF were 0.746,0.693 and 0.849 respectively. The combined prediction efficiency was higher,and the area under the curve was 0.906. Conclusions:Fetal HQ combined with multiple fetal echocardiographic quantification indices can evaluate the differences in fetal heart size,shape and function between TOF and mild TOF. It is expected to provide important reference information in prenatal diagnosis and consultation for fetuses with TOF and mild TOF.
2.Research on objective evaluation of pilot ground simulation ejection training based on pressure detection
Yanpeng ZHAO ; Weiping BU ; Shu ZHANG ; Fei SHI ; Heqing LIU ; Yan JIANG ; Yining ZHANG ; Xinpo SONG ; Lei WANG
Space Medicine & Medical Engineering 2025;36(3):236-240
Objective In response to the practical issues of pilot ground simulation ejection training relying on subjective evaluation,which requires high professionalism and lacks objectivity and systematicity,an objective evaluation system and method for ejection training based on pressure detection has been designed.Methods According to the rules of ejection training about posture,maneuver and time,and utilizing technologies such as pressure detection,infrared detection,and time-triggered detection,this paper designed separate modules for ejection posture detection,ejection timing detection,and comprehensive analysis and evaluation.These modules are closely integrated with the ejection training process,achieving objective evaluation of the ejection training.Results This system and method can provide a scientific and real-time objective evaluation of the posture,movements,and time in ejection training without affecting the normal organization and process.Conclusion The objective evaluation system can provide a new approach that is highly objective and easy to operate for comprehensively evaluating and enhancing the effectiveness of ejection training,as well as for scientifically conducting ejection training and assessment.
3.Analysis of the characteristics and protection strategies of pilot parachute injury caused by land ejection
Yan JIANG ; Songyang LIU ; Heqing LIU ; Yanpeng ZHAO ; Bin ZHANG ; Yining ZHANG ; Dan LIU ; Weiping BU
Space Medicine & Medical Engineering 2025;36(3):255-258
With the rapid development of aviation technology,the ability of pilots to fly successfully and safely has attracted much attention.Improving pilots'emergency evacuation capabilities is the responsibility of every aviation worker.The injury caused by pilot parachute jumping is an important issue in flight safety.During the parachute jumping process,the pilot will be subjected to various impact forces and aerodynamic forces,which can cause damage to the pilot's spine,nervous system,circulatory system,and multiple parts of the body,and even endanger lift.This article focuses on exploring the characteristics of pilot ejection parachute injuries,categorizing and summarizing them according to the location and factors of the injuries,and analyzing their protective strategies.Targeted ground ejection simulation training is conducted for pilots in different batches to improve the combat effectiveness of the armies.
4.Study on the comfort of helmets for pilots of a new type of fighter aircraft
Yan JIANG ; Weiping BU ; Minglei WU ; Yanpeng ZHAO ; Bin ZHANG ; Yining ZHANG ; Heqing LIU
Space Medicine & Medical Engineering 2025;36(5):445-450
Objective A new type fighter pilot's helmet comfort was investigated to provide basis for generalization and popularization.Methods A quantitative questionnaire was designed to evaluate the comfort of current helmets and new helmets by pilots of series A and B fighters,and compare the new helmets with the current helmets.Thirdly,quantitative statistics of questionnaires were carried out to analyze the pilot's opinions on current helmets and new helmets.Based on the structure and quality characteristics of current helmets and new helmets,the investigation results were analyzed and discussed.Results A total of 167 pilots from series A and B fighter aircraft participated in trial wear and questionnaire investigation of new helmets.Among them,103 pilots from series A fighters and 64 pilots from series B fighters.Compared with the pilot's current helmet,the new helmet is lightweight and comfortable.Among them,92.2%of the pilots of the series A believe that the new helmet is more comfortable than the current helmet,and 90.3%of pilots think it is necessary to replace the current helmet with the new helmet.90.6%of the pilots of the Series B think the new helmet is more comfortable than the current helmet,and 92.2%of pilots think it is necessary to replace the current helmet with the new helmet.Conclusion The new fighter pilot's helmet is light and comfortable,and has been widely praised by pilots.The research results provide data support and decision-making basis for its universalization and popularization.
5.Factors influencing the occurrence of capsular contraction syndrome in cataract patients after phacoemulsification combined with intraocular lens implantation
Xi CHEN ; Haiying MA ; Xinshuai NAN ; Xin HUA ; Ming ZHAO ; Dongsheng YE ; Heqing JI
International Eye Science 2025;25(5):849-853
AIM: To analyze the influencing factors of capsular constriction syndrome(CCS)in cataract patients after phacoemulsification(Phaco)combined with intraocular lens(IOL)implantation.METHODS: Retrospective study. The data of 2 900 cataract patients(2 900 eyes)in our hospital's information system from January 2021 to January 2024 were collected. All patients were treated with Phaco combined with IOL implantation, and the incidence of CCS within 30 wk after surgery was recorded. Patients were categorized into CCS(116 cases, 116 eyes)and N-CCS group(2 784 cases, 2 784 eyes)based on the occurrence of CCS. The basic data of the two groups were compared, and the influencing factors of CCS within 30 wk after Phaco combined with IOL implantation in cataract patients were analyzed by multivariate Logistic regression.RESULTS: Among 2 900 patients(2 900 eyes)included, 116 cataract patients(116 eyes)developed CCS within 30 wk after Phaco combined with IOL implantation, with an incidence rate of 4.00%. The single factor and multi-factor Logistic regression analysis showed that the complicated diabetes, high myopia, complicated glaucoma, and axial length(AL)>30 mm were the risk factors for the occurrence of CCS after Phaco IOL implantation in cataract patients(all P<0.05).CONCLUSION: Attention should be paid to cataract patients with diabetes, high myopia, glaucoma and AL>30 mm, which will increase the risk of CCS within 30 wk after Phaco combined with IOL implantation in cataract patients.
6.Comparative study of cardiac morphology, size and function between fetuses with tetralogy of Fallot and fetuses with malalignment ventricular septal defect and pulmonary stenosis by multi-parameter quantitative echocardiography
Shuli YANG ; Bowen ZHAO ; Mei PAN ; Xiaohui PENG ; Ran CHEN ; Yuanshi TIAN ; Min DI ; Heqing GUO
Chinese Journal of Ultrasonography 2025;34(2):139-148
Objective:To analyze the differences in heart size,shape and function between fetuses with tetralogy of Fallot(TOF)and fetuses with malalignment ventricular septal defect(VSD)and pulmonary stenosis(PS)(named as,mild TOF)by fetal heart quantification(fetal HQ)and multi-parameter fetal echocardiography.Methods:From June 2021 to June 2023,50 fetuses with TOF(TOF group)diagnosed by fetal echocardiography at the Department of Diagnostic Ultrasound & Echocardiography Sir Run Run Shaw Hospital,Zhejiang University College of Medicine and 34 fetuses with VSD and PS matched to gestational age(mild TOF group)were retrospectively selected. Cardiovascular parameters were measured by 2D echocardiography,M-mode echocardiography and fetal HQ,including aortic dimension(AO)and its Z-score(AO Z-score),pulmonary artery diameter(PA)and its Z-score(PA Z-score),PA/AO ratio,main pulmonary artery diameter(MPA)and its Z-score(MPA Z-score),left pulmonary artery diameter(LPA)and its Z-score(LPA Z-score),right pulmonary artery diameter(RPA)and its Z-score(RPA Z-score),McGoon index(MGI),tricuspid annular diameter(TV)and its Z-score(TV Z-score),mitral annular diameter(MV)and its Z-score(MV Z-score),and MV/TV ratio. Measurements of global ventricular morphologic parameters included cardiac axis,left and right ventricular transverse diameters(LVW,RVW)and their ratio(LVW/RVW),left and right ventricular long diameters(LVL,RVL)and LVL/RVL ratio,left and right ventricular areas(LVA,RVA)and LVA/RVA ratio,global spherical index(GSI)and its Z-score,four chamber view transverse diameter(4CV-Width-ED),four chamber view end-diastolic longitudinal diameter(4CV-Length-ED),four chamber view end-diastolic area(4CV-Area-ED). Measurements of left and right global ventricular functional parameters included fractional left ventricular and right ventricular area changes(LVFAC,RVFAC),left ventricular ejection fraction(LVEF),left ventricular and right ventricular global longitudinal strains(LVGLS,RVGLS);end diastolic width diameter(Width-ED),SI and fractional shortening rate(FS)of 24 segments of left and right ventricles. The differences of the above parameters between the two groups were analyzed and compared,and the relationships between absolute values of GLS in left and right ventricles of TOF fetus and PA Z-score,MPA Z-score and PA/AO were analyzed. Binary Logistic regression model was used to select the best variables,and ROC curve was adopted to analyze the predictive values of ultrasonic parameter variables on TOF.Results:There were statistically significant differences in MV,TV,RVW,RVL,LVL,LVA,RVA,4CV-Length-ED,LVGLS,RVGLS,RVFAC,PA/AO,MPA,RPA,LPA,MGI,PA and PA Z-score between TOF group and mild TOF group(all P<0.05). The Width-ED values of all segments of left ventricle were statistically different between TOF group and mild TOF group(all P<0.05). There were statistical differences in SI between LV segments 4~6 and 8~24,and RV segments 1~21(all P<0.05). The FS values between the 8th and 10th to 18th segments of RV revealed statistical differences(all P<0.05). There were no statistical differences in the other parameters(all P>0.05). The absolute value of LVGLS in TOF fetuses was positively correlated with PA Z-score,MPA Z-score and PA/AO( r = 0.313,0.344,0.304,all P<0.05),and the absolute value of RVGLS was positively correlated with PA Z-score,MPA Z-score,and PA/AO( r = 0.323,0.334,0.357,all P<0.05). Binary Logistic regression model analysis confirmed that LVGLS,RVFAC and PA/AO were predictive variables. ROC curve analysis showed that the areas under the curves of LVGLS,RVFAC and PA/AO for predicting TOF were 0.746,0.693 and 0.849 respectively. The combined prediction efficiency was higher,and the area under the curve was 0.906. Conclusions:Fetal HQ combined with multiple fetal echocardiographic quantification indices can evaluate the differences in fetal heart size,shape and function between TOF and mild TOF. It is expected to provide important reference information in prenatal diagnosis and consultation for fetuses with TOF and mild TOF.
7.Ultrasound Multimodality Examination Improves the Diagnostic Efficiency of Non-Mass-Like Breast Lesions
Huiyan WANG ; Longying LU ; Heqing ZHANG ; Xue WAN ; Yushuang HE ; Honghao LUO ; Yulan PENG ; Lin MA ; Haina ZHAO
Journal of Sichuan University (Medical Sciences) 2024;55(5):1240-1246
Objective This study is focused on ultrasound multimodality examination,which refers to the combined use of three ultrasound examination modalities,ultrasound(US),acoustic radiation force impulse(ARFI)imaging,and contrast-enhanced ultrasound(CEUS).The purpose of this study is to analyze the value of applying ultrasound multimodality examination in the differential diagnosis of benign and malignant breast non-mass-like lesions(NMLs).Methods Cases of breast NMLs were analyzed retrospectively,and the nature of all the lesions was verified by pathological examination.Based on the gray-scale ultrasound image characteristics,the cases were classified into types Ⅰto Ⅴ,and type Ⅰ and type Ⅱ were further classified into 4 subtypes,Ⅰa,Ⅰ b,Ⅱ a,and Ⅱ b,according to whether there was also calcification,and the proportion of malignant cases in each subtype was statistically analyzed.Logistic regression models of US,US+ARFI,US+CEUS,and US+ARFI+CEUS for the diagnosis of malignant cases were established,ROC curves were drawn,the area under the curve(AUC)was calculated,and comparisons were made accordingly.The detection rate of malignant NMLs without calcification(atypical malignant NMLs)by the combination examination of US,ARFI,and CEUS was analyzed.Results A total of 407 cases were included in the study.All subjects were female,aged 22 to 81 years,with the average age being(47.0±1 1.0)years.There were 220 benign cases and 187 malignant cases.Ranked from the highest to the lowest,the malignancy proportion of the different types wasⅠb>Ⅱb>Ⅲ>V>Ⅰa>Ⅱa>Ⅳ.The malignant proportion of the low echo area with calcification was significantly higher than that of the lesions without calcification.The AUC(95%confidence interval[CI])for diagnosing malignant cases with the logistic regression models of US,US+ARFI,US+CEUS,and US+ARFI+CEUS were 0.895(0.862-0.927),0.908(0.878-0.937),0.921(0.893-0.948),and 0.927(0.902-0.952),respectively.Comparison of the AUC of the 4 regression models showed significant differences(P<0.001).The detection rate of US for NMLs without calcification was 80.7%.When US was used in combination with ARFI and CEUS,86.4%of the malignant NMLs lesions without calcification could be detected if the lesion CEUS score was 4 or 5 points or if shear-wave velocity(SWV)≥4.28 m/s.Conclusion Breast NMLs with calcification show high risks of malignancy,and a pathological examination is always recommended for a conclusive diagnosis.Ultrasound multimodality examination can improve the diagnostic accuracy of breast NML without calcification.
8.Performance of loop-mediated isothermal amplification (LAMP) assay for detection of Schistosoma japonicum infection in Oncomelania snails in schistosomiasis transmission-interrupted regions
Feng CHEN ; Ke-rong LI ; Wen-bao LI ; Shu-hui TIAN ; Ping LI ; Yin-jiao ZHAO ; Jing YANG ; Hua YANG ; Bing-rong LUO ; Jun-hua MA ; Ming-ming HAO ; Shao-rong CHEN ; Yu-hua LIU ; Tian-peng LUO
Chinese Journal of Schistosomiasis Control 2022;34(1):81-84
Objective To compare the effectiveness of loop-mediated isothermal amplification (LAMP) assay and microscopic examinations for detection of Schistosoma japonicum infections in Oncomelania hupensis in transmission-interrupted regions, so as to provide insights into the optimization of snail surveillance tools in these regions. Methods Four hilly schistosomiasis-endemic villages where transmission interruption was achieved were selected in Heqing County of Yunnan Province as the study villages, including Xinzhuang and Gule villages in hilly regions and Lianyi and Yitou villages in dam regions. Snail survey was performed by means of systematic sampling combined with environmental sampling in July 2018. All captured snails were identified for S. japonicum infections using microscopy. In addition, 10 to 20 snails were randomly sampled from each snail habitat following microscopy, numbered according to environments and subjected to LAMP assay. The positive rate of settings with S. japonicum-infected snails was compared among villages. Results A total of 7 949 living snails were captured from 83 snail habitats in 4 villages, and no S. japonicum infection was detected in snails. There were 226 mixed samples containing 1 786 snails subjected to LAMP assay, and positive LAMP assay was found in 3 mixed samples from 3 snail habitats in 2 dam villages. The positive rates of settings with S. japonicum-infected snails were comparable between Lianyi Village (one setting) and Yitou Village (2 set tings) (5.89% vs. 14.29%, P = 0.344). However, the overall positive rate of settings with S. japonicum-infected snails was significantly higher in dam villages (9.67%, 3/31) than in hilly villages (0) (P = 0.048). Conclusions LAMP assay is more sensitive to detect S. japonicum infections in O. hupensis than conventional microcopy method, which may serve as a supplementary method for detection of S. japonicum infections in O. hupensis in high-risk snail habitats in hilly transmission-interrupted regions.
9.Designed eye position of pilot′s helmet mounted display based on 3D scanning
Heqing LIU ; Zhuangzhi WU ; Minglei WU ; Yanpeng ZHAO ; Weiping BU ; Hongyu JIN
Chinese Journal of Aerospace Medicine 2021;32(4):198-203
Objective:To provide accurate eye position data for the system design of helmet mounted display by studying the eye position distribution and anthropometric items of pilots' head and face.Methods:The head and face data of 372 Chinese male fighter pilots were captured by a non-contact 3D scanning system to build cloud models. By noise cutting and mending processing each head and face model was built with same template mesh and unified anatomical coordinate system. The eye position design was defined according to monocular or binocular display. The positions (core of pupils) of left and right eyes and 12 anthropometric items were calculated from the 3D models.Results:The database of 372 fighter pilots′ head and face 3D models was established and it included 12 anthropometric items such as the coordinates of left and right eyes position, inter pupillary distance and vertex-pupil height.Conclusions:Based on 3D scanning technology, the distribution of eye locations (designed eye position and eye box) of pilots were built under the human head anatomical coordinate system and related anthropometric items of head and face are obtained, which could be used as the data foundation for designing pilot′s helmet mounted display system.
10.Designed eye position of pilot′s helmet mounted display based on 3D scanning
Heqing LIU ; Zhuangzhi WU ; Minglei WU ; Yanpeng ZHAO ; Weiping BU ; Hongyu JIN
Chinese Journal of Aerospace Medicine 2021;32(4):198-203
Objective:To provide accurate eye position data for the system design of helmet mounted display by studying the eye position distribution and anthropometric items of pilots' head and face.Methods:The head and face data of 372 Chinese male fighter pilots were captured by a non-contact 3D scanning system to build cloud models. By noise cutting and mending processing each head and face model was built with same template mesh and unified anatomical coordinate system. The eye position design was defined according to monocular or binocular display. The positions (core of pupils) of left and right eyes and 12 anthropometric items were calculated from the 3D models.Results:The database of 372 fighter pilots′ head and face 3D models was established and it included 12 anthropometric items such as the coordinates of left and right eyes position, inter pupillary distance and vertex-pupil height.Conclusions:Based on 3D scanning technology, the distribution of eye locations (designed eye position and eye box) of pilots were built under the human head anatomical coordinate system and related anthropometric items of head and face are obtained, which could be used as the data foundation for designing pilot′s helmet mounted display system.

Result Analysis
Print
Save
E-mail