1.Clinical Validation of a Prototype Smart Non-Invasive Pregnancy Glucose Monitor
Heqing LU ; Lirui CHENG ; Qiaoling DU ; Xiaofeng ZHANG ; Zhenzhen SUN ; Zhigang ZHU
Chinese Journal of Medical Instrumentation 2024;48(5):539-543
The aim of this study is to evaluate the effectiveness of a smart non-invasive blood glucose monitor prototype during pregnancy through clinical validation.The monitor utilizes near-infrared spectroscopy combined with AI big data analysis of photoelectric volumetric pulse wave data to achieve non-invasive monitoring of blood glucose in women during pregnancy.The research team developed a monitor that employs a sensing chip,effectively overcoming the problems of weak signals and individual differences in non-invasive blood glucose monitoring.The user experience is enhanced by visualizing the test results on the accompanying cell phone APP(application)of the smart non-invasive pregnancy blood glucose monitor.Clinical validation revealed that the non-invasive monitoring data for pregnant women aged 20~30 years significantly differed from those obtained via traditional blood glucose measurement methods,whereas no significant difference(P<0.05)was observed for pregnant women aged 31~42 years.The study concluded that further calibration of the monitor and an expansion of the sample size are necessary to enhance consistency with invasive glucose monitoring results.
2.Model construction and software design of computed tomography radiation system based on visualization.
Ying LIU ; Ting MENG ; Haowei ZHANG ; Heqing LU
Journal of Biomedical Engineering 2023;40(5):989-995
The Monte Carlo N-Particle (MCNP) is often used to calculate the radiation dose during computed tomography (CT) scans. However, the physical calculation process of the model is complicated, the input file structure of the program is complex, and the three-dimensional (3D) display of the geometric model is not supported, so that the researchers cannot establish an accurate CT radiation system model, which affects the accuracy of the dose calculation results. Aiming at these two problems, this study designed a software that visualized CT modeling and automatically generated input files. In terms of model calculation, the theoretical basis was based on the integration of CT modeling improvement schemes of major researchers. For 3D model visualization, LabVIEW was used as the new development platform, constructive solid geometry (CSG) was used as the algorithm principle, and the introduction of editing of MCNP input files was used to visualize CT geometry modeling. Compared with a CT model established by a recent study, the root mean square error between the results simulated by this visual CT modeling software and the actual measurement was smaller. In conclusion, the proposed CT visualization modeling software can not only help researchers to obtain an accurate CT radiation system model, but also provide a new research idea for the geometric modeling visualization method of MCNP.
Radiation Dosage
;
Software Design
;
Tomography, X-Ray Computed/methods*
;
Software
;
Algorithms
;
Phantoms, Imaging
;
Monte Carlo Method
3.A comprehensive review on photon-counting computed tomography: Principles, technical hurdles and analysis of clinical applications.
Haowei ZHANG ; Shuhan LI ; Ying LIU ; Heqing LU
Journal of Biomedical Engineering 2023;40(5):1012-1018
In recent years, photon-counting computed tomography (PCD-CT) based on photon-counting detectors (PCDs) has become increasingly utilized in clinical practice. Compared with conventional CT, PCD-CT has the potential to achieve micron-level spatial resolution, lower radiation dose, negligible electronic noise, multi-energy imaging, and material identification, etc. This advancement facilitates the promotion of ultra-low dose scans in clinical scenarios, potentially detecting minimal and hidden lesions, thus significantly improving image quality. However, the current state of the art is limited and issues such as charge sharing, pulse pileup, K-escape and count rate drift remain unresolved. These issues could lead to a decrease in image resolution and energy resolution, while an increasing in image noise and ring artifact and so on. This article systematically reviewed the physical principles of PCD-CT, and outlined the structural differences between PCDs and energy integration detectors (EIDs), and the current challenges in the development of PCD-CT. In addition, the advantages and disadvantages of three detector materials were analysed. Then, the clinical benefits of PCD-CT were presented through the clinical application of PCD-CT in the three diseases with the highest mortality rate in China (cardiovascular disease, tumour and respiratory disease). The overall aim of the article is to comprehensively assist medical professionals in understanding the technological innovations and current technical limitations of PCD-CT, while highlighting the urgent problems that PCD-CT needs to address in the coming years.
Tomography, X-Ray Computed/methods*
;
Photons
;
Noise
;
China
;
Phantoms, Imaging
4.Research progress of patient-specific organ doses from CT
Chuyan WANG ; Weihai ZHUO ; Xin LIN ; Heqing LU ; Tianwu XIE ; Haikuan LIU
Chinese Journal of Radiological Health 2022;31(6):756-762
The radiation risk caused by CT examination is of great concern. Organ dose is considered to be the most significant technical parameter for quantifying the patient radiation dose and assessing the corresponding risk. At present, the methods to obtain patient organ dose caused by CT examination mainly include physical phantom measurement, direct human body measurement, dose conversion coefficient, Monte Carlo simulation, and dose calculation software. Although different methods have their own characteristics and application, the individualization of organ dose is always the goal of radiation protection and dosimetry research. Patient-specific phantom developed with artificial intelligence and GPU-accelerated Monte Carlo simulation make it possible to calculate the patient-specific organ dose, and the patient-specific organ dose extrapolated by the CT detector signal provides a new solution.
5.Patients with breath test positive are necessary to be identified from irritable bowel syndrome: a clinical trial based on microbiomics and rifaximin sensitivity
Zuojing LIU ; Shiwei ZHU ; Meibo HE ; Mo LI ; Hui WEI ; Lu ZHANG ; Qinghua SUN ; Qiong JIA ; Nan HU ; Yuan FANG ; Lijin SONG ; Chen ZHOU ; Heqing TAO ; John Kao Y ; Huaiqiu ZHU ; Chung OWYANG ; Liping DUAN
Chinese Medical Journal 2022;135(14):1716-1727
Background::As a non-invasive and effective diagnostic method for small intestinal bacterial overgrowth (SIBO), wild-use of breath test (BT) has demonstrated a high comorbidity rate in patients with diarrhea-predominant irritable bowel syndrome (IBS-D) and SIBO. Patients overlapping with SIBO respond better to rifaximin therapy than those with IBS-D only. Gut microbiota plays a critical role in both of these two diseases. We aimed to determine the microbial difference between IBS-D overlapping with/without SIBO, and to study the underlying mechanism of its sensitivity to rifaximin.Methods::Patients with IBS-D were categorized as BT-negative (IBSN) and BT-positive (IBSP). Healthy volunteers (BT-negative) were enrolled as healthy control. The patients were clinically evaluated before and after rifaximin treatment (0.4 g bid, 4 weeks). Blood, intestine, and stool samples were collected for cytokine assessment and gut microbial analyses.Results::Clinical complaints and microbial abundance were significantly higher in IBSP than in IBSN. In contrast, severe systemic inflammation and more active bacterial invasion function that were associated with enrichment of opportunistic pathogens were seen in IBSN. The symptoms of IBSP patients were relieved in different degrees after therapy, but the symptoms of IBSN rarely changed. We also found that the presence of IBSN-enriched genera ( Enterobacter and Enterococcus) are unaffected by rifaximin therapy. Conclusions::IBS-D patients overlapping with SIBO showed noticeably different fecal microbial composition and function compared with IBS-D only. The better response to rifaximin in those comorbid patients might associate with their different gut microbiota, which suggests that BT is necessary before IBS-D diagnosis and use of rifaximin.Registration::Chinese Clinical Trial Registry, ChiCTR1800017911.
6.Design and Implementation of Medical Equipment Rational Deployment Information System Based on ASP.NET.
Heqing LU ; Wengang WANG ; Yang YOU ; Xiaobo ZHANG ; Wei MA ; Qilin TAO ; Shunxin QIAN ; Jin GONG ; Haowei ZHANG
Chinese Journal of Medical Instrumentation 2021;45(4):401-405
Based on ASP.NET framework, The Intelligent Estimated System for Rational Deployment of Medical Equipment (MERDIS) is designed and developed with SQL Server 2012 database and C# language. The system is used to realize the rational deployment suggestions and evaluation of medical equipment in hospitals. The system input the data of hospital medical equipment and clinical pathway into the database, and then feedback the deployment information to users which are calculated by big data information, so as to achieve the purpose of giving rational deployment of hospital medical equipment.
Databases, Factual
;
Equipment Design
;
Hospitals
7.Risk Control of UPS Power Supply for Medical Equipment.
Chinese Journal of Medical Instrumentation 2021;45(4):459-462
OBJECTIVE:
Putting forward that the risk of using UPS for medical matching is easy to be ignored by managers.
METHODS:
The method of UPS inspection was designed and used in hospital.
RESULTS:
The qualified rate of UPS for equipment matching was 66.7% and the problems were corrected. Based on the Internet of Things technology, the UPS monitoring technology was prospected.
CONCLUSIONS
It is effective to control the risk of UPS by recognizing the risk of using UPS and specifying the strategy.
Electric Power Supplies
;
Hospitals
;
Humans
;
Technology
8.Research on Quality Evaluation System of Ultrasound Diagnostic Equipment Maintenance.
Heqing LU ; Si SUN ; Xiaofeng ZHANG
Chinese Journal of Medical Instrumentation 2019;43(3):223-225
In order to improve the quality of medical equipment after-sales service quality and improve the quality of medical equipment maintenance, this paper discusses the establishment of an evaluation index system to evaluate the quality of ultrasonic diagnostic equipment. From the three aspects of maintenance results, maintenance process and maintenance coverage, the quality of the post-maintenance quality of hospital ultrasound diagnostic equipment manufacturers is objectively evaluated.
Commerce
;
Diagnostic Equipment
;
Equipment and Supplies, Hospital
;
Maintenance
;
Materials Management, Hospital
9.Application of Quality Control Circle Activity in CT Quality Control Management.
Chinese Journal of Medical Instrumentation 2018;42(3):232-234
To explore the effect and experience of quality control circle(QCC) in quality control testing for CT scanners, the quality control circle group was set up to determine the theme of quality control circle, and the causes of the failure of the quality control testing for CT scanners were analyzed, then the corresponding corrective measures were formulated and carried out. After the activity of the quality control circle, the qualified rate of CT quality control testing in the second level 2nd Class of public hospitals and private hospitals in Shanghai increased from 40.6% to 86.1%. By conducting quality control circle activities, we found the problems existed in the quality control testing of CT scanners, and put forward many corresponding corrective measures and solutions which finally improved the qualified rate of CT quality control testing.
China
;
Quality Control
;
Tomography Scanners, X-Ray Computed
;
standards
;
Tomography, X-Ray Computed
10.Design and Application of High-risk Pregnancy Monitoring & Warning Internet Platform Based on Internet of Things
Heqing LU ; Xiaofeng ZHANG ; Bin LI
Chinese Journal of Medical Instrumentation 2017;41(5):327-329,368
Through illustrating the designing of high-risk pregnancy maternal-fetal monitoring system based on the internet of things, this paper introduced the specific application of using wearable medical devices to provide maternal-fetal mobile medical services. With the help of big data and cloud obstetrics platform, the monitoring and warning network was further improved, the level-to-level administration of high-risk pregnancy was realized, the level of perinatal health care was enhanced and the risk of critical emergency of pregnancy decreased.


Result Analysis